| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹24.4 L+₹2.1 L (9.46%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹25.3 L+₹3.0 L (13.7%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹27.3 L+₹5.1 L (22.8%)Rejected-AOC 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹28.5 L+₹6.2 L (27.9%)Rejected-AOC 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Apr 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI 400088
REP/MAINT OF LT UG CABLE ALIED WK,CAPACITOR PANEL LT PANEL ALIED WK REP/REPMT DEFVE U/S LUMINRES SENSORBASE ENERGY SAVED LED BASE LIGHT FITGS FIXTS REPMT OF SECU LIGHT SENSORBASE LED LIGHT (NSD SEWRI SRU(W) DSRV NOFRA THANE NAD(T) CABS NTS MAHUL)MKD
2024_MES_648922_1
8346/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹90,000
5 Sept 2024
2 Apr 2024
2 May 2024
2 Apr 2024
30 Apr 2024
13 Apr 2024
Amount
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core in trenches, along the wall including necessary connection and providing cable lugs as required including disconnection/taking down of existing unsvcable all as specified.
-Ditto- all as per item No 06 above here-in-before but 70 Sqmm 3.5 Core -do-
-Ditto- all as per item No 06 above here-in-before but 50 Sqmm 3.5 Core -do-
-Ditto- all as per item No 06 above here-in-before but 35 Sqmm 3.5 Core -do-
-Ditto- all as per item No 06 above here-in-before but 25 Sqmm 3.5 Core -do-
-Ditto- all as per item No 06 above here-in-before but 16 Sqmm 4 Core -do-
-Ditto- all as per item No 06 above here-in-before but 10 Sqmm 4 Core -do-
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge..
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/ PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints.
-Ditto- all as per item No 14 here-in-before but 3.5/4 core 70 Sqmm to 120 Sqmm size -do-
-Ditto- all as per item No 14 here-in-before but 3.5/4 core 150 Sqmm to 185 Sqmm size -do-
-Ditto- all as per item No 14 here-in-before but 3.5/4 core 185 Sqmm to 400 Sqmm size -do-
S& F in replacement of GI pipe medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
Supply and fix Power Capacitors of Rating 25 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified.
All as per item No 19 above but Power Capacitors of Rating 20 KVAR 415 Volt
All as per item No 19 above but Power Capacitors of Rating 15 KVAR 415 Volt
All as per item No 19 above but Power Capacitors of Rating 10 KVAR 415 Volt
All as per item No 19 above but Power Capacitors of Rating 7.5 KVAR 415 Volt
All as per item No 19 above but Power Capacitors of Rating 5 KVAR 415 Volt
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
Equipment and labour for servicing of ACB including drawing/taking out from LT Panel, cleaning the Contacts, checking the breaker accessories, replacing the burnt out control wiring, burnt fuse units, old unsversiable spring units for proper function and carrying out ratio test by applying primary injection all for LT ACB 630 Amps to 800 Amps and refixing the breaker in position and testing all as directed by Engineer in Chare at site Note : The Contractor shall brought all T & P and testing equipments.
Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw, display. Make : L & T / SCHNIDER/ ABB/ C&S
M & L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing Capping, fuse units and cleaning and testing complete all as specified and directed.
Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating, Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system complete all as specified and directed.
All as per item No 33 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 33 above but Contactor Three Pole 415 volts 40 Amps AC 3 RatingConforming to Type - MNX - 40. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 33 above but Contactor Three Pole 415 volts 50 Amps AC 3 Rating Conforming to Type -MNX - 50. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 33 above but Contactor Three Pole 415 volts 70 Amps AC 3 Rating Conforming to Type - MNX - 70. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 33 above but Contactor Three Pole 415 volts 110 Amps rating Conforming to Type - MNX - 110. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 33 above but Contactor Three Pole 415 volts 140 Amps AC 3 Rating Conforming to Type - MNX 140. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
S & F in repair MCCB 400 Amps, 36 KA Triple Pole 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed.
All as per item No 40 above but MCCB 250 Amps, 25 kA Triple Pole 415 Volts
All as per item No 40 above but MCCB 200 Amps, 25 kA Triple Pole 415 Volts
All as per item No 40 above but MCCB 125 Amps, 16 kA Triple Pole 415 Volts
All as per item No 40 above but MCCB 100 Amps, 16 kA Triple Pole 415 Volts
All as per item No 40 above but MCCB 63 Amps, 16 kA Four Pole 415 Volts
All as per item No 40 above but MCCB 40 Amps, 16 kA Four Pole 415 Volts
Supply and Fix in repairs Change Over FP ON Load with advanced Neutral of current rating 250 Amps 415 Volt IN Sheet Steel Enclosure of 2mm thickness in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
Supply and fix in repair add on Blocks suitable for Power contactors of range 25 Amps to 140 amps (MNX 25 to MNX 140 including making addition/Alternation to existing Wiring/circuit system all of Make- L&Tor equivalent from Schnider Electric/ABB/ C&S
Supply and Fix in repairs Push buttons complete of colour red/ green with NO/NC elements, operating on 230 V, 50Hz, AC supply complete all as specified and directed.
S & F in repairs LED based complete(R Y B ) for mounting on LT panel, operating on 230 V, 50Hz, AC supply complete all as specified and directed.
S & F in repair Closing coil 415 V/230 V for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed.
S & F in repair Shunt Release 415 V/230 for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed.
M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as specified and directed.
Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and connectors after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LED will be measured and paid separately].
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel /National/Sintax
M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using computerised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately. (ii) Cable joint will be measured and paid seperetely. (iii) Additional lenth of cable required at site for jointing will be measured and paid seperately.
M&L in repairs of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
S&F in repairs GI strip size 32 x 6 mm all as directed including welding brazing and taking down of old strips as required at site
M & L spray painting inside, outside complete to the LT panel boards outdoor type of size not exceeding 2.0 Mtr width 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface.
Supply and fix in repairs stainless steel cable glands required for cable entry in Panel of size from 10 sqmm to 50 sqmm etc. complete all as specified and directed.
-Ditto- all as per item No 62 above here-in-before but for 70 sqmm to 120 sqmm complete all as specified and directed.
-Ditto- all as per item No 62 above here-in-before but for 150 sqmm to 300 sqmm complete all as specified and directed.
Supply and fix in repairs alluminium cable lugs of size 16 sqmm to 50 sqmm for cable connection etc complete all as specified and directed.
Supply only CTC/ CRC solution spray to remove out the moisture and corrosion content from electrical equipement complete all as specified and directed.
Supply only cotton waste industrial type for cleaning of electrical equipment , Panel board etc complete all as specified and directed.
M&L in repairs for 24 Hrs 240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60Amp suitable for single phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T/Indo Asian
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 415 V, 10 - 60Amp suitable for three phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T/Indo Asian
M&L for testing of old earthing using calibrated earth tester & submitting result to Engr -in -charge all as directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
Supply & fix in repairs GI funnel suitable for GI/ Copper earthing complete all as specified and directed.
Supply only in repairs Industrial salt suitable for renewal of GI/ Copper earth plate complete all as specified and directed.
Supply only in repairs Industrial Charcoal suitable for renewal of GI/ Copper earth plate complete all as specified and directed.
M & L in repairs/ replacement of broken old us PCC earth chamber alongwith PCC cover of size 600 x 600 mm complete all as specified and directed.
S&F for Multistandarded Copper Conductor PVC insulated, 1100 volts grade cable of 3 Core 1.5 Sqmm size for interconnection of cable looping box to street Light Fitting fixed on the pole including taking down old unsv cable, complete all as specified and directed.
Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of size 20mm for Street light Poles complete all as specified and directed.
A Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repair of building Security light fitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make : Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
Supply & Fix 8/9watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, including mounting arrangement upto 2.00 mtr height with medium grade GI tubing of suitable dia 50mm alongwith MS angle bracket/framed covers, clamps complete all as specified and directed. Make - Havells or Equivalent from Bajaj/ Cromp[ton
Supply & Fix switch piano single pole flush type 5A, 240 V one way.
Supply & Fix Bell push flush type 5 amp, 230 Volts
Supply & Fix switch socket combination 2 in 1 , 5 Amps multipurpose flush type.
Supply & Fix switch socket combination 2 in 1, 3 pin, 5 and 15 Ampsflush type universal.
Supply & Fix Ceiling rose surface bakelite three terminal, 240 V.
S & F in repairs Ceiling fan regulator electronic stepped type, AC, 230 Volts, flush type.
Supply and fix bell ding dong AC 230 V single pole.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Note :- Serviceable cable cover obtained here-in-after shall be reused. Make: MEHTAB /NATIONAL TILES
Dismantling only in repairs of PCC foundation / pole coping from ground level all as per specified.
M & L in repairs for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
S & F in repairs copper 20x3 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in conuit / pipe or fixed to poles or any other indicated situation for earthing, etc. as fixed / laid in repairs complete including taking down old u/s earth strips all as specified and directed by the Engineer-in-charge
M & L in repairs for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 12 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 8mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L in repairs for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed.
Dismantling only in repairs of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.
Supply, Fixing in reparis / replacement and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make: Bajaj/ Crompton or equivalent.
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing cable gland plate and including cable glands as required at size and making connections including taking down old u/s junction boxes complete all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel
M&L for cutting existing road/hard standing not exc 30x60 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well rammaing watering finish suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top', including removal of surplase soil all as directed.
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / KEI / HAVELLS/ BENLO
Supply and fix in repairs flood light luminaire with polycarbonate optics pressure die cast housing IP 66 ingress protection, 4 KV in-built and 10 KV external SPD, having efficiency not less than or equal to 150 lm/watt, CCT 5700oK in buildings etc the fitting shall be of LED type 150 Watts including taking down old u/s fittings complete all as specified. Make : Bajaj/ Jaguar/ Wipro/ Benlo/ Havells/ Crompton
S & F in repairs of decorative 15 Watts LED (Ruby clear type, IP-65) New generation, post Top energy saving, environmental friendly, long life aesthetically disigned with symmetical light distribution, spun aluminium landscape luminaire with high power LED's as light source including mounting arrangement upto 2.00 mtr height with medium grade GI tubing of suitable dia 50mm alongwith MS angle bracket/framed covers including clamps, bolts nuts, painting by aluminium paint complete all as specified and dierected by Engr-in-Charge. The fitting shalll conform to cat No - SZPGPMX015 of Shakti/Bajaj/ Jaguar or Equivalent from Polycab/Panasonic/Havells
S & F in repair/replacement of LED Driver 60 to 70 Watts Suitable for street light fitting operating on 230 Volts, 50 Hz, AC Supply complete all as specified and directed. Make: Crompton /Havells/Bajaj
S & F in repair/replacement of LED Driver 30 to 40 Watts Suitable for street light fitting operating on 230 Volts, 50 Hz, AC Supply complete all as specified and directed. Make: Crompton /Havells/Bajaj
S & F in repair Analog Time switch astronomical type FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY). Make L&T/ C&S
Supply and fixing round shape LED Downlighter, 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Bajaj/Crompton/Jaquar
S&F Motion Sensor Switch consisting of sensitivity detector with wide detection field, integrated circuit, having automatism(day & night), convenience, safety, saving-energy and practicality functions of power indication and detection indication. Operation on receiving human motion infrared rays on entering the detection field, comprising of following features and specifications as give under :- Specification: (a) Power Source: 110 -220V/AC (b) Detection Range: 360° (c) Power Frequency: 50Hz (d) Working Temperature: -20°C~+40°C (e) Ambient Light: 3-2000LUX (adjustable) (f) Working Humidity: <93% (g) RH Time-Delay: min: 10sec±3sec Max: 7min±2min (h) Installation Height: 2.2-4m (j) Power Consumption: 0.45W (work) 0.1W (static) (k) Rated Load: 1200W (incandescent lamp) 300W (energy-saving lamp) (l) Detection Motion Speed: 0.6 ~1.5m/s (m) Detection Distance: 6m max (24°C) Function: (a) Identification of day and night: (b) Consumer adjustable work ambient light. (c) Work in the daytime and at night are adjusted on the "sun" position (max). (d) Ability to work in the ambient light less than 3LUX on adjusted on the "moon" position (min). (e)Time-Delay is added continually on receipt of second induction signals after the first induction (f) Having compute time once more on the basic of the first time-delay rest. (g) Adjustable time delay having minimum time is 10sec±3sec. & maximum is 7min±2min as per requirement complete all as specified & directed. Make: Anchor (Panasonic)/ Impact (Honeywell)/ or equivalent.
S&F in repairs of Capacitor up to 2.5 Mfd MAKE KELTRON,EPCOS
S&F,in repair PVC laminated ISI marked top cover 3 mm including cutting/drilling holes for mounting housing of switches, sockets, etc as per site requirement suitable for following sizes of sunken/TW board. 4”x4” size
-Ditto- all as per Item No 111 here-in-before but 7”x4” size
-Ditto- all as per Item No 111 here-in-before but 8”x6” size
-Ditto- all as per Item No 111 here-in-before but 8”x10” size
-Ditto- all as per Item No 111 here-in-before but 10”x12” size
Supply and fix only plug top 3 pin 5 Amps capacity Make: Anchor ISI/LeaderISI/RIDER ISI
Supply and fix only plug top 3 pin 15/16 Amps capacity Make: Anchor ISI/LeaderISI/RIDER ISI
Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 0.75 sqmm 1100 volts grade all as specified and directed. Make Plaza, Havells
Supply and fix in replacement of copper water tank of 25 Ltrs capacity with and including necessary gasket packing, nuts, bolts, etc complete all as directed by Engr-in-Charge.
Fabricating, supply and fixing in replacement geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity for geysers of any make as per the existing one all as specified and directed
Supply & Fix in replacement flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed
Supply & Fix in replacement flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts
Taking down copper/ aluminum point wiring surface type, concealed type, flame proof type (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc.
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for the following: (a) One light / fan / bell point controlled by one switch.
(b) One 5A 2pin/3pin socket out let multipurpose on the same board with other switches.
(c) One 5A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 125 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board Note : A penalty of Rs 100 /- per point will be recovered from the contractor for not matching the disturbed surface with original.
S&F in Repairs/Replacement Ultra bright glass LED tube rod 20 Watts(Single/Double side connection), 230 volts with very high efficacy with G13 lamp holder including fixing arrangements and taking down old unserviceable tube rod complete. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 6 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping of 4.0 sqmm will be measured and paid one unit.
M&L for sub main wiring with two single core 1.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 1.5 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping of 1.5 sqmm will be measured and paid one unit. Note : A sum of Rs. 43,005.00 towards sch of credit shall be deducated to arrive the contract sum.
R J ENTERPRISES
sapana enterprises
M/S KHUSHI ENTERPRISES
KRISHNA ENGINEERS
Shree Ayyappa Engineering
joshua construction
Joy builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .