Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.1 CrAccepted-AOC | ₹1.1 Cr | 1 | Accepted-AOC Acceptance Of Tender |
| 2 | 2₹1.2 Cr+₹6.5 L (5.93%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | ₹1.2 Cr+₹6.5 L (5.93%) | 2 | Rejected-Finance Not L1 |
| 3 | 3₹1.2 Cr+₹10.5 L (9.59%)Rejected-Finance | ₹1.2 Cr+₹10.5 L (9.59%) | 3 | Rejected-Finance Not L1 |
| 4 | 4₹1.2 Cr+₹15.3 L (14.0%)Rejected-Finance | ₹1.2 Cr+₹15.3 L (14.0%) | 4 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | jayanti associates L3 | rajan construction L1 | M/s Sahu Associates L4 | R K CONTRACTOR AND SUPPLIERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete complete all as specified & directed. | 15 | Cum | 405 ₹6,075 | 200 ₹3,000 | 530 ₹7,950 | 100 ₹1,500 Lowest |
| 2.00 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in in CM (1:6) complete all as specified & directed. | 3 | Cum | 4,909 ₹14,727 | 4,000 ₹12,000 | 4,500 ₹13,500 | 3,000 ₹9,000 Lowest |
| 3.00 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in in CM (1:4) complete all as specified & directed. | 12 | Cum | 4,925 ₹59,100 | 4,500 ₹54,000 | 4,500 ₹54,000 | 1,600 ₹19,200 Lowest |
| 4.00 | Taking down cement plaster on brick walls / ceiling incl. raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. | 1,960 | Sqm | 18 ₹35,280 | 12 ₹23,520 | 30 ₹58,800 | 10 ₹19,600 Lowest |
| 5.00 | M&L for rendering 15mm thick in CM 1:6 brick work or concrete surface and finishing the surface even and smooth without using extra cement all as specified and directed. | 1,070 | Sqm | 164 ₹1,75,480 Lowest | 165 ₹1,76,550 | 200 ₹2,14,000 | 180 ₹1,92,600 |
| 6.00 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, mixed with liquid WPC as per manufacturer’s instructions, finished even & smooth(without using extra cement) incl mouldings, chamfers, splay srounded or coved angles, beads,grooves and rebate upto 10 cm in width or 15 cm in girth. Note : Supply only water proofing compound shall be measured and paid for separately. | 870 | Sqm | 175 ₹1,52,250 Lowest | 175 ₹1,52,250 Lowest | 220 ₹1,91,400 | 180 ₹1,56,600 |
| 7.00 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth (without using extra cement) complete, all as specified. | 220 | Sqm | 164 ₹36,080 | 120 ₹26,400 Lowest | 150 ₹33,000 | 200 ₹44,000 |
| 8.00 | M&L for preparation of new plastered surface of wall including wall care putty 2-3mm thick and applying two coats of oil emulsion distemper (OBD) over a coat of primer complete all as specified and directed. | 2,120 | Sqm | 72 ₹1,52,640 | 65 ₹1,37,800 Lowest | 110 ₹2,33,200 | 85 ₹1,80,200 |
| 9.00 | M&L for Complete removal of exiting treatment and applying two coats of oil bound distemper over one coat of wall care putty (Make : Birla/JK White) of wall incl preparation all as specified and directed. | 150 | Sqm | 82 ₹12,300 | 66 ₹9,900 Lowest | 70 ₹10,500 | 85 ₹12,750 |
| 10.00 | Repairing of RCC projections chajjas, roofs, facia etc by necessary preparation, scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC and providing cement concrete (1:1.5:3) using 12.5 mm graded crushed stone aggregate including necessary form work and reinforced with chicken wire mesh and rendering in cement mortar 1:3 using coarse sand in patches area not exceeding 5 sqm each and thickness of RCC member not exceeding 70mm including applying two coats of finishes as provided to the existing surfaces to match with the existing surfaces in at any height complete all as specified and directed. | 25 | Sqm | 1,120 ₹28,000 | 300 ₹7,500 | 225 ₹5,625 Lowest | 500 ₹12,500 |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
24 Nov 2025, 6:00 pmClosed
CWE Lucknow
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
SPL REPAIR TO BLDG NOP 51 AT DEO AND SPL REPAIR TO BLDG NO 3 BSM OFFRS MESS STAFF LIVING OF 7 KUMAON AND SPL REPAIR TO TOILET BATH ROOM OF BLDG NO P 287 AT HQ 41 INF BDE AND SPL REPAIRS OF OTHER BLDGS UNDER GE EASTLUCKNOW
2025_MES_733359_2
CWE/LKO/E/T-36 OF 2025-26
Open Tender
Civil Works
Item Rate
270 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE East lukcnow
₹2.6 L
Yes
17 Feb 2026
10 Nov 2025
26 Nov 2025
10 Nov 2025
24 Nov 2025
17 Nov 2025
10 Nov 2025 - 17 Nov 2025
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete complete all as specified & directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in in CM (1:6) complete all as specified & directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in in CM (1:4) complete all as specified & directed.
Taking down cement plaster on brick walls / ceiling incl. raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:6 brick work or concrete surface and finishing the surface even and smooth without using extra cement all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, mixed with liquid WPC as per manufacturer’s instructions, finished even & smooth(without using extra cement) incl mouldings, chamfers, splay srounded or coved angles, beads,grooves and rebate upto 10 cm in width or 15 cm in girth. Note : Supply only water proofing compound shall be measured and paid for separately.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth (without using extra cement) complete, all as specified.
M&L for preparation of new plastered surface of wall including wall care putty 2-3mm thick and applying two coats of oil emulsion distemper (OBD) over a coat of primer complete all as specified and directed.
M&L for Complete removal of exiting treatment and applying two coats of oil bound distemper over one coat of wall care putty (Make : Birla/JK White) of wall incl preparation all as specified and directed.
Repairing of RCC projections chajjas, roofs, facia etc by necessary preparation, scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC and providing cement concrete (1:1.5:3) using 12.5 mm graded crushed stone aggregate including necessary form work and reinforced with chicken wire mesh and rendering in cement mortar 1:3 using coarse sand in patches area not exceeding 5 sqm each and thickness of RCC member not exceeding 70mm including applying two coats of finishes as provided to the existing surfaces to match with the existing surfaces in at any height complete all as specified and directed.
M&L for complete removal of existing treatment by sraping with mechaanical wall sander(having mechanical vacuum mechanism) having RPM not less than 1500,sandinf pad of 80 Grit having dia of 7''/9'' to make the surface freee from dust,loose paint etc by skilled labour complete all as specified and directed.
M&L for wateproof cement based putty@ 1 kg (undiluted) per sqm of average thickness 1 mm over plastered/old painted wall after scraping to prepare the surface even and smooth complete and sanding of the putty surface with with machenical wall sander (havin machenical vacum machanism) having RPM not less than 1500 sanding pad of 240 Grit or above to make the surface free from dust etc by skilled labour as per following steps:- Step1) Mix the putty powder by adding water as per manufacturer instruction and mix it with putty mixer with mixing capacity of min 2.5kg putty per minute. Step 2) Applying the first coat the prepared mixer with the help of fully authmatic airless spray machine of putty application having flow speed of max 6ltr per minute with a maximum pressure 3300 PSI. Step 3) Aloow 6-8 hrs time to dry the putty surface.
M&L for one coat to acrylic water based exterior grade primer @0.90ltr9undiluted)/10 sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application having an electric motor of min.1 HP with a flow speed of min 1 ltr per minute having pressure of 3300 PSI,allow 6-8 hrs to dry the surface for painting of subsequent coats as per manufactures instruction complete all as specified and as directed.
M&L for two coat water based premium acrylic smooth water based exterior emulsion of approved colour with silicon additive & color stay Technology,Excellent dirt pick resistance with low VOC less than 50gram/ltr as per the LEEDS specifications,Anti allgal properties in two coats@ 1.79 ltr(undiluted)/10 sqm diluted with water as per manufacturer instruction applied with fully automatic airless spray machine of paint application a flow speed of min 1 ltr per minute having pressure of 3300 PSI,allow 6-8 hrs to dry the surface for painting of subsequent coats as per manufactures instruction complete all as specified and as directed.
M&L fo ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the premises
M&L of Vitrified (double charged) ceramic tiles designed dark/light shed, 10 mm thick(square /rectangular), polished, area of each tile exc 0.42 sqm but n.exc. 1.00 Sqm in floor etc , laid over 20 mm thick screed bed 1:6 ,set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified.
Ditto as above but on vertical surfaces dado/ skirting over 10mm thick plaster in CM 1:4 and incl taking down cement plaster etc complete all as specified. complete all as specified and as directed.
M&L for exterior quality wall tiles (coloured) 300x600 x 7-8mm / 100x300x7-8mm / 200x300x7-8mm thick on vertical surfaces such as dado, skirting external faces of building sych as entrance, receiption etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick rendering in cement & sand mortar 1:4, complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 sqm as in floors joints free, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified and as directed.
M&L for glazed ceramic tiles (coloured) 300x600 x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick rendering in cement & sand mortar 1:4, complete all as specified and as directed.
S&F of hallow strip PVC Wall Linning on wall consisting of 5mm thick any color/desigened PVC sheet inclusive of nails and fixing at site all and PVC L-beading at top of wall lining,corner of wall,opening eadge of door & windows matching with panel as per specifications and drawing complete all as specified and as directed.
S&F of hallow radial strip PVC Linning on ceiling consisting of 5mm thick any color/desigened PVC sheet in ceiling inclusive of nails and fixing at site and PVC L-beading at top of lining,corner of ceiling, matching with panel as per specifications and drawing with GI frame work including all necessary drilling , cutting to fix electrical items as under:- (a) GI sheet channel 30x25x20mm of 24 Gauge fixed with rawl plug and screws 450mm centre to center alongwith perimeter of walls. (b) GI sheet channel made to shape 50x40x40mm of 24 gauge placed @ 600mm centre to centre from perimeter of wall except long wall (in one span) (c) GI sheet intermediate runners of size 45x10x10mm of 24 gauge fixed @ 1200mm centre to centre leaving frame of one side wall (in other span) (d) GI sheet 25mm wide & 20mm gauge suspenders fixed with steel fasteners to roof, ceiling @ 1200mm centre to centre incl plugging in RCC slab.
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including iron mongery and cutting holes for hold fasts & making good complete all as specified & directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area not exc 1.5 sqm each, complete, all as specified & directed.
S&F for framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other coverings, doors etc should be prepared for hanging or sliding with and including either hooks or hinges or steel hanging door fitting (exclusive of steel hanging door fittings and other coverings, running rails and guides and hanging also fastening and fixing complete quality conforming to FE-410W(gde E-250) quality B complete all as specified & directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified and as directed.
S&F of Powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F powder coated (min 50 micron) alumium three track sliding window with extructed profile of top bottom &side track for fixing 5.50mm thick tint glass fitted with glazing clip and EPDM rubber in two shutters and fixed SS wire mesh in one shutter and powder coated deco grill incl roller and handle complete all as specified and as directed. Note:-(a) Quoted rate incl 5.5mm thick tint glass,SS wire mesh,Deco Grill etc in this item. (b) Framed section 3 Track size= 92 x 31.75 x 1.5mm (c)Shutter section size= 40 x 18 x 1.55mm
S&F powder coated alumium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified
M&L for 12 mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination ,fixed with screws to timber frame work, complete all as specified & directed.
S&F of sheet glass 4.80mm thick,ordinary quality and glazing with aluminium snap beading in squares n.exc 0.5 sq. m in each pane complete all as specified & directed.
S&F in repair brass mortice lock, vertical type, size 100mm, 4 Levers with escutcheon plates & two keys fixed in aluminium frame complete all as specified & directed.
S&F 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified & directed.
S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm complete all as specified & directed.
S&F aluminium body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg. and fixed. complete all as specified & directed.
M & L PCC 1:5:10 type E-2 as in sub base of floor mass filling (using 40 mm graded aggregate) or filling in sunken floor portion in WC/Bath with usingwater proofing compound etc complete all as directed.
M&L rendering 15 mm thick wall plaster in CM 1:3 mixed with liquid WPC finished even and smooth (w/o using exra cement) etc complete all as specified and directed. Note :- The cost of WPC is not included in this item The same shall be paid separetely as supply only
M&L applying evenly a tack coat of industrial itumen 85/25 at the rate of 1.20 kg per sqm including cleaning surfaces as in sunken complete all as specified and directed by Engr -in-charge.
S&F APP based polymeric membrane mimimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric land on primed surfaced by forced application complete all as specified.
M&L 40mm thickness PCC 1:2:4 type B-0( using 12.5 mm graded aggregate ) with liquid WPC as sub-base in sunken floor etc (WPC shall be measured and paid separately)
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills,sunshades, shelves, lintels, etc.and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good,cutting exceeding 20cm girth in brick walls complete all as directed..
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors and incl taking down of old GI tubes etc complete all as directed.. .
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors and incl taking down of old GI tubes etc complete all as directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, complete all as specified & as directed.
S&F vitreous china wash down water closet pan (Pedestal pattern EWC), coloured, floor mounted coupled closet, including connection to drain (or outgoing pipe), anti-sypohonage pipe etc, with & including WC seat cover coloured closed pattern with flat bottom and cover including vitreous china symphonic action type twin flush flushing cistern of 10 litre capacity with lid, necessary fittings complete all as specified & as directed.
S&F in repairs vitreous china half stall type urinal flat back, size of 465 x 355 x 265mm (minimum) white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified & directed.
S & F in repair PVC low level flushing cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handleetc complete all as specified & directed
S&F in repair viterious china coloured WHB 600 x 480 counter top oval shape cascade pattern including CP bottle trap including cp waste coupling 32mm dia in lead to waste pipe complete all as specified and as directed.
S & F in repair stainless steel Kitchen plate rack of overall minimum size 750 mm x 900 mm and 250 mm deep, with partitions for small/large plates etc made out of stainless steel 0.80 mm thick fixed with rawl plug and CP steel screws complete, all as directed.
S&F in repair PVC connection pipes 450/600 mm long suitable for 15 mm bore GI pipe including CP brass nuts on both sides, complete, all as specified.
S&F 15 in repairs mm dia fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, scresed down screwed for iron pipe or for brass ferrule and fixed both ends for iron pipe or for unions complete all as specified & directed.
S&F in repair 15 mm dia chromium plated fancy type angle valve pipe with capstan head long screwed shank including cp cover plate etc all as specified and directed.
S&F in repair 15 mm dia Pillar tap cast copper alloy chromium plated fancy type with capstan head and cup screwed down screwed for G I pipe or for brass ferrule all as specified.
S&F in repair 15 mm bore CP brass single lever Basin mixture w/o popup waste with 450 long braided houses fixed to GI pip etc .complete all as sp and directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed.
S&F in repair CP shop dish fancy type fixed with SS screw on wall etc all as specified and directed.
S&F in repair toilet paper holder with flat recessed type stainless steel Complete all as specified and directed
S&F in repair glass corner self assembly, fancy type, made of 6 to 7mm thick sheet toughened glass of size 250x250mm, fixed with CP brackets etc complete all as specified and directed.
Supply & fix in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long etc complete all as specified and directed.
S&F in repair CP brass tubular towel rail, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified.
S&F in repair 40mm bore PVC low density (LDPE) pipe of pressure 6kg/Cm2 fixed to wall or laid in floor, complete, all as specified.
S & F in repairs for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamp or laid in trenches or in floors etc complete all as directed.
S & F in repairs for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamp or laid in trenches etc complete all as directed.
S&F in repairs 110mm PVC (SWR) junction single (single T) equal or unequal
S & F in repairs 110mm bore PVC (SWR) bends of any radius diminshing pieces or tappers (larger bore measured) etc complete all as directed.
S & F in repairs 75mm bore PVC (SWR) bends of any radius diminshing pieces or tappers (larger bore measured) etc complete all as directed.
S & F in repairs 110mmbore PVC (SWR) branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engr-in-charge
S & F in repairs 110mmbore PVC (SWR) reducers, joint to line etc complete all as specified and directed by Engr-in-charge
S & F in repairs PVC(SWR) 'P' trap 110mm, setting and jointing with solvent cement
S & F in repairs 110mm bore PVC(SWR) WC connectors with lip ring 110mm, setting and jointing with solvent cement etc complete all as directed.
S & F in repairs 110mm bore PVC(SWR) floor trap, plain with grating including jointing with solvent cement, setting and jointing with solvent cement etc complete all as directed.
S & F in repairs 75mm bore PVC(SWR) floor trap, plain with grating including jointing with solvent cement, setting and jointing with solvent cement etc complete all as directed.
S & F in repairs PVC(SWR) gully trap 125/110mm, setting and jointing with solvent cement etc complete all as directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified & directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified & directed.
M&L for Ist class superior quality Exterior floor tiles of size 400x400x10 to12 mm thick of approved colour and shade laid over 20mm thick screed bed in C:M 1:6 complete all as specified and as directed.
Ditto all as above item No 79 but in vertical surface with in CM 1:3
M & L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specifed and as directed .
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any motar etc all as specified and directed.
M&L for Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking plateform,window sills and other similar situation complete all as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.complete all as directed.
S&F 12 mm thick toughned glass as in hinged doors, partitions automatic doors,stair railling and similar work including cutting to shape, drilling holes required and fixed with ss clamp with stainless railling etc complete all as directed.
Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge / GE including taking down existing plaster,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same to the places where directed by Engr-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.brushing neat cement slurry with 3 Kg of cement per sqm all as specified & as directed.
M&L plain cement concrete 1:2:4 type B1 using 12.5 mm graded aggregate as in roof for maint. the uniform slope etc any thickness at any height and in any position all as specified and directed by engr-in-charge at site.
M & L 15-20 mm thick rendering in cement mortar 1:4 on concrete surfaces on other than fair face surface for roof treatment, surface finished even and smooth without using extra cement using waterproofing compound fair and complete all as specified.
Supply only Liquid water proofing compound complete all as spesified and directed.
M&L for roof treatment with polymeric water proofing membrane consisting of following complete all as specified and directed :- (a) Applying hot blown bitumine 85/25 as primer conforming to IS 702-1988 @ 1.20 Kgs/ sqm. (b) APP modified bitumenous membrane minium weight 3 kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric ( wt. not less than 150 gms/sqm) laid on primed surface by heat process, over laps of 100 mm shall be sealed / fused by flame torch application as per manufacturer instructions. (c) Applying two coat of bituminous bases aluminium paint @ 0.2 kgs/sqm over APP membrane.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having colour stay technology and VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
M&L Prepration new plastered surfaces and applying two coat of white wash on ceiling all as specified.
M&L for cement concrete 1:3:6 type C2, 75 mm thick as in plinth protection and flooring and finishing the surface even and smooth without using extra cement.
Demolition of reinforced cement concrete as in self etc (reinforcement cut as reqiured to faciliate demolition) complete all as specified and directed.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks triple layered in white colour (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc incl dismantling complete, all as specified and directed.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks triple layered in white colour (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc incl dismantling complete, all as specified and directed.
S&F in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight -210 gms.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 75x50 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
S&F 65x125 mm double rebated factory made 100% solid WPC prelem both side (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed.
S&F Factory made 30 mm thick 100% solid WPC (Wood Polymer Composite) solid both side 14 micron Flush door shutter wit 10mm deep CNC moulding design of required size comprising of virgin PVC resin of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 650 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F 30mm thick factory made solid WPC (Wood plastic composit) moulded glzed door shuter with wire mesh in 08 number of division with brown wood grain texture including SS wire mesh (G-304) 0.36 mm minimum dia of wire and average width of aperature 1.4mm with XPM Aluminium alloy wire cloth of wire shall to be fixed with 15x15 square tube in side rails with screwing 8x28 heat metel zink coated screws can be remove of fix again after changing of wire mesh needed. The density not less then 650kg /Cum shall be as per manufacture instruction complete all as specified and as directed
S&F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
Supply & fixing Factory made uPVC prelame colour three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 112 x 52mm & sash 42x 68 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi- chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F 250 mm long stainless steel sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts all as specified
S&F for stainless steel barrel tower bolts 200 mm of extruded section and fixed.
S&F for stainless steel barrel tower bolts 150 mm of extruded section and fixed.
S&F 125 mm size stainless steel handles fabricated type extruded section ,ISI marked all as specified
S&F 150 mm size stainless steel handles fabricated type extruded section ,ISI marked all as specified
S&F Butt hinges 125 mm stainless steel hinges medium weight and fixed
S&F Butt hinges 100 mm stainless steel hinges medium weight and fixed
S&F in repairs 15mm dia CP two way tap consisting angle valve to control water suitable for jet cleaner all as specified.
S&F in repair Vitreous china wash hand basin white angle back size 550x400 mm including 32 mm dia CP waste coupling long screwed shank fly nut flanged end and embedded in lead to waste pipe excluding piller taps complete fixed specified and directed by enginner -in-charge.
S&F in repairs 32 mm dia Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 45gms/40mm-60 gms)
S&F in repairs 32mm dia PVC waste pipe approx 900mm long for sink/WHB complete all as specified.
M&L for gunniting to RCC works in column beams, slabs, chajja, facia, landing, balconies etc by removing/ dismantling of RCC (loose concrete) and cutting of steel bar including plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing welded steel wire mesh 75mm x75mm with 4mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm and applying 25mm thick gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) using ordinary port land cement of 43 grade over wherever required, complete all as specified and directed by Engineer-in-Charge. Note:-(i)After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with. (ii)Additional reinforced TMT bars where incorporated in work and including 20mm thick cement plaster in 1:4 (iii) Work to be carried out as in patches as directed by Engr-in-charge. (iv) Rate for steel scaffolding as directed to be included in quoted rate. (v) All demolished material removed from MOD land completely. NOTE: Work Executed by OEM under the Provision of MOU
Demolition of sunken floor treatment of WC and Bath including WC trap etc incl taking down loose filling of aggregate in any type and removing where direted and providing water proofing treatment of sunken slab as follows:- (a) 15mm thick rendering on vertical sides of RCC slab in CM 1:3 mixed with chemical " PIDIPROFF LW of Dr Pidilite or equivalent " as per manufacturer instructions. (b) Cleaning the concrete surface by brushing and watering and remove all surface inperfections. (c) Fixing 40mm dia GI Pipe 650mm long at bottom of the sunken floor and wraping of bath seal tape on the pipes inserted through walls to floor area and seal it (Bath seal tape product of Dr fixit or equivalent and grouting around the inserted pipes by pouring Dr fixit bath seal or equivalent grout as directed (d) Make angle fillets by mixing sand cement and Dr fixit pidicrete URP or equivalenont all corners. (e) Brushing neat cement slurry two coats with high performance cementitious polymer water proofing coating of Dr fixit bath seal WPC or equivalent of thickness 1mm in combination of WPC and cement (1:1.5) by vol and giving upto height 15cm from top of floor level slab and allow it dry completely. (f) Fill the sanitary gaps with sealing compounds complete
S&F 18 mm thick solid WPC board of density 600kg/Sqm one side prelaminated decoratiove teak face and other side white and balancing as in kitchen shelf, shutters etc including chawkats and all fitting accessories etc including dismantling, complete all as specified and directed
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanized width of flaps 30mm (when open) fixed with CP steel screws.
S&F in repairs stainless steel drapery curtain rods standard quality dia not less than 25mm with fancy type stainless steel latoo at both ends and Stainless Steel Bracket for middle support as required all as specified and direced as approved by GE.
M&L for application of high perfomance hybride polyurea elastomeric water proofing coating cold applied, liquid membrane at 1.5 kg/Sqm with an elongation minimum of 400 to 600% by airless spray machine and tensile strength of minimum 11-13 N/mm2 as per ASTM D2370, crack bridging ability minimum of 3 to 4 mm as per ASTM C1305 , Shore Hardness of minimum 70+5 as per ASTM D2240 complete as per directed by Engr-In-Charge. The System shall also include final base preparation including cleaning of the plaster surface etc and applying epoxy primer as approved makes in two coats at a coverage of 2 kg/Sqm, etc as per manufacturer specification, complete all as specified and directed. Note:- (a) The work pertaining to water proofing treatment shall be executed for authorized applicator through manufacture of wich the materials is proposed to be used by the contractor and approved by Garrision Engingeer.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 usin g 20 mm graded stone aggregate as in coping and benching of roof etc. complete all as specified and directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, all as specified and as approved by GE/Engineer-in-Charge.
S & F gun metal gate valve screwed both ends to15mm bore pipe complete all as specified.
M&L for Plastering by using readymix mixture of thickness 12 mm to 15 mm thick in CM 1:4 and taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge.
M&L for Plastering by using ready mix mixture of thickness 12 mm to 15 mm thick in CM 1:4 with water proofing liquid and taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge.
M&L for Plastering by using ready mix mixture of thickness 5 mm to 7 mm on ceiling including taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge.
Dismantling of Bricks (laid flat or on edge) or brick tiles in floors or roof laid beded and pointed in any mortar
S&F for XPM Aluminium alloy wire cloth of wire all as specified and directed.
S & F of vajra series windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy-duty stain less steel pivot hinges shall be provided per shutter. The windows should be panelled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self-expanding, screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes.
S&F in repairs vitreous china squatting pan "Orissa" pattern size 580mmx440mm white with integral foot rests including connection to trap, and to flushing pipe, anti syphonage pipe, etc complete making good to floors and complete all as specified and as directed.
S&F in repair brass chromium plated shower rose 125 mm size without swivel joint including fixing to steel pipe of 15mm bore or union complete all as specified.
Surface excavation not exc 30 cm deep averaging 15 cm deep and getting out in soft/ loose soil.
M&L hard core of gauge n exc 63mm, deposited spred and levelled (broken red brick) in layers n exc 15 cm thick ,warered and rammed to a true surface.
M&L 100mm thick PCC type D-2 1:4:8 (40mm graded stone aggregate) for sub base.
S&F powder coated aluminium window and ventilator shutters, fixed type with sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F 4.00 mm thick sheet glass ordinary quality and glazing with Aluminium beads in square exc 0.5 sqm in each pane complete all as specified
S&F 4.00 mm thick sheet frosted glass and glazing with oil putty/Aluminium beads in square exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces ground or obsecured to one side complete all as specified.
Powder coated aluminium Grill (anodised tranparent of dyed to required shade according to IS1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the exiting window frame with CP brass/ stainless steel screws @200 mm centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Enginer-in-charge.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apeerture 1.40 mm and fixed with tinned tacks, or galvanised wire staples, all as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efforescent salts, trading oil, greasy sopts etc and preparation of plastered surfaces and applying two coat of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, over a coat of 2mm thick putty of required shade and colour complete, as per manufacturer's specification over Complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint of approved shade/tint by using roller only complete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S&F mild steel section such as Roof trusses (framed), trussed,purlins, crane antries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to IS 1161-1979 Fe-450(Gde E-250)complete all as specified and as directed.
M&L for preparation of old surfaces of steel of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
Taking down carefully copper/aluminium point wiring ( light, fan, socket , bell or power) complete including all electrical fittings & fixtures complete.
Material and Labour for point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed multi stranded copper conductor single core cable 1100 volts grade in and including PVC conduit with accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed. Note :- Sunken box/cover plate for modular switches, sockets etc will be measured and paid seperately under relevant items and blank plate required if any will be deemed included in the item rate.and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall all as specified.
All as per Item No 152 hereinbefore but for One 5 A socket outlet on independent Board all as specified and directed.
All as per Item No 152 hereinbefore but for One 5 A socket outlet on same Board all as specified and directed.
All as per Item No 152 hereinbefore but point wiring complete with 2.5 sqmm for 3 pin 15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed.
S&F white cover plate with frame 3 module.
S&F white cover plate with frame 6 module.
S&F white cover plate with frame 8 module.
S&F white cover plate with frame 12 module.
S&F modular metal boxes 1.0 mm thick 3 module including wall cutting for conealing and making good disturbed surface as required.
S&F modular metal boxes 1.0 mm thick 6/8 module including wall cutting for conealing and making good disturbed surface as required.
S&F modular metal boxes 1.0 mm thick 12 module including wall cutting for conealing and making good disturbed surface as required.
S&F Modular switch single pole, one way 6A, 230V, AC, one module.
S&F Modular switch single pole, one way 16A, 230V, AC, one module.
S&F Modular socket 2/3 pin combined 6A, 230V AC, two module.
S&F Modular socket 6A/16A 2/3 pin combined 230V, AC, two module.
S&F modular bell push single pole 1 module, 6A, 230V.
S&F call bell, ding dong / musical AC single phase 230 volts.
S&F ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three terminals polycarbonate insulated body complete.
Supply and fix brass coating fancy wall spot/Display/picture light with adjustable head and colour changing fucntion 12W complete.
S&F in repairs LED surface mounted Batten 20-22 watt, powder coated die cast / extruded aluminium Body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen efficacy 120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
S&F in repairs decorative fancy type LED lighting fixture Single brass made bracket with 140mmX78mm rectangular base,210mm length U Shaped brass arm 60 mm dia gallery with 2 pin brass holder tipped with 125mm length MS Powder coated down pipe ,mounted on MS powder coated plate, frosted glass shade 155mmX129MM FINISH DULL BLACK POWDER COATEDand lacquer coated suitable for 03 to 5 watt LED bulb with required electrical connection all as specified .
S&F LED surface mounted mirror light 10 watt, powder coated die cast / extruded aluminium Body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED & electrical circuitary), of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen efficacy 120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
S&F in repairs surface mounting LED light fitting of 15 watt white powder coated CRCA housing with LEDs.,efficacy 100 lumen/watt,CRI>80 and pf>0.9,surge protection 2.5 KV, Seamless front frame with flat white high transmission acrylic cover all as specified .
S &F in repairs LED bulk head fitting 9 watt IP 66 & IK 09 polycorbobate body prewired connection with 0.75 PVC Sqmm PVC insulated & Sheathed three core flexible multi standard copper conductor cable
S&F Engagement light with set of three light (Red, Yellow, and Green light), lamp holder of insulated body with back plate including connection with with 1.0 sqmm 3 core cable as required.
S&F recess mounting 36 watt panel light 2 ft x 2 ft powder coated die cast / extruded aluminium body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver as per the requirement having efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5%), life time (LED & electrical circuitry), of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K / 6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 years OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output, LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
S&F recessed mounted 2 to 3 watt round LED ceiling light SMD type with diffuser spring loaded having lumen output not less than 120 lumen/watt suitable for fixing in 3" junction boxes including connection complete.
S&F recessed mounted 6 watt round LED ceiling light SMD type with diffuser spring loaded having lumen output not less than 120 lumen/watt suitable for fixing in 3" junction boxes including connection complete.
S&F recessed mounted 12 watt round LED ceiling light SMD type with diffuser spring loaded having lumen output not less than 120 lumen/watt suitable for fixing in 3" junction boxes including connection complete.
S&F in repairs 45W Pressure die cast aluminium housing street light with system lumen of 6300 lm and system efficacy of 140 lm/w, IP-66,IK-10 single piece die cast incl spigot, dia 48-76mm,LED lifetime (L70B50) 75k Hrs with integrated optical cover. Street light should have standalone lighting control system with AUTO ON/OFF based on DUSK/DAWN timings,preset time settings with monthly variations (Jan to Dec), inbuilt real time clock for switching, incleds dimming profile for energy savings,drift not exceedind max 2mins/year, clock retention upto five yeras, auto switching off secondary power for module,dimmable driver based on PWM control, dim to off with high/low voltage cut off with 440V protection for 8 hrs for complete luminiarie incl driver and astro module,surge protection as perIEC 61000-4-5 incl MS Clamps and bracket of 40mm dia and farsnut for fixing the light all as specified
S&F in repairs MCB DB TPN 4 way 415 volts, double door type IP-43,IK-09 with minimum capacity of 100 Amps rated bus bar including necessary dummy plate and necessary civil works all as required
S&F in repairs MCB DB TPN 8 way 415 volts, double door type IP-43,IK-09 with minimum capacity of 100 Amps rated bus bar including necessary dummy plate and necessary civil works all as required
S&F in repairs MCB distribution board triple pole and neutral (VTPN),double door, IP-43 & IK-09 AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete Incoming - MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Outgoing - MCB, SP, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 12 Nos.
S&F in repairs MCB, SP, AC, 240V 10 KA, 6 to 32 Amp 'C' series, ISI marked including making connections by using suitable copper lugs as required.
S&F in repairs MCB DB SPN 8 way 230 volts, double door type IP-43 & IK-09 with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as required
S&F in repairs MCBs SPN 40 to 63 amp 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs as required.
S&F in repairs TPN three pole 415 volts 40 to 63 Amps repturing capacity 10KA SI marked including making connections by using suitable copper lugs as required.
M & L for renewal of submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable using colour coding drawing into and including concealed rigid non metallic PVC conduit 20 mm dia, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x4 sqmm + 1x4 sqmm earth wire complete.
M & L for renewal of submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable using colour coding drawing into and including concealed rigid non metallic PVC conduit 25 mm dia, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x6 sqmm + 1x6 sqmm earth wire complete.
S&F in repairs 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16 amp as required.
S&F in repairs storage water heater (Geyser) of capacity 25 ltrs, 230 volts, power consumtion 2KW, vertical type, Rated pressure 0.8MPA for high rise buildings,rust and shock proof ABS Outer body for lomg life,Stainless steel inner tank of 304 grade,65 MPa bar pressure,automatic shut off including four nos of rag bolts and making the elctrical / water supply connection including testing after installation complete.
S&F in repairs ceiling fan 1200 mm sweep, BEE star rated 5 with brush less direct current (BLDC) motor, class of insulation: B, 3 Nos blades, up to 90 cm long down rod, canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value(CM/M/W) minimum 6.00, air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz including taking down old fan and depositing in MES store yard complete.
S&F in repairs Solar integral AIO streetlight with Aluminium housing, reliable & robust construction with IP65 & IK08 protection. The luminare Lithium /LifePo4 Battery capacity min [email protected] or 20w4.5v pv panel power CRI >=70, System Efficacy >165lm/W, & Minimum Lumen 4000 system wattage should not be more than 25W ± 2%, if wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. Weight not more than 2.32 kg . The fixture should have in microwave motion sensor &sensor dealy time 18 seconds Life class of LED 50000hrs@ .complete
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core including taking out ol unserviceable cable all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified
Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point complete all as specified
Supply and laying or fixing of DWC HDPE alongwith all accessories like socket,bend,couplers etc ISI marked as per IS-16205 (Part-24) incl cutting jointing laid in trenches,wall, floor etc as required 63mm dia and 50mm inner dia ( for cable protection) complete.
Supply and fixing in repairs PVC fresh Air fan 250mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with suitable size of copper conductor cable all as specified.
M&L for earthing with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 4 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DBs including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete.
S&F wall mounted fan with powder coated gaurds and blades of approved colour, AC single phase, 230 volts, 50 Hz, 1440 RPM, 400 mm sweep with adjustable vertical angles and three speeds controls mounted within easy reach of hands with necessary connecting cable recommended / provided by manufacturer complete
S&F PVC trunking 54x105 mm size with accessories such as elbow, bend tee, socket, junctions and flexible covers for cable tray riser to DB and DB to sub DB for sub main wiring and making good to disturbed wall surfaces as required.
S&F decorative wall mounted fancy light fitting made up of brass rubi lamp brand double handed item including of thred type bulb of 9-15 watts covered by glass complete all as specified.
S & f in repairs laying 6 sqmm two core aluminium cable incl 25mm dia PVC Conduit and all other connected items complete.
Supply and fixing storage water heater (Geyser) of capacity 50 ltrs, 230 volts, power consumtion 2 KW vertical type, Rated pressure 0.8MPA suitable for high rise buildings,rust and shock proof ABS Outer body for lomg life,Stainless steel inner tank of 304 grade,65 MPa bar pressure,automatic shut off including four nos of rag bolts and making the elctrical / water supply connection including testing after installation complete.
Supply and fixing steel body Ex-fan 300 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with suitable size copper conductor cable all as specified.
Supply and fixing steel body Ex-fan 450 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with suitable size copper conductor cable all as specified.
R K CONTRACTOR AND SUPPLIERS (BID ID -3481594)
jayanti associates (BID ID -3479119)
M/s Sahu Associates (BID ID -3481498)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_827585.xls
BOQ • 0.50 MB
TenderT362ndcall.pdf
Tender Documents • 1.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .