Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹26.3 L+₹55,920 (2.18%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹30.0 L+₹4.3 L (16.6%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹33.0 L+₹7.3 L (28.4%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹33.9 L+₹8.2 L (31.9%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
GESU 52 2021 22 CLEANING AND REPAIR TO SEWAGE LINE SEPTIC TANKS SOAKAGE WELL ALLIED WORK TO MD ACCN UNDER AGE BR I GE SOUTH UDHAMPUR
2021_MES_490983_1
GE/S(U)-52/2021-22
Open Tender
Civil Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT documents
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹60,000
22 Feb 2022
27 Nov 2021
20 Dec 2021
27 Nov 2021
18 Dec 2021
11 Dec 2021
27 Nov 2021 - 7 Dec 2021
60 days
Amount
Desludging/Dewatering of septic tank/ soakage wells including inlet/outlet chambers removing out all scum, siltresiduals sludge (both) organic or inerganic nature) after plugging the incomming sewage lines through combined high presure water jetting cum suction (vaccum) typer machine nmounted on LCV/HCV facility of high presure vaccum and removing the same in the tank to a place outside contoment meant for the purpose by local municipality complete all as specified and directed by Engr-in-Charge.
Cleaning of gully traps of any size and removing waste material etc. to a distance not exceeding 50 m and burrying in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge. Note :- The cost for excavation and earth work for pits is deemed to be included in the unit rate.
Cleaning of SGSW/NP-2 pipes of any dia/bore by rodding from manhole to manhole or manhole to septic tank or vice versa and well flushing with water after cleaning and removing waste material etc to a distance not exceeding 50 m and burrying in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge. Note :- The cost for excavation and earth work for pits and taking off manhole cover and placing the same in position after cleaning is deemed to be included in the unit rate.
Cleaning of manholes not exceeding 1.5 m deep and removing sludge/waste material etc to a distance not exceeding 150 m and burrying in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge. Note :- The cost for excavation and earth work for pits is deemed to be included in the unit rate.
Decription all as per ser item No 4 here-in-before above but exceeding 1.50 m deep and not exceeding 3.0 m deep complete all as specified and directed by the Engr-in-Charge.
Cleaning cast iron pipes 100/75 mm bore by rodding with jute bags and well flushing after cleaning complete all as specified and directed.
Cleaning of floor traps and removing waste material etc to a distance not exceeding 50 m and burrying in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge. Note :- The cost for excavation and earth work for pits is deemed to be included in the unit rate.
Cleaning of 'P' traps in WC and removing waste material etc to a distance not exceeding 50 m and burrying in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge. Note :- The cost for excavation and earth work for pits is deemed to be included in the unit rate.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
100 thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
Precast coloured machine pressed/ vibro mechanically floated interlocking concrete paver block, any shape and size confirming to IS-15658-2006 of 80 mm thick M-40 Grade, with topping of cement mixed with imported pigment Red/yellow laid over and including 40 mm thick sand cushion over prepared beases. Colour and shape shall be approved and complete all as specified and directed by Engr-in-Charge. Make : Ultra/Modern/ISI Marked.
100 thick PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) in floors and finished even and fair complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoines arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and directed.
Decription all as per ser item No 14 here-in-before but except bricks complete all as specified and directed.
Walling of random rubble uncoursed, brought up to course well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
Decription all as per ser item No 16 here-in-before but except stone complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Raking out joints/pointing to random rubble or masonry complete all as specified and directed.
15 mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:4 and finished even and fair without using extra cement complete all as specified and directed.
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:3 complete all as specified and directed.
Preparing surfaces newly plastered and applying two coats of cement base paint on walls complete all as specified and directed.
Demolition of cement concrete (reinforced) Roofs, floors (other than ground floors), beams staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200 mm thick surface horizontal or sloping, rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 5 cm wide but not exceeding 10 cm wide, surface flat for rough finished surface of concrete complete all as specified and directed.
Cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in copings including necessary form works complete all as specified and directed.
Precast cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slabs, (for man holes) chullah hoods, chajjas, shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and directed.
TMT bars 10 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
TMT bars 6 to 8 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Mild steel framed work such as door or gates of angle or other section with gusset plates, rails braces etc. with ornamental and intricate design complete drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging, also fastening and fixing including shop coat of zinc chromate paint conforming to Fe-290 Gde E-165 complete all as specified and directed.
Providing cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregates) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed.
Providing 50 mm thick cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type of soil/strata for foundation etc. or for shafts, wells, drain pipes and getting out complete all as specified and directed.
Decription all as per ser item No 36 here-in-before but depth exceeding 1.5 m and not exceeding 3.0 m complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50 m and deposited where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
Providing cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
Demolition and bracking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar internal dia of pipe 200 mm complete all as specified and directed.
Decription all as per ser item No 41 here-in-before but 150 mm dia complete all as specified and directed.
Decription all as per ser item No 41 here-in-before above but 100 mm dia complete all as specified and directed.
RCC pipes 200 mm dia, class NP-2, laid and jointed complete with clamps complete all as specified and directed.
Decription all as per ser item No 44 here-in-before above but 150 mm dia complete all as specified and directed.
Salt glazed stone ware drain pipes of internal diameter 200 mm grade 'A' conforming to IS-651 laid in trenches and jointed complete all as specified and directed.
Salt glazed stone ware drain pipes of internal diameter 150 mm grade 'A' conforming to IS-651 laid in trenches and jointed complete all as specified and directed.
Salt glazed stone ware drain pipes of internal diameter 100 mm grade 'A' laid in trenches and jointed complete all as specified and directed. Make : TFC, Bhaskar, M/s Perfect Potteries Jabalpur
Concrete bed to drain pipes of bore 200 mm including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) including necessary shuttering and supports complete all as specified and directed. Note:- (i) Thickness of bed belew barrel of pipe - 10 cm (ii) Width of bed :- outer dia of pipe plus 30 cm.
Decription all as per ser item No 49 here-in-before above but 150 mm dia drain pipes complete all as specified and directed.
Decription all as per ser item No 49 here-in-before above but 100 mm dia drain pipes complete all as specified and directed.
Dismantling cast iron, AC, reinforced concrete and PVC pipe of any description or dia fixed with wall or taking out from trenches complete all as specified and directed.
100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints laid in trenches or in floors complete all as specified and directed.
Decription all as per ser item No 53 here-in-before above but 75 mm bore complete all as specified and directed.
100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to wall complete all as specified and directed.
Decription all as per ser item No 55 here-in-before above but 75 mm bore complete all as specified and directed.
100 mm bore CI Bend (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
75 mm bore CI Bend (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
Decription all as per ser item No 58 here-in-before above but 100 mm bore pipe fitted with oval access doors complete all as specified and directed.
Decription all as per ser item No 58 here-in-before above but 75 mm bore pipe fitted with oval access doors complete all as specified and directed.
110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
Decription all as per ser item No 61 here-in-before above but 75 mm bore pipe complete all as specified and directed.
110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed.
Decription all as per ser item No 63 here-in-before above but 75 mm bore pipe complete all as specified and directed.
110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
Decription all as per ser item No 65 here-in-before above but 75 mm complete all as specified and directed.
Cast iron 'P' or 'S' trap for bore of pipe 100 mm complete all as specified and directed.
Cast iron floor trap with dia of outlet 75 mm with CI grating including jointing to waste pipe fixed in cement concrete PCC 1:2:4 type B-1 complete all as specified and directed.
Stack clamps made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore complete all as specified and directed.
Stack clamps made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore complete all as specified and directed.
Cutting into existing manholes/septic tank/sokage pits for connecting new drains of 150 mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
Loose filling with broken bricks of gauge 80 to 150 mm in soakage pits, sokage wells complete all as specified and directed.
Viterous china squatling Pan orisa pattern size 580 x 440 mm white, with integral feat reots including connection to trap and to flush pipes etc and excluding flushing cistern and flush pipes fixed in repair complete all as specified and directed.
Note : (a) Contractors representative /Engineer will report to Engr-in-Charge/concern JE daily in morning to collect complain for routine/urgent works related to sewage/blokage maintenance till completion of contract. (b) All routine/urgent jobs received on docket slip shall be attended within 24 hrs. If the nature of job is such that which cannot be completed within 24 hrs, it shall be immediately brought in to the notice of Engr-in-Chrage, (c) The period for working to the such complains shall be decided by GE/Engr-in-Charge. If delay is more than 24 Hrs & GE/Engr-in-Charge is not satisfied with reason for delay in working then the penalty of Rs 300/complain/day shall be recovered from contractor. (d) In case of any dispute arising from above the decision of Accepting Officer shall be final and binding.
AKBAR FURNITURE HOUSE AND TIMBER MERCHANT
VISHWANATH AND SONS
M/S P S CONSTRUCTION
S K BROTHERS
RAJ MOHD
M/S GURU DEV BUILDERS
K S BUILDERS
sohtra and co
M/S GH MOHAMMAD DAR
VIRINDER SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .