CGM (RE), APDCL
Bijulee Bhawan (Annex. Building, Paltan Bazar, Ghy 1
Creation of Electrical Infrastructure by construction of new 11kV line, new LT line, installation of new DTR for electrification of un-electrified Anganwadi Centres and Primary Schools under PKG No. APDCL/AWC and PS/GEC-II/04
2021_APDCL_22484_1
APDCL/SOPD/AWC and PS/2021/GEC-II/04
Open Tender
Electrical Works
Turn-key
60 days
Guwahati Elect. Circle-II
Please refer Tender documents
2 documents required · 2 mandatory
₹2,000
CGM(RE), APDCL
₹1 L
24 Jan 2022
25 Aug 2021
30 Sept 2021
25 Aug 2021
28 Sept 2021
25 Aug 2021
SUMMARY OF PRICE SCHEDULE
Description of Work / Item(s)
Supply, Erection, testing and Commissioning of New 11 KV lines:
Supply, Excavation and erection of PSC Pole, 8.50 Mt.(550 Kg.) incl. Grouting of PSC Pole with PCC as per scope of work, approved drawings and technical specifications.
Supply, Fitting & Fixing of 11 KV 'T' Cross Arm (GI) with angle size 50x50x6mm
Supply, Fitting & Fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm
Supply, Fitting & Fixing of Composite Polymeric 11 kV Pin Insulator
Supply, Fitting & Fixing of Composite Polymeric 11 kV Disc Insulator (70 KN) with H/W Fittings
Supply, Fitting & Fixing of Tension Clamp for Rabbit
Supply & Stringing of ACSR Rabbit Conductor in 11kV line including jungle cutting wherever necessary and as per direction.
Supply, Fitting & Fixing of Stay Set (HT) 50x8 mm Stay Clamp, Anchor Plate (200x200x6)mm 2 Nos. of Turn Buckles, 1.8 mtr long, 16 mm diameter Solid GS Stay Rod complete with digging of earth along with fitting
Supply, Fitting & Fixing of Guy Insulator (HT)
Supply, Fitting & Fixing of GI Stay wire 7/10 SWG
Supply, Fitting & Fixing of Galvanized Angle Cross Arm (50x50x6) mm for Cross Bracing for DP/TPs/FPs, as per T.S.
Supply, Fitting & Fixing of GI wire 6 SWG for Earthing
Supply, Fitting & Fixing of CI Earth Pipe 1.8 Mtr. long, 100 mm dia by digging of pit as per direction with necessary connection for Earthing as per direction
Supply, Fitting & Fixing of Jointing Sleeve for Rabbit
Supply, Fitting & Fixing of PG Clamp for Rabbit
Supply, Fitting & Fixing of AI. Binding Wire (10 SWG.)
Supply, Fitting & Fixing of Pole Clamp of GI flat (50x6) mm
Supply, Fitting & Fixing of Danger Plate 11KV
Supply, Fitting & Fixing of GI Nuts & Bolts with GI washer (Assorted)
Line Crossing - Line to line / Road: Excavation, Erection, testing and commissioning of Protective guarding as per REC construction standard, to be provided at locations where 11KV/33 KV line is crossing road, 11 KV line is crossing LT Lines/ P&T lines etc. Supplying 2 Nos guarding angle cross arm (50x50x6x2500)mm, 2 Nos guy with 7/3.14 mm wire, 2 Nos 16 mm diameter Eye-bolts, 2 Nos earthing of 100mm dia CI earth pipe 1800 mm long, 6 SWG GI wires for earthing connection, 6 SWG wire for guard wire, 8 SWG wire for cross lacing as per scope of work, approved drawings and technical specifications.
Supply, Fitting & Fixing Galvanized Angle Cross Arm (50x50x6X2500) mm for Guarding
Supply, Fitting & Fixing GI wire 8 SWG for Guarding as per T.S
Supply, Fitting & Fixing GI wire 6 SWG for Earthing
Supply, Fitting & Fixing I Hook GI
Supply, Fitting & Fixing of CI Earth Pipe 1.8 Mtr. long, 100 mm dia by digging of pit as per direction with necessary connection for Earthing as per direction
Supply, Erection, testing and commissioning of 11 kV, 150 Amp, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel, earthing etc. complete as per technical specifications, scope of works and approved drawings [For tapping points]
Supply, Fitting & Fixing of 11 KV DO Fuse 150A (Set of three)
Supply, Fitting & Fixing of Composite Polymeric 11 kV Pin Insulator
Supply, Fitting & Fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm
Supply, Fitting & Fixing of Galvanized Channel Cross Arm (100x50x6X2200) mm
Supply, Fitting & Fixing of GI Nuts & Bolts with GI washer (Assorted)
Supply, Fitting & Fixing of Pole Clamp of GI flat (50x6) mm
Supply, Fitting & Fixing of PG Clamp for Rabbit
Supply, Fitting & Fixing of GI wire 6 SWG for Earthing
Supply, Fitting & Fixing of CI Earth Pipe 1.8 Mtr. long, 100 mm dia by digging of pit as per direction with necessary connection for Earthing as per direction
Supply & Installation of new 11/.4kV 25kVA (4 star, Level II, BIS) Distribution Substation
Supply, Excavation and erection of PSC Pole, 8.50 Mt.(550 Kg.) incl. Grouting of PSC Pole with PCC as per scope of work, approved drawings and technical specifications.
Supply, Installation and commissioning of new 11/.4kV 25kVA (4 star, Level II, BIS) Distribution Substation
Supply, Fitting & Fixing of GI Channel Cross Arm (100x50x6X2200)mm
Supply, Fitting & Fixing of GI Flat (50x6 mm) Jam Clamp
Supply, Fitting & Fixing of Pole Clamp of GI flat (50x6)mm
Supply, Fitting & Fixing of Composite Polymeric 11 kV Pin Insulator
Supply, Fitting & Fixing of 11 KV DO fuse 150 A (Set of three) as per direction
Supply, Fitting & Fixing of 12 KV 9KA Lightning arrestor Line Type (Set of three) as per direction
Supply, Fitting & Fixing of Stay Set (HT) 50x8 mm Stay Clamp, Anchor Plate (200x200x6)mm 2 Nos. of Turn Buckles, 1.8 mtr long, 16 mm diameter Solid GS Stay Rod complete with digging of earth along with fitting
Supply, Fitting & Fixing of Guy Insulator (HT)
Supply, Fitting & Fixing of GI Stay wire 7/10 SWG
Supply, Fitting & Fixing of CI Earth Pipe 1.8 Mtr. long, 100 mm dia by digging of pit as per direction with necessary connection for Earthing as per direction
Supply, Fitting & Fixing of GI wire 6 SWG for Earthing
Supply, Fitting & Fixing of Rewirable Main Switch TPN (3Ph-4w),100 A (Outdoor type water proof) as per direction
Supply, Fitting & Fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of main switch meter box etc.
Supply, Fitting & Fixing of GI Nuts & Bolts with GI washer (Assorted)
Supply, Fitting & Fixing of Composite Polymeric 11 kV Disc Insulator (70 KN) with H/W Fittings
Supply, Fitting & Fixing of Tension Clamp for Rabbit
Supply, Fitting & Fixing of Danger Plate HT
Supply, Fitting & Fixing of ACSR Rabbit Conductor for jumpering
Supply, Fitting & Fixing of PG Clamp for Rabbit
Supply, Fitting & Fixing of PVC Cable 1-Core 50 sq. mm (Aluminium)
Supply, Fitting & Fixing of Bi-metallic Lug (assorted)
Supply, Fitting & Fixing of LT 3 - Ph CT Operated AC Static Trivector Meter; Accuracy Class 0.5 with Water proof Metering Cabinet.
Supply, Fitting & Fixing of LT CT 100/5 Amp, Accuracy Class 0.5
Supply, Fitting & Fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm)
Supply, Fitting & Fixing of Goat Proof Security GI Fancing for DTR along with Sign Board for DTR as per TS
Supply, Erection, testing and Commissioning of 11 KV, 400 A, 3-pole AB Switch for Distribution Transformer Substation along with support insulators, base channel down pipe, arcing horns etc. as per Technical Specification, approved Drawing & Scope of works
Supply, Fitting & Fixing of 11 KV Gang operated switch 400 A
Supply, Fitting & Fixing of GI Channel Cross Arm (100x50x6X2200)mm
Supply, Fitting & Fixing of Pole Clamp of GI flat (50x6)mm
Supply, Fitting & Fixing of CI Earth Pipe 1.8 Mtr. long, 100 mm dia by digging of pit as per direction with necessary connection for Earthing as per direction
Supply, Fitting & Fixing of GI wire 6 SWG for Earthing
Supply, Fitting & Fixing of GI Nuts & Bolts with GI washer (Assorted)
Supply, Fitting & Fixing of PG Clamp for Rabbit
Supply, Fitting & Fixing of I Hook GI
Supply, Fitting & Fixing of GI Channel Section (100x50x6X500)mm
Supply, Erection, testing and Commissioning of LT 1-Ph Line with ACSR Weasel Conductor on PSC pole
Supply, Excavation and erection of PSC Pole, 8.50 Mt. (550 Kg.) incl. boulder packing of 200 mm average size bolders mixed with excavated earth etc per pole at the bottom and surrounding the pole with thorough & vigorous ramming. The gaps between the boulders are to be filled by earth as per scope of work, approved GTP/drawings and technical specification.
Supply, Fitting & Fixing of GI LT Angle Cross Arm (40x40x6X500) mm
Supply, Fitting & Fixing of LT Pin Insulator (Porcelain) withGI Pin
Supply, Fitting & Fixing of LT Shackle Insulator
Supply, Fitting & Fixing of GI Shackle Straps with nuts & bolts
Supply & Stringing of ACSR Weasel Conductor in LT 1-Ph line including jungle cutting wherever necessary and as per direction.
Supply, Fitting & Fixing of LT Stay set
Supply, Fitting & Fixing of LT Guy Insulator
Supply, Fitting & Fixing of GI Stay wire 7/14 SWG
Supply, Fitting & Fixing of Danger Plate LT
Supply, Fitting & Fixing of Pole Clamp of GI flat (50x6) mm
Supply, Fitting & Fixing of GI Nuts & Bolts with GI washer (Assorted)
Supply & Installation of Service Connection to Anganwadi Centers & LP Schools as per technical specifications and scope of work
Supply, Fitting & Fixing of Un-armoured PVC Cable 2 core, 2.5 Sq mm.
Supply, Fitting & Fixing of GI wire 8 SWG (for Service Wire Carrier & earthing)
Supply, Fitting & Fixing of GI Pipe (25x1800) mm for earthing with required nuts-bolts & washer.
Supply, Fitting & Fixing of Cut-out (ISI)16 Amp.
Supply, Fitting & Fixing of Fibre Glass Reinforced (SMC) board 350x200x40 mm for fixing Energy Meter & Cut-out.
Supply, Fitting & Fixing of Plastic Tie of required size for tieing the PVC Service Cable and the GI carrier.
M/s. Jyoti Thakuria
M/s. Jyoti Thakuria
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .