| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹52.0 L+₹1.6 L (3.14%)Rejected-Finance 96 SHASTRI NAGAR SHASTRI NAGAR JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical Not approved due to two class below for eligible class |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
1 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JAIPUR
HQ CWE JAIPUR KALYAN MARG
COMPREHENSIVE MAINT OF B/R AND E/M ITEMS IN CERTAIN MD ACCN IN PRATAP ENCLAVE AND HAMID VIHAR UNDER ZONE I AREA AT JAIPUR MIL STN
2021_MES_419474_1
CWE/82058/JPR/E8
Open Tender
Civil Works
Item Rate
120 days
JAIPUR
Enlisted with MES in Class C and above and category a(i)
6 documents required · 6 mandatory
₹1,000
Yes
GE JAIPUR
₹1.1 L
Yes
13 Mar 2021
5 Feb 2021
3 Mar 2021
5 Feb 2021
1 Mar 2021
15 Feb 2021
60 days
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/ brick surfaces/ceiling etc. including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiling to store and rubbish off the premises etc complete all as specified and directed.
M&L for rendering 15mm thick on brick masonry on fair face of brick surfaces of brick work masonry on wall CM (1:4) on walls finished even and fair without using extra cement etc complete all as specified and directed.
M&L rendering 15mm thick on stone masonry surfaces or surface other than fair faces of brick work on wall in CM (1:6) finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:3) on ceiling finished even and fair without using extra cement etc complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 kg of cement per sqm etc complete all as specified and directed.
M&L for 5mm to 7mm thick screed bed of chemical adhesive of approved make for laying floor finishes i.e floor tiles etc complete all as specified and as directed.
M&L non skid ceramic tiles (coloured) 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including providing 15mm thick screed bed in CM (1:6) etc .complete all as specified and directed.
M&L for non skid coloured ceramic matching tiles 8 to 9.5mm thick (square / rectangular) (matt finish)area of each tiles exceeding 0.18 sqm but not exceeding 0.36 Sqm in floor etc using approved chemical mortar adhesive to match with coloured tiles etc complete all as specified and directed. Note : Adhesive shall be measured & paid separately
M&L for light shade full body vitrified matching tiles 8 to 9.5mm thick (square / rectangular) area of each tile not exceeding 0.36 sqm in floor etc using approved chemical mortar adhesive to match with coloured tiles etc complete all as specified and directed. Note : Adhesive shall be measured & paid separately
M&L for light shade full body vitrified matching tiles 8 to 9.5mm thick (square / rectangular) area of each tile not exceeding 0.36 sqm in skirting, dado etc set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles and including providing 10mm thick back coat in CM (1:4) etc complete all as specified and directed.
S&F coloured glazed ceramic tiles vertical surfaces first quality of size (300x600)mm, 7 to 8 mm thick (digital tiles) , in skirting, dado etc laid in concept/pattern using highlighters set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles and including providing 10mm thick back coat in CM (1:4) etc complete all as specified and directed.
M&L of 15 to 16mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and rounding the edges etc complete all as specified and directed.
M&L of 12mm thick marble slab as in cooking platforms as base to granite top placed on vertical marble partitions fixed with approved adhesive etc complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed.
S&F 18 mm thick HDWPC (High density wooden plastic composite) kitchen cupboard/door shutter board, one side colour/white laminate and other side decorative as in modular kitchen/ cabinets fixed with minifix hardware where ever required including edge band 22 mm wide 0.80 m thick of matching colour on exposed surfaces of board fixed with polymaster adhesive including trimming edges of edge band to true line of thickness of board by manual trimmer, fixed to wall etc complete all as specified and directed. Make: Pearlwood or equivalent in Rajshri plastiwood /Greenply/Century plywood.
S&F 8 mm thick HDWPC (High density wooden plastic composite) board of both side white laminate as in back kitchen and other side un decorative as in back of kitchen cabinets/partition of cupboard etc complete all as specified and directed. Make: Pearlwood or equivalent in Rajshri plastiwood /Greenply/Century plywood.
S&F kitchen plain baskets of stainless steel size 42.5cmx50cmx10cm of grade SS-304 etc complete all as specified & directed. Make : Godrej/ Hindware/Lifetime
S&F kitchen perforated cutlery baskets of stainless steel size 42.5cmx50cmx10cm of grade SS-304 etc complete all as specified & directed. Make : Godrej/Hindware/Lifetime
S&F kitchen cup & saucer baskets of stainless steel size 42.5cmx50cmx10cm of grade SS-304 etc complete all as specified & directed. Make : Godrej/Hindware/Lifetime
S&F kitchen plate baskets of stainless steel size 42.5cmx50cmx15cm of grade SS-304 etc complete all as specified & directed. Make : Godrej/Hindware/Lifetime
S&F kitchen grain baskets of stainless steel size 42.5cmx50cmx25cm of grade SS-304 etc complete all as specified & directed. Make : Godrej/Hindware/Lifetime
S&F stainless steel basket guide channels suitable for running basket as mentioned in above item of grade SS-304 etc complete all as specified & directed. Make: Hettich or equivalent in Godrej/Hindware/Lifetime
S&F stainless steel handles of size 100 mm fancy type of approved make etc complete all as specified & directed.
S&F in repair kitchen sinks made of stainless steel sheet 1mm thick of grade SS-304 including washer, brass sink coupling, waste pipe, bowl size 495 x 420 x160 mm fixed in kitchen granite top including cutting granite/ marble of cooking platform etc complete all as specified & directed.
S&F stainless steel sink with draining board, made out of 1mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x330mm x160mm etc complete all as specified & directed.
Taking up or down steel tubing and connections including cleaning for re-fixing or removal to store. bore of pipe in 15mm etc complete all as specified & directed.
Taking up or down steel tubing and connections including cleaning for re-fixing or removal to store. bore of pipe in 20mm etc complete all as specified & directed.
Taking up or down steel tubing and connections including cleaning for re-fixing or removal to store. bore of pipe in 25mm etc complete all as specified & directed.
S&F for 15 mm GI tubing medium grade with all fitting and fixed to walls of concealed or fitted to ceiling or laid in under floor etc complete all as specified & directed.
S&F for 20 mm GI tubing medium grade with all fitting and fixed to walls of concealed or fitted to ceiling or laid in under floor etc complete all as specified & directed.
S&F for 25 mm GI tubing medium grade with all fitting and fixed to walls of concealed or fitted to ceiling or laid in under floor etc complete all as specified & directed.
S&F in repair bib taps 15mm bore cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union etc complete all as specified & directed. Make: Jaguar Cat Part No KUP-CHR-35037PM or equivalent as mentioned in Appx ‘B’
S&F in repair bib taps 15mm bore 2-in-1 cast cooper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union etc complete all as specified and directed. Make: Jaguar Cat Part No KUP-CHR-35041PM or equivalent as mentioned in Appx ‘B’
S&F in repair kitchen mixer 15mm bore cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union for kitchen etc complete all as specified and directed. Make: Jaguar Cat Part No FLR-CHR-5309N or equivalent as mentioned in Appx ‘B’
S&F in repair sink cock 15mm bore cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union etc complete all as specified and directed. Make: Jaguar Cat Part No FLR-CHR-5347N or equivalent as mentioned in Appx ‘B’
S&F in repair WHB mixer single lever 15mm bore swan neck cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union etc complete all as specified and directed. Make: Jaguar Cat Part No KUP-CHR-35011BPM or equivalent as mentioned in Appx ‘B’
S&F in repair brass CP towel rail 60 cm long square etc complete all as specified and directed. Make: Jaguar Cat Part No AKP-CHR-35711PS or equivalent as mentioned in Appx ‘B’
S&F SS towel ring square including Chromium plated brass screws & plastic rawl plug etc complete all as specified and directed. Make: Jaguar Cat Part No AKP-CHR-35721P or equivalent as mentioned in Appx ‘B’
S&F Soap dish, CP brass square fixed to plugs with chromium plated brass screws etc complete all as specified and directed. Make: Jaguar Cat Part No AKP-CHR-35731P or equivalent as mentioned in Appx ‘B’
S&F in repair Brass chromium plated shower rose 150mm x 150 mm size with or without swivel joints, any size, including fixing to steel pipe or union etc complete all as specified and directed. Make: Jaguar Cat Part No OHS-CHR-1605 or equivalent as mentioned in Appx ‘B’
S&F in repair brass chromium plated shower arm 15mm size, including fixing to steel pipe or union etc complete all as specified and directed.
S&F in repair brass CP water Bathtub Spout with Wall Flange 15mm bore etc complete all as specified and directed. Make: Jaguar Cat Part No SPJ-CHR-35429PM or equivalent as mentioned in Appx ‘B’
S&F in repair 15 mm dia Angle valve, cast copper alloy chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed etc complete all as specified and directed. Make: Jaguar Cat Part No KUP-CHR-35053PM or equivalent as mentioned in Appx ‘B’
S&F in repairs, PTMT alloy bathroom cabinet with mirror of overall size 300mm x 450mm etc complete all as specified and directed.
S&F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm etc complete all as specified and directed.
S&F in repair 15mm bore gate valve gun metal screwed down high pressure with iron wheel head screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repair 20mm bore gate valve gun metal screwed down high pressure with iron wheel head screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repair 25mm bore gate valve gun metal screwed down high pressure with iron wheel head screwed both ends for iron pipe or for union complete all as specified and directed.
S&F wall mixer brass hot & cold, 15mm bore (Concealed body Diverter complete ) with connection to overhead shower, bright finish ,screwed the ends for iron pipe and plugging etc complete all as specified and directed. Make: Jaguar Cat Part No ALD-CHR-079N or equivalent as mentioned in Appx ‘B’
S&F concealed brass CP single lever diverter exposed etc complete all as specified and directed. Make: Jaguar Cat Part No KUP-CHR-35079 KPM or equivalent as mentioned in Appx ‘B’
S&F corner glass self large 300mmx300mm etc complete all as specified & directed.
S&F in repairs vitreous china squatting pan, `Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including providing connection and lime concrete bedding to making good to floor etc complete all as specified & directed.
S&F in repairs PVC valve less, symphonic action type flushing cistern 10 litres capacity, low level, white, with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC,32mm dia suitable for low level cistern etc complete all as specified & directed.
S&F vitreous China white single piece WC (European type) including inbuilt vitreous china cistern size (360X640X680)mm strap 220mm etc complete all as specified and directed. Make: Jaguar Cat Part No SLS-WHT-6853S or equivalent as mentioned in Appx ‘B’
Demolition of old existing unserviceable EWC seat including providing supply and fixing vitreous china wash down water closet pan (pedestal pattern) white including connections to drain ( or outgoing pipe) and to flushing pipe anti sypohonage pipe etc & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device etc complete all as specified and directed.
S&F brass CP health faucet 15mm bore (ISI marked) including extension pipe of 1.2 m long flexible tube and wall hook etc complete all as specified and directed. Make: Jaguar Cat Part No ALD-CHR-573 or equivalent as mentioned in Appx ‘B’
S&F brass CP toilet paper holder with flap etc complete all as specified and directed. Make: Jaguar Cat Part No AKP-CHR-35753PS or equivalent as mentioned in Appx ‘B’
S&F in repairs vitreous china wash hand basin white flat back size 560 x470 mm excluding taps, waste, chain & plug and porcelain stopper but including brackets /fasteners, cutting for and pinning in ends of brackets but exclusive of fixing of supply and waste pipe etc complete all as specified and directed. Make: Jaguar Cat Part No ARS-WHT-39801 or equivalent as mentioned in Appx ‘B’
S&F 32 mm bore brass CP grating with long shank for wash hand basin etc complete all as specified and directed. Make: Jaguar Cat Part No ALD-CHR-705 or equivalent as mentioned in Appx ‘B’
S&F 32 mm bore PVC waste pipe 75 mm long etc complete all as specified and directed.
S&F brass CP bottle trap 32mm etc complete all as specified and directed. Make: Jaguar Cat Part No ALD-WHM-769L300X190 or equivalent as mentioned in Appx ‘B’
S&F in repair bib cock 15mm bore cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union etc complete all as specified and directed. Make: Jaguar Cat Part No MQT-512 or equivalent as mentioned in Appx ‘B’
S&F in repair swivel shower rose (min wt 40gm) any size with shower arm 15mm size 195mm long with band of 45 degree with flange of of PTMT (min wt 40gm) including fixing to steel pipe or union etc complete all as specified and directed.
S&F towel rail 450mm long of PTMT fixed with & including cp brass screws & wooden/plastic cleats (min wt 170gm) etc complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land etc complete all as specified and directed.
M&L for Brick work sub class B bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) etc complete all as specified and directed.
M&L brick work in half brick thick wall using Sub class B bricks built in cement mortar (1:6) etc complete all as specified and directed.
M&L for keyed pointing to random or polygonal rubble or uncoarsed or brought to up to coarses in CM 1:4 etc complete all as specified and directed.
S&F MS CP grating doom 125 mm dia with waste hole etc complete all as specified and directed.
S&F MS CP grating doom 125 mm dia etc complete all as specified and directed.
S&F capacity of 500 Litres rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old water tanks etc complete all as specified & directed.
S&F capacity of 1000 Litres rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old water tanks etc complete all as specified & directed.
S&F ball brass valves, high pressure, with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule and fixed of pipe in 20mm etc complete all as specified & directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exceeding 1.5 sqm each and removing to store etc complete all as specified and as directed.
Taking down door shutters including chowkats (without taking of shutters) exceeding 1.5 sqm but not exceeding 4 sqm etc complete all as specified and as directed.
Taking down shutters of any description exceeding 1 sqm and not exceeding 2.00 each. etc complete all as specified and directed.
S & F for Solid PVC Door Frame of the size 50 x 47mm made out of 5mm PVC sheet. The door profiles are to be reinforced with 19x19mm M.S Square tube. EPDM rubber gasket weather seal to be provided through out the frame. The profile shall be mitre cut at two corners and joined by inserting 2nos. of 150mm long brackets of 15x15mm M.S. square tube inside the 19mm x 19mm M.S. square tube and suitably screwed. etc complete all as specified and directed.
S&F in the frames at site factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement etc complete all as specified and directed by Engineer-in-charge.
S & F 35mm thick flush shutters solid core construction with block board and plywood face panels, fixed with approved adhesive including lipping all round the edges of door as per manufacturers instructions etc complete all as specified and directed by Engineer-in-charge.
M&L for decorative laminate (type 1), 0.9 mm thick colour and pattern as approved fixed as in door shutters etc complete all as specified and directed by Engineer-in-charge.
S&F 35mm thick second class hardwood factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc divided into square , with plain, chamfered or rounded, mitred and rebated sash bars any numbers , fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 etc complete all as specified and directed. Note:- Glass/gauge shall be measured and paid for separately
S&F 35mm thick factory made partly gauzed and partly panelled skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 etc complete all as specified and directed. Note:- Glass/gauge shall be measured and paid for separately
S&F in repair stainless steel cloth 0.36mm nominal dia of wire and 1.40mm average aperture and fixed with stain less steel wire staples etc complete all as specified and directed.
S&F framed work such as grills, gratings, etc, with ends of bars shouldered and / or riveted, or forged into spikes ; framed guard bars ; barred iron doors ; ladders; framed balusters; walkways ; railings ; framework of water tanks and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and directed.
S&F rolled mild steel framed work as in doors or gates of angle or other section with gusset plates rails, braces etc. complete, drilled for fixing or steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooke and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete S & F rolled mild steel Fe -290 ( Gde-E-165 ) including cutting floor at bottom to accommodate CTD bar and making good the floor to match the existing floor etc complete all as specified and directed.
S&F in repair stainless steel 100 mm butt hinges, ISI marked, etc complete all as specified and directed.
S&F in repair stainless steel tower bolts of extruded section and fixed 150mm length of bolt etc complete all as specified and directed.
S&F in repair 150mm long stainless steel handle cast moulded type etc complete all as specified and directed.
S&F in repair stainless steel sliding door bolt, plate type, 300mm long with hasp (bolt type) not less than 12mm dia with and including a minimum of 6 bolts & nuts, 4 on bolt plate and 2 on staple plate and fixed.
S&F in repair aluminium anodised 100 mm butt hinges, ISI marked, etc complete all as specified and directed.
S&F in repair aluminium anodised barrel tower bolts of extruded section and fixed 125mm length of bolt etc complete all as specified and directed.
S&F in repair 125mm long aluminium handle cast moulded type anodised etc complete all as specified and directed.
S&F in repair 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
S&F in repair 75mm long door stopper of stainless steel body and rubber shoes etc complete all as specified and directed.
S&F mild steel Helical door spring150mm long including roller and roller plate complete fixed to angle iron chowkats etc complete all as specified and directed.
S&F in repair 25 mm dia stainless steel drapery rod grade SS-304 medium weight etc complete all as specified and as directed.
S&F stainless steel brackets/ end brackets grade SS-304 for holding drapery rod etc complete all as specified and as directed.
S&F stainless steel finials suitable for 25mm dia SS 304 grade drapery rod etc complete all as specified and as directed.
M&L preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide chrome primer etc complete all as specified and as directed.
M&L preparation old untreated steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint over etc complete all as specified and directed
M&L preparing new wooden surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed.
M&L one coat of synthetic enamel paint (ordinary tint) after preparation of old painted wooden surface of any description, not otherwise described, over 10 cm width or girth etc complete all as specified and directed.
M&L preparing newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over a coat of wall care putty to make smooth the undulated surfaces etc complete all as specified and directed
M&L for complete removal of existing treatment on walls, including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over a coat of wall care putty to make smooth the undulated surfaces etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint by mechanical means over a coat of primer etc complete all as specified and directed.
M&L complete removal of existing treatment of old plastered surfaces of walls and washing, rubbing down and stopping of painted surfaces and applying two coats of exterior emulsion paint by mechanical means over a coat of primer etc complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls & applying two coats of white wash by mechanical means etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces & applying three coats of white wash by mechanical means on ceilings etc complete all as specified and directed.
M&L complete removal of existing treatment of old plastered surfaces of ceiling and washing, rubbing down and stopping of painted surfaces & applying two coats of white wash by mechanical means etc complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3m in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in (1:3) etc complete all as specified and directed .
S&F in repair plate rack of size 900mmx750mmx250mm fabricated out of 1mm thick stainless steel sheet etc complete all as specified and directed.
S&F steel window with side hung shutters factory made including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded including taking down old etc complete all as specified and directed. (Note: Mild steel wire cloth shall be measured and paid separately under respective items)
S&F steel window with side hung shutters factory made including box type hinges with steel handle and steel peg stay complete without glazing bars dovetailed or welded including taking down old etc complete all as specified and directed. (Note: Mild steel wire cloth shall be measured and paid separately under respective items)
S&F factory made steel ventilator with top hung shutter without glazing bars to receive wire guage including hinges, steel peg stay and handle including taking down old etc complete all as specified and directed.
S&F of 3mm thickness sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5sq.m in each pane including taking out old broken glass etc complete all as specified and directed.
Dismantling stone slabs in roofs, suspended floors, chajjas, landings, etc., any thickness, jointed in any mortar etc complete all as specified and directed.
M&L for sand stone slab 7.5cm thick in chajjas, landings, shelves etc not exceeding 2m in length, punched dressed on face and along expose edges, self faced on other side and set and pointed in CM (1:2) etc complete all as specified and directed.
Cutting holes into or through cement concrete slabs, chajjas etc reinforced or otherwise superficial area not exceeding 100 Sq.cm etc complete all as specified and directed.
Demolition Cement concrete (unreinforced) concrete of any description and in any position not otherwise specifically provided etc complete all as specified and directed.
M&L for surface preparation by removal of all loose particle to ensure clean, smooth and dry surface and laying 25mm thick PCC type B-0,( 1.2.4) using 12.5 mm graded stone aggregate finished even & smooth without using extra cement to cover negative slope into prop with WPC @ 3% weight of cement etc complete all as specified and directed.
M&L 10mm thick screed bed in cement mortar (1:3) on concrete surfaces to receive water proofing treatment finished even and fair etc complete all as specified and directed.
Supplying and applying fibre reinforced UV resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers and polyester and the coating shall resist 7 bars of water pressure as per DIN 1048 standards, with elongation of 220% as per ASTM D412 & crack bridging of upto 1 mm & with high SRI value conforming to ASNZ standard. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. NOTE:- UV resistant elastomeric liquid applied waterproofing treatment shall be carried out by authorised applicator of make specified in Appx 'B' and approved by Accepting Officer
M&L Kota stone slabs, 16mm thick, machine cut as in skirting, dodo, steps etc set and jointed in cement slurry over & including rendering coat of 15 mm thick in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and polishing etc complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar and removal of same from outside MOD land etc complete all as specified and directed.
M&L cement concrete type D2, (1:4:8) using 40 mm graded aggregate in sub base of floor etc complete all as specified and directed.
M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement laid over and including 25mm thick sand cushion layer etc complete all as specified and directed.
M&L machine pressed precast concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement laid over and including 25mm thick sand cushion layer etc complete all as specified and directed.
Dismantling of Plain or corrugated steel/FRP sheeting any gauge, thickness, including or similar pattern roof/wall covering etc complete all as specified and directed.
S&F pre painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and washers etc complete all as specified and directed.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 grade St-240 etc complete all as specified and directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing capping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces etc complete all as specified & directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sq mm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sq mm (Green) drawn into and including concealed rigid non-metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators as required for the following :- (Note :- Cost of cutting of chases in stone masonry and making good disturbed surfaces for concealing the conduit shall deemed to be included in quoted rate of point wiring).
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on independent board.
(e) One bell point controlled by one bell push.
(f) One light point controlled by two way switch.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sq mm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 Sq mm (Green) drawn into and including concealed rigid non-metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets as required for one 16 amp socket outlet point controlled by one switch on independent board. (Note - Cost of cutting of chases in stone masonry and making good disturbed surfaces for concealing the conduit shall be deemed included in quoted rate of point wiring). Complete all as specified & directed.
S&F angle holder, insulated polycarbonate body with back plate etc complete all as specified & directed.
S&F modular switch one way, SP, 6 amp, 1 module of make legrand mylinc cat ref No. 675501 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular switch one way, SP, 16 amp, 1 module of make legrand mylinc cat ref No. 675511 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular bell push, 6 amp, 1 module of make legrand mylinc cat ref No. 675504 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular socket 6 amp 2/3 pin combined 2 module of make legrand Mylinc cat ref no. 675550 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular socket 6/16 -2/3 pin combined 2 module of make legrand Mylinc cat ref No. 675555 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular switch two way, SP, 6 amp, 1 module of make legrand mylinc cat ref No. 675502 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular hum free electronic step fan regulator, 120 watts, 2 module of make legrand Mylinc cat ref no. 675531 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F door bell, AC 240 volts, single pole of make legrand Mylinc cat ref no. 573443 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F ceiling rose 3 plates polycarbonate body etc complete all as specified & directed.
S&F modular white cover plate with frame 1 module /2 module of make legrand Mylinc cat ref Nos. 675561-675562 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular white cover plate with frame 3 module of make legrand Mylinc cat ref No. 645563 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular white cover plate with frame 4 module of make legrand Mylinc cat ref No. 675564 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular white cover plate with frame 6 module of make legrand Mylinc cat ref No. 675566 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
S&F modular white cover plate with frame 8 module of make legrand Mylinc cat ref No. 675567 or equivalent as mentioned in Appx’B’ etc complete all as specified & directed.
M&L for submain wiring along with earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
(a) 2x4 sqmm + 1x4 sqmm earth wire in 20 mm dia conduit.
(b) 2x6 sqmm + 1x6 sqmm earth wire in 20 mm dia conduit.
(c) 4x6 sqmm + 2x6 sqmm earth wire in 25 mm dia conduit.
S&F 20 amps single pole and neutral, socket outlet, with 2 pole and earth, metal enclosures with plug top 240 volts in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet and including providing one number single pole ‘C’ series MCB 16 amp as required of make Legrand cat ref No 607841 and 408592 or equivalent as mentioned in Appx’B’.
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised iron strip 32 x 6 mm earth lead by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 40 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work etc complete all as specified & directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip etc complete all as specified & directed.
S & F MCB distribution board powder coated , CRCA steel sheet, degree of protection IP 43-IK 09 with reversible double door, recess mounted having insulated 100 Amps tinned copper bus bar, neutral busbar, earth bar detachable gland plate interconnection earthing connection , blanking plates in unused spaces including connections of wires in MCBs/RCCBs/RCBOs/MCCBs with suitable size lugs of copper materials. DBs shall be fixed on wall in flush pattern by chase cutting in stone or brick wall and disturbed surfaces shall be made good even and smooth using CM (1:3) as required with following ratings & ways:-
(a) SPN, 240 volts, 4 ways of Make Legrand cat ref No 507610 or equivalent as mentioned in Appx’B’.
(b) SPN, 240 volts, 8 ways of Make Legrand cat ref No 507611 or equivalent as mentioned in Appx’B’.
(c) TPN, 415 volts, 4 ways of Make Legrand cat ref No 507670 or equivalent as mentioned in Appx’B’.
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) Single pole 6 to 32 amps of Make Legrand cat ref Nos 408587 to 408595 or equivalent as mentioned in Appx’B’
(b) Double pole 10 to 32 amps of Make Legrand cat ref Nos 408631 to 408636 or equivalent as mentioned in Appx’B’
(c) Three pole, 40 to 63 amps of Make Legrand cat ref Nos 408659 to 408661 or equivalent as mentioned in Appx’B’
S&F in replacement 10 watt LED T -lamp B-22 base (warm white/golden yellow) 1000 lumens, height 8.0 cm width 20.5 of make Philip Cat No 9290018611 or equivalent as mentioned in Appx’B’
S&F in replacement LED (1.2M) smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens/21 watt at a minimum system efficacy of 2000 lumen per 21 watt and total power consumption not more than 21 watt including driver. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete of make Philip Cat No BN 021LED 10S 6500 /4000 GR S1 or equivalent as mentioned in Appx’B’
S&F in replacement LED (0.6 M)/ 2ft smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 1150 lumens/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete of make Philip Cat No BN 021C LED 20 PSU CDL /NW GR or equivalent as mentioned in Appx’B’
S&F in replacement LED 15 watt street light smartbrite PDC housing with IK 07 protection PC glossy diffuser duly prewired connection having a nominal system lumen output of efficiency 100 lumens/ watt light watt and total power consumption not more than 15 watt including driver. It has a rated IP 65 with 4 KV inbuilt surge protection of make Philip Cat No BRP 040 15CW R1 S1 PSU GR or equivalent as mentioned in Appx’B’
Supply and fix in replacement PVC fresh air fan 200 mm sweep with louvers, fan motor and accessories complete including making connections. Make : Bajaj/Havells/CG as approved.
Supply and fixt heavy duty Exhaust Fan 250 mm sweep with louvers, fan motor and accessories complete including making connections. Make : Bajaj/Havells/CG as approved.
Supply and fixing ceiling fan 1200mm sweep 50 Hz AC 230 volts, 5 star rated in white colour with fan motor, blade set , 0.45 m down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No on Fan body as required. Make : Havells Model No ES-50 or equivalent in Bajaj/CG as approved.
S&F in replacement surface mounted LED panel of size 220mmx220mm, 12 watt 1500 lumen output having luminous efficacy >85 Im/W, 6500K, 50Hz, p.f. .0.90, CRI80, THD ,30%, 25000 burning hours including making connection of make Philip Cat No SM 260C LD 12S-6500 PSU WH or equivalent as mentioned in Appx’B’.
Supply and fixing water heater of 25 litres capacity BEE star rating 5 in approved colour, heating element 2.0 KW adjustable temperature setting knob for temperature settings between 25 degree to 75 degree centigrade, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insulation including 15mm bore 450mm long flexible PVC pipe connection for cold water supply and 15mm bore 450mm long chromium plated metallic flexible pipe connection for hot water supply complete. Make : Havells Adonia or equivalent in Daspass/ Recold/Bajaj as approved.
Supply and fixing instant water heater of 5 litres capacity BEE star rating 5 in approved colour, heating element 1.0 KW adjustable temperature setting knob for temperature settings between 25 degree to 75 degree centigrade, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insulation including 15mm bore 450mm long flexible PVC pipe connection for cold water supply and 15mm bore 450mm long chromium plated metallic flexible pipe connection for hot water supply complete. Make : Havells Adonia or equivalent in Daspass/ Recold/Bajaj as approved.
Supply, installation, testing and commissioning of LT panel board fabricated out of 2mm thick stainless steel (SS 316) with copper bus bar 4 pole equal of capacity in colour code R, Y & B, 250 Amps 415 volts indoor type of size 750mm x 650mm x 250 mm, installed on porcelain insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class IP 42 class, front opening & compartmental type with approach for cable entry and for easy maintenance duly internally wired with FRLS, PVC insulated stranded copper conductor cable of 1.0 Sq.mm including LED indicator for R, Y & B and comprising of the following :- INCOMING :- One number MCCB 125 Amps 4 pole 16 KA 415 volts, 70-100%, 50 Hz . OUTGOING :- (a) MCB TPN 63 Amps 'C' series 10 KA AC 240 Volts -04 Nos (b)MCB DB 20 Amps 'C' series 10 KA AC 240 volts - 01 No (c)Single phase tamper proof meter with optical port 10 to 60 Amps -04 Nos . Note : Existing old energy meter shall be deposited at MES yard.
Schedule of Credit
M/S Mohan Lal Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .