Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC Lowest tender accepted | |
| 2 | L2₹1.7 L+₹3,200 (1.91%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹1.7 L+₹4,700 (2.81%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹1.7 L+₹5,200 (3.11%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹1.8 L+₹12,700 (7.59%)Rejected-Finance C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | L5 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
Closing Date
5 Oct 2024, 6:00 pmClosed
GE (AF) Subroto Park Delhi Cantt
GE (AF) Subroto Park Delhi Cantt
REPAIR/MAINT AND SERVICING OF TOWER/CASSETTE TYPE AC UNITS CAPACITY 3.5 TR AND 4.0TR (8 NOS) INSTALLED AT HQ WAC AREA AT SUBROTO PARK
2024_MES_676117_1
3104/005/E3
Limited
Miscellaneous Works
Piece-work
30 days
Delhi Cantt
Please refer tender documents
1 document required · 1 mandatory
₹0
Exempted
26 Oct 2024
23 Sept 2024
7 Oct 2024
25 Sept 2024
5 Oct 2024
25 Sept 2024
Amount
JOB ORDER FOR : REPAIR/MAINT & SERVICING OF TOWER/CASSETTE TYPE AC UNITS CAPACITY 3.5 TR & 4.0TR (8 NOS) INSTALLED AT HQ WAC AREA AT SUBROTO PARK . The following work are urgently required :-
M & L for dismantling of complete unit and De-brazing the suction and discharge tubing from the unserviceable compressor, dis-engaging the foundation bolt, disconnecting electrically and taking out the unserviceable compressor from the condensing unit of capacity 3.5/4.0 TR. up to the entire satisfaction of the Engr-in -charge: -Qty 03 Job MAKE: Blue star
Supply and Fixing in replacement compressor of capacity 4.0TR make- Emerson-Copeland 3 phase, 14850 watt including necessary electrical connections fixing with carefully inside the condensing unit, tightening of foundation bolts, brazing of suction and discharge tubing, testing etc all as specified and directed by Engineer -in- Charge.:-Qty 01 Nos.
Supply and Fixing in replacement compressor of capacity 3.5TR make- Emerson-Copeland 3 phase, 12400 watt including necessary electrical connections fixing with carefully inside the condensing unit, tightening of foundation bolts, brazing of suction and discharge tubing, testing etc all as specified and directed by Engineer -in- Charge. Qty 02 Nos.
M & L for Pressuring the Tower/Cassette AC unit 3.5 TR & 4.0 TR with nitrogen to detect and repair the leaking area by brazing all as required, if leaking found necessary leak arresting, brazing to be carried out and de-hydration of the unit with vaccum pump upto minus 30 PSI. all as specified and direced by Engr-In-Charge:-Qty 06 Job
Supply and filling the refrigerant R-22/R32 in the unit of capacity 3.5 TR & 4.0 TR upto the required level.all as specified and directed by Engr-in-Charge:-Qty 20 Kgs.
M&L for repair to unserviceable cordless PCB remote control unit any type normal or inverter of Cassette type AC 4.0 TR, including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and as directed by Engr-in-charge:-Qty 01 Nos
M&L for repair to unserviceable cordless PCB remote control unit any type normal or inverter of Tower type AC 3.5/4.0 TR, including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and as directed by Engr-in-charge:-Qty 03 Nos
Supply & fixing in replacement of unserviceable Condenser motor three phase suitable for tower type AC of cap 3.5 TR as per existing size and model complete all as specified and as directed by Engr-in-charge:-Qty 02 Nos
Supply & fixing in replacement of unserviceable Condenser motor three phase suitable for Cassette type AC of cap 4.0 TR as per existing size and model complete all as specified and as directed by Engr-in-charge. :-Qty 01 Nos
M & L for dis-engaging condensing unit top cover, carry out the servicing to condenser coil with chemical and pressurized water jet, checking all power and control connections, cleaning evaporator coil filters, checking drainage system, checking level of refrigerant and testing all units with propper servicing with smooth functioning all as specified and directed by Engr-in-Charge:- Qty 8 Job.
NOTE:- (a) AGE E/M-I Demand No 302/WO/202/EM-II dated 02 Jul 2024 (b) CH Head : 51/761/06 (c) Schedule of credit Rs. 9600.00 will be recovered from contractor against old material. Old unserviceable retrieved materials shall be the property of the contractor.
Sumit Enterprises (BID ID -3122773)
C K ENTERPRISES (BID ID -3122280)
PRAGATI ASSOCIATES (BID ID -3126403)
M/S Satyam Associates (BID ID -3123696)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_756072.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .