| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC Accepted due to quoted lowest rates | |
| 2 | L2₹38.8 L+₹1.0 L (2.74%)Rejected-Finance | L2 | Rejected-Finance Rejected due to quoted high rates | |
| 3 | L3₹40.4 L+₹2.6 L (6.80%)Rejected-Finance | L3 | Rejected-Finance Rejected due to quoted high rates | |
| 4 | L4₹40.7 L+₹2.9 L (7.77%)Rejected-Finance | L4 | Rejected-Finance Rejected due to quoted high rates | |
| 5 | L5₹41.3 L+₹3.6 L (9.42%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | L5 | Rejected-Finance Rejected due to quoted high rates |
Tender Value
₹40.3 L
EMD Value
₹80,600
Closing Date
10 Jan 2020, 6:00 pmClosed
CWE FEROZEPUR CANTT
HQ CWE FEROZEPUR CANTT
CA No CWE/FZR-47/2019-20 Special Repair to Bldg No P-90 (Wksp Repair Shed) at Fd Wksp Coy of EME Bn under GE (West) Ferozepur Cantt
2019_MES_308321_1
CWE/FZR-47/2019-20
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹80,600
Yes
1 Feb 2020
21 Dec 2019
14 Jan 2020
21 Dec 2019
10 Jan 2020
4 Jan 2020
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified.
M&L for Non skid Ceramic coloured ( colour and shade as approved) tiles,any shape, 7mm to 8 mm thick area of each tile exc. 0.11 sqm and not exc 0.18 sqm as in flooring set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles laid over & including 15 mm thick screed in cement mortar (1:6), complete all as specified.
All as per Item No-2, herein before but as on vertical surfaces such as skirting/dado over and including 10 mm thick rendering in cement mortar (1:4), complete all as specified.
M&L for Non skid Ceramic coloured (colour and shade as approved) tiles, any shape, 7mm to 8 mm thick area of each tile exc 0.06 sqm and not exc 0.11 sqm as in flooring, set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles laid over & including 15 mm thick screed in cement mortar (1:6), complete all as specified.
M&L for Glazed ceramic tiles, coloured (colour & shade as approved), of size 450x300x7 mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry and pointed in white cement with pigment to match the colour of tiles, laid over & including 10 mm thick backing coat in cement mortar (1:4), complete all as specified.
Demolition of un-reinforced cement concrete of any description and in any position, complete all as specified.
M&L Cement concrete (1:2:4) type B-0 (12.5 mm graded stone aggregate) as in kerbs, mud stops, round or chamfered on edges etc including form work, weathering, slightly rounded or chamfered complete all as specified.
M&L for 50mm thick Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in floor topping, finished even and fair without using extra cement, complete all as specified.
M&L for 25mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as levelling course under tiling ect, complete all as specified.
M&L for 20mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner), complete all as specified.
M&L for chequered cement concrete tiles of size 20cmx20cmx25 mm thick set and jointed in neat cement slurry and pointed in grey cement and no pigment laid over 15 mm thick screed in cement mortar (1:6), complete all as specified.
Taking down cement plaster from brick walls of any description, racking out joints, hacking for key, scrubbing down with water etc, complete all as specified.
M&L for Rendering 10 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
M&L for Rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
M&L Rendering 5 mm thick in cement mortar (1:3) on ceiling concrete surfaces finished even and smooth without using extra cement, complete all as specified.
Supply only integral water proofing compound ISI marked, complete all as specified.
M&L for 15 mm thick cement mortar (1:4) brick/concrete surfaces for Sunken floors, mixed with using WPC @ 100gms per 50 kg bag, added with 23 ltr of water and all as specified and directed by Engr-in-Charge, using WPC, complete all as specified. (WPC shall be measured and paid seaparately)
M&L for 30mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate for floor finish for sub base in sunken portion mixed with using WPC (WPC shall be measured and paid seaparately), without using extra cement, complete all as specified.
M&L PCC (1:5:10) type E-2 (40 mm graded stone aggregate) as in filling under sunken floors, complete all as specified.
M&L for Taking down wooden/steel chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts,making good jambs with plaster in CM(1:4) to match with existing finish, complete all as specified.
All as per item No 20 herein before but size exceeding 1.5 Square metre and not exceeding 4 Square metre each.
S&F Factory made pressed steel frames made of 1.25 mm thick MS sheet of profile 105 mm X 60 mm for door and window frames with one or more rebates including lock strike plate, shock absorber, 20 mm dia 60 mm long MS conduit for housing of a drop bolt,hinges, hold fasts/lugs etc, treating of internal surfaces of chowkhats with coal tar or black paint including hold fasts/lugs etc complete all as specified.
S&F Factory made pressed steel frames made of 1.25 mm thick MS sheet of profile 125 mm X 60 mm for door and window frames with one or more rebates including lock strike plate, shock absorber, 20 mm dia 60 mm long MS conduit for housing of a drop bolt,hinges, hold fasts/lugs etc, treating of internal surfaces of chowkhats with coal tar or black paint including hold fasts/lugs etc complete all as specified.
M&L Cement concrete (1:3:6) type C-1 (20 mm graded stone aggregate) as in filling of steel chowkhats and bed blocks of hold fast including necessary formwork, complete all as specified.
S&F Factory made, 35mm thick, 2nd class hard wood (Hollock), plain framed, panelled shutters, any number of panels, panels shall be of 9 mm thick B.W.P. commercial ply or 12mm thick BWR grade veneered particle board medium density, wood particle board with commercial face veneers, size of members as specified in clause 8.24(a) of MES Schedule Part-I section-8 complete all as specified.
S&F Factory made 35 mm thick,2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass/gauge etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified.
M&L Factory made box type side hung steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle and with/wihout glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07.
S&F in repairs anodised aluminium door, window, ventilator frame with side hung/including sliding aluminium sections sliding window where required or pull and push type in frames and shutters with two track sliding aluminium frame and in partitions, make: Jindal (or) Equivalent make of approved size including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws, including necessary anodised aluminium fittings like handles etc complete all as specified as per manufacturers instructions. Note : GlassPane and EPDM Rubber beading/gasketwill be measured and paid seperately.
S&F EPDM Rubber beading of suitable size around glass in aluminium windows /ventilator shutters, complete all as specified.
S&F 150 mm Floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring complete all as specified and as directed.
S&F 4 lever aluminium mortice lock,vertical type size 100 mm complete all as specified.
S&F hydraulically extruded aluminium body door closer regulated designation No 3 universal type suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 Kg etc complete all as speciified.
S&F 4.8 mm thick sheet glass ordinary quality along with EPDM rubber all around the glass edges exc 0.5 sqm in each pane and fixed into aluminum frame work complete all as specified.
S&F Aluminium anodised tower bolt of extruded section, 150mm length of bolt and fixed with screws, complete all as specified and directed.
S&F Aluminium (cast type) anodized, bow handle 150mm size fixed with screws complete all as specified and directed.
All as per srl item N0 35 above, here in before but 100 mm size, complete all as specified. .
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified.
S&F 12 mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination white lamination, fixed with screws to alluminum frame work complete all as specified and directed by Engineer in Charge
S & F 24 mm Solid PVC board plain colour, fixed with screws or adhesive with complete as in shutters, complete all as specified and directed by Engineer in charge
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps as in rain water pipes, complete all as specified.
S&F 160 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps as in rain water pipes, complete all as specified.
S&F in repairs 110 mm bore PVC (SWR) bends/shoe and provided with access door any radius fixed to walls including distance pieces and stack clamps, including making good around complete all as specified.
S&F 110 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified.
S&F 110 mm bore PVC (SWR) junction double, (double T), equal or unequal complete all as specified.
S&F in repair 15 mm bore bib tap of, fancy type chromium plated, screwed down, high pressure with crutch or butter fly handle, complete all as specified.
S&F in repair 15mm stop cock cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule fancy type chromium plated with fancy type shank and cup, complete all as specified.
S&F in repair, tublar Towel Rail 60cm long 'D' type between flanges of chromium plated 20mm dia fixed to walls, complete all as specified.
Taking up or down existing steel water tubing, 15 mm bore alongwith connections fixed/laid in any situation, complete all as specified
Taking up or down existing steel water tubing, 20 mm bore alongwith connections fixed/laid in any situation, complete all as specified.
S&F Galvanised iron steel water tubing, 15mm bore, medium grade with all fittings and fixed to walls and ceiling, complete all as specified.
S&F Galvanised iron steel water tubing, 20mm bore, medium grade with all fittings and fixed to walls and ceilings,complete all as specified.
Re-Fixing only, after cleaning old steel water tubing, 15mm bore and connections in new or old position using new fittings fixing to wall/ceiling or laid in floors complete all as specified.
Re-Fixing only, after cleaning old steel water tubing, 20mm bore and connections in new or old position using new fittings complete all as specified.
S&F 15 mm bore Brass CP mixer for mixing hot & cold screwed down for iron pipe and fixed in repairs, complete all as specified.
S&F in repairs PVC syphonic action type low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, 32 mm PVC flush pipe and necessary fixing arrangements and connecting to water pipe, complete all as specified .
S&F in repair Vitreous china white squatting pan orrissa pattern of size 580mm x 440mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, complete all as specified.
S&F in repairs wash hand basin, flat back 550mm x 400mm vitreous china (white) including PTMT waste coupling/fittings, 32 mm bore size, waste pipe, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing, complete all as specified.
S&F in repair 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including fittings, complete all as specified.
S&F in repair 20mm bore PTMT ball valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule, complete all as specified.
M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified.
M&L Preparation of old treated steel surfaces of any description, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
M&L Preparation of new wooden or wood based surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified.
M&L Preparation of old treated wooden surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified.
M&L Preparation of newly plastered surfaces and applying two coats of oil bound distemper, over a coat of chalk whitening, complete all as specified and as directed.
M&L Preparation of old plastered surfaces of ceiling & applying two coats of white wash, complete all as specified.
M&L Preparation of newly plastered surfaces of ceiling & applying three coats of white wash, complete all as specified.
M&L Complete removal of existing treatment and preparation of old plastered surfaces of walls and applying one coat of cement base paint, complete all as specified.
M&L Preparation of new plastered surfaces walls etc and applying two coats of cement base paint over a coat of primer, complete all as specified.
M&L Complete removal of existing treatment and preparation of old plastered surfaces of walls and applying two coats of oil bound distemper, over a coat of chalk whitening, complete all as specified and as directed.
M&L Preparation of old decorated plastered or unplastered surfaces by brooming down with steel wire brush, scarping down smoke soot, mould,moss and efflorescent salts and trading oil, greasy spots and applying one coat of white wash on walls including cornices, pillasters etc, complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified.
S & F in repair to Hollow PVC wall lining consisting of 5mm thick single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement and fixing on PVC frame as specified in MES schedule part-I & II complete all as specified.
S & F in repair of gypsum board 8 to 9 mm thick in ceiling fixed with screw 60x60cm placed in ceiling (Angle 25mm X 25mm, main tee 38mmX23mm, Sub tee 23mmX23mm) incl aluminium anodised/powder coated snap grid frame 605X605 mm for false ceiling incl hanging arrangement complete all as specified. Note:-The hanging stay wire shall not be less than 4.00mm thick all are included in the above mentioned item only.
S&F Factory made solid PVC door frame (having density not less than 600 kg/cum) of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube, complete all as specified in MES Schedule Part-I (2009),including making good jambs in CM(1:4) with finishes to match with existing, complete all as per specification & shown in drawing.
S&F Factory made solid panel PVC door shutter 30 mm thick (having density not less than 600 kg/cum) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site, complete all as per specification in MES Schedule Part-I (2009) & shown in drawing.
S&F PTMT butt hinges,100 mm long and fixed with steel screws complete all as specified.
S&F PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified.
S&F PTMT handle,125 mm long and fixed with steel screws complete all as specified.
S&F in repair rough cast wired glass, 6.40mm thick and glazing with oil putty in square n.exc 0.5 Sqm fitted in existing steel frame work in squares n.exc 0.50 Sqm, incl hacking out old unserviceable broken glass and putty/beading, complete all as specified.
S&F 3mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm, incl hacking out old unserviceable broken glass and putty/beading, complete all as specified.
S&F 3mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm complete all as specified.
S&F in repair galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples, complete all as specified .
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples, complete all as specified .
Disconnecting existing tanks, 500 litres capacity rotational moulded setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified.
Taking down door shutter of any description, exc 1 Sqm but not exceeding 2 sqm each and refixing in the same opening, complete all as specified.
Dismantling asbestos cement (corrugated or semi corrugated) sheets in roof coverings complete all as specified.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified.
M&L Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing, complete all as specified.
S&F 1.60mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood orsteel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified.
S&F rolled MS plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified.
S&F Mild Steel Framed work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified.
S&F Mild steel Screw bolts (machine made) with hexagonal or square heads at one end screwed the other or screwed both ends, each screwed end to be fitted with washers and one hxagonal or square nut not exceeding 5cm long but not exceeding 10cm long diameter of neck in 11 to 15mm dia complete all as specified and as directed
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engr-in-Charge.
M&L for Welding in repairs n. exc 2.5cm in length and thickness n exc 6 mm, complete all as specified.
S&F 1.25mm thickness of laths of steel rolling shutters of gear operated type with bevel gear box and crank handle with out ball bearing as specified including top cover anchoring rod hasp and staple and one shop coat of primer erected in position as indicated complete all as specified and directed by Engineer-in-Charge. Note:- Ball bearing for rolling shutters will be measured separately.
S&F ball bearing for rolling shutters, complete all as specified and directed by Engineer-in-Charge.
S&F bottom plate/patty 3 mm thick 125mm height including side lock at both end for rolling shutter of any type and description, fixed in position complete all as directed by Engr-in-Charge.
S&F safety lever locks mild steel with 4 levers and fixed in repairs for rolling shutters, complete all as directed.
M&L for removing loose and broken concrete by chiseling/picking etc upto a depth of 20 to 40mm from floor/roof slab and similar structural members cutting edges cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles etc and washing with clean water with pressure and removal of debries to a distance not exc 50m complete all as specified and directed by Engineer-in-Charge, including necessary scaffolding etc complete.
M&L for applying one coat epoxy bonding agent as per manufacturers insturction to old concrete surfaces prepared as per item (102) above all as specified and directed by Eng-in-Charge in surfaces of columns, beams, and similar structural members prepared as per item (102) above including use and waste of water tight form work to facilitate pouring of micro concrete complete all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of anti corrosive primer as per manufacturers insturctions to exposed old and new reinforcement to the full circumferences and length of bars to form unbroken 40micron thick film in the area prepared vide item no 102 above complete all as specified and directed by Eng-in-Charge.
M&L for application of high build polymer modified to floor and vertical wall up to sunken portion with cement mortar Plaster (1:3) with SBR @ 4 ltr per bag of cement applied as per manufacturer's instrutions, complete all as specified and directed .
Dismantling of brick tiles single layer jointed & pointed in cement mortar including removal of grass including roots, vegetation, complete all as specified.
Demolition of mud phuska in roofs, any thickness, including leeping plaster (whether full thickness removed or only a part thereof) complete all as specified.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting exc 10 cm not exc 20 cm girth, complete all as specified.
M&L for cement concrete tiles of size 25cmx25cmx22 mm thick as in roof set and jointed in neat cement slurry and pointed in grey cement no pigment laid over 15 mm thick screed in cement mortar (1:6) mixed with WPC, joints frouted and flush pointed in CM (1:3) mixed with 5% of crude oil weight of cement, complete all as specified. (WPC shall be measured and paid seaparately)
M&L for 40mm thick PCC type B-1 (1:2:4) using 20mm graded stone aggregate for bases of floor, complete all as specified.
Complete removal of existing roof treatment including concretes, plastering etc and cleaning the roof surface thoroughly free from dust loose particles etc. and make the surface to receive waterproofing treatment, complete all as specified.
M&L for brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified.
M&L for Rendering 10 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces mixed with WPC @ 3% by the weight of cement as in vertical surfaces, finished even and smooth without using extra cement, complete all as specified.(WPC shall be measured and paid seaparately)
M&L for screeding 10 mm thick in cement mortar (1:4) on any concrete surfaces mixed with WPC @ 2% by the weight of cement asper manufacture instruction, finished even and smooth without using extra cement, complete all as specified.(WPC shall be measured and paid seaparately)
M&L for Polymer modified bituminous membrane with sand witched polythene film/non woven polyster reinforcement/polymeric water proofing membrane 3Kg/sqm laid over hot blown grade 85/25@ 1.2kg/Sqm (i.e roof slab cleaned throughly to to remove all loose particle dust/dirt particle) shall be laid over entire roof surface and on verticle surface up to grooves (or as per manufacturers recommendation) with over laps of 100mm. The over lap shall be sealed by flames or as per manufacturer instruction. Hot blown bitumen grade 85/25 @1.2kg/Sqm applied over the membrane should be compatible with membrane all as recommendation of manufacturers and all as specified and directed.
M&L for Preparation of roof surface and apply one coat of bituminous aluminium primer @ 0.10 Kg/Sqm applied on treated bituminous membrane complete all as specified.
Demolition of brick work built in cement mortar of any specification and in any position complete all as specified.
M&L for Brick work in cement mortar 1:6 using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 metre mean radius, complete all as specified.
All as per item 118 hereinbefore but using old bricks retrieved from demolition under item 117 hereinbefore including cleaning and removal of mortar from old bricks complete all as specified.
Taking down carefully existing alumimium point wiring for light/fan/socket out let points complete with fitting and fixtures, battens, wire etc and making good the disturbed surfaces of walls and ceilings, complete all as specified.
S&F Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia )duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed,stranded (Green colour) connected to common earth dolly complete all as specified for following :- (a) One light/fan/exhaust point/bell controlled by one single pole one way switch.
(b) One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board .
(c) One 3 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per item 121 above but one switch socket outlet multi purpose, 3pin, 15 Amps, point to be controlled by one switch and wiring with 4 Sqmm PVC FRLS cable, insulated, stranded, unsheathed copper conductor on Independent board with continuous earth wire of size 4 sqmm, PVC copper conductor, insulated, unsheathed, stranded, complete all as specified
S&F Switch, piano, flush type, single pole one way, 5 Amps, ISI marked,complete all as specified.
S&F Switch piano flush button type 15 Amps, single pole, one way,ISI marked, complete all as specified.
S&F Socket outlet, 3 pin, 5 Amp, piano flush type, ISI marked, complete all as specified.
S&F Socket outlet 2 in 1, 6 pin,5 Amp and 15 Amp, piano flush type,ISI marked, complete all as specified.
S&F Bell push, flush type, 5 amp complete all as specified.
S&F Ceiling rose, surface type, backelite 65mmx50mm, 3 terminals, complete all as specified.
S&F bell Ding Dong AC 230 volts, single pole, complete all as specified.
S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 230 volts, complete all as specified.
S&F Exhaust fan AC single phase 230 Volts of 300mm sweep with louver plastic body, complete all as specified.
S&F Lamp holder, insulated body, threaded dome pattern, suitable for bracket/batten fittings, complete all as specified.
S&F LED bulb 10 watts suitable for fixing in lamp holder, complete all as specified.
S&F LED mirror light fitting 9 watts fixed on walls including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified.
S&F in repair of regular batten for LED tube 20W, 4 feet long indoor decorative batten with extruded aluminium housing & Opal diffuser energy efficient 230 Volts IP-20 fixed to walls/ceiling etc, complete all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified..
Supply & Fixing LED Bldg security light 45 watts lens type, pressure die cast aluminium housing, heat resistane toughened glass with frame, IP 66 protection with bracket (for housing street light fittings) made of GI pipe 25 mm dia light grade 1.0 mtrs long duly cutted and welded at an angle of 120 degree and fixed to wall with 50 mm X 6 mm MS clamps - 02 Nos with 16 mm dia bolts, nuts, and washers, complete all as specified and directed.
S&F and testing LED flood light 70 watts, pressure die cast aluminium housing, heat resistane toughened glass with frame, IP 65 protection with 5 KV surge protection, complete all as specified and directed.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 2x4 Sqmm single core 650/1100 V, drawn through & including rigid PVC non metallic concealed conduit 25 mm dia including continuous earth wire of size 1x4sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour) complete all as specified. NOTE:- Two runs of cable, 1 run of earth wire & one run of PVC conduit shall be measured as one length.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 2x6 Sqmm single core 650/1100 V, drawn through & including rigid PVC non metallic concealed conduit 25 mm dia including continuous earth wire of size 1x6 sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour) complete all as specified. NOTE:-Two runs of cable,1 run of earth wire & one run of PVC conduit shall be measured as one length.
S&F in repair Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, concealed in wall, TPN DB with 200 Amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof,suitable for incorporation of MCBs duly concealled in wall, factory made,including making good distrubbed surfaces with matching colour, complete all as specified.
S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet,powder coated, SPN DB with 200 Amps rated bus bar, 8 way, FP-42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCCBs duly concealled in wall, factory made,including making good distrubbed surfaces with matching colour, complete all as specified.
All as per item no 143 above, but SPN DB 4 way, complete all as specified.
S&F of MCCB Thermal based release adjustable type 4 pole 100 Amps 50 HZ 415 Volts with rupturing capacity 16 KA including testing, complete all as specified and as directed.
S&F in repairs MCB, single pole, 240 Volt, 32 Amps,10 KA 'B' series, complete all as specified.
S&F in repairs MCB, SPN, 40 Amps, 240 volts 6 to 32 Amps10 KA 'B' series, complete all as specified.
M& L Earthing as in repairs complete, all as shown on electrical plate No 3 of MES schedule part-I, as in repairs and as specified including the following :- (i) Galvanised steel earth plate of size 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level.(ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer).(iii) 4 mm dia (8 SWG) G.I earth wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc.(iv) 15 mm bore light grade, GI pipe for protection to earth-strip.(v) 20mm bore, medium grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces. (vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed.
S&F as in repairs XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 25 Sqmm nominal cross section, 4 core, flat or circular, PVC FRLS insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC FRLS sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified .
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan,for laying of cable and getting out, compete all as specified.
Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified.
Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified.
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately).Note- Punned down thickness shall be measured.
S&F in repair Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified. (Excavation and earth work measured separately).
S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/laid under floor/road crossing/walls complete with and including clamps socket & elbow etc complete all as specified.
M/s Sanjiv Kumar
Niraj Kamal Sharma
M/s Surjit Singh and bros
GS and Co
M/s Bansi Lal
M/S Yashpaul Gulati
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .