Repair and maintanance of PLC,SCADA,Clorination system etc. at existing 13 MLD STP Anasagar Lake Ajmer.operation and Maintanance period 03 years.
2024_DLB_435914_1
06/2024-25/0rder751/6.12.2024
Open Tender
Repair and Maintenance Works
Item Rate
60 days
Ajmer
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,500
as per mentioned in BID/NIB
₹70,000
Yes
24 Dec 2024
8 Dec 2024
16 Dec 2024
8 Dec 2024
14 Dec 2024
8 Dec 2024
8 Dec 2024 - 14 Dec 2024
Amount
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following:AO 1No.,MCB 6ADP-6Nos.,SMPS 100-240VAC/ 4.5A / 24 VDC-01 No.,Control Relays-01 No.,Emergency STOP Push Button-01,Panel Cooling Fan & Filter-02,Panel Light with Door Switch, 7W-01,Control Indication Lamp for 24VDC, 220VAC-03,Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc- Lot 01,Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc-- Lot 01
Providing, Installation, Testing and Commissioning of Ultrasonic Open Channel Flow Meter (Upto 5 metre Head rise): Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1%
Operator Station including, Core i5 processor, 8 GB RAM, 1TB SSD, DVD RW Drive, RS232/485/RJ45 Port, 1 Parallel Port, 4 nos. USB Port, 2x Ethernet Cards, Keyboard, Optical mouse, 32'' LED monitor, Latest windows professional, Anti Virous, etc.
Black and white, A4 Size Laser Printer , copier, Scan. Hi-Speed USB 2.0 port; built-in Fast Ethernet 10/100Base-TX network port; built-in WIFI 802.11b/g/n
Online UPS 3 KVA with 60 min Backup time.
Providing, installation, testing and commissioning of vacuum Feed Gas Chlorinator system with all accessories and making connection with existing pipeline required including supply & installation of ejector unit, Vacuum chlorination unit, trunnion roller support, auxiliary container valve, flexible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM 'Y' type strainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity including safety equipment complete in all respectas per specification and the direction of the Engineer.2 kg/hr capacity ( Repair)
Providing, Installation, Testing and Commissioning of Ultrasonic Level Transmitter : Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1%.0 - 8 Mtr.
Dissolved Oxygen Analyser : Measuring range: 0 to 20mg/l, Optical fluorescence technology , Membrane free operation Accuracy:0.01mg/l or +/-1% of measured value ; With digital transmitter having output: 4-20mA HART, IP66/67 Protection
Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.95.0 Sq. mm
Providing and laying XLPE/PVC insulated & PVC sheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25Cm thick under layer of sand and Iind class bricks covering
2.5sq mm. Armored 4 core
Operation& maintanance of PLC SCADA complete with automation mode.with all defective liablity ,connectivity to existing network and connectivity with OCEMS,RPCB data's and reporting daily to concerning Engineer incharge for 03 year from completion of repair and reddy to run/working position. The insepection finally issued by OIC of plant.
Tatvamasi Automation Pvt Ltd (BID ID -3012668)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .