Loading…
Loading…
Tender Value
₹15.6 L
EMD Value
₹32,000
Closing Date
28 Sept 2026, 3:00 pmDue tomorrow
EEE/North Zone
EEE/North Zone
Providing, Repairing, and Maintenance of Electrical Installation (EI) and Ceiling Fans at MPL Community Hall, EE Block, Jahangir Puri, Ward No. 08, under Civil Lines Zone.
2026_MCD_291540_1
EEE-II/TC/2026-27/27.1
Open Tender
Electrical Works
Percentage
45 days
EEE/North Zone
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹32,000
21 Sept 2026
21 Sept 2026
28 Sept 2026
21 Sept 2026
28 Sept 2026
21 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | 127 | Each | 1,704 | ₹2,16,408 |
| 2.001 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. | 120 | Each | 1,064 | ₹1,27,680 |
| 3.001 | Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep | 15 | Each | 556 | ₹8,340 |
| 4.001 | Supply of 12" (300 mm ) sweep exhaust fan heavy duty complete with shutters blade etc as required. | 15 | Each | 2,567 | ₹38,505 |
| 5.001 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole | 40 | Each | 285 | ₹11,400 |
| 6.001 | SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color | 1 | Each | 2,565 | ₹2,565 |
| 7.001 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door | 4 | Each | 2,871 | ₹11,484 |
| 8.001 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 2 | Each | 472 | ₹944 |
| 9.001 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 2 | Each | 569 | ₹1,138 |
| 10.001 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 16 KA,TPMCCB | 3 | Each | 4,003 | ₹12,009 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
GeneralConditions.pdf
Tender Documents • 0.20 MB
MCD_GCC_2026Latestcirculars.pdf
Tender Documents • 16.29 MB
BOQ_339984.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .