Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC C 17 UPPER GROUND FLOOR C BLOCK COMMUNITY CENTRE JANAK PURI JANAK PURI JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹1.7 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹1.9 Cr+₹15.9 L (9.23%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹1.9 Cr+₹15.9 L (9.23%) | L2 | Rejected-Finance L2 bidder |
| 3 | L3₹2.1 Cr+₹35.2 L (20.4%)Rejected-Finance | ₹2.1 Cr+₹35.2 L (20.4%) | L3 | Rejected-Finance L3 bidder |
| 4 | L4₹2.5 Cr+₹81.9 L (47.4%)Rejected-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | ₹2.5 Cr+₹81.9 L (47.4%) | L4 | Rejected-Finance L4 bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not submitted the shortfall documents as required |
Tender Value
₹2.1 Cr
Closing Date
12 Mar 2021, 6:00 pmClosed
AGM (Engg-E)
Srinagar Intl Airport
Construction Of Cargo Complex At Srinagar Intl Airport, Srinagar (SH Electrical Works)
2021_AAI_69146_1
AAI/SNR/ENGG(E)/CARGO/2020-21
Open Tender
Electrical Works
Works
120 days
Srinagar Intl Airport
Please refer Tender documents.
16 documents required · 16 mandatory
₹1,120
Exempted
7 Jul 2022
22 Feb 2021
15 Mar 2021
23 Feb 2021
12 Mar 2021
23 Feb 2021
23 Feb 2021 - 1 Mar 2021
Amount
SH-I: INTERNAL & EXTERNAL ELECTRICAL INSTALLATIONS
Supply of 2'X2' recess/ surface mounting 34/36W full window LED light fixture having white powder coated CRCA housing with heat sink, driver and front frame with translucent cover complete with all accessories as per technical specifications of tender document.
Supply of 60W Highbay fitting made of powder coated Aluminium housing having operating Voltage Range of 140 to 270V AC supply complete with all accessories as per technical specifications of tender document.
Supply of 80W Highbay fitting made of powder coated Aluminium housing having operating Voltage Range of 140 to 270V AC supply complete with all accessories as per technical specifications of tender document.
Supply of 100W Highbay fitting made of powder coated Aluminium housing having operating Voltage Range of 140 to 270V AC supply complete with all accessories as per technical specifications of tender document.
Supply of 15/ 18 watt round/square shape recess mounted LED Down lighter complete with all accessories as per technical specifications of tender document.
Supply of 18/20 watt LED Batten of 4ft complete with aluminimum extruded LED tube complete with all accessories as per technical specifications of tender document.
Supply of 10W Mirror LED Light luminaire complete with all accessories as per technical specifications of tender document.
Supply of 70 watt LED Street light with pressure die- cast aluminium cover on both side for holding extruded aluminium heat sink, with heat resistant toughened glass with control gear complete with all accessories as per technical specifications of tender document. .
Supply of 1200mm dia sweep ceiling fan copper wound with double ball bearings, blades white in color, ISI marked complete with capacitor, down rod, split pin , reel but without regulator complete as required.
Supply of 300mm dia sweep wall fan with Oscillating type complete with built in String type speed regulator and mounting arrangement. (Similar to Havells make - SWING HS or equivalent)
Supply of 450mm dia sweep Heavy duty wall mounted air circulator oscillating type, Hi speed with 3 speed push buttons, RPM>=1400, with guard and mounting arrangement. (Similar to Bajaj make - Supreme plus air circulator 450 mm wall or equivalent)
Supply of 300 mm Exhaust Fan suitable for operation on 230 volt AC supply
Supply of 450mm dia heavy duty exhaust fan having 1400 rpm suitable for operation on 230 volt AC supply .
Supply of 35 Ltr Capacity storage type Geyser ABS body suitable for 230V single phase 50Hz A.C supply with all accessories. (Make-Havells/Bajaj or Equivalent)
Installation, testing and commissioning of pre-wired, LED fitting with driver/ fluorescent fitting / compact fluorescent / street light on Pole & Boundary light with L shape bracket/ fitting of all types, complete with all accessories . directly on ceiling/ wall/ surface, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Installation of Bracket mounted/Wall mounted fan in wall/Pillers i/c connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Installation, Testing & commissioning of existing 35 Ltr storage type Geyser etc as reqd.
Supply of following size of 1.1 kv grade multicore aluminium conductor, XLPE insulated and PVC sheathed armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments.
4core x 10 sqmm
4 core x 16 Sq.mm.
3.5 core x 25 Sq.mm
3.5 core x 50 Sq.mm.
3.5core x 400 Sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/PVC pipe as required
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Tagging on both the ends will be done with aluminium tags etc. complete as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making indoor end termination with brass single compression gland (Heavy duty type) and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor armoured cable of 1.1 KV grade as required.
4 core x 10 Sq.mm.
4 core x 16 Sq.mm.
3.5core X 25 Sq.mm.
3.5core X 50 Sq.mm.
3.5 core X 400 Sq.mm.
Supply & Laying of following sizes HDPE pipe ISI marked conforming to IS 14930, Part-II along with all acessories like socket, bend, couplers etc complete with fitting and cutting, jointing etc direct in ground (75 cm below ground level) including excavation & refilling the trench with same excavated earth but excluding sand cushioning and protective covering etc. , complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply & Laying of 150 mm (OD) / 135 mm (ID) (nominal) dia, PN8 HDPE pipe as per IS 14930 through trenchless technology by drilling the bore of suitable dia directly in ground upto the depth of 3 meters from the ground level including necessary joining, coupling, splicing etc complete as required
Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size PVC insulated and PVC sheathed/XLPE aluminum conductor cable, etc complete as required.
3.5 X 400 sq. mm
Providing an laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) etc. including form work etc. as required in excavated trench for road crossing of cable in pipe.
Supplying and fixing cable route marker with 10cmx10cmx 5 mm thick GI Plate with inscription thereon , bolted/ welded to 35x35x6 mm angle iron of 60 cm long and fixing the same in ground as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and fixing 6 way, polycarbonate type SPN with Acrylic door , MCB distribution board,230 V, on surface, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, including earthing etc. as required. (But without MCB/RCCB/ Isolator)
Supplying and fixing 25 A rating, Single pole and neutral, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
6 way (4+18), Double door
Supplying and fixing 5 amps to 32 amps rating, 240 volts miniature circuite breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required.
Single Pole 'C' series
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recess steel conduit as reqd.
2 x 1.5 sq.mm. + 1 x 1.5 sq. mm. earth wire
2 x 2.5 sq.mm. + 1 x 2.5 sq. mm. earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
S/F light plug point Modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
S/F power plug point modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing call bell(Ding-Dong) suitable for A.C. single phase, 230 volts, complete as required.
Supplying and fixing following size/modules,GI box alongwith modular base & cover plate for modular switches in recess etc. as required
1 or 2 Module (75 mm X 75 mm)
6 Module (200mmX75mm) (Computer Point)
Supplying and fixing following modular type switch/socket on the existing switch box/cover including connections etc. as required.
Telephone socket outlet with shutter
TV antenna socket outlet
RJ-45 socket outlet with shutter
5/6 A switch
3 pin 5/6 A socket
15/16 A switch
6 pin 15/16 amp socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 2.5 sq. mm
6 x 2.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
3x 6 sq. mm
6x 6 sq. mm
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels
Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with Al. foil & Al. braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of suitable size of telephone distribution (DP) boxes made of 2 mm thick GI sheet, powder coated including krone modules with all mounting accessories including necessary termination.
Suppply & laying, connection, testing & commissioning of following multi core copper conductor of 0.50 mm nominal dia telephone armoured cable conforming to IS:1554(Part-1)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of Cable
2 run of Cable
3 run of Cable
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supply of 08 meters height GI OCTAGONAL pole continuously tapered galvanised street light pole with maximum 1.5 meter long single arm GI bracket (length of bracket shall be based on design) for installation of LED street light luminaire and fabricated out of 3 mm MS plate in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (200x200x12mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with 32 Amp heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 06 Sq.mm cables & 0.5A DP MCB for each fixture connections, earthing bolts for continuous earth connection complete as required & as specified.
Erection of metallic/OCTAGONAL pole of length 08 meter in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including i/c making the foundation, excavation and refilling etc. as required.
High Mast: Design, Supply, installation, testing and commissioning of 16M high mast shaft in two section suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 8 luminaires in symmetrical arrangement and other accessories manufactured in factory with the following accessories etc, as required as per the additional specification. (i) Raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual lumi (ii) Foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template including RCC/CC foundation as recommended by the OEM for installation of above high mast. (iii) Supply & installation of 08 nos. 200W LED Flood Light having Lumen output minimum 24000 Lumens, IP 66, IK08 (iv) Supply & Installation of LED type single dome aviation obstruction light. (v) SITC of outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals.
SH-II: EARTHING, LIGHTINING ARRESTER & SURGE PROTECTION
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Supply & Installation of 8mm Aluminum Solid Round Conductor to make horizontal air terminal at terrace, grid size shall be as per drawing to meet the requirements for IS/IEC 62305 and IEC 62561-2. Conductor should be tested for its Electrical, Mechanical and Chemical properties as per IEC 62561. test certificate should be provided by the manufacturer.
Supply & Installation of aluminium ferrule for extension of 8 mm solid aluminium conductors .
Supply & Installation of stainless steel holder at every one metre for roof and wall (sheer area)suitable 8 / 10 mm round conductor for Metal Roof sheet components are meet the requirements for IS/IEC 62305 and should be tested for its Electrical, Mechanical and Chemical properties as per IEC 62561. test certificate shold be provided by the manufacturer.
Supply & Installation of heavy duty adhensive glue to stainless steel roof conductor holder on Metal Roof sheet for horizontal Air terminal.
Supply & Installation of Stainless steel cross connector suitable for 8 / 10 mm round conductor ,components meet the requirements for IS/IEC 62305 and should be tested for its Electrical,Mechanical and Chemical properties as per IEC 62561. test certificate shold be provided by the manufacturer.
Supply & Installation of Expansion Piece with ferrule to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations, to be provided on conductors length over 20 meters or as per drawing, components are to meet the requirements for IS/IEC 62305.Tested for its Electrical, Mechanical and Chemical properties as per IEC 62561.
Supply & Installation of bridging cable to connect horizontal air terminal to connect with the metal column all components are to meet the requirements for IS/IEC 62305.Tested for its Electrical, Mechanical and Chemical properties as per IEC 62561.
Supply & Installation of Stainless steel Conductor Holder for holding the down conductor on the bricks wall at every one metre, meet the requirements of IS/IEC 62305.Tested for its Electrical,Mechanical and Chemical properties as per IEC 62561.
Supply & Installation of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
Supply & Installation of 10mm copper bonded steel solid conductor for ring Earthing, all down conductor shall connected with Ring earthing , Conductor should be minim 100 micron copper bonded and CPRI Tested for short circuit current min 12 kA peak. Conductor shall be horizontal laid in soil at min. 600mm below ground level and 1 metre distance from the building wall, components should tomeet the requirements of IS/ IEC 62305 and IEC 62561-2
Supply & Installation of UL listed maintenance free copper coated earth rod with 250 micron copper coating with clamp made of stainless steel for terminating cable / flat conductor. PP material inspection pit which can handle 5 kN point load. Earth enhancing mineral (PROSAN) compound tested for Leaching & TCLP with NABL accredited lab. The systems shall be conforming to IS 3043, IS / IEC 62305, IEC 61643-5-54, UL 467 and the rod tested for dimention, marking, tensile strength, salt mist, coating thickness, electrical resistivity test before and after corresion test etc as per IEC 62561-2. Set Consist of following BOM (1) Earth rod of 3 mtr length having the dia of 14.2 mm (2) 12.5 Kg bag x 2 nos (3) Universal Clamp SS (4) Chamber Inspection Pit) made up of PP material.
Supply & installation of Testing & commissioning of Type 1 SPD according to EN 61643-11, Lightning current & Surge Protection Device at mains LT panel (3 phase, 415 V) for (LN) Single-pole combined lightning current and surge arrester with Follow current extinguishing capability: up to 100 kArms;Energy-coordinated according to IEC 62305-4 with arresters of the Red/Line series and terminal equipment,Temporary overvoltage (TOV) 440 V /120 min. withstand, remot signalling P/N: 961205. and Type 1 SPD according to EN 61643-11, Lightning current & Surge Protection Device at mains LT panel (3 phase, 415 V) for (NPE) Single-pole combined lightning current arrester, Lightning impulse current (10/350): 100 kA;Follow current extinguishing capability: 100 Arms at 255 V a.c.,TOV resistance: 1200 V/200 ms; with remote signalling with MCB 4 Pole 63 amp Heavy duty transparient enclosure IP-67. and KEMA Approved P/N:961185 Make Dehn.
Supply, Installation, testing and commissioning of 240 kA 3 phase 4 wire Digital Portable Low Impedance equipment Grounding & bonding system with built in 100% Lightning and Surges suppressor, static charge, Noises, ESD, EPR and abnormal electrical characteristics eliminator which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V, a digital 6 digit lightening surge counter, self health visual status indicator, built in Aerosol based fire Extinguisher and ON-LINE remote monitoring facility of Earth-Neutral voltage in a Pre-wired pulverulent body painted metal enclosure to be connected in parallel to the power supply circuit, Conforming to IEC , CE Marked, CPRI tested & ISO 9000 & ISO 14001-2015 certified. Make in India, Model: DSP-Prime-MII-3P4-240
Supply & Installation of Self actuated (thermaly & Electrically non pressurized, Strong & Light weight, impulse dry power Module suitable for extinguish A,B,C & E type of fire for the protection of 15 cu. mtrs volume Model : Buran 2.5 of EPTOS or equivalent of FCDT SOYUZ/Pyrogen to be installed in Switch room
Supply & Installation of Thermal Activation Device (TAD) Model USP 101 or equivalent
Supply of Self Operated Aerosol based fire Extinguisher for the protection of 0.1 cubic mtrs of enclosed space using 8 gms. of Aerosol Model :Tor-02A of EPOTOS or equivalent of FCDT SOYUZ /Pyrogen
SH-III: FIRE FIGHTING & HYDRANT SYSTEM
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia.
80 mm dia.
100 mm dia.
150 mm dia.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
150 mm dia.
Supplying, fixing, testing and commissioning of butterfly valve of PN1.6 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm dia
150 mm dia
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. a) 100 mm dia
Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia..
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
80 mm dia
150 mm dia
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing of 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Gun Metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required 4 way - 150 mm dia M.S. Pipe
Supplying and fixing of Fire Hose Cabinet (External) 900mm x 600 mm x 500 mm made of 2mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangements suitable to accommodate external yard hydrant with butterfly valve, 2Nos. 15mtr.long Hose pipe, 1No. branch pipe, mounted on wall OR raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant, as required.
Providing and fixing Fire Hose Cabinet (Internal) fabricated from 16 gauge M.S. Sheet with single or double glazed front door and locking arrangement, painted "Fire Red" with powder coated paint "Fire Hose" written on front including suitable supports to place 900 mm above ground level, approximately size (minimum) 1200x900x450 mm deep, suitable to house following; (i) Single Headed Outlet - 2Nos. (ii) First Aid Hose Reel (Length of pipe shall be such that nozzle of the hose can be taken into every room and within 6 Mtrs. of any part of the rooms keeping in view layout and obstruction.) - 1 No. (iii) Hose pipe 63 mm dia 15m long with male and female coupling at both ends. - 2 Nos. (iv) Branch pipe 63 mm dia with 20 mm (nominal internal diameter) nozzle and suitable for instantaneous connection - 1 No
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
150 mm dia.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required
1000mm long
Jockey Pump: Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket complete as required & as per specifications.
Supply, installation, testing and commissioning ISI marked (IS:15683) portable fire extinguisher, water (gas pressure) type capacity 9 kg with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets complete as required & as per specifications.
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher, Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket complete and conforming to IS:15683 as required and as per specifications
Providing & fixing a set of 4 Nos. 9.5 Liter capacity GI bucket painted in post office red colour and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand complete as required.
SH-IV: FIRE ALARM AND DETECTION SYSTEM
Supply, Installation, Testing & Commissioning of Networkable Microprocessor based intelligent analog Addressable Type Fire Alarm Control Panel of 2 loop Expandable upto 6 Loop, with minimum 320 character graphics / 15000 Pixel / LCD / LED display with touch screen or other keypad and minimum 1000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intelligent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient number of programmable relay controls for controlling pressurization fans, ventilation fans, fire pump room, monitoring of fire sprinkler and fire hydrant pump etc, suitable for operation at 230 volts, 50 Hz AC power supply including automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and shall be capable of operating the system for 30 minutes during an emergency / fault conditions in addition as required. The panel shall be UL/EN listed (Latest Version). It shall have facility to interfac (BACNET/ MODBUS/ Open protocol gateway) with Building Management System complete as required.
Supply, Installation, Testing & commissioning of UL/EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base / Isolator Module and with unique optical sensing chamber, visible LED, fully coated circuit board, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling, roof and concealed space and as per enclosed specifications. (Cost of plug in common base/box shall deemed to be included in cost of detectors)
Supply, Installation, Testing & commissioning of UL/EN listed (latest version) intelligent addressable Intrinsically Safe Smoke Detector with Protocol converter, barrier and all other accessories for hazardous storage area with visible LED, fully coated circuit board, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling, roof and concealed space and as per enclosed specifications. (Cost of plug in common base/box shall deemed to be included in cost of detectors)
Supply, installation, testing and commissioning of UL/EN listed (Latest Version) intelligent Addressable type Heat Detector (Fixed cum-rate of rise type) with inbuilt fault isolator / isolator base / Isolator Module w ith range upto 57° C complete with all fixing accessories like base, base box, self adhesive sticker indicating loop number and address etc. to be installed below / above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required.
Supply, installation, testing and commissioning of UL/EN listed (latest version) Intelligent addressable Control Module/ Relay Module (output module) with inbuilt fault isolator or isolator module for tripping of AHU & Ventilation / pressurisation fans / hooter complete with termination etc. as required and as per enclosed specifications.
Supply, installation, testing and commissioning of Response Indicator for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete as required.
Supply, Installation, Testing & commissioning of UL/EN listed (latest version) intelligent addressable Manual call station (pull/Push type) suitable for semi flush mounting with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test-reset lock, electronic or rotary switches for address setting. Manual pull station shall be connected with two wire to SLC loop of Fire Control Panel. Cover shall be made out of LEXAN (or poly carbonate) with clear operating instruction and the word "FIRE" appearing on the front complete with connections etc. as required and as per enclosed specifications.
Supply, installation, testing and commissioning of UL/EN listed (latest version) loop powered addressable Hooter- cum- strobe with inbuilt fault isolator / isolator module with minimum 90 dB output at a distance of 1 mtr. complete with termination etc. as required and as per enclosed specification.
Providing, installation, testing & commissioning of UL/EN listed (Latest Version) Monitor Module with inbuilt fault isolator / isolator module (for monitoring different electrical/mechanical device etc) as per specifications.
Supply and laying of 2C x 1.5 sq. mm, PVC insulated FRLS Armoured copper cable for SLC Loop & Power Supply, confirming to standards and specifications including terminations, connections & all labour and material etc. complete as required (For fire detection signal).
Supply, installation testing and commissioning of UL Listed/ EN54 listed, Vds approved beam detectors refelection type with soft addressable intelligent monitor module including powe supply unit & other accessorie complete as required as per specification.
SH-V: VRF SYSTEM & High Wall Split Acs
Supply Installation, Testing & Commissioning of 22 Hp (Heating & Cooling) modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Make: Toshiba/ Daikin/ Trane) Ambient Temp. (+) 35 Deg. Cent. Minimum Tem. (-) 10 Deg. Cent.
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
Hiwall Type with Cordless Remotes for 2.0 HP
Supply, Installation, Testing and Commissioning of copper Y-Joints suitable for gas and liquid line of VRF System complete as required for the above system.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
28.6 mm O.D. (insulation : 19 mm)
22.2 mm O.D. (insulation : 19 mm)
19.1 mm O.D. (insulation : 13 mm)
15.9 mm O.D. (insulation : 13 mm)
12.7 mm O.D. (insulation : 13 mm)
9.5 mm O.D. (insulation : 13 mm)
6.4 mm O.D. (insulation : 13 mm)
Supply, installation, testing and commissioning of following Drain piping made of rigid uPVC pipe Class - 3 (6 kg/cm2) confirming to IS 4985-2000 complete with fittings, supports etc. as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
40 mm dia
25 mm dia
Supply, Installation, Testing & Commissioning of Control cum Transmission shielded wiring of 2 core x 1.5 sqmm copper in suitable PVC conduits (Medium Duty) between indoor and out door unit.
Supply and laying power cable for outdoor & indoor units of following sizes
2 Core 1.5 Sqmm Cu Cable
4 Core 16 Sqmm Cu Cable
Supplying and installating 300mm width x 50 mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron Cable Tray(Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts&nuts etc as required
Supply, Filling, Testing & Commissioning of Refrigerant Gas R-410
Supply, Fabrication & fixing of MS Stand suitable for installation of VRF Outdoor Units
Providing & fixing 63 Amp, 4 pole MCCB complete with MS Enclouser and having following protections i.e under voltage, over voltage, single phase preventor, phase sequence preventor, etc. as required at site.
SITC of PUSH BUTTON / TOUCH TYPE Centralized Remote Controller for controlling minimum 20 number of Indoor Units.
Supply, installation, testing & commissioning of following rating, Inverter type, minimum 3 Star rated, Hi-wall, Split air-conditioner with hermetically sealed rotary/ twin rotary/ swing type compressor operating on refrigerant R-404a/ R-410a/ R-32.The body of indoor unit shall be made of ABS/HIPS/GS & having all safety, air filters, evaporator, condenser, cordless remote, electronic operation control & all accessories supplied with the unit by OEM etc as per manufacturer standards suitable for operation on 230 volts , 50 Hz, Single phase, AC supply, complete with refrigerent piping, control & power cable from outdoor to Indoor etc. up to 3 meter complete as required at site.
1.4/1.5 TR (Hot & Cold)
Supply and fixing of M S Stand for Out door unit duly painted of approved color & suaitable for wall mounting i/c fastners etc, as per requirement of outdoor A.C. units of different capacity & as per approval of EIC, complete as reqd.
Supply and fixing of Voltage Stabilizer suitable for operation of 1.5 TYR Hot & Cold type Inver Split AC and the Voltage range should be 170-280 volts (model: VS 500, make: V Gaurd or similar).
Supply & installation of automatic stainless steel hand dryers with powder coated metal body with touch free infra red activation suitable for co-operation on 230 volt, 50 Hz, single phase AC supply with automatic operation along with sensor, timer control, over load protection etc. complete as required. Similar to Make:- Euronics, Model :EH21NW
Supply,Installation Testing Commissioning of water filter cum RO and UV purifier of 50 LPH capcity with TDS controller suitable for open well water and connection with existing water cooler i/c level controller having function of filter change alarm of audiable / visual type, auto start and auto off operation, protection from over voltage and over current etc. as required provided with pre filters etc as required. Make: ION Exchange,Kent , Hitech, Eureka Fobes or equivalent approved
Supply, Installation, Testing and Commissioning of storage type self contained drinking water coolers of 60 ltrs cooling capacity per hours with 80 ltr storage capacity (60/80 ltrs.) confirming to IS:1475-2001 with upto date amendments suitable for operation on 230 volts +/- 10%, 50 Hz, single phase AC supply. The tank and body casing shall be made out from stainless steel SS 304 grade with minimum thickenss 0.8 mm.Full width single sheet moulded drain tray to prevent water splash.Top cover insulated fitted with hinges,double gasket all side for avoid dust particles,insects contaminated in the tank. Led bottom sheet should be fitted in between tank and top cover. Compressor and condensing standing base made with heavy guage not less than 1.25 mm and food grade stainless steel to avoid rusting or demage the water coolers. The water cooler shall have 02 numbers faucets and shall confirm as per specification including incomer cable of suitable rating with 3 pin 15 Amp. plug top etc. complete as required.
Supply, Installation, Testing and Commissioning of storage type self contained drinking water coolers of 60 ltrs cooling capacity per hours with 80 ltr storage capacity (60/80 ltrs.) confirming to IS:1475-2001 with upto date amendments suitable for operation on 230 volts +/- 10%, 50 Hz, single phase AC supply. The tank and body casing shall be made out from stainless steel SS 304 grade with minimum thickenss 0.8 mm.Full width single sheet moulded drain tray to prevent water splash.Top cover insulated fitted with hinges,double gasket all side for avoid dust particles,insects contaminated in the tank. Led bottom sheet should be fitted in between tank and top cover. Compressor and condensing standing base made with heavy guage not less than 1.25 mm and food grade stainless steel to avoid rusting or demage the water coolers. The water cooler shall have 02 numbers faucets and shall confirm as per specification including incomer cable of suitable rating with 3 pin 15 Amp. plug top etc. complete as required.
SH- XI- Cold Storage facility
Outer Dimension of Cold Storage Room will be approximately 3.2M x 3.4M x 4.5M Products to be stored will be Plum, Cherries, Apple & Frozen like Meat. Desire Temperature to be achieved : The Cold Room temperature is to be maintained between -4°C to 0°C while the ambient temperature is 35°C. The Pull down time shall be 24 Hours. Digital Temperature Indicator Cum Controller will be provided by Tenderer. Insulation: The Wall & Ceiling Gasket PUF (Polyurethane Foam) Panel Shall be 120 mm thickness Cyclopentane PUF insulated Panels with PPGI (Pre-Painted Galvanized Iron Sheet) finish and thichkness should be 0.5 mm. The Anti-Skid floor will be of 60 mm thick floor panel with marine ply 12 mm with 1.2 mm Al. Chequer Sheet. . Flush Type Door 34” (W) x 78” (H) with 50% overlap PVC Strip Curtain & View Port (300 x 300 mm). Door safety facility from outside like Al. Kick Plate, light switch, Lock & Key, Door Closure, Safety knob & Safety Alarm etc. reputed make for door accessories Refrigeration Units: Refrigeration System for maintaining temperature in Cold Room, Capacity: 20,000 BTU/H x 2 Nos (1 Working 1 standby). As per specifications i/c copper piping, cabling and starter Installation, testing and commissioning refrigeration units as required for one of door opening approximately 10-20 times in day. The refrigerant will be CFC Free (R 404 a/ R 134a). Refrigeration System will be air-cooled type with power supply 430v, 3 Ph, 50 Hz operations along with all necessary associated accessories. Refrigeration System will be included Copper Piping, PVC wire, refrigerant etc between Indoor & Outdoor unit. PVC drain pipes to drain out the condensate from evaporator outlet to the nearest drain pit. Refrigerant piping, control cabling & drain piping up to 5 meters length is encluded in the scope of this item.
Outer Dimension of Cold Storage Room will be approximately 3.2M x 2.2M x 4.5M Products to be stored will be Raw Fish, Prawns Pharma, Cut Flowers, Pre-cut Vegetable. Desire Temperature to be achieved : The Cold Room temperature is to be maintained between 0°C to 10°C while the ambient temperature is 35°C. The Pull down time shall be 24 Hours. Digital Temperature Indicator Cum Controller will be provided by Tenderer. Insulation: The Wall & Ceiling Gasket PUF (Polyurethane Foam) Panel Shall be 60 mm thickness Cyclopentane PUF insulated Panels with PPGI (Pre-Painted Galvanized Iron Sheet) finish and thichkness should be 0.5 mm.. The Anti-Skid floor will be of 60 mm thick floor panel with marine ply 12 mm with 1.2 mm Al. Chequer Sheet. Flush Type Door 34” (W) x 78” (H) with 50% overlap PVC Strip Curtain & View Port (300 x 300 mm). Door safety facility from outside like Al. Kick Plate, light switch, Lock & Key, Door Closure, Safety knob & Safety Alarm etc. reputed make for door accessories. Refrigeration Units: Refrigeration System for maintaining temperature in Cold Room, Capacity: 15,000 BTU/H x 2 Nos (1 Working 1 standby). As per specifications i/c copper piping, cabling and starter Installation, testing and commissioning refrigeration units as required for one of door opening approximately 10-20 times in day. The refrigerant will be CFC Free (R 404 a/ R 134a). Refrigeration System will be air-cooled type with power supply 430v, 3 Ph, 50 Hz operations along with all necessary associated accessories. Refrigeration System will be included Copper Piping, PVC wire, refrigerant etc between Indoor & Outdoor unit. PVC drain pipes to drain out the condensate from evaporator outlet to the nearest drain pit. Refrigerant piping, control cabling & drain piping up to 5 meters length is encluded in the scope of this item.
Outer Dimension of Cold Storage Room will be approximately 3.2M x 2.8M x 4.5M Products to be stored will be Pre-cut Vegetable Desire Temperature to be achieved : The Cold Room temperature is to be maintained between 0°C to 10°C while the ambient temperature is 35°C. The Pull down time shall be 24 Hours. Digital Temperature Indicator Cum Controller will be provided by Tenderer. Insulation: The Wall & Ceiling Gasket PUF (Polyurethane Foam) Panel Shall be 60 mm thickness Cyclopentane PUF insulated Panels with PPGI (Pre-Painted Galvanized Iron Sheet) finish and thichkness should be 0.5 mm.. The Anti-Skid floor will be of 60 mm thick floor panel with marine ply 12 mm with 1.2 mm Al. Chequer Sheet. Flush Type Door 34” (W) x 78” (H) with 50% overlap PVC Strip Curtain & View Port (300 x 300 mm). Door safety facility from outside like Al. Kick Plate, light switch, Lock & Key, Door Closure, Safety knob & Safety Alarm etc. reputed make for door accessories. Refrigeration Units: Refrigeration System for maintaining temperature in Cold Room, Capacity: 15,000 BTU/H x 2 Nos (1 Working 1 standby). As per specifications i/c copper piping, cabling and starter Installation, testing and commissioning refrigeration units as required for one of door opening approximately 10-20 times in day. The refrigerant will be CFC Free (R 404 a/ R 134a). Refrigeration System will be air-cooled type with power supply 430v, 3 Ph, 50 Hz operations along with all necessary associated accessories. Refrigeration System will be included Copper Piping, PVC wire, refrigerant etc between Indoor & Outdoor unit. PVC drain pipes to drain out the condensate from evaporator outlet to the nearest drain pit. Refrigerant piping, control cabling & drain piping up to 5 meters length is encluded in the scope of this item.
Outer Dimension of Cold Storage Room will be approximately 3.2M x 2.8M x 4.5M Products to be stored will be Raw Fish, Prawns Pharma Desire Temperature to be achieved : The Cold Room temperature is to be maintained between 0°C to 10°C while the ambient temperature is 35°C. The Pull down time shall be 24 Hours. Digital Temperature Indicator Cum Controller will be provided by Tenderer. Insulation: The Wall & Ceiling Gasket PUF (Polyurethane Foam) Panel Shall be 60 mm thickness Cyclopentane PUF insulated Panels with PPGI (Pre-Painted Galvanized Iron Sheet) finish and thichkness should be 0.5 mm.. The Anti-Skid floor will be of 60 mm thick floor panel with marine ply 12 mm with 1.2 mm Al. Chequer Sheet. Flush Type Door 34” (W) x 78” (H) with 50% overlap PVC Strip Curtain & View Port (300 x 300 mm). Door safety facility from outside like Al. Kick Plate, light switch, Lock & Key, Door Closure, Safety knob & Safety Alarm etc. reputed make for door accessories. Refrigeration Units: Refrigeration System for maintaining temperature in Cold Room, Capacity: 15,000 BTU/H x 2 Nos (1 Working 1 standby). As per specifications i/c copper piping, cabling and starter Installation, testing and commissioning refrigeration units as required for one of door opening approximately 10-20 times in day. The refrigerant will be CFC Free (R 404 a/ R 134a). Refrigeration System will be air-cooled type with power supply 430v, 3 Ph, 50 Hz operations along with all necessary associated accessories. Refrigeration System will be included Copper Piping, PVC wire, refrigerant etc between Indoor & Outdoor unit. PVC drain pipes to drain out the condensate from evaporator outlet to the nearest drain pit. Refrigerant piping, control cabling & drain piping up to 5 meters length is encluded in the scope of this item.
Supplying and Fixing of extra refrigerant piping along with control cable beyond 5 meters against above mentioned items (1 to 4) complete with refrigerant pipe insulation etc.as required
JCC ENGINEERS PRIVATE LIMITED
HLK Infrastructure Pvt Ltd
CIS GLOBAL INFRATECH PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .