Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | ₹14.0 L Quoted ₹14.4 L | L1 | Accepted-AOC Accepted due to lowest |
| 2 | L2₹15.6 L+₹1.1 L (7.88%)Rejected-Finance | ₹15.6 L+₹1.1 L (7.88%) | L2 | Rejected-Finance Rejected due to not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Feb 2020, 6:00 pmClosed
COL NK SAH
CWE AF pune lohegaon 411032
REPAIR/REPALCEMENT OF DEFECTIVE LT UG CABLES OTHER MISC AND CONNECTED WORKS REPAIR/ MAINTENANCE OF HEATING AND COOLING APPLIANCES AND REFRIGERATION PIPING AND REPAIR MAINTENANCE OF TRANSFORMER VCB AND RMU HT PANEL AND HT UG CABLE AND OTHER CONNECTED
2019_MES_309443_1
82565/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF Thane
As per Nit and Tender document
5 documents required · 5 mandatory
₹500
GE AF Thane
₹40,000
Yes
17 Aug 2020
26 Dec 2019
11 Feb 2020
27 Dec 2019
10 Feb 2020
10 Jan 2020
Amount
Material and labour for servicing of Split type AC / Window Type ACs of any size/capacity by disconnecting the electrical/water connections,taking out from its position,cleaning the external dirt & dust ,cleaning air filter,condenser,washing by water jet,drying by air blower,checking all electrical connections and refixing in existing position and testing complete all as specified and directed by Engr-in-charge. Note:- - (i) Servicing shall be carried out once in six month of each equipment . (ii) Servicing Card shall be provided by contractor for each machine and shall be signed by the Engr-in- Charge and users representative
Material and labour for servicing of Water cooler/deep freezer/refrigerator of any size/capacity by disconnecting the electrical/water connections,taking out from its position,cleaning the external dirt & dust ,cleaning air filter,condenser,washing by water jet,drying by air blower,checking all electrical connections and refixing in existing position and testing complete all as specified and directed by Engr-in-charge. Note:- - (i) Servicing shall be carried out once in six month of each equipment . (ii) Servicing Card shall be provided by contractor for each machine and shall be signed by the Engr-in- Charge and users representative.
Supply and fixing in repairs and replacement of compressor sealed unit including necessary refrigerent charging to the system of capacity/size and suitable of the undermentioned cooling appliance equipments including testing complete all as specified and directed by Engr-in-charge. (a) Split type AC 1 Ton Capacity
(b) Split/Window type AC 1.5 Ton Capacity
(c) Split Type AC 2 Ton Capacity
(d) Water cooler of capacity 80/40 ltrs
(e) Water cooler of capacity 120/60 ltrs
(f) Deep freezer of capacity 300 ltrs
(g) Refrigerator 110/220/300/310 ltrs capacity
Supply and fixing in repairs door magnetic gasket for refrigerator of any make and capacity complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs of Condenser Coil made of copper suitable of the undermentioned cooling appliance equipments including testing complete all as specified and directed by Engr-in-charge. (a) Window/ Split type AC 1.5 Ton.
(b) Split Type AC 2 ton Capacity.
(c) Condenser coil of Refrigerator 110/220/300/310 Ltrs Capacity.
(d) Condenser coil for Water Cooler Capacity of 120/60 ltrs.
(e) Condenser coil for water cooler apacity of 80/40 Ltrs.
Supply and fixing in repairs of Capillary tube suitable of the undermentioned cooling appliance equipments including testing complete all as specified and directed by Engr-in-charge. (a) Split type air conditioner of capacity 1 ton
(b) Split / Window type air conditioner of capacity 1.5 ton
(c) Split type air conditioner of capacity 2 ton
(d) Refrigerator of capacity of 110/220/300/310 Ltrs
(e) Water cooler of capacity 80/40 Ltr.
Supply and fixing in repairs of housing (outdoor Unit) suitable of the undermentioned cooling appliance equipments including testing complete all as specified and directed by Engr-in-charge. (a) Split type AC of capacity 1.5 Ton as per sample
(b) Split type AC of capacity 2 Ton as per sample
Supply and fixing in repairs of Indoor Unit suitable of the undermentioned cooling appliance equipments including testing complete all as specified and directed by Engr-in-charge. (a) Split type AC of capacity 1.5 Ton as per sample
(b) Split type AC of capacity 2 Ton as per sample
Supply and fixing in repairs of Drain Tray including PVC Pipe, Clamps etc suitable of the undermentioned cooling appliance equipments including testing complete all as specified and directed by Engr-in-charge. (a) Water cooler of capacity 120/60 Ltrs.
(b) Water cooler of capacity 80/40 Ltrs.
Material and labour in repairs for flushing out the refrigerant system and checking for leakage test of refrigerant and arresting of leakage if any including re-charging of refrigerant gas after repairs and testing of the undermentioned cooling appliances equipments complete all as specified and directed by Engr-in-charge. (a) Split typ AC of capacity 1 Ton
(b) Split type AC of capacity 1.5 Ton
(c) Split type AC of capacity 2 Ton
(d) Water cooler of capacity 120/60 ltrs
(e) Water cooler of capacity 80/40 ltrs
(f) Refrigerator of 110/220/300/310 Ltrs capacity
(g) Deep freezer of 300/310 Ltrs capacity
Supply and Fixing in replacement of Air filter suitable of the undermentioned cooling appliances equipments complete all as specified and directed by Engr-in-charge. (a) Windo type AC of capacity 1 Ton.
(b) Split type AC capacity of 1.5 Ton.
(c) Split type AC of capacity 2 Ton.
Supply and Fixing in replacement of box type start Relay suitable of the undermentioned cooling appliances equipments complete all as specified and directed by Engr-in-charge. (a) Window type AC of capacity 1 Ton.
(b) Water cooler Capacity 80/40 Ltrs
(c) Water cooler Capacity 120/60 Ltrs
Supply and fixing in replacement of starting capacitor of 80/120 mfd capacity suitable of AC 1 Ton/1.5 Ton/2 Ton/3 Ton ccomplete all as specified and directed by Engr-in-charge.
Supply and Fixing in replacement of Running capacitor of 36/50 mfd capacity suitable of 1 Ton/1.5 Ton/2 Ton/3 Ton Split type AC and Water Cooler Capacity of 120/60,80/40 Ltrs complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of M.S bracket heavy duty including fasterners for Mounting of AC 1.5 /2 Ton capacity split out door unit complete all as specified and directed by Engr-in-charge.
Supply and Fixing in replacement Starting capacitor 36 mfd for water cooler complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement Running capacitor 10 mfd for water cooler complete all as specified and directed by Engr-in-charge.
Material and Labour for disconnecting and taking down burnt out blower/Fan motor of Split type AC of any capacity,opening the motor and removing burnt out winding,rewinding the same with supper enameled copper wire of existing gauge, varnishing ,heating including re-fixing in the existing position with and testing complete all as specified and directed by Engr-in-charge..
Ditto-all as per item No 45 here-in-before but Blower/Fan motor of water cooler of 80/40 Ltr /120/60 Ltr capacity complete all as specified and directed by Engr-in-charge.
Supply and Fixing in replacement of Fan Motor suitable of the undermentioned cooling appliance eqiupments complete all as specified and directed by Engr-in-charge. (a) Split Type Ac of Capacity 2 Ton
(b) Split /Window type Ac of Capacity 1.5 Ton
(c) Split Type Ac of Capacity1 Ton
(d) Water cooler of capacity 80/40 ltr
(e) Water cooler of capacity 120/60 ltr
Supply and Fixing in replacement of Fan blade suitable of the undermentioned cooling appliance eqiupments complete all as specified and directed by Engr-in-charge. (a) Split Type AC 1 Ton/1.5 ton
(b) Split Type AC 2 Ton
(c) Split Type AC 3 Ton
Supply and Fixing in replacement of thermostat switch suitable of the undermentioned cooling appliance eqiupments complete all as specified and directed by Engr-in-charge. (a) Water cooler of any capacity up to 120 Ltrs.
(b) Refrigerator of any make up to 310 Ltrs capacity
(c) Deep Freezer of 300 Ltrs capacity
(d) Storage type water heater 25/50 Ltrs capacity
Supply and Fixing in repairs of Printed Circuit Board including replacement of rewireable spares like transformer, capacitor, sensor, display, fuse,IC and etc of the undermentioned cooling appliance eqiupments complete all as specified and directed by Engr-in-charge. (a) Split type AC 1 Ton and 1.5 Ton
(b) Split type AC 2 Ton
Supply and Fixing in replacement of swing motor suitable of the undermentioned cooling appliance eqiupments ccomplete all as specified and directed by Engr-in-charge.. (a) split Type AC of capacity 1.5 Ton
(b) split Type AC of capacity 2 Ton
(c) Window Type AC of capacity of 1.5 Ton
Supply and fixing in replacement of heating element suitable of the undermentioned water heating eqiupments complete all as specified and directed by Engr-in-charge. (a) 1500 Watts to 2000 watts cap single phase 230 V AC 50 Hz of existing make for 25 ltr capacity
(b) 2000 Watts to 3000 watts cap single phase 230 V AC 50 Hz of existing make for 50 ltrs capacity
Supply and fixing in replacement of non return valve 15 mm bore of Gun metal or brass for storage type water heater complete all as specified and directed by Engr-in-charge.
Material and Labour for preparing of old painted surfaces of following cooling appliance equipments except cooling coil cleaning and applying two coats of synthetic enamelled paint of approved colour by spray gun machine complete all as specified and directed by Engr-in-charge. (a) Out door unit of Split type AC 1.0 /1.5 Ton
(b) Out door unit of Split type AC 2/3.0 Ton
(c) Water cooler of any Capacity and size
(d) Refrigerator of capacity 310 Ltrs
(e) Deep Freezer of 300 ltr capacity
Supply and replacement of AC Remote Control with batteries suitable including testing at site make and capacity of the undermentioned cooling appliance equipments complete all as specified and directed by Engr-in-charge. (a) Split type AC 1.5 Ton
(b) Split type AC 2 Ton
Material and Labour for disconnecting Split type AC/Window type AC of any capacity in all respect,transporting to workshop for repairs, refixing the same after repairs, including suitable refrigent charging and testing ccomplete all as specified and directed by Engr-in-charge.
Material and Labour for disconnecting the Water cooler of any capacity in all respect,transporting to workshop for repairs of Galvanised Iron Sheet metal work ,patch work with replacement of Galvanised Iron sheet of existing gauge including welding, tinkering, repairs base frame and refixing the existing compounentswith suitable refrigent chaging and testing complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement PVC drain pipe of size 25 mm dia complete all as specified and directed by Engr-in-charge..
Supply and fixing in replacement of sensor suitable to existing split / window AC complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of blower fan unit for spilt AC (outdoor unit) of suitable to existing size and make complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of blower fan unit for spilt AC (indoor unit) of existing size and make complete all as specified and directed by Engr-in-charge.
Supply and filling Gas suction/discharge two way locking valve for spilt AC of existing size and existing make complete all as specified and directed by Engr-in-charge.
Material and Labour of FR insulated stranded copper conductor 3 core 2.5 sqmm round cable for split/window typr AC and water cooler complete all as specified and directed by Engr-in-charge.
Material and Labour in replacement of gas suction/discharge brass valve locking cap split AC of existing size complete all as specified and directed by Engr-in-charge.
M & L for copper pipe of size 5/8'' for split AC of any capacity including rubber sleeve complete all as specified and directed by Engr-in-charge..
M & L for copper pipe of size 3/8'' for split AC of any capacity including rubber sleeve complete all as specified and directed by Engr-in-charge..
Taking down water heater of 25 Ltrs capacity by disconnecting water and electrical connection ,transporting to workshop for repairs of water storage tank by welding /brazing to arrest water leakage.and refixing back at same location after testing including water/electrical connection complete all as specified and directed by Engr-in-charge.
Taking down water heater of 50 Ltrs capacity by disconnecting water and electrical connection ,transporting to workshop for repairs of water storage tank by welding /brazing to arrest water leakage.and refixing back at same location after testing including water/electrical connection complete all as specified and directed by Engr-in-charge.
M & L for servicing of water heater storage type of any capacity, including checking of thermostate, heating element indicator lamp etc; complete all as specified and directed by Engr-in-charge..
S & F in replacement PVC pipe heavy duty with wiremess for hot water of water heater of 60 cm in length including brass coupling complete all as specified and directed by Engr-in-charge..
Supply and fix PVC connection High Density Pipe 15mm sizes with PTMT nuts of lengths 600mm suitable for Cold and Hot water complete all as specified and directed by Engr-in-charge..
Material and Labour for preparing of old painted surfaces of following appliances applying two coats of synthetic enamelled paint of approved colour by spray gun machine complete all as specified and directed by Engr-in-charge. (a) Water heater of 50 ltr capacity.
(b) Water heater of 25 ltr capacity.
Supply and fixing in replacement of brass water supply inlet and outlet Flow unit assembly suitable for 50 ltr capacity for storage water heater as per sample with gasket nut bolts and washer etc complete all as specified and directed by Engr-in-charge.
-Ditto- all as per item No 92 above but for 25 ltr capacity complete all as specified and directed by Engr-in-charge..
Excavation in trenches n. exc. 1.5 M in width and 1.5 m in deep for laying of pipes and getting out in Soft / loose soil complete all as specified and directed and by Engr-in - Chrage
Excavation in trenches n. exc. 1.5 M in width and 1.5 m in deep for laying of pipes and getting out in hard / dense soil complete all as specified and directed and by Engr-in - Chrage
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm complete all as specified and directed and by Engr-in - Chrage
Removing excavated material n. exc. 50 M away and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and directed and by Engr-in - Chrage .
M&L for providing crushed stone sand cushioning to UG cable including punning down of sand in layers complete all as specified and directed and by Engr-in - Chrage Note :- Quantity of Sand will be measured after punning down.
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” LV type1 flat size 250 x 150 x 40 mm laid in trenches complete all as specified and directed and by Engr-in - Chrage
Supply and lay in trenches / alongwith wall / floor / ceiling pipes GI light grade of the following sizes with all fittings and accessories for cable protection including taking out unservicable pipes complete all as specified and directed. (a) 80mm dia bore
(b) 50mm dia bore
(c) 40 mm dia bore
Supply and lay cable XLPE insulated armoured, heavy duty electric power cable (heavy duty) 1100 Volts grade cross sectional area with standard aluminium conductor of the following sizes with cable connections, suitable size of lugs, nuts, bolts and washers including taking out unservicable cable from trenches complete complete all as specified and directed and by Engr-in - Chrage (a) 4 core 10 sqmm
(b) 4 core 16 sqmm
(c) 3.5 core 25 sqmm
(d) 3.5 core 35 sqmm
(e) 3.5 core 50 sqmm
(f) 3.5 core 70 sqmm
Supply and fixing LT Cable jointing kit for 1100V (Earthed) grade cable for straight through joint with jointing materials heat shrinkable and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete complete all as specified and directed and by Engr-in - Chrage
Material and Labour for cutting existing road/hard standing not exc 50*60 cm in wide & depth getting out excavated material for laying GI tube for passing through LT cable, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:1.5:3; Including removal of surplus complete all as specified and directed and by Engr-in - Chrage
M & L for maintenance free chemical Gel based earthing having 80mm dia 3 Mtr long GI pipe(wall thickness of 3.2 mm) 50 Kg Back Fill Compund including including testing on completion and taking down of old earthing complete all as specified and directed and by Engr-in - Chrage
Material and labour for copper strip of size 20*3 mm complete all as specified and directed by Engineer-in -charge.
Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness(below or above) ground level including removal all as specified complete all as specified and directed and by Engr-in - Chrage
M&L for PCC(1:1.5:3) type B1 (using 20 mm graded stone aggregate as in sub base to floor 100 mm thick finished aven and smooth without using extra cost) complete all as specified and directed and by Engr-in - Chrage
Supply and fixing in repairs for MCCB 4 pole, 415 Volts with adjustable type short circuit and over load with connections, suitable lugs, nuts, bolts, washers of following capacities including taking out unsercable MCCB from existing places and removing all connections complete all as specified and directed and by Engr-in - Chrage :-L&T/Havells/Legrand (a) 100 amps, 16KA
(b) 125 amps, 16KA
(c) 160 amps, 35/36KA
(d) 200 amps, 36KA
(e) 250 amps, 36KA
M&L for MS chequered plates of not less than 6 mm thick of sizes as per site requirement incl cutting welding of strip on the edges for proper fixing and provn of handles for lifting & fixing arrangement as shown & directed incl taking out the old & unservicable chequered plates including two coats of synthetic enamelled paint of approved colour and over a coat of red oxide or primer complete all as specified and directed and by Engr-in - Chrage
Supply and fix cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,earthed electric power underground cable (Heavy duty) 11000 Volts grade earthed system with stranded aluminum conductor of size 95 Sqmm 3 Core and including taking out unserviceable cable from existing places complete all as specified and directed by Engr-in-Charge.
Taking out damaged LT bushing with rubber gasket and and supply & fixing new LT bushing of existing same size and same make with rubber gasket with and necessary T&P arrangement for transformer 11/0.433 KV of capacity 50 KVA to 300 KVA, after replace the LT bushing connection with fully opernational condition of out put voltage parameters complete all as directed by Engineer in Charge.
Taking out damaged HT bushing with rubber gasket and and supply & fixing new HT bushing of existing same size and same make with rubber gasket with and necessary T&P arrangement for transformer 11/0.433 KV of capacity 50 KVA to 300 KVA, after replace the HT bushing connection with fully opernational condition of out put voltage parameters complete all as directed by Engineer in Charge.
Material and Lbour for disconnecting and opening of all electrical connections for HT/LT sides, opening of top cover of transformer, carefully removing worn out gaskets with help of scrappers of LT/HT sides and neutral of all bushings, air vent pipe gasket and replace with new all gaskets cock sheet refixing its original position of all bushings, airvent pipe and positioned top cover including wornout nuts and bolts alongwith washers, checking to all parameters, lekage of oil and re connected all HT/LT connections topping up of oil upto mark level for 11 KV/0.433 KV if capacity 50 to 300 KVA transformer including required T&P items completed all as directed by Engr-in-Charge. Note:- Topping up of new transformer oil shall be measured and paid separately to relevant items.
Supply and fixing in replacement of Breathers assembly with Silica jel with fixing suitable GI Nipple, sockets to matched with existing transformer 50 to 300 KVA inculding unserviceable breather units from existing transformer completed all as directed by Engr-in-Charge.
Supply and Filling of Silica Gel Breathers suitable for transformer installed at various places/Locations complete all as directed by Engr-in-Charge.
Supply and fix Cork sheet gasket for top cover of transformers including dismantling /disconnecting LT/HT side connections from bushings, opening of the top cover of and removing unservicable cock sheet with proper scrappers of existing transformer with required T&P and refixing the same and reconnected all HT/LT connections shall be made, topping up of transformer oil upto mark level as directed and directed by Engr-in-Charge. Note :- Topping up of nes transformer oil shall be measured and paid to relevant items.
Supply and fix in replacement of Brass gate valve size 40mm including switch off electric supply of incoming and out going of the transformer drain out all oil complete oil from main tank stored to suitable container taking out non-functioal gate valve from eixting drain out system with suitable size end cap including refilling of transformer oil up to mark level of transformer capacity 50 to 300 KVA complete all sepecified and dircted by Engr-in-Charge.
Supply and fix in replacement of LT insulator 1100 Volts grade suitable for transformer 50 to 300 KVA 11/0.433 KV complete all as directed by Engr-in-Charge
Supply and fix in replacement of HT insulator 12000 Volts grade suitable for transformer 50 to 300 KVA 11/0.433 KV complete all as directed by Engr-in-Charge
Filteration of transformer oil of different capacities installed at various locations/places of transformers removing of carbon particles from transformer oil and achieve dielectric strrength of oil up to 50 KV of transformer capacity 50 to 300 KVA and disconnect and connect of existing connections including the testing of oil with help of filteration machine along with testing equipment complete all directed by Engineer-in-Charge.
Supply and fix in replacement of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor size 3 core 95 sqmm including disconnecting, cutting and removeing unserviceable joints from existing cable complete all as specified and directed
Supply and fix in replacement of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor size 3 core 95 sqmm including disconnecting, cutting and removeing unserviceable joints from existing cable complete all as specified and directed and by Engr-in - Chrage
Supply and topping up of transformer oil with dielectric strength value 50 KV to up to mark level of eixisting transformers of capacity 50 KVA to 300 KVA installed at various locations/places complete all directed by Engineer-in-Charge. Make :- Savita ChemicalApar Electricals or as aproved.
M&L for spray painting of transformers body, raditor fins after scrapping down old fallen paint, rust etc., by using emery paper, brush or scrapers etc., for preparation of surfaces including putty etc., and painting synthetic enamel paint primer all as per the colour code of each compunent all as speicfied for transformer of capacity 200 KVA to 300 KVA complete all as directed by Engr-in-Charge.
Ditto- all per Sl No 135 herein before but for transformer of capacity 100 KVA complete all as directed by Engr-in-Charge.
Ditto- all per Sl No 135 herein before but for transformer of capacity 50 KVA complete all as directed by Engr-in-Charge.
Servicing and maintenance of HT 11 KV switch gear/VCB panels decarbonsing of all contact points including greasing of the moving parts, cleaning of the moving/stationary contact with CTs, reomoving moisture by means of hot air blower genral servicing of the switch gear, renewal of gaskets nuts bolts, etc., complete including testing of the switch gear after repairs and including relays cabliration and testing of all relays with setting with connected load as complete all as specified and directed by Engr-in-Charge. Note :- 1 Each switch gear/load break switch /breaker shall be counted as separate unit for the purpose of measurement. 2. Servicing shall be carried out after six months period all as directed by Engr-in-Charge. 3. Porper take care shall be taken to isolate the supply and it shall as directed by Engr-in- Charge. 4. During the period any fault megger values with test certificate should submmitted. 5. Checking of all electrical connection for its proper tightness. 6. If in case any breakdown the service Engineer attend the brake down immidiately and make the HT switch gear serviceable with in 8 working hours.
Supply and fix in repairs HT Barrel Fuses 11 KV grade of following ratings current carrying capacity complete all as directed by Engr-in-Charge. (a) 6 Amps
(b) 10 Amps
(c) 16 Amps
M & L for charging of split /widow AC, Water cooler , deep freezer etc with refrigent gas R-22 complete all as specified and directed by Engr-in-charge..
M & L for charging of refrigerator , deep freezer etc with eco friendly refrigant gas R-134a etc complete all as specified and directed by Engr-in-charge..
S & F in replacement of thermoostate of geyser as per existing model and make complete all as specified and directed by Engr-in-charge..
NANGIA AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .