Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.5 CrAccepted-AOC KHUDUS | MALSHIRAS | SOLAPUR | MAHARASHTRA | ₹4.5 Cr | 1 | Accepted-AOC ac |
| 2 | 2₹4.5 CrRejected-AOC N A | ₹4.5 Cr | 2 | Rejected-AOC re |
| 3 | 3₹4.5 CrRejected-AOC 1551 SUBHASH NAGAR BARSHI TAL BARSHI DIST SOLAPUR | BARSHI | SOLAPUR | MAHARASHTRA | ₹4.5 Cr | 3 | Rejected-AOC re |
Tender Value
₹4.5 Cr
EMD Value
₹4.5 L
Closing Date
18 Feb 2026, 5:00 pmClosed
Add ceo zp solapur
ee bnc 2
as above
2026_SOLAP_1276581_1
CONSTRUCTION OF STAFF QUARTERS FOR P.H.C.MAIN BUILDING at Gurasale, Tal - Pandharpur,
Open Tender
Civil Works
365 days
solapur
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,000
₹4.5 L
2 Apr 2026
10 Feb 2026
20 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift Upto3.00 M.) By Manual Means SSR Pg No./It No. 153/720/21.01/BDA1 Spec. No. : Bd A.1 Page No. 259 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Excavation for foundation in hard murum including removing the excavated material up to a distance of 50 m. beyond the building area & stacking and spreading as directed dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete ( Lift Upto 1.5 m) By Manual Means. SSR Pg No./It No. 153/725/21.06/BDA2 Spec. No. : Bd A. 2 Page No. 259 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Excavation for foundation in hard & Boulders murum including removing the excavated material up to a distance of 50 m. beyond the building area & stacking and spreading as directed dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete ( Lift Upto 1.5 m) By Mechanical Means. SSR Pg No./It No. 154\728/21.10/BDA3 Spec. No. : Bd A. 3 Page No. 259 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. SSR Pg No./It No. 155/737/21.22/BDW Spec. No. : As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametreabout30percent of Clorophysiphas/ 20 E.C. Heptaclor at the rate of 7.5 litres emulsion concentrate per hole and sealing the same with proper filling & covering 10 years guarantee. SSR Pg No./It No. 156/740/21.25/BDW Spec. No. : As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing dry/trap/granite/quartzite/gneiss rubble stone soiling 15 cm to 20 cm, thick including hand packing and compacting complete. SSR Pg No./It No.157/752/21.38/BDA12 Spec. No. Bd. A 12 Page No. 264 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying Casting in situ,/ Ready mix concrete cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel Centering ,formwork, laying / pumping, compacting,roughening them if special finish is to be provided,finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggrigate (Crushed sand VSI Grade finally washed etc.) SSR Pg No./It No. 175/827/24.01/BDE1 Spec. No. Bd. E. 1 Page No. 287 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
INTERNAL ROAD
Providing and laying in situ/ Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundationslike raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, cover blocks compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) complete, With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggrigate ( Crushed Sand VSI Grade finally washed etc ) SSR Pg No./It No.178/836/25.11/BDF3 Spec. No. Bd. F. 3 Page No. 298 and B-7 Page No. 38 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing and casting in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer / concrete Batch mix plant (Pan mixer) etc. complete.With fine aggrigate (Crushed Sand VSI Grade finally washed etc ) SSR Pg No./It No.179/841/25.31/BDF5 Spec. No.:Bd. F. 5 Page No. 300 and B-7'Page No.38 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing & casting in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs & drawings or as directed including centering, formwork, cover blocks compaction & roughening the surface if special finish is to be provided & curing complete. (Excluding reinforcement). With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggrigate (Crushed Sand VSI Grade finally washed etc ) SSR Pg No./It No.181/846/25.50/BDF6 Spec. No. : Bd.F.6Page No.300 and B-7, Page No. 38 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggrigate (Crushed Sand VSI Grade finally washed etc ) SSR Pg No./It No. 185/862/26.23/BDF12 Spec. No.Bd. F. 12 Page No. 304 and B- 7, Pg 38 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing & casting in situ cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design & drawings including centering, formwork, cover blocks compacting & roughening the surface if special finish is to be provided & curing complete. (Excluding reinforcement).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggrigate ( Crushed Sand VSI Grade finally washed etc ) SSR Pg No./It No. 184/856/26.05/BDF9 Spec. No. : Bd.F.9 Page No.303 and B-7, Page No. 38 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and casting in situ cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi 75mm thick fins including centering, formwork, cover blocks compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement).with reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggrigate (Crushed Sand VSI Grade finally washed etc ) SSR Pg No./It No.185/860/26.17/BDF11 Spec.No. :Bd. F.11 Page No.304.and B-7,Page No. 38 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing and casting in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings canopy, waist slab with steps as per detailed designs and drawings including centering, formwork, cover blocks compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer / concrete Batch mix plant (Pan mixer) etc. complete.With fine aggrigate (Crushed Sand VSI Grade finally washed etc ) SSR Pg No./It No.182/851/25.70/BDF8 Spec. No. :Bd.F.8 Page No. 302 and B-7, Page No.38. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) SSR Pg No./It No.186/864/26.26/BDF13A Spec. No. :Bd.F.8 Page No. Bd. F. 13 Page Number 305 /I.S. 456 (2000). TYPE-I
TYPE-II
TYPE-III
Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches etc. as per detailed desings, drawings and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. SSR Pg No./It No. 188/871/26.33/BDF17 Spec. No. : Bd.F.17, Page No. 306. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls including bailing out water, striking joints on unexposed faces, racking out joints on exposed faces and watering, Complete. SSR Pg No./It No.197/889/27.01/BDG1 Spec. No. Bd.G.1 Page No. 313 TYPE-I
TYPE-II
TYPE-III
Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls including bailing out water, striking joints on unexposed faces, racking out joints on exposed faces and watering, Complete. SSR Pg No./It No.197/889/27.01/BDG1 Spec. No. Bd.G.1 Page No. 313 POST MORTOM
Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding etc Complete. SSR Pg No./It No.197/892/27.05/BDG5 Spec. No. Bd.G.5 Page No. 315. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm x 1.6 mm at every third course, properly bend and bonded at ends scaffolding, racking out joints and watering complete. SSR Pg No./It No.197/893/27.06/BDG7 Spec. No. : Bd.G.7 Page No. 316. TYPE-I
TYPE-II
POST MOTOM ROOM
Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm x 1.6 mm at every third course, properly bend and bonded at ends scaffolding, racking out joints and watering complete. SSR Pg No./It No.197/893/27.06/BDG7 Spec. No. : Bd.G.7 Page No. 316. TYPE-III
Filling in plinth and floors with approved excavated materials in 15 cm to 20 cm layers including watering and compaction complete. SSR Pg No./It No.157/750/21.36/BDA10 Spec. No. Bd. A 10 Page No. 262. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Filling in plinth and floors with contractor’s material / brought from out side and approved by engineer incharge in layer of 15 cm to 20 cm including watering and compaction. Etc complete. SSR Pg No./It No.157/751/21.37/BDA11 Spec. No. Bd. A 11 Page No. 263. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing preconstructional antitermite treatment as per I. S. 6313 ( Part -II ) by treating the top surface of plinth filling at the rate of 5 liters of emulsion concentrates of 0.5% of Hephoclore per square meter of surface area covering 10 years guarantee. SSR Pg No./It No. 156/739/21.24/BDW Spec. No. : As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. SSR Pg No./It No. 210/977/32.26/BDL Spec. No. :As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing internal cement plaster 6 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete. SSR Pg No./It No. 209/956/32.02/BDL1 Spec. No. : Bd.L.1 Page No. 367. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete. SSR Pg No./It No. 209/959/32.05/BDL2B Spec. No. : Bd.L.2 Page No. 368. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing internal cement plaster 20 mm thick in two coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete. SSR Pg No./It No. 209/961/32.07/BDL4B Spec. No. : Bd.L.4 Page No. 368. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. SSR Pg No./It 212/985/32.34/BDL Spec. No.: As Directed By Engineer Ingharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. SSR Pg No./It No. 209/963/32.11/BDL7 Spec. No. : Bd.L.7 Page No. 369 . TYPE-I
TYPE-II
TYPE-III
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. SSR Pg No./It No. 209/963/32.11/BDL7 Spec. No. : Bd.L.7 Page No. 369 . POST MORTOM ROOM
COMPOUND WALL
Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. SSR Pg No./It No. 210/975/32.24/BDL Spec. No. : As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing vee pointing with cement mortar 1:3 for stone / Brick masonry including scaffolding and curing etc. complete SSR Pg No./It No. 210/971/32.20/BDL18 Spec. No. : Bd. L. 18 Page Number 373. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. SSR Pg No./It No.205/940/31.04/BDJ Spec.No.As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. SSR Pg No./It No.205/941/31.05/BDJ Spec.No.As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying handcut polished Kotah Stone flooring 25mm to 30mm thick and 30cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. SSR Pg No./It No.213/994/33.07/BDM Spec. No.: Bd.M. 3 Page No. 380 . TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring SSR Pg No./It No.216/1015/33.28/BDM Spec. No.: As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. SSR Pg No./It No.221/1059/33.81/BDM Spec. No.: As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Skirting. SSR Pg No./It No.216/1016/33.29/BDM Spec. No.: As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. SSR Pg No./It No.215/1005/33.18/BDM22B Spec.No.Bd.M.22B Page No.390. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying Vitrified MATT finish having decorative type of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete. SSR Pg No./It No.219/1046/33.59/ Spec. No.: Bd.M. 12 Page No. 386 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying vitrified matt finish tiles of having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning complete. b) Skirting SSR Pg No./It No.217/1030/33.43/BDM12 Spec. No.: Bd.M. 12 Page No. 385 . TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.. SSR Pg No./It No.220/1051/33.67/BDM Spec. No. Bd. M.12 Page No. 385. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying ceramic tiles of having size 30cmX30cm and confirming to corresponding I.S. for dado & skirting in required position with ready made adhesive morter of app. quality on plaster of 1:2 C.M. including filling joints with white/colour cement slurry, curing, cleaning etc complete. SSR Pg No./It No.215/1012/33.25/BDM13 Spec. No. Bd. M.13 Page No. 386. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. SSR Pg No./It No.220/1052/33.68/BDM Spec.No.As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 60 mm thickness of having a strength of 300 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. SSR Pg No./It No. 218/1038/33.51/BDM Spec. No. As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing green marble of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. SSR Pg No./It No.218/1035/33.48/BDM12 Spec.No.Bd-M-12. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. SSR Pg No./It No.245/1195/39.02/BDT Spec. As directed by Engineer in charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing partition with kadappa stone of all size and 25mm thick polished on both side and edge to original induding fixing in position in cement mortar 1:4 curing, polishing and cleaning etc complete. SSR Pg No./It No. 277/1400/42.29/BDV Spec. : As directed by Engineer in charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) SSR Pg No./It No.273/1369/41.78/BDV Spec.No As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing solid core flush door shutter commercial in single leaf 32mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. SSR Pg No./It No.246/1203/39.10/BDT36 Spec.No.BDT-36 Page No.500. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing 30mm thick PVC FLUSH L DOOR SHUTTER consisting of panel of hollow PVC profile of 20 mm thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mminserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 mm MS tubes inserted horizontally inside the hollow profile section using 4/5 mm sheet using screws hollow profile shall be lipped with 10 mm (5mm x2) thick x 20 mm width on stiles and rails using solvent cement. The inner panel shall be laminated with 5mm thick termite proof waterproof plain /prelam PVC sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. SSR Pg No./It No.262/1277/39.82/BDT Spec. As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5mm thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts etc, complete with poweder coating with box SSR Pg No./It No.254/1236/39.43/BDT Spec. As directed by Engineer In Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38mm x 1.22mm box type, 5mm thick sheet glass louvers, of approved quality etc. complete. SSR Pg No./It No.259/1263/39.68/BDT Spec.No. As directed by Engineer in charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing mild steel grill work for windows, ventilators, etc. 20 kg/sq.m as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. SSR Pg No./It No. 264/1291/40.01/BDU1 Spec. No. : Bd.U.1 Page No. 537. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kg/sq.m as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. SSR Pg No./It No. 264/1292/40.02/BDU1 Spec. No. : Bd.U.1 Page No. 537. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer & oil painting etc. complete. (I.S. 10521-1983). SSR Pg No./It No. 249/1219/39.26/BDT57 Spec. No. : Bd.T. 57 Page No. 511. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing fine cement finish 1.5 mm th. Over green plaster surface including scaffolding and curing complete. SSR Pg No./It No.210/972/32.21/BDL Spec. No. As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. SSR Pg No./It No.277/1404/42.33/BDV Spec. No. As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. SSR Pg No./It No. 277/1405/42.34/BDV Spec. : As directed by Engineer in charge. TYPE-III
POST MOTOM ROOM
Providing and fixing coloured glazed earthenware Wash Hand Basin of 55cm x 40 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. SSR Pg No./It No. 272/1360/41.66/BDV30 Spec. : No. Bd.V.30 Page No.565. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing 15 mm dia screw down bib/stop tap of brass including nessesary sockets, union nuts complete. SSR P.No.270/1334/41.40/BDV8 Spec.No.BdV 8 Page No. 554. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete SSR P.No.2270/1337/41.43/BDV9 Spec.No.BdV 9 Page No. 555. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. SSR P.No.230/1385/42.20/BDV Spec.No.BdV 9 Page No. 555. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing 10cm PVC Nahani Trap With greating etc. complete. SSR P.No.281/1438/42.67/BDV32 Spec.As directed by Engineer Incharges. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with R.C.C. Cover meadium duty 140kg with frame etc complete. SSR P.No.275/1383/42.12/BDV43 Spec.No.BdV 43 Page No. 574 . TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing & constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with R.C.C. Cover meadium duty 140kg with frame etc complete. SSR P.No.229/1378/42.13/BDV43 Spec.No.BdV 43 Page No. 574 . TYPE-I
TYPE-II
TYPE-III
Providing and casting 15X10cm salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron greating in the sink conceting glazed stoneware pipe , brick masonry chamber eith cast iron lid and iron greating for the gully trap. SSR Pg No./It No.274/1373/42.02/BDV38 Spec. No. : Bd. V.38 Page No.572. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing C.P.wall mixer with provision for over head shower with 115 mm long bend pipe and wall flange of approved make in cluding necessary sockets / union nut etc.complete. SSR P.No.282/1452/42.81/BDV Spec.No. As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing on Walls/Ceiling/Floor 15mm Dia CPVC pipe with necessacery fittings,remaking good the demolished portion etc. complete. complete.Including removing existing pipe line if necessacery and conveying and stacking the same in PWD chowaky or as directed etc.complet . SSR Pg No./It No. 280/1426/42.55/BDV Spec.No. BDV5 Page No.551 As Directed By-In-Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing on Walls/Ceiling/Floor 20mm Dia CPVC pipe with necessacery fittings,remaking good the demolished portion etc. complete. Including removing existing pipe line if necessacery and conveying and stacking the same in PWD chowaky or as directed etc.complet . SSR Pg No./It No. 280/1427/42.56/BDV5 Spec. As Directed By-In-Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing on Walls/Ceiling/Floor 25mm Dia CPVC pipe with necessacery fittings,remaking good the demolished portion etc. complete. Including removing existing pipe line if necessacery and conveying and stacking the same in PWD chowaky or as directed etc.complet . SSR Pg No./It No. 280/1428/42.57/BDV5 Spec. As Directed By-In-Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing trenchs 15mm Dia CPVC pipe including necessacery excavation , fittings,refilling trench etc.complete. Including removing existing pipe line if necessacery and conveying and stacking the same in PWD chowaky or as directed etc.complet . SSR Pg No./It No. 280/1432/42.61/BDV5 Spec. No.BDV5 , Page No.551 & As Directed By-In-Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing trenchs 20mm Dia CPVC pipe including necessacery excavation , fittings,refilling trench etc.complete. Including removing existing pipe line if necessacery and conveying and stacking the same in PWD chowaky or as directed etc.complet . SSR Pg No./It No. 280/1433/42.62/BDV5 Spec. No.BDV5 , Page No.551 & As Directed By-In-Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing trenchs 25mm Dia CPVC pipe including necessacery excavation , fittings,refilling trench etc.complete. Including removing existing pipe line if necessacery and conveying and stacking the same in PWD chowaky or as directed etc.complet . SSR Pg No./It No. 280/1434/42.63/BDV5 Spec. No.BDV5 , Page No.551 & As Directed By-In-Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing H.D.P. container syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting fixing of accessories such as inlet, outlet, overflow inclusive of all taxes Capacity between 200 To1000 lit. SSR P.No.280/1424/42.53/BDV Spec.As directed by engineer in charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. SSR P.No.282/1449/42.78/BDV4 Spec.No.As Directed By Engineer Incharge. POST MORTOM
Providing laying & fixing 75 mm dia.Stabeliser pipe / PVC Soil vent / West pipe and With necessacery Fixtures and fastening such as bends, single junction slotted vent clamp etc.complet. SSR Pg No./It No. 279/1422/42.51/BDV Spec.As directed by engineer in charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing laying & fixing 100 mm dia.Stabeliser pipe / PVC Soil vent / West pipe and With necessacery Fixtures and fastening such as bends, single junction slotted vent clamp etc.complet. SSR Pg No./It No. 279/1423/42.52/BDV Spec.As directed by engineer in charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying concrete pipes of I.S.NP.class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. SSR Pg No./It No. 274/1380/42.09/BDV41 Spec. No.Bd.V.41/Page No.573 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and laying concrete pipes of I.S.NP.class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. SSR Pg No./It No. 274/1379/42.08/BDV41 Spec. No.Bd.V.41/Page No.573 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. etc. complete. SSR Pg No./It No.275/1390/42.19/BDV46 Spec.No.Bd.V.46 Page No.576. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and applying washable oil-bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat.) complete. SSR Pg No./It No. 227/1106/36.11/BDP5A Spec. No. : Bd. P. 5 Page No. 413. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and applying priming coat concret / masonry / asbestos cement plastered surfaces including scaffolding if necessary , preparing the surface by throughly cleaning / oiled / grees / dirt and other farain matter and sand papering as required. SSR Pg No./It No. 225/1090/35.21/BDO 8E Spec. No. : As directed by engineer in charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and applying Plastic Emulsion paint of approved quality ,colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat.) complete. SSR Pg No./It No. 227/1107/36.12/BDP6 Spec. No. : Bd. P. 6 Page No. 414 & Pre Approval Of Superitendering Engineer TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. SSR Pg No./It 225/1093/35.24/BDO Spec.No.:As Directed by Engineer- In Charge. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. SSR Pg No./It No. 23/85/2.09/MORTH 201 Spec. No. MORTH 201 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mm x 40 mm weighing 0.39 kg/m. at 60 cms c/c and fixed with ( 15 x 15 mm) flanges weighing 0.119 kg/m suspended on 6 mm dia. mild steel rod weighing 0.22 kg/m fixed on wall and beams including rounding of the edges with aluminium T of 50 mm x 40 mm weighing 0.39 kg/m etc. including all labour etc. complete. SSR Pg No./It 234/1154/38.14/BDR Spec.No.:As Directed By Engineer Incharge. TYPE-I
TYPE-II
TYPE-III
Providing and fixing false ceiling of 10 to 12 mm thick decorative boards of fibrous plaster of paris including scaffolding if necessary all architectural work like mouldings, cornices, coves, domes, cups as per detailed drawings and three coats of spray painting to boards etc. complete. (excluding frame work, runners and mild steel suspenders). SSR Pg No./It 235/1158/38.18/BDR 19 Spec.No.:Bd. R. 19 Page Number 462 TYPE-I
TYPE-II
TYPE-III
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge SSR Pg No./It No.317/1662/48.46 Spec.No.AsDirected By Engineer Incharge TYPE-III
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make All works the drawing technical direction the Engineer in SSR Pg No./It No.317/1663/48.47 Spec.No.AsDirected By Engineer Incharge TYPE-III
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.. SSR Pg No./It No. 317/1664/48.48/ Spec.No.:As directed by Engineer Incharge. POST MORTOM ROOM
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.. SSR Pg No./It No. 318/1665/48.49/ Spec.No.:As directed by Engineer Incharge. POST MORTOM ROOM
Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures & fittings in two leaves with strong hold fast embedded in c.c. block at top & bottom with locking arrangement including cutting, bending, making holes and with one coat of primer complete. complete. SSR Pg No./It No. 173/820/23.05/BDC Spec. No. :As directed by engineer incharge COMPOUND WALL
Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle ( 50 x 50x 6mm) post at 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in ( 1:4:8) cement concrete block of 45x45x45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete. SSR Pg No./It No. 294/1528/44.13/BDW Spec.No.:Bd.W. 3 Page No. 583 COMPOUND WALL
Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary cleaning and preparing the surfaces, watering for two days complete. SSR Pg No./It No. 224/1083/35.13/BDO8 Spec.No.:Bd.O. 8 Page No. 406 COMPOUND WALL
Excavation for roadway in earth, soil of all sorts, sand, graval or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. SSR Pg No./It No. 23/87/2.11/MORTH301 Spec. No. : MORTH 301 INTERNAL ROAD
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller to the required density.By Mechanical Means- Grading II (Using Screening type A 11.2) mm Aggregrate ) SSR Pg No./It No. 29/130/3.20/MORTH404 Spec. No. : MORTH 404 INTERNAL ROAD
Providing and laying in situ / ready mix M-20 cement concrete of trap / granite/ quartzite / gneiss metal for approach slab including compacting,finishing ,curing etc. complete ( excluding reinforcement ) ( with reversible Drum Type mixer / concrete batch mix plant (pan mixture ) with SCADA With Natural Sand./ VSI standered artificial sand, finaly washed etc ) cement 6.40 bag/cumt) SSR Pg No./It No.82/400/11.25/CD Spec.No.CD.15Page No.168 and B-7 Page No.38 INTERNAL ROAD
Supplying hard murum/kankar at the road site, including conveying and stacking complete. SSR Pg No./It No. 25/102/2.29a INTERNAL ROAD
Spreading hard murum/ soft murum/gravel or kankar for side width etc. complete. SSR Pg No./It No. 25/104/2.30 INTERNAL ROAD
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. SSR Pg No./It No. 25/105/2.31 INTERNAL ROAD
Providing and laying cement concrete pipe of IS458:2003 NP-2 class of 900mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. SSR Pg No./It No. 81/387/11.11/CD7 Spec. No.CD.7 Page.No. 162 INTERNAL ROAD
Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. SSR Pg No./It 43/185/5.17/MORTH602.63. Spec.No. INTERNAL ROAD
Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.. SSR Pg No./It 43/183/5.15/MORTH602.63. Spec.No.: INTERNAL ROAD
Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 mOne Metric Tonneo 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide) SSR Pg No./It 44/186/5.18/MORTH 602.6.3 & 602.6.4 Spec.No.: INTERNAL ROAD
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. SSR Pg No./It 44/186/5.18/MORTH 602.6.3 & 602.6.4 Spec.No.: INTERNAL ROAD
Providing and fixing 90 cm. x 60 cm. Granite plate engraving 10cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete. SSR Pg No./It 294/1527/44.12/BDW7 Spec.No.:Bd.W.7 Page No.586. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
TYPE-II
TYPE-III
POST MOTOM ROOM
Painting letters upto 20 cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. SSR Pg No./It No. 46/205/6.05/MORTH801 Spec. No. :MORTH 801, TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
ADD FOR OTHER MINERALS ROYALTY CHARGES , TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
INTERNAL ROAD
Test of Cement - Standard Consistancy Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness SSR Pg No./It No. 584/1. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Test of Fine Aggregate -Silt Factor. SSR Pg No./It No. 584/12. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
INTERNAL ROAD
Basic Test of Aggregate -Sieve Analysis. SSR Pg No./It No. 584/3. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
INTERNAL ROAD
Test of Bricks -Water Absorption (Set of 5 Bricks). Compressive Strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks) SSR Pg No./It No.584/13. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Test of Concrete - Compressive Strength OF C.C. M10,C20 Cube (Set of 3 cubes) SSR Pg No./It No.584/19. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
INTERNAL ROAD
Test of Concrete -Concrete mix design by Accelerated curing method. (By Accelerated curing method) SSR Pg No./It No. 584/23. TYPE-I
TYPE-II
TYPE-III
Test of Mortor - Compressive Strength OF C.C. Cube (Set of 3 cubes) SSR Pg No./It No. 585/27 TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Test of Steel 6mm,8mm,10mm,12mm,16mm dia -Tensile strength , %, Elongation, Yield Stress, Weight -Per Meter, Bend/ Rebend Test, Proof Stress. SSR Pg No./It No. 586/72. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
Test of Paving Block - Water Absorption, Moduls of Rapture (Set of 6 Tiles) SSR Pg No./It No. 584/26. TYPE-I
TYPE-II
TYPE-III
Test of Murum -Sieve Analysis . SSR Pg No./It No. 585/29. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
Test of Ceramic Tiles / Vetrified Tiles - Water Absorption, Moduls of Rapture (Set of 6 Tiles) SSR Pg No./It No. 584/16. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
ADD 18.00% FOR G.S.T. CHARGES Rs. TYPE-I
TYPE-II
TYPE-III
POST MOTOM ROOM
COMPOUND WALL
INTERNAL ROAD
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.71 MB
BOQ_2196723.xls
BOQ • 0.82 MB
SBD.pdf
Tender Documents • 2.01 MB
Download all tender documents and submit your bid