| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹47.0 L+₹14.0 L (42.3%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹50.3 L+₹17.3 L (52.3%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹52.7 L+₹19.6 L (59.4%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹53.8 L+₹20.7 L (62.8%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
16 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744 103
REPAIR / MAINT AND REPLACEMENT OF LT DISTRIBUTION SYSTEM AND OTHER CONNECTED FITTING FIXTURE ETC AT OTM ACCN UNDER AGE E/M-I MINNIE BAY AT GE MINNIE BAY, PORTBLAIR
2023_MES_596911_1
8243/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MINNIEBAY PORT BLAIR
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE Minniebay
₹71,000
Yes
25 Jul 2023
19 May 2023
19 Jun 2023
20 May 2023
16 Jun 2023
3 Jun 2023
Amount
M& L for preparation of internal and external old steel surface of LT Feeder Pillar Box/ Panel Boards of various size and completely removal of existing treatment by scraping and chemical treatment and surface painted with DUCO paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
M& L as in repair of fabrication for LT Feeder Pillar Box/ Panel Boards made out of 2.00 mm thick mild steel sheet fixed to existing frame and painted with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing worn out shutter frame and fixed with minimum two hinges to existing frame complete all as specified and directed.
M& L as in repair of fabrication for LT Feeder Pillar Box/ Panel Boards made out of 3.00 mm thick mild steel sheet fixed to existing frame and painted with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing worn out shutter frame and fixed with minimum two MS hinges to existing frame complete all as specified and directed.
Supply and fix as in repair hot dipped galvanized tower bolts, 300mm long bright bolt including connected accessories fixed on front and rear side of the doors for locking LT FP Boxes complete all as specified and as directed by Engineer-in-Charge.
M&L for aligning of incoming and outgoing lines/cables of electrical distribution panel/feeder panel box cleaning vegetation for around 1.5m radius checking all electrical connection renewing minor unserviceable parts and fixing insulation tape above bare conductors complete all as specified and directed by Engineer-in-charge.
Material and labour as repairs of doors hinges of LT feeder pillar/Panel box complete with welding complete all as specified and as directed by Engineer-in-Charge.
Demolition of PCC any grade complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain Cement Concrete of (1:4:8) Nominal mix of D2 grade with using 40 mm aggregate as in foundations filling and mass concrete including formwork complete all as specified and as directed by Engr-in-Charge.
Material and labour Plain Cement Concrete (1:3:6) Nominal mix type C-2 (using 40 mm graded broken stone aggregate) as in coping/collar of poles including necessary form work complete all as specified and as directed by Engr-in-Charge.
Taking down of MCCB of any size complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 630 Amps,TPN/ 4 pole, 415 volt, breaking capacity 36 KA, Ics = Icu = 100%, Icw - 3 Sec conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 400 Amps,TPN/ 4 pole, 415 volt, breaking capacity 36 KA Ics = Icu = 100%, Icw - 3 Sec conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 250Amps,TPN/ 4 pole, 415 volt, breaking capacity 25 KA Ics = Icu = 100%, Icw - 3 Sec conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 200Amps,TPN/ 4 pole, 415 volt, breaking capacity 25 KA Ics = Icu = 100%, Icw - 3 Sec conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 160 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA, Ics = Icu = 100%, Icw - 3 Sec conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 100 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA , Ics = Icu = 100%, Icw - 3 Sec conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 63 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA, Ics = Icu = 100%, Icw - 3 Sec conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Taking down of Change Over Switch of any size complete all as specified and as directed by Engineer-in-Charge.
S & F on load change over switch 4 pole 63 Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge
S & F on load change over switch 4 pole 250 Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge
S & F on load change over switch 4 pole 400 Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair for aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables complete all as specified and directed :-
Supply and fix in repair for Copper cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge and for the following sizes of cables :-
Supply and fix as in repair of Cable gland of LT UG cables in panels for complete all as specified and as directed by Engineer-in-Charge and the following sizes of LT UG cables :-
Taking Down of Old rusted feeder pillar Box complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing of LT panel box vermin proof dust proof IP-54 double door of suitable size for 3 phase 415 Volts of CPRI approved out door made out of 3.15mm thick CRCA sheet one side of MCCB is incoming and other side is outgoing , every MCCB has spade link, Cable entry of 300mm size in 4 nos , MCCB compartment should be minimum 450X450 mm ,with angle iron frame of size 50X50X 6mm cubical type including 300 mm panel stand made out of angle iron size 50 X50X 6mm of complete including necessary Plain Cement Concrete along with formwork and foundation as per site requirement to accommodated to the following:- (a) MCCB 4 pole 630Amps breaking capacity 36 kA - 1 Nos (b) Multifunction Meter (V,I,PF) with CT's - 01 Nos (c) LED indicating lamp (R-Y-B) - 18 Nos (d) MCCB 4 pole 400 Amps breaking capacity 36 kA- 02 Nos (e) MCCB 4 pole 250 Amp breaking capacity 25 KA - 02 Nos (f) MCCB 4 pole 100 Amp breaking capacity 25 KA - 01 Nos Note : 1. MCCB should be Ics=100% Icu =Icw - 3 Sec 2. Test Certificate should be submit for all the MCCBs incorporated in this item.
Taking down of unserviceable Multi Functional Meter and Supply and fixing new meter (V,A,PF, W) with CTs including necessary fabrication required and painting the effected area with existing paint complete all as specified and as directed by Engineer-in-Charge.
Taking down of unserviceable old UG Cable of any size and any type on walls/passes through pipe complete all as specified and directed .
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: The rate quoted is inclusive of Cable lugs, Cable Gland and joint kit (if required).Earthwork required under this item shall be measured and paid under relevant items.
4 Core 6 Sqmm
2 Core 10 Sqmm
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 Core 120 Sqmm
3.5 Core 185 Sqmm
3.5 Core 240 Sqmm
3.5 Core 300 Sqmm
3.5 Core 400 Sqmm
Relaying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade, laid in trenches / duct with saddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 10 Sqmm to 35 Sq mm Core complete all as specified and as directed by Engineer-in-Charge. Note : Earthwork required under this item shall deemed to be included in this quoted rate.
Relaying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade, laid in trenches / duct with saddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 50 Sqmm 3.5 to 95 Sq mm 3.5 Core core complete all as specified and as directed by Engineer-in-Charge. Note : Earthwork required under this item shall deemed to be included in this quoted rate.
Relaying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade, laid in trenches / duct with saddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 120 Sqmm 3.5 Core to 240 Sq mm 3.5 Core complete all as specified and as directed by Engineer-in-Charge. Note : Earthwork required under this item shall deemed to be included in this quoted rate.
Relaying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade, laid in trenches / duct with saddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 300 Sqmm 3.5 Core to 400 Sq mm 3.5 Core complete all as specified and as directed by Engineer-in-Charge. Note : Earthwork required under this item shall deemed to be included in this quoted rate.
Taking down of unserviceable old DWC HDPE Pipe of any size and any type complete all as specified and as directed by Engineer-in-Charge
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge.
Taking down of old GI /PVC Pipe complete all as specified and as directed by Engineer-in -charge.
S&F GI pipe of medium grade 40 mm dia ISI marked all fitting fixture for fixing with wall and road crossing etc. complete all as specified and as directed by Engineer-in-Charge
S&FGI pipe of medium grade 63 mm dia ISI marked all fitting fixture for fixing with wall and road crossing etc.complete all as specified and as directed by Engineer-in-Charge
S&FGI pipe of medium grade 80 mm dia ISI marked including all fitting fixture for fixing with wall and road crossing complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5m wide and not exc 1.5m in depth for foundation, pipe, laying of cable etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out complete all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
M&L for road cutting, removing of material , returning filling and pcc 1:2:4 for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe all as specified and as directed by Engineer-in -charge.
M&L for fault finding of LT UG Cable including excavation , returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe complete all as specified and as directed by Engineer-in -charge. Note:- LT UG Cable, Straight through joint kit and DWC (Double Wall corrugated) HDPE pipe measured and paid separately.
Taking down of old unserviceable Joint Kit complete all as specified and as directed by Engineer-in -charge.
S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 185 to 240 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in -charge.
S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 300 to 400 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in -charge.
Rerouting and re-aligning the serviceable alluminium Power Cable on wall /cable duct of size 16 to 50 Sqmm with saddler of with aluminium pati with required size of screw inside cable duct complete all as directed.
Rerouting and re-aligning the serviceable alluminium Power Cable on wall /cable duct of size 70 to 185 Sqmm with saddler of with aluminium pati with required size of screw inside cable duct complete all as directed.
Taking Down of old unserviceable Junction box of any type and any size complete all as specified and as directed by Engineer-in -charge.
Supply & fixing IP 66 thermoplastic-polycarbonate cable junction box of size 205X255X112 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI clamp of required size / self drill screw ,one no of MCB SP 6 Amp and four way Connector complete all as specified and as directed by Engineer-in -charge.
Supply & fixing IP-66 thermoplastic-polycarbonate cable junction box of size 155X210X92 with terminal suitable for 10 to 16 Sqmm ,which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of required size / self drill screw one No of MCB SP 06 A and four way 32 Amp Connector complete all as specified and as directed by Engineer-in -charge.
Supply & fixing IP-66/ 67 thermoplastic-polycarbonate cable junction box of size 130X180X77 with terminal suitable for 4 to 10 Sqmm which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of required size / self drill screw with one No of MCB SP 06 A and four way Connector complete all as specified and as directed by Engineer-in -charge.
Taking Down of old unserviceable earthing complete all as specified and as directed by Engineer-in -charge.
M&L as in repair of Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3 mm thick, buried directly in ground earth pit not less than 2.25 metre below normal ground level with top edge of the plate not less than 1.5 mtr below ground level, connected to and including copper earth strip 25 x 3.00 mm by means of copper brazing and steel bolts, nuts, check nuts and washers protected with 40mm bore GI pipe light grade and 20 mm dia GI pipe for watering and earth pit surrounded by packed layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board and testing on completion including PCC (1:3:6) type C-2, using 20mm graded stone aggregate as in earthing pit with RCC cover and framing including necessary earth work etc, complete all as specified and as directed by Engineer-in -charge. Note: (i) Cost of Copper earth Strip and GI protection pipe up to 7.5m length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point (iii) Copper Material should be molecularly 99.99%
S&F in repairs of LT cable route marker is made using iron and round in shape and which is 100 mm dia (4 inch) and thickness is 10 mm and it is attached to MS square bar 60 cm long of size 12 mm, fixing above UG cable below ground 200 mm including PCC and earth work complete all as specified and as directed by Engiener-in-Charge.
Material and labour as in repair for Earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Square Bar embedded in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 25X30X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with Black letters on background and complete all as specified and as directed by Engineer-in -charge.
Taking down Earth pit cover of conventional earthing and S&F PCC earthing pit of outer size 450X450 X300 MM and inner Size 350X350X 300 RCC pit cover of required size with handle arrangement including necessary earth work complete all as specified and as directed by Engineer-in -charge.
Material and labour Painting to Steel tubular / RCC poles 9 m long with one coat of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level / copping remaining Job portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc. Complete all as specified and as directed by Engineer-in -charge.
Dismantling carefully and taking down existing street light fitting of any type from the street light poles of any height along with GI bracket ,clamps, bolts,& nuts etc. complete all as specified and as directed by Engineer-in -charge.
Dismantling the existing old rusted /unserviceable Steel / RCC pole of any type including all fitting fixture complete all as specified and as directed by Engineer-in -charge.
M&L for GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws, with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9m including necessary Earth work,PCC foundation copping etc. and refixing of all existing fitting fixture exist in old electric pole complete all as specified and as directed by Engineer-in -charge.
Supply and laying in repairs 2.5 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt FRLSH grade twin core cable drawn through CPVC Pipe not less than 20 mm dia for connecting the street light fittings including alluminium clamp complete all as specified and as directed by Engineer-in -charge.
Supply and fix GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.2m long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed by Engineer-in -charge.
S&F in replacement energy efficient street light luminaire LED type 90 watts,IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed by Engineer-in -charge.
S&F in replacement energy efficient street light luminaire LED type 72 watts,IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed by Engineer-in -charge.
M&L for servicing of air circuit breaker rating 1250-1600 Amps ,dismantling from the panel by taking out the defective moving contact unit with fingers and its connected accessories , dismantling and servicing the defective moving contact with fingers ( 3nos ), under voltage trip ( 1 no ) , shunt release trip ( 1 no ), assembling and fixing back in to the panel and locking properly and testing on load all as specified by Engineer-in-charge
S&F in repair energy efficient solar street light all in one with lithium battery LED type of 30 watts,120 Lm/W and IP 65 protection in built motion sensor colour temp 6500 complete all as specified and as directed by Engineer-in -charge. Make - Model No LSTSOL30N of Luker or equivalent makes in list of makes
S&F in repairs under voltage relay 415 V AC suitable for LT ACB breaker 1250 Amps connecting and testing all as specified and directed by Engineer-in-charge
S&F in repairs microprocessor based trip relay with display 415 V AC suitable for LT ACB breaker 1250 Amps connecting and testing all as specified and directed by Engineer-in-charge
Taking out old unserviceable Service wire and supply and fixing submersible wire copper Conductor Weather Proof 6 Sqmm three core complete all as specified and as directed by Engineer-in -charge.
Taking out old unserviceable Service wire and supply and fixing submersible wire copper Conductor Weather Proof 10 Sqmm three core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair rubber insulation tape 25 cm width 2.5 Mtr long fixing of connection make water proof outside the Electrical equipments and also fixing the underground cable where crack arises outside complete all as specified and as directed by Engineer-in -charge.
Supply and fix in replacement LED Bollard light fittings 10watts made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete all as specified and as directed by Engineer-in -charge. Cat No :- LBSL1 -10- CDL of Crompton Greaves or equivalent makes in list of makes
Supply& Fixing in replacement of LED post top lantern gate lights of 35Watt capacity including LED Warm lights with modern look using new generation technology in LED suitable for pole of dia of existing sizes complete all as specified and directed by Engineer-in-Charge. Note : a) Necessary fixing arrangements like grouting, foundation and coping required for fixing of Post top lantern shall deemed to be included in quoted rates.
Supply& Fixing in replacement of LED post top lantern gate lights of 40Watt capacity including LED Warm lights with modern look using new generation technology in LED suitable for pole of dia of existing sizes complete all as specified and directed by Engineer-in-Charge. Note : a) Necessary fixing arrangements like grouting, foundation and coping required for fixing of Post top lantern shall deemed to be included in quoted rates.
Supply and laying broken stone or aggregate of Gauge not exc. 40 mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a true Surface, complete all as specified and as directed by Engineer-in -charge.
Material and labour for cross arms, bracing, supports, clamps and back plate fabricated from structural MS section for gate including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of complete all as specified and as directed by Engineer-in -charge.
M & L as in repair of danger notice plate of PVC sheet, vitreous enamelled white, with letters, figures ( English, Hindhi,Tamil) and conventional skull and bones in signal red colour and fixed with Alluminium Clamp. clamps, bolts and nuts of approved size, for HT of voltage 11000 Volts, 25x20cm size all as directed.
M & L for as in repair of danger notice plate of PVC sheet, vitreous enamelled white, with letters, figures ( English, Hindhi,Tamil) and conventional skull and bones in signal red colour and fixed with Alluminium clamps, bolts and nuts of approved size, for LT voltage 415 V, 25x20cm size all as directed.
M&L as in repair for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground vertically to a depth of not less than 2.25m below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete all as specified and as directed by Engineer-in -charge. NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL (ii) If the desired earth resistance is not achieve during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible.(iii) Cost of GI strip and GI protection pipe up to 7.5 mtr shall be included in the quoted rate
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge.
Supply and fixing in repair for GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge.
Supply and fixing in repair for Aluminium earth continuity conductor or main earthing lead fixed to wall above 11m or roof top of 3rd floor or recess or any other indicated situation for loop earthing etc. as required for 25 mm x 3mm thick, alluminium using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge. Note:- Necessary scaffolding and other arrangement to be no extra cost and all safety precaution to be taken by the contractor.
Refixing for Aluminium earth continuity conductor or main earthing lead fixed to wall of height up to 16m rooftop of 3rd floor or any other indicated as required for 25 mm x 3mm thick, alluminium strip using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge. Note:- Necessary scaffolding and other arrangement to be no extra cost and all safety precaution to be taken by the contractor.
M&L for welding of two MS/GI Sheet / Pipes on site including grinding the welded portion and made smooth surface complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair MCB 63 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs MCB 100 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA complete all as specified and as directed by Engineer-in-Charge.
M&L for cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete all as specified and directed
Taking Down of Old unserviceable Bus Bar of any size complete all as specified and directed by Engineer-in -charge.
Supply and fixing of Aluminium Bus Bar of existing Size in the existing panel board on site on required shape post insulators, complete all as specified and as directed by Engineer-in -charge.
Supply and fixing in repair LED Indicating lamp (R-Y-B) complete all as specified and as directed by Engineer-in -charge.
M/s Karbhagam Sales Agency
SKY GROUP
DHAKSHNA MOORTHY AND SON
Tropical Refrigeration
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .