Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC AT DHORI STAFF QTR PO DHORI DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | L1 | Accepted-AOC awarded | |
| 2 | Rejected-Technical AT KARGALI BAZAR PO BERMO DIST BOKARO PIN 829104 | BERMO | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical not evaluated | |
| 3 | Rejected-Technical | - | Rejected-Technical not evaluated |
Tender Value
Refer Docs
EMD Value
₹2,300
Closing Date
29 Aug 2022, 10:00 amClosed
PE EnM AADOCM
Office of the PE EnM AADOCM
Reorganisation of 440v OH line with electrical wiring
2022_CCL_254081_4
CCL/Dhori/AADOCM/EnM/22-23/12
Open Tender
Electrical and Maintenance Works
Item Rate
8 days
AADOCM Project
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,300
18 Dec 2022
22 Aug 2022
30 Aug 2022
23 Aug 2022
29 Aug 2022
23 Aug 2022
23 Aug 2022 - 25 Aug 2022
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Above 10.00 metre and upto 12.00 metre.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Errection of all alluminium conductor of 7/2.11 mm to 7/3 .10 mm diametet in cluding binding etc as required
S/E 'D' iron with LV/MV 100mm shackle insulator
Supply and providing of G.I.wire 8 SWG/Kg
Errection of GI wire no. 8 SWG including binding etc. as required.
Errection of creddling guard
Transportation of pole.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Service wire for main switch.7x1.5 Sq.M.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.
Fitting and fixing of light fittings top on the pole.
G.I.nuts and through bolts with washer
Total impact of GST for the purpose of CTC
M/S CHHOTTANAGPUR SUPPLY AGENCY
M/S A N TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .