| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC D 154 ADARSH NAGAR NARMADA ROAD JABALPUR 482001 M P | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹38.0 L+₹28,973 (0.77%)Rejected-Finance 1432 2 UDAI NAGAR NO 2 POST OFFICE JABALPUR MP 482009 | JABALPUR | MADHYA PRADESH | 482009 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹40.4 L+₹2.7 L (7.23%)Rejected-Finance 116 JAI BHEEM NAGAR POLIPATHAR GWARIGHAT ROAD JABALPUR MP 482008 | JABALPUR | MADHYA PRADESH | 482008 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹42.8 L+₹5.2 L (13.7%)Rejected-Finance 28 PRAGATISHEEL COLONY NARMADA ROAD JABALPUR 482001 M P | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹45.7 L+₹8.0 L (21.2%)Rejected-Finance H NO 113 APR COLONY KATANGA CANTT JABALPUR M P PIN 482001 | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48.1 L
EMD Value
₹96,260
Closing Date
29 Jun 2023, 5:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
SPECIAL REPAIRS TO BLOCK NO T-14 FGH 1 AND T-14 FGH 2 OF 1 STC OFFRS MESS, PROVN OF COVERED CAR PARKING SHED WITH HARD STANDING NEAR BLDG NO T-49 AND T-50 OTM ACCN OF MH UNDER AGE B/R-III OF GE (WEST) JABALPUR
2023_MES_599792_1
8574/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
7 documents required · 7 mandatory
₹500
GE (West) Jabalpur
₹96,260
17 Aug 2023
31 May 2023
4 Jul 2023
1 Jun 2023
29 Jun 2023
15 Jun 2023
1 Jun 2023 - 10 Jun 2023
Amount
Taking down Cement Plaster any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including cement mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris of the premises complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete of any description and in nay position complete all as specified and as directed.
Taking down chowket or frame with shutter (without taking off shutters from the frame) area not exceeding 1.5 Sqm each complete all as specified & directed.
Taking down chowkhat or frame with shutter (without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified & directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft / Loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Soft / Loose soil, complete all as specified and as directed.
Excavation in post holes each not exceeding 0.5 Cu.m, getting out in Soft / Loose soil, including returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M & L for moorum/ red bajri filling under floors laid in layers not exceeding 15 cm thick, spread levelled and rammed / rolled including watering to required level and gradient complete all as specified and as directed.
M & L for hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface in broken boulder complete all as specified and as directed.
M & L 50 mm thick sand filling under floors or in foundations including ramming, watering and consolidation complete all as specified and as directed.
M&L PCC 1:3:6 type C-0 using 12.50mm graded stone aggregate as in filling of pressed steel door frame complete all as specified and directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M&L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in paving/path finished fair and even complete alla s specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. (Note :-reinforcement where provided shall be measured and paid seprately)
M & L for brick work with sub class "B" bricks, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for brick work with sub class "B" bricks, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:4 complete all as specified and as directed.
Brickwork with subclass ‘B’ bricks, old size straight or curved on plan to any radius in half brick thick walls built in in CM 1:4 complete all as specified and as directed.
Supply only liquid integral water proofing compound
M&L for Cutting holes in brick walls exc half brick and nexc one brick in cement in mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and as directed.
S&F, 40 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides decorative face veneer with lipping/frame to match supplied and fitted to chowkats.complete all as specified and as directed.
S&F 25 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats.complete all as specified and as directed.
S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part -I,section 8,clause 8.24 (a) complete all as specified and as directed.fitted to chowkhats for doors etc complete all as specified and as directed.
S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm complete all as specified and as directed.
S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm complete all as specified and as directed
S & F Aluminium alloy, anodised, Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, Type B-21 complete all as specified and directed.
S&F continuos (piano) hinges, mild steel bright finish or electrogalvanised, width of flaps 30 mm complete all as specified and as directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and as directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 125 mm complete all as specified and directed.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel spring complete all as specified and directed.
S&F 300 mm long mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed.
S&F 125mm hasp and staples, aluminium anodized including bolt to hinges plate and fixed with screws complete all as specified and directed
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified.
S&F aluminium hat & coat hooks solid body 125 mm to 175 mm fixed with brass screw complete all as specified and directed.
S&F MS Peg set of six powder coated as approved complete all specified and directed
M&L for mild steel pipe 25 mm dia Drapery rod fancy type with PVC coating fixed in the MS hooks, and finials/ side brackets (both side), shade as approved by GE all as specified.
S & F pressed steel door frame 125x60 mm with one or more rebates including necessary fixing lugs hings, lock strick plates, etc complete all as specified and as directed.
S&F factory made steel windows with side hung shutter including box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F factory made steel windows with side hung shutter including box type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F rolled mild steel structural work in tubular trusses (frames), trussed, fixed with and including special shaped washer etc.complete using ERW or including butt welded tubes confirming to IS 1161-1998 complete all as specified and as directed.
S&F mild steel framed work such as guard bars/grills, grating etc with end of bars shouldered and/or riveted or forged into spikes and similar works including one shop coat of zinc chromate primer complete all as specified and as directed.
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe410-0 or Fe 310-0 complete all as specified and directed.
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or weleded attachement confirming to Fe- 290 (Gde E-165) complete all as specified and directed.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters, fixed with angle cleats or other connecting plates of Gde fe 410-W or E 250 (quality A) complete all as specified and as directed.
S & F MS machine made screw bolts with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut exceeding 22.50 cm and not exceeding 30 cm long, dia of neck exceeding 20 mm but not exceeding 25 mm complete all as specified and as directed.
M&L Pre-painted galvatume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
M&L Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
M&L for 9 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work as in repair all as specified
M&L for 18/19 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work, complete all as specified and as directed.
S&F suspended prepainted false ceiling, self design, self texture, using chicago metalic (E grid) exposed suspended system, grid section size 600mm x 600mm comprising of GI powder coated main runner of dimensions 39mm x 24mmx 08mm thick (thickness comprising of GI /0.4+PPPCGS/0.3mm & weight of runner 1.35 Kg for 3600mm length) cross tee of dimensions 29mm x 24mm 0.8mm thick and thick wall angle 22.2 mm x 22.2mmx 0.65mm thick (thickness comprising of GI /0.35+PPPCGS/0.3mm & weight of angle 0.70 Kg for 3050mm lenght) with and including 4mm thick HPSC (high pressure steam cured) pre-primed, self embossed, texture designer board, water resistant termitant, fire resistant for insulation and acoustic purpose to be placed in the grid systemduly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips (wt - 0.007 Kg/clip) hold down clips (wt-0.0035 Kg/clip) with provn of light fixture complete all as specified and as directed.
Fixing only 6mm to thick in ceiling flat or sloping Non asbestos cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work fixed with screw as per manufacturer's instructions complete all as specified and as directed.
S&F in repair 18/19 mm thick water proof block board of exterior grade Gde-I fixed with screws as kitchen, cup board box and shutters & shelves etc complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 450 x 300 x 6 to 7 mm, 450x350 or 350x250 6 to 7mm thick on vertical surfaces such as skirting/ dado etc. ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile with & including rendering 10 mm thick cement plaster in cement mortar 1:4 finished rough to receive tiles complete all as specified and as directed.
M&L Non skid coloured ceramic tiles 7 to 8mm thick square/ rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed.
M & L for 20-25mm thick Machine cut Cudappha stone slab as in cooking platform/ shelf laid over and including 20mm cement screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 20 to 25 mm thick machine cut kota stone flooring laid over cement screed bed 20 mm thick bedding layer in cement mortar 1:6 and jointed with neat cement slurry mixed with pigment to match the shade of the slab and including rubbing and polishing complete all as specified and as directed.
M&L for 18 to 20 mm thick machine cut kota stone as in vertical surfaces, risers of steps, skirting, dado and pillars etc laid over and including 10 mm thick rendering in cement mortar 1:4, set and jointed in neat cement slurry and pointed with grey cement mixed with pigment to match the colour of stone slab and including rubbing and mirror polishing complete all as specified and as directed.
M&L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete all as specified and as directed.
M & L for 100mm thick PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for 75mm thick PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in paved area and path finished fair and even complete all as specified and as directed.
M & L for 100mm thick PCC 1:2:4, Type B-2, using 40mm graded stone aggregate as in paved area and path finished fair and even complete all as specified and as directed.
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M&L for 60mm thick, coloured, rubber moulded, M 35 grade, Machine pressed precast concrete interlocking paver block of any shape and size jointed and pointed with grey cement and no pigment, confirming to IS 15658-2006, complete all as specified and as directed.
M&L for 80mm thick, coloured, rubber moulded, M 40 grade, Machine pressed precast concrete interlocking paver block of any shape and size jointed and pointed with grey cement and pigment, confirming to IS 15658-2006, complete all as specified and as directed.
M&L for 10mm thick rendering in cement mortar 1:6 on fair faces brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L 15mm thick rendering on fair faces of concrete/brick surfaces in CM 1:4 mixed with water proofing compound as per manufactures instruction finished even and smooth without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid sperately.
M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper over a coat of primer over and including 3 mm thick wall care putty on plastered wall surfaces complete all as specified and as directed.
M&L for Preparing Newly Plastered Surfaces of external Walls and applying two coats of Cement Base Paint over a coat of alkali resistance primer complete all as as specified and as directed.
M & L for complete removal of existing wall surface finishes of any description and applying two coats of cement based paint over a coat of alkali resistant primer on walls complete all as specified and as directed.
M & L for complete removal of existing wall surface finishes of any description and applying two coats of oil bound distemper over one coat of primer over and including 2mm thick wall care putty and preparation of surfaces complete all as specified and as directed.
S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
M&L for Prepration of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of white or tinted complete all as specified and as specified.
M&L for Prepration of old painted surfaces of steel of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for treating small article such as stops, covers, gully, gratings and hold fast ends & post backs of chowkat etc with creosote oil, tarred area n exc 0.10 Sqm each complete all as specified and as directed.
M&L for Preparation of new steel surfaces of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for Prepration of newly painted steel surfaces of any description n exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer surface complete all as specified.
M&L for preapring surfaces of wood and wood based materials,old surfaces of any descriptionand girth,not otherwise described and treated with one coat of creosote oil complete all as specified and directed.
M&L for GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Taking down carefully any type of old unserviceable point wiring (light, fan, socket bell or power) , complete with fittings such as switches ceiling roses, lamp holders sockets, regulators with PVC conduit surface /concealed or wooden patterns including sunken cast iron /pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and directed.
Taking down carefully Main switch and Distribution boards any make and size complete all as specified and as directed .
Taking down the ceiling fan in situ and removing to MES store complete all as specified and directed.
Taking down carefully Old unserviceable any type sub main wiring with wooden batten/ PVC surface conduit of any size and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and directed.
M/L for Sub Main Wiring with two single core PVC insulated cable FRLSH of size 4.0 Sqmm multistranded copper conductor FRLSH cable drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 20mm dia with all conduit fitting, fixing accessories and 4 Sqmm multistrand copper conductor FRLSH cable as continuous earth wire complete all as specified and as directed. Note :- Two Nos of 4.0 Sqmm Wire and One No of 4 Sqmm Earth wire in One RM length Measured as one unit length.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor FRLSH cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of anticorrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white Bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor FRLSH cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed.
(a) One light point/fan point/bell point controlled by one switch.
(b) One socket point controlled by one switch on same board.
(c) One socket point controlled by one switch on Independent board.
All as described in serial item No. 91 here-in-before, but with 1100 volts grade copper standard conductor FRLSH cable of size 2.5 Sqmm with 2.5 Sqmm solid copper conductor cable for 3 pin 15 Amp switch socket outlet independent board complete all as specified and directed.
S & F in repair for switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
S & F Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed.
S & F switch socket combination 3 pin 5 and 16 Amps AC 230 volts flush type complete all as specified and as directed.
S & F Ceiling rose surface bakelite 65 mm x 50 mm three terminal AC 230 volts flush type complete all as specified and as directed.
S&F fan regulator Step type of polycarbonate complete all as specified and as directed.
Supply and fixing Single phase ceiling fan 1200 mm permanent magnet brushless DC Motor 230 v 50 Hz single phase 26-30watt rated current 0.16 amp,pf 0.98 370/360 rpm air delivery 220m3 rated service value 629m3/min/watt no of blades three type of blade leaf 1.05 mm thick aluminium sheet remote control radio frequency 5 speed +off timer option speed regulation class of insulation two nos bearings including connecting wire complete with all as required and directed at site by eng in charge Make : Havells/ CG/ Bajaj
S&F in repairs Smart bright Batten Series, LED luminaire using LED 22 watt 110 Lumens/watt with diffuser which ensures uniform distribution and comfort, batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminium housing, Energy efficient, Flicker free start Inbuilt driver unit, Suitable for wall and ceiling mounting using brackets with and including the luminaire testing on completion as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), (Make : Philips Cat part No BN 021 LED 22S 6500/4000 PSU GR S1 or equivalent makes as mentioned here-in-after.
Supply & fix in replacement of LED Security Light Luminaire 35 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed. Make:Surya cat part no: NGN SLEUL25WIP66 or equivalent makes in PHILIPS and Havells as mentioned here-in-after.
Supply & Fixing sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand CAT NO 507611 / SIEMENS CAT NO 8 GB 32102RC8/GE
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed. Make:- Legrand/ havells or Equivalent
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.Make : Legrand DX3 DP CAT No 408637/ Siemens cat no- 5SL 42327RC / GE
S & F for MCB Single pole rated capacity 5 to 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.Make : Legrand cat no DX3 SP 408587,408590,408592,408593,408594,408595 / Siemens cat no- 5SL41067RC, 5SL41107RC, 5SL41167RC, 5SL41207RC, 5SL41257RC, 5SL41327RC / GE
S & F in repair Bulk head endura LED light fitting complete with10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suiyable size & length complete all as specified & directed. Make :Havells Cat Part No. HEXAFT10WLED857SSYMBOPC or Equivalent make Philips / BAJAJ / WIPRO
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
S&F in replacement of sheet steel enclouser distribution boards, double door factory made VTPN 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 63 amps , circuits comprising of 3 phase 4 wire of suitable rating all as specified and directed.Make of Distribution Board Legrand cat no:5077 50 or equivalent in seimens /GE and Make of MCBs :Legrand/Seimens/GE
S & F MCB TPN 63 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Legrand / L&T / Havells)(Note :- Proper and suitable size cablecopper lugs to be fixed with MCBs are included in unit rate of each MCB of any rating)
Supply and fixing Single phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 380 mm sweep, metallic body complete with Metalic louvers including making holes of suitable size and making good the disturbed surface and shutters including electric connection with pvc flexible twin core copper wire from ceiling rose to Exhaust fan, nut & bolt complete all as specified and as directed.Make:Bajaj,havells or equivalent.
S&F decorative wall light fitting WITH LAMPS 9 WATT made up of Polycarbonate, City-1, Cylindrical shape, with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed. Make:City 1 of havells or equivalent makes mentioned here-in-after.
Supply, installation, commissioning and testing indoor wall mounting LT Panel Board of minimum size 1.20 m (height) x 1.20 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of Seven nos single phase meter and MCB and providing glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/wire busbar of suitable size to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 1.5 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as directed by Engineer-in-Charge. (For JCO/ORs, Civilian Md Accn 04 Qtrs)
OUTGOING :- (a) MCB, Single pole & neutral, 40 amps, 240 volts, 'C' curve, 10 KA all complete as specified and as directed -04 Nos (b) MCB, Single pole & neutral, 10 amps, 240 volts, 'C' curve, 10 KA all complete as specified and as directed - 1 No.(stair case lighting) (c) Fixing only serviceable existing electric meter - 01 No. (d) Smart Single Phase Meter AC single phase two wire, tamper proof, static meter of class 1.0, 240Volts, 50 Hz of capacity 10 Amps-60 Amps conforming to IS-16444 and relevant IEC standards with in built 865-867 MHz radio frequency communication facility with self healing mesh netork with default and on demand display, billing data generation facility, antitemper features, microprocessor and LED/LCD based circuitry. Meter should support the follwing data: 30 min instantanous data for voltage, current, power factor, power cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for cumulative energy and max demand. Meter should have connnect/disconnect funtionality operable compactable system from prepaid billing software in future. The meter should support open communication protocol DLMS with the software. 04 Nos. (Make-L&T, Secure, Schneider)
Supply , laying and testsilng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 3.5 core 35 Sqmm complete all as specified and directed.
M&L for cuttng of existing road to a required width and depth and making good the surfaces with PCC 1:2:4 type B1 using 20mm graded aggregates after laying the cable through GI pipe etc complete all as specified and directed.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. NOTE : Punned thickness only shall be measured and paid.
Supply and lay bricks sub class 'B' laid dry abutting each other with gap between adjacent slab not exc 10mm over UG cabel as in cable protection complete all as specified and as directed.
M/S RAJ BUILDERS
chandra builders
Tiki Water proofing Co
DEEPAK CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .