| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-Finance | ₹7.6 L | L1 | Accepted-Finance Less Rate quoted by bidder compared to estimated amount. |
| 2 | L2₹7.6 L+₹2,192.75 (0.29%)Rejected-Finance NO 3 1ST FLOOR PLOT NO 9 LAKSHMIPURAM EXTN 2ND STREET WEST TAMBARAM | CHENNAI | CHENGALPATTU | TAMIL NADU | 600045 | ₹7.6 L+₹2,192.75 (0.29%) | L2 | Rejected-Finance Above Rate quoted by bidder compared to estimated amount. |
| Sl No | Description | Qty | Unit | Vibrant Foundation L2 | BLUE MOON ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling Brick / Stone in Clay walls under 3m high | 10.5 | M3 | 81 ₹850.5 | 80.5 ₹845.25 Lowest |
| 2.00 | Precast Concrete Block masonry using Hollow Concrete Blocks of size 400x200x200 mm of grade B (5.0) conforming to IS 2185 (Part 1) : 2005 with following cement mortar for partition wall in accordance with IS 2572:2005 including mortar plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. | 14.5 | M3 | 5,905 ₹85,622.5 | 5,902 ₹85,579 Lowest |
| 3.00 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. | 122 | M2 | 313 ₹38,186 | 312.1 ₹38,076.2 Lowest |
| 4.00 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification for Roof | 931 | Kg | 115 ₹1,07,065 | 114.3 ₹1,06,413.3 Lowest |
| 5.00 | Roofing with Galvanised corrugated iron sheet of thickness 0.8mm | 121 | M2 | 1,080 ₹1,30,680 | 1,079 ₹1,30,559 Lowest |
| 6.00 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. | 225 | Kg | 110 ₹24,750 | 108 ₹24,300 Lowest |
| 7.00 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer | 11.5 | M2 | 7,485 ₹86,077.5 | 7,480 ₹86,020 Lowest |
| 8.00 | Paving the floor with best quality vitrified Tiles ( Double charged Matt & Glossy finish 600x1200x8.5mm size) of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) | 106 | M2 | 1,375 ₹1,45,750 | 1,374 ₹1,45,644 Lowest |
| 9.00 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the departmental officers. | 106 | M2 | 265 ₹28,090 | 260 ₹27,560 Lowest |
| 10.00 | EXHAUST FANS - 600 mm (24")Sweep (heavy duty ) AC exhaust fan complete with necessary wall opening and making good of the wall. | 2 | Nos | 10,920 ₹21,840 | 10,915 ₹21,830 Lowest |
Tender Value
₹9.1 L
EMD Value
₹9,100
Closing Date
20 Feb 2026, 3:00 pmClosed
Directorate of Municipal Corporation
MRC Nagar, Chennai - 600028
Construction of New Canteen Kitchen shed for canteen on the first floor of the pump room at UAB Campus
2026_MAWS_655293_1
DMA/248/2025-SS4-part(2)
Open Tender
Civil Works
Item Rate
DMA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹9,100
5 Mar 2026
11 Feb 2026
20 Feb 2026
11 Feb 2026
20 Feb 2026
11 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling Brick / Stone in Clay walls under 3m high | 10.5 | M3 | - | - |
| 2 | Precast Concrete Block masonry using Hollow Concrete Blocks of size 400x200x200 mm of grade B (5.0) conforming to IS 2185 (Part 1) : 2005 with following cement mortar for partition wall in accordance with IS 2572:2005 including mortar plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. | 14.5 | M3 | - | - |
| 3 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. | 122 | M2 | - | - |
| 4 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification for Roof | 931 | Kg | - | - |
| 5 | Roofing with Galvanised corrugated iron sheet of thickness 0.8mm | 121 | M2 | - | - |
| 6 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. | 225 | Kg | - | - |
| 7 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer | 11.5 | M2 | - | - |
| 8 | Paving the floor with best quality vitrified Tiles ( Double charged Matt & Glossy finish 600x1200x8.5mm size) of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) | 106 | M2 | - | - |
| 9 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the departmental officers. | 106 | M2 | - | - |
| 10 | EXHAUST FANS - 600 mm (24")Sweep (heavy duty ) AC exhaust fan complete with necessary wall opening and making good of the wall. | 2 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_785699.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .