| 1 | L1₹6.6 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.2 L+₹46,865 (6.96%)Rejected-Finance E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹7.2 L+₹50,198 (7.45%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹7.7 L+₹98,780 (14.7%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹8.6 L+₹1.9 L (28.1%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
19 Oct 2022, 6:00 pmClosed
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE THANJAVUR
REPAIRS AND SERVICING OF UNSERVICEABLE PARTS TO COOLING APPLIANCES AND ALLIED SERVICES AT AFS THANJAVUR
2022_MES_553526_1
8905/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
THANJAVUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AIRFORCE THANJAVUR
₹16,000
Yes
14 Nov 2022
21 Sept 2022
20 Oct 2022
21 Sept 2022
19 Oct 2022
5 Oct 2022
Amount
S&F MCB, Single pole, 6 to 32amps, 240volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20amps capacity complete all as specified and as directed.
S&F in replacement metal clad plug two pin and earth complete all as specified and directed.
M&L for sub main wiring with 2 run of 4sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100v grade with stranded copper conductor including one run of 2.5sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed.
Taking down and supply and fix new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (M-22 / F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for the following sizes of cooling appliances of make SHRIRAM/KIRLOSKAR/CARRIER/VOLTAS complete all as specified and as directed.
1.5 - 2.0TR capacity split type Air conditoner
Refrigerator 180 to 310 ltrs capacity.
Deep freezer for 200 to 320 ltrs capacity.
Water cooler 80 / 40 capacity. Note for Sl item No 05 to 08:- Rate quoted shall be deemed to be inclusive of filling / Gas charging.
Voltage Stabilizer 5 KVA capacity
Voltage Stabilizer 3 / 4 KVA capacity
Voltage Stabilizer 01 KVA capacity
S&F in replacement PCB (Printed circuit board) suitable for 1.5 / 2.0Ton of split type type Air conditioners all as specified and as directed.
M&L for Leak test with Co2 / Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R- 410 / R-22 for AC capacity 1.5 / 2TR Split type Air conditioner.
M&L for Leak test with Co2 / Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R-12 / R-134 for following cooling appliances.
Refrigerator
Water Cooler
Deep freezer
S&F Rigid PVC flexible hose of 15mm dia 2.5mtr length with all acessories fixed on wall / ceiling / roof etc with suitable GI saddles and screws for connect with split type AC / water cooler as drain pipe complite all as per specified and asdirected.
S&F motor starter, 25A, 2 module for AC including madular metal flush box with suitable screws for housing the starter all as specified and directed.
Supply and replace with new fan leaf unit suitable for Airconditioner of capacity 1.5TR / 2TR all as per specified and as directed.
Supply and replace with new remote control unit suitable for Airconditioner all as per specified and directed.
Supply and replace with new condenser coil unit made of copper suitable for the following sizes of split Airconditioner all as per specified and directed.
1.5 ton capacity
2.0 ton capacity
S&F in repair starting capacitors for following cooling appliances.
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
S&F in repair Running capacitors for following cooling appliances
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
S&F in repair Thermostatic switch for following cooling appliances.
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
S&F in repair Fan Motor for following cooling appliances.
Split type Air Conditioner (Outdoor)
Refrigerator
Deep Freezer
Water Cooler
S&F in repair indoor unit blower Fan Motor for 1.5 / 2 Ton Split type Air conditioner.
S&F in replacement suction valve 1.5 / 2 TR capacity.
S&F in replacement discharge valve 1.5 / 2 TR capacity.
S&F in replacement flare nut of size 5 / 8 inch.
S&F in replacement flare nut of size 1 / 2 inch.
S&F in replacement flare nut of size 1 / 4 inch.
S&F in replacement flare nut of size 3 / 8 inch.
S&F in replacement mounting stand for split AC 1.5 / 2TR capacity.
S&F in replacement PCB (Printed circuit board) suitable for Indoor 1.5 / 2.0TR Inverter split type Air conditioners all as specified and as directed.
S&F in replacement PCB (Printed circuit board) suitable for outdoor 1.5 / 2.0TR Inverter split type Air conditioners all as specified and as directed.
S&F in replacement PCB (Printed circuit board) suitable for refrigerator any type any size all as specified and as directed.
S&F in replacement indoor evaparator unit 1.5 / 2TR split AC complete all as specified and as directed.
S&F in replacement Outdoor condensing unit 1.5 / 2TR split AC complete all as specified and as directed.
S&F in replacement voltage stabilizer 4KVA range 170 to 260 Volts, output voltage 230volts AC supply 50HZ having low and high voltage protection, intelligent time delay system, wall mounting type including mounting accessories time delay 180 seconds +/- 20 seconds as initial time delay complete all as specified and as directed.
M&L for servicing / maintenance of water purifier by replacing unserviceable spares such as filters, UV lamps and power circuit boards(PCB) complete and make the unit in serviceable condition to the entire satisfaction complete all as specified and as directed.
Routine repair and annual maintenance of best water doctor of tank capacity 35 / 50ltrs installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed. Notes:- (a) The contractor shall make AMC contract with the authorised service agency of best water doctor / cooler and repair / maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water doctor / cooler noticed during the period 8 months.
Removing the window / split type AC upto 1.5 / 2 ton capacity of any make from any location for carrying out servicing complete as and when ordered and installing back at original location, testing and commissioning complete all as specified and as directed. Note :- The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower. c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary. d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, materials & labour, tools and plants, and back in on final position complete.
S&F PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and as directed.
M&L for shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed. (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc on walls. (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs.
Supply and fix in replacement copper tube for Split Acs of size 1/4 inch complete all as specified and as directed
Supply and fix in replacement copper tube for Split Acs of size 1/2 inch complete all as specified and as directed
UNIQUE INDIA CONSTRUCTIONS
Rajapriyaconstruction
BKR Enterprises
RK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .