MOH, KDMC, Kalyan
KDMC, Kalyan
Tender for Purchase of Medical Equipment and Other Items
2020_KDMC_620071_1
KDMC/HEALTH/20-21/13
Open Tender
Medical Equipments/Waste
Item Rate
365 days
Kalyan Dombivali Municipal Corporation Area
Please refer Tender documents.
6 documents required · 6 mandatory
₹11,200
₹1 L
23 Mar 2021
29 Oct 2020
6 Nov 2020
29 Oct 2020
5 Nov 2020
29 Oct 2020
Amount
Computed Radiography (CR) System : Should be table top model,Should have Scanning Speed of atleast 45 PPH or More for 14"x17 " Size Cassette.Should Support minimum cassette size of 10"x12" &14"x17" for Scanning.Should Supply following Size of cassette ,screen with the system. Cassette with Screen 14"x17" -05 Nos Cassette with Screen 10"x12" -02 Nos .the scanner should have ability to place vertical as well as horizontal and compact model,Scanner should be atleast 14 bit or more . PC work station -01 Nos.Scanningsoftwere -01 Nos.the scanning software should have ability of scanning and ablity of printing both. Should supply UPS of minimum 3KVA with inbuilt batteries
FILM PRINTER: Should have capacity to read atleast 320 pixel per inch or more.Should be DICOM printer with laser technology .Should have the capacity to pressure automatic image quality.Should have capacity to hold atleast single tray online film packet.Should have minimum 14 bit pixel depth or more.Should have daylight film loading facility.Should have film packet of 125 sheet per cartidges,ability to print all type of film size 8x10,10x12,11x14,14x17.
MOBILE HIGH FREQUENCY X-RAY MACHINE : Should be mobile high frequency 6kw generator or more.Should be mobile machine with mA range -100mA,mAs range 0 to 250 mAs,Kv range -40-110 kvpmachine.Should be easy in operation with APR programming.
Laser X-Ray Films for Fuji Film CR System Size 8"x10"
Laser X-Ray Films for Fuji Film CR System Size 10"x12"
Digital X-Ray films CarestreamDVE8”x10” (125 Sheets Packetes)
Digital X-Ray films CarestreamDVE10”x12” (125 Sheets Packetes)
Digital X-Ray films CarestreamDVE11”x14” (125 Sheets Packetes)
E.C.G. Machine - 12 Lead – Abilty to display 12 channel display format,Display Screen should be atleast 8 inch or more.the A/D resolution should be 24 bit or more with touch screen amd function buttons.atleast 800 patient memory storage capacity.should have an inbuilt thermal printer to get the recording print.the print out format should be auto and maual mode both Ability to measure -HR,P-R interval,P duration, QRSduration,TDuration,Q-T interval,Q-Tc,P-Axis,QRSAxis,T-Axis,R(VS) amplitude,S(V1) amplitude,R(V5)+S(V1) amplitude.
Foam Mattresses 4" width 15 kg withrexin cover. Bed Size
Foam Pillow (1.5 kg) Size 16" X 22"
Automatic Films Processors - film Processor should be a table top model,Should have a capaciy to print to min 10x10cms and maxi 35 x inf.cms,the processor should be compatible with sheet and roll type of films,Process time should be atleast be 90-180 ses, Ability to hold a tank volume atleast D/F/W : 5/5/5 ltr (1.3/1.3/1.3 gal)
Wireless FPD System ( Direct Radiography) - the X-ray Detector should be wireless DR detector with Size : 14'' x17'' Qty-01 ,It should be wireless connectivity to eliminate the haseless and hazards of cables and reducethe risk of infection. The detector should be Direct deposit Csi with low dose solution.It should have rating of atleastIP54 rating to protect from dust and water.Cycle time should be minimum 6 sec for faster operation and diagnosis.It should be light weight ,not more than 3kg with hand grips to handle it well.Wireless Dr flat panel detector should have Resolution of16 bit or more and should be equal or less than 139 microns for good image quality.the partial resolution should be 3lp/mm.the detector should come with 2 batteries and atleast 1 wired or wireless charger .the Pixel matrix should be 3072 x 2476.The Wireless Panel should have an capacity to store atleast 10 images on the board..Battery should be ggod enough to work for of atleast 1500 images within 8 hrs. The software workstation should be high resolution ability to process the below features- patient scheduling and monitoring, enhancement processing feature,software should be touch screen acqisition,Dicom& HL compliant, Drage and drop images between studies,easy export imaging and annotation tools.It should be multifrequency processing. The Supplier should provide PC with monitor of atleast1TB space or more. Should supply online 3KVA UPS with batteries inbuilt.
High Flow Nasal Oxygen Machine
Fully Automated Random Access Clinical Chemistry Analyzer- Table Model- 200 Tests per hour. Throughput- 200 test/Hour photometric and 400 tests/Hour with ISE* (*optional ISE with Na,K,Cl,Li) With Distilled Water Plant With Permanant Hard Glass Cuvette This Machine & Accessories Should be Make In India Only.
Online U.P.S. -2 KVA. 30 minutes Backup for Laboratory Equipments
VARSHA ENTERPRISES
Displayor Trading Corporation
M/s Pinnacle Biomed Pvt Ltd
BioResource Biotech Pvt. Ltd.
INNOVEE
Chitrasales And Services
SHREEJI SAFETECH
Maharashtra Surgicals
kk sales corporation
Keps Pharma
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .