GEMC-511687772677795
Awarded to ASKA EQUIPMENTS LIMITED (TRANSFERED FROM MAHARASHTRA)
₹1.1 Cr
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Portable Inflatable Emergency Lighting System | AIT - 4500 GENERAL | - | 49 NOS | ₹2.3 L | 11,038,475 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 CrQualified Make: ASKA
Model: AIT - 4500 GENERAL 482 SIR GANGA RAM HOSPITAL SQUARE SHANKAR ROAD CENTRAL DELHI DELHI 110060 | CENTRAL DELHI | DELHI | 110060 | Make: ASKA
Model: AIT - 4500 GENERAL | ₹1.1 Cr | L1 | Qualified MSE |
| 2 | L2₹1.1 Cr+₹17,640 (0.16%)Qualified Make: SQPL
Model: SQPL IELS 400 PREET VIHAR COMMERCIAL COMPLEX EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: SQPL
Model: SQPL IELS 400 | ₹1.1 Cr+₹17,640 (0.16%) | L2 | Qualified |
| 3 | L3₹1.1 Cr+₹22,050 (0.20%)Qualified Make: ORBIT
Model: ORBIT 123 MIDC HINGNA NAGPUR MAHARASHTRA 440016 | NAGPUR | MAHARASHTRA | 440016 | Make: ORBIT
Model: ORBIT | ₹1.1 Cr+₹22,050 (0.20%) | L3 | Qualified MSE |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
6 Aug 2018, 6:00 pmClosed
portable emergency lighting sysetem Portable Emergency Lighting Sysetem ( 49 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Availibality of Patent rights from Shri SANJEEV MITAL r/o
Plot no. 102
Aditya hill top residency
huda height
MLA colony road no 12
banjarahills
Hyderabad- 500034
who have purchased Patent Right in India for Inflatable Emergency Lighting System vide Patent No. 191538 Dt- 16.02.1999 shri GUIDO MEDICI of E.I.L System Itealy. Yes - License No. from Patent Holder. (Copy of License shall be furnished to buyer on demand) G 796577 - Date 08/05/2017 - Model No AIT - 4500 GENERAL - CONSTRUCTIONAL Generator Set: Recoil Starting Portable AC Generating Set Yes - 1/6 Comprising AC Generator rated of different VA 230V 1 Phase of unit Power Factor Conforming to IS: 13364 part 1/92 and petrol Run air Cooled four Stroke singal cylinder engine with resettable circuit breaker in the AC output Genetor Power Output (VA) 1200.0 - Fuel tank capacity for continuous running of Genrating set for 8 hours. Yes - A fuel level indicator should be on display panel. Yes - Outside Wind Speed at which the balloon shall remain erected. (km/hr) 45.0 - Radius up to which min. lux value of 1 shall be available after 5 minutes of Starting. (meter) 55.0 - Base Plate: - Sheet Thickness of Aluminium Base Plate. (mm) 3.0 - Ingress protection rating of the Inflated tower as per IS:10322 Part 1/82 IPX5 - No. of compressors/air blowers of suitable rating (Nos) Two - Balloon shall be cylinderical shaped made of suitable polyster based cloth to ensure emission of light with minimum loss and shall be waterproof and strengthened with flexible stiffereners to sustain inside air pressure and to remain erected against outside wind speed Yes - 2/6 Lamp Lumens. (lumen) 42000.0 - Top Cover : Made of moulded fibre glass or suitable material designed to fasten the tower balloon by suitable steel strip so that there is no air leakage at the joint. It shall provide suitable nipple/hole for filling air into the balloon and provide support for it to remain erect at wind speed of 45 km/hr. Yes - The System shall be suitable for continious running for 8 hours
without adversaly affecting the components. Yes - Overall dimensions in deflated condition nominal (mm) 600 x 450 x 500 - Control Gear shall be suitable designed and fitted with MCB
lamp ballast
ignitor
capacitors
changeover and on/off switches with indicating lamps for controlling HPMH lamp and air blowers. Yes - The Inflated tower only shall be rain proof Yes - Lamp wattage (watt) 400.0 - Base Frame shall consist of MS tube frame and a base plate of aluminium sheet of thickness to support generating set and control gear box and shall be provided with anti vibration rubber pads. M.S. Parts shall be powder coated. YES - Maximun Deflation time including repacking time (minute) 5.0 - The length of nylon 5.0 - 3/6 rope supplied for the stays. (meter) Max total weight of complete system (excluding storage box) (kgs) 50.0 - Balloon height in inflated condtion from base plate. . (meter) 4.5 - Maximum Time Taken to Inflate the balloon (sec) 60.0 - Rope dia (mm) 3.0 - No. of Rope (Nos) 3.0 - High pressure Metal Halide; lamp shall be mounted inside the balloon at the top end such that it goes up/down while inflating and deflation. Yes - System also work on 220/230V 50 Hz AC mains with provision for 3-pin socket Rating and a suitable lead wire with plugs at both ends. (Amp) Yes - CERTIFICATIONS Availability of Test Reports from Central Government or NABL or ILAC accredited Lab to prove conformity to the specification Type test Reports shall consist of Verification of all the feature and functional parameters Type tests for alternator as per IS 13364 part 1 1992 Reaffirmed 2003 excluding tests as per clause 20 4 1 b d e
m and p of IS:13364 pt 1 1992 Type tests for Engine as per clause 9 point 1 of IS 7347/1974 Reaffirmed in 2006 Inflated tower or luminaire shall be with IP X5 protection as per IS 10322 part 1 1982 Yes - Test report date 25/11/2011 - 4/6 Test report no NTH/NR/EE/2011/83-B - Name of lab NATINOAL TEST HOUSE - Address of the lab KAMLA NEHRU NAGAR
GHAZIABAD 201002 - ACCESSORIES Accessories Part of supply with the main equipments Yes - Puncture Repair Tape Size 10cm x 10 cm Yes - Lamp with requisite control gear (Nos) One No - Lamp with requisite control gear (in numbers) One number each of Lamp
Ballast and Igniter - Tool Kit Consisting of one number each of screw driver plug spanner and nut drive Yes - Puncture Repair Tape (in Nos) 03 Nos. - Number of blower (in numbers) One No. - Storage Box Suitably designed to accommodate the tower and other spare and easy to handle with proper locking arrangements (Nos) One No - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Abhishesh Rawat 110003
Safdarjung Airport 49 60
383023
GEM/2018/B/54227
GeM Contract
portable emergency lighting sysetem
GeM Contract
60 days
Delhi; New Delhi
PRODUCT
Awarded to ASKA EQUIPMENTS LIMITED (TRANSFERED FROM MAHARASHTRA)
₹1.1 Cr
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Portable Inflatable Emergency Lighting System | AIT - 4500 GENERAL | - | 49 NOS | ₹2.3 L | 11,038,475 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| portable emergency lighting sysetem Portable Emergency Lighting Sysetem ( 49 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Availibality of Patent rights from Shri SANJEEV MITAL r/o | - | - | - |
| Plot no. 102 | - | - | - |
| Aditya hill top residency | - | - | - |
| huda height | - | - | - |
| MLA colony road no 12 | - | - | - |
| banjarahills | - | - | - |
| Hyderabad- 500034 | - | - | - |
| who have purchased Patent Right in India for Inflatable Emergency Lighting System vide Patent No. 191538 Dt- 16.02.1999 shri GUIDO MEDICI of E.I.L System Itealy. Yes - License No. from Patent Holder. (Copy of License shall be furnished to buyer on demand) G 796577 - Date 08/05/2017 - Model No AIT - 4500 GENERAL - CONSTRUCTIONAL Generator Set: Recoil Starting Portable AC Generating Set Yes - 1/6 Comprising AC Generator rated of different VA 230V 1 Phase of unit Power Factor Conforming to IS: 13364 part 1/92 and petrol Run air Cooled four Stroke singal cylinder engine with resettable circuit breaker in the AC output Genetor Power Output (VA) 1200.0 - Fuel tank capacity for continuous running of Genrating set for 8 hours. Yes - A fuel level indicator should be on display panel. Yes - Outside Wind Speed at which the balloon shall remain erected. (km/hr) 45.0 - Radius up to which min. lux value of 1 shall be available after 5 minutes of Starting. (meter) 55.0 - Base Plate: - Sheet Thickness of Aluminium Base Plate. (mm) 3.0 - Ingress protection rating of the Inflated tower as per IS:10322 Part 1/82 IPX5 - No. of compressors/air blowers of suitable rating (Nos) Two - Balloon shall be cylinderical shaped made of suitable polyster based cloth to ensure emission of light with minimum loss and shall be waterproof and strengthened with flexible stiffereners to sustain inside air pressure and to remain erected against outside wind speed Yes - 2/6 Lamp Lumens. (lumen) 42000.0 - Top Cover : Made of moulded fibre glass or suitable material designed to fasten the tower balloon by suitable steel strip so that there is no air leakage at the joint. It shall provide suitable nipple/hole for filling air into the balloon and provide support for it to remain erect at wind speed of 45 km/hr. Yes - The System shall be suitable for continious running for 8 hours | - | - | - |
| without adversaly affecting the components. Yes - Overall dimensions in deflated condition nominal (mm) 600 x 450 x 500 - Control Gear shall be suitable designed and fitted with MCB | - | - | - |
| lamp ballast | - | - | - |
| ignitor | - | - | - |
| capacitors | - | - | - |
| changeover and on/off switches with indicating lamps for controlling HPMH lamp and air blowers. Yes - The Inflated tower only shall be rain proof Yes - Lamp wattage (watt) 400.0 - Base Frame shall consist of MS tube frame and a base plate of aluminium sheet of thickness to support generating set and control gear box and shall be provided with anti vibration rubber pads. M.S. Parts shall be powder coated. YES - Maximun Deflation time including repacking time (minute) 5.0 - The length of nylon 5.0 - 3/6 rope supplied for the stays. (meter) Max total weight of complete system (excluding storage box) (kgs) 50.0 - Balloon height in inflated condtion from base plate. . (meter) 4.5 - Maximum Time Taken to Inflate the balloon (sec) 60.0 - Rope dia (mm) 3.0 - No. of Rope (Nos) 3.0 - High pressure Metal Halide; lamp shall be mounted inside the balloon at the top end such that it goes up/down while inflating and deflation. Yes - System also work on 220/230V 50 Hz AC mains with provision for 3-pin socket Rating and a suitable lead wire with plugs at both ends. (Amp) Yes - CERTIFICATIONS Availability of Test Reports from Central Government or NABL or ILAC accredited Lab to prove conformity to the specification Type test Reports shall consist of Verification of all the feature and functional parameters Type tests for alternator as per IS 13364 part 1 1992 Reaffirmed 2003 excluding tests as per clause 20 4 1 b d e | - | - | - |
| m and p of IS:13364 pt 1 1992 Type tests for Engine as per clause 9 point 1 of IS 7347/1974 Reaffirmed in 2006 Inflated tower or luminaire shall be with IP X5 protection as per IS 10322 part 1 1982 Yes - Test report date 25/11/2011 - 4/6 Test report no NTH/NR/EE/2011/83-B - Name of lab NATINOAL TEST HOUSE - Address of the lab KAMLA NEHRU NAGAR | - | - | - |
| GHAZIABAD 201002 - ACCESSORIES Accessories Part of supply with the main equipments Yes - Puncture Repair Tape Size 10cm x 10 cm Yes - Lamp with requisite control gear (Nos) One No - Lamp with requisite control gear (in numbers) One number each of Lamp | - | - | - |
| Ballast and Igniter - Tool Kit Consisting of one number each of screw driver plug spanner and nut drive Yes - Puncture Repair Tape (in Nos) 03 Nos. - Number of blower (in numbers) One No. - Storage Box Suitably designed to accommodate the tower and other spare and easy to handle with proper locking arrangements (Nos) One No - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Abhishesh Rawat 110003 | - | - | - |
| Safdarjung Airport 49 60 | - | - | - |
Exempted
21 Aug 2018
25 Jul 2018
contract_GEMC-511687772677795.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_383023.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .