Tender Value
₹20.8 L
EMD Value
₹20,845
Closing Date
2 Mar 2024, 12:00 pmClosed
Superintending Engineer EUDC 1 Ghaziabad
HYDEL COLONY, A BLOCK KAVI NAGAR, GHAZIABAD
Work of Installation of new VCB at various site Under Business Plan Scheme 2023-24 on Semi Turnkey Basis in the Area of EE, EUDD-I EUDD-V and EUDD-IX Ghaziabad. Under the jurisdiction of SE, EUDC-I, Ghaziabad.
2024_PVVNL_903145_1
73/2023-24/EUDC-I/GZB
Open Tender
Electrical Works
Item Rate
90 days
Ghaziabad
Please Refer Tender Documents
2 documents required · 2 mandatory
₹3,540
Superintending Engineer EUDC 1 Ghaziabad
₹20,845
4 Mar 2024
23 Feb 2024
2 Mar 2024
23 Feb 2024
2 Mar 2024
23 Feb 2024
Amount
Carriage of XLPE Cable 3x300sqmm from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB I/C CTR 600/300/5A,350 MVA,24 volt from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB For O/G CTR 200/100/5A,350 Mva, from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB For O/G CTR 600/300/5A,350 Mva, from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV BUS COUPLER from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV VACCUM CIRCUIT BREAKER 1250 AMP from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Control Pannel I/C for 33KV VCB Double T/F from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of CT 400/200/1 from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV VCB 1250Amp from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of PT 33KV Outdoor(33KV/110) from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Dismantling of 11 KV VCB Outgoing 200/100/5A, 350 MVA and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of 11 KV VCB Incomming 600/300/5,350 MVA and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of 11 KV VCB I/C CTR 600/300/5A,350 MVA,24 volt and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of 11 KV VCB O/G CTR 600/300/5A,350 MVA,24 volt and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of 11 KV VCB For O/G CTR 200/100/5A,350 Mva, and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of 11 KV BUS COUPLER and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of 33 KV VACCUM CIRCUIT BREAKER 1250 AMP and Safley carriage from work site to Store center/JE store loading and unloading both side.
Safely placing/Fixing & Commissioning 11 KV VCB I/C CTR 600/300/5A,350 MVA,24 volt at various site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning 11 KV VCB For O/G CTR 200/100/5A,350 Mva, at various site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning 11 KV VCB For O/G CTR 600/300/5A,350 Mva, at various site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning 11 KV BUS COUPLER at various site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning 33 KV VACCUM CIRCUIT BREAKER 1250 AMP at various site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning Control Pannel I/C for 33KV VCB Double T/F at site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning CT 400/200/1 at various site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning 33 KV VCB 1250Amp at various site complete in all respect as per RESPO norm.
Safely placing/Fixing & Commissioning PT 33KV Outdoor(33KV/110) at various site complete in all respect as per RESPO norm.
Laying, Lifting and sagging of 11 kv XLPE cable 3x300 sqmm at various site with all accessories complete in all respect as per RESPO norm.
Providing and 11 KV Deep Water Level Earthing at various site complete in all respect as per RESPO norm.
Supply & fixing Nut & Bolt off size at various site complete in all respect as per RESPO norm.
Supply & fixing 4x2.5 sqmm Control Cable Armoured at various site complete in all respect as per RESPO norm.
Supply & fixing 2x2.5 sqmm Control Cable at various site complete in all respect as per RESPO norm.
Supply & fixing Outdoor Cable Box J/K 3x300 sqmm at various site complete in all respect as per RESPO norm.
Providing and Construction of Plinth Foundation of VCB at various site complete in all respect as per RESPO norm.
Supply & fixing Steel Structure at various site complete in all respect as per RESPO norm.
Supply & fixing 33KV TPMO Set at site complete in all respect as per RESPO norm.
Providing and Panting of Substation Structure at site complete in all respect as per RESPO norm.
All other works complete in all respect as per site requirement.
R. P. T. Electrical
M/S S.K. MANAGEMENT SERVICES PVT LTD.
AAYANSH ELECTRICAL SOLUTIONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .