Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.4 LAdmitted-Finance | -19.99% | ₹10.4 L | L1 | Admitted-Finance |
| 2 | L2₹10.6 LAdmitted-Finance 2RA 135 PRESS COLONY KHARVEL NAGAR UNIT III BHUBANESWAR 751001 | BHUBANESWAR | KHORDHA | ODISHA | 751001 | -18.26% | ₹10.6 L | L2 | Admitted-Finance |
| 3 | L3₹11.3 LAdmitted-Finance ODISHA OD | CUTTACK | ODISHA | 752120 | -12.53% | ₹11.3 L | L3 | Admitted-Finance |
| 4 | L4₹11.6 LAdmitted-Finance | -10.60% | ₹11.6 L | L4 | Admitted-Finance |
| 5 | L5₹11.7 LAdmitted-Finance 60 K N C ROAD NAYAN KANAN BARASAT KOL 700124 | BARASAT | NORTH 24 PARGANAS | WEST BENGAL | 700124 | -10.07% | ₹11.7 L | L5 | Admitted-Finance |
Tender Value
₹13.0 L
EMD Value
₹25,932
Closing Date
23 Mar 2026, 3:00 pmClosed
AGM (EM)
FCI RO Bhubaneswar
Modernization, Improvement of Internal and External Illumination and Upgradation of Electrification at FSD Bhubaneswar for FY 2025-26
2026_FCI_901738_1
EM/Engg./2025-26/31
Open Tender
Electrical Works
65 days
Bhubaneswar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹25,932
26 Mar 2026
10 Mar 2026
24 Mar 2026
10 Mar 2026
23 Mar 2026
10 Mar 2026
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) Single pole
(b) Triple pole and neutral
Supply of PVC insulated PVC sheathed/XLPE power cable of 1.1KV grade of AL. conductor cable as reqd. confirming to ISI-7098 (part -1) 1988 with upto date amendment of the following sizes.
(a) 4x35 sq. mm armoured
(b) 4x25 sq. mm armoured
(c) 4x 16 sq mm armoured
(d) 2 x 10 sq mm armoured
(e) 4 x 6 sq mm armoured
(f) 2 x 6 sq mm armoured
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (a) Upto 35 sq. mm
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required (a) 100 mm dia
Supplying and fixing Weatherproof Junction Box,(Size : 28cmX 21cm X 11cm) White Colour Fiber Reinforced Plastic junction box with hinged door along with supply and fixing connector terminals and 6 Amp c-curve SP MCB.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 45 watt
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supplying, installation testing and commissioning of 45 Watt LED post top luminaires in pressure die-cast aluminium housing with IP65, LEDs with lumen m efficacy noit less than 110 lm/W,colour temp 5700 K, THD (%) < 10, Polycarbonate diffuser in opal finish and fixing existing gate piler & dismantling the existing fitting etc at the site of work as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
(a)4 X 35 sq. mm (32mm)
(b) 4 X 25 sq. mm (28mm)
(c) 4 X 16 sq. mm (28mm)
(d) 2 X 10 sq. mm (19mm)
(e) 4 x 6 sq mm (22 mm)
(f) 2 X 6 sq. mm (19mm)
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
(a) 200 Watt
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40 A
Supplying and fixing FP sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.
Supplying / Installation / Testing / Commissioning of wall / floor mounted cubicle type control panel board of dust proof, weather proof of size 1150 X 1000 X 450 mm of 14 SWG Sheet with seprate compartment, factory finished painting with 9 tank process, locking arrangement complete with internal wiring with Aluminium bus bar strip of size 25 mm X 5 mm thick from bus bar to out going MCCB and copper wire of size 6 Sq mm from bus bar to MCB SPN with copper lugs / ferrous earth bolts, rubber gasket alongwith operating handle. The following mountings are to be fixed in the panel board. a) 100 Amp, 36 kA MCCB 4 pole b) 32 Amp , 10 kA C Curve MCB 4 pole 3 No. c) 250 A Aluminium bus bar of size 25 X 5 mm mounted on epoxy insulator with brass and nuts & bolts for 3 Phase 4 Wire with heat shrinking sleeve RYB & N (500 X 4 Nos.) - 1 Set
Deduct Scrap value including old panels, conduits, wiring, fittings, overhead line & other old unservicable electrical assesories
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
MTF.pdf
Tender Documents • 1.85 MB
BOQ_947820.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid