COL VIKAS KESARWANI
CWE AF LOHEGAON
REPAIR / REPLACEMENT AND MAINTENANCE OF UNSERVICEABLE ITEMS OF CENTRAL AC PLANT PACKAGE TYPE AC PLANT ELECTRICAL PANEL AND MISC ITEMS OF AC PLANTS AT AF STN PUNE
2022_MES_540234_1
81858/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF LOHEGAON
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF LOHEGAON
₹88,000
Yes
29 Sept 2022
22 Jul 2022
25 Aug 2022
22 Jul 2022
17 Aug 2022
5 Aug 2022
Amount
M&L for taking out three way actuvator valve 65mm to 125mm of chiller line & refiixing duly carry out its servicing , replacing its defective parts including checking the control wiring with humidistat and making setting to control the desired temp & RH complete as reqd at site and to maintain desired RH& Temp of central water cooled AC palnts up to 200 TR complete all as specified and directed by Engr-in-charge.
M&L for taking out unsv PVC fills of cooling tower up to 20 to 100 TR cap (bottle/rectangular type) after taking down cooling tower motor and keeping aside, cleaning the hydrent pipe, sprinkler assembly and inside complete body of cooling tower complete all as specified and directed by Engr-in-charge.
Supply & fixing PVC fills of cooling tower 20 to 40 TR as per OEM standard fixing sequance including cutting & filling the gaps so that the water of cooling tower spread equally complete all as specified and directed by Engr-in-charge.
Supply & fixing PVC fills of cooling tower 41 to 100 TR as per OEM standard fixing sequance including cutting & filling the gaps so that the water of cooling tower spread equally complete all as specified and directed by Engr-in-charge
M&L for replacement of defective sprinkler assy complete as per existing type & model of cooling tower cap 20 to 60 TR complete all as specified and directed by Engr-in-charge.
M&L for replacement of defective temp sensor of chiller line as per existing make & model complete all as specified & directed by Engr - in- Charge.
M&L for replacement of defective temperature controller with sensor including making proper wiring & connections complete all as specified & directed by Engr - in- Charge.
M&L for replacement of defective humidity controller with sensor including making proper wiring & connections complete all as specified & directed by Engr in Cahrge.
M&L for replacement of unsv flow switch of chiller & condensor line 63 to 200mm dia line , including making all control conections complete all as specified & directed by Engr in Charge.
M&L for cleaning of Y strainer & Pot strainer of central AC plant 65 to 250mm of Chiller line, condensor line by carefully opening the top & taking out the strainer and refixing after clening/wash out the line durt/sludge & replacement of defective nut,bolts, rubber gasket, dameged strainer as per existting size if required. After clening filling water in condenser/ chiller line by using additional pump, taking out the air in chiller & condensor line complete all as reqd at site & directed by Engr in Charge.
M& L for servicing of outdoor (condenser) unit of air cooled central/ Package type AC plant by cleaning of fins by water jet of suitable pressure or cleaning by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking electrical wiring, servicing, oiling of condenser motor, etc. complete as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable fan blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) as per existing make, model and type complete all as specified and directed by Engr-in-charge.
S&F in replacement of blower belt of AHU/Compressor belts as per existing model and type ISI marked including re-alignment of the motor and blower if required for proper tension of belts complete all as specified and directed by Engr-in-charge.
M&L for servicing of electric control panel of AHU central/Package type AC Plant by cleaning the panel with blower, checking of electric circuits/connections, replacement of unsv burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unsv item (taken as supply only) complete all as specified and directed by Engr-in-charge. Note: (i) Unserviceable parts as MCB, MCCB, contactor, relay etc. will be measure and paid separately. (ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in quoted rate.
M&L for servicing of Main Electric Panel board/Control panel board of Central/Package type AC Plant by cleaning the panel with blower, replacement of unsv burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unsv item (taken as supply only) complete all as specified and directed by Engr-in-charge. Note: (i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately. (ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in quoted rate.
Supply only the following items ( for use in Ser item No. 14 & 15 wherever required) complete all as specified and directed bt Engr-in- Charge:-
MCB 6-32 Amp SP C series
MCB TPN 40 to 63Amp C series
MCB TPN 10 to 32 Amp C series
Power contactors 415 V, AC, 9 to 25 Amps, 3ph
Power contactor 415 V, AC, 32 to 40 Amps, 3ph
Power contactor 415 V, AC, 45 to 60 Amps, 3ph c
Power contactor 415 V, AC, 63 to 75 Amps, 3ph
Add on Auxiliary contact block (MNX A-2 /MNX A-1/TA1-DN22)
HRC fuse link RH type having breaking capacity 80 kA ( 2-32 amps)
HRC fuse link bottle/Din type having breaking capacity 80 kA (36 to 63 amps)
HRC fuse link bottle/Din type having breaking capacity 80 kA (80 to 125 amps)
Fuse bases for HRC fuse up to 32 Amp
Fuse Base for fixed type up 63 to 125Amp
Contactor MNX9
Contactor MNX18
Contactor MNX25
Contactor MNX32
Contactor MNX70
Thermal Over Load Relay (Auto/Manual reset) suitable for contractors (Relay range 2.5-t to 9-13 Amps )
Thermal Over Load Relay (Auto/Manual reset) suitable for contractors (Relay range 23-32 to 30-40 Amps
PVC connector 15 to 60 Amps
Electronic Timers 110/240/360/415Volts 50 Hz for (3-10/ 9-30/36-120 Sec)
Single phase preventer suitable for 3 HP to 15 HP Monoblock pump sets
R/Y/Phase/On/Trip indicating lamps (as per colour code)
M&L for decaling of condenser with dilute sulphuric acid solution (as per OEM manufacturers specification) by using decaling pump for circulation of solution and brushing with nylon brush by opening both side covers and cleaning/flushing out the dirt, sludge with water up to satisfaction of Engr in charge and re-fixing the side cover with new gasket, replacement of worn out nut, bolts & washers and leak detection complete all as specified and directed by Engr-in-charge for following capacity:-
Capacity 10TR
Capacity from 11 to 20 TR
Capacity from 21 TR to 30 TR
Capacity from 31 TR to 100TR
M&L for replacement or top-up of u/s burnt compressor oil and charging with new lubricant oil for open type reciprocating compressor as per manufacturer's instruction complete all as specified and directed by Engr-in-charge.
M&L for refrigerant gas R-22 including charging in compressors as per OEM specification complete all as specified and directed by Engr-in-charge.
M&L for refrigerant gas R-407 including charging in compressors as per OEM specification complete all as specified and directed by Engr-in-charge
M&L for replacement of unserviceable Humidistat with digital humidistat and checking electrical wiring , making proper setting to achive desired humidity complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable heater strip type 3kW capacity as per existing make & model complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable heater strip type 4kW capacity as per existing make & model complete all as specified and directed by Engr-in-charge.
Material and labour for taking out unsv burnt electric motor of (compressor/Monoblock pump set /Blower/condenser/cooling tower) and rewinding the same by removing the burn out copper coil cleaning the motor and winding with super enameld copper wire of same gauge & turns including varnishing, providing new insulation sheet, heating the winding including replacement of unsv both end bearings, bush of existing size etc reqd at site, refixing to its original place and testing after repair complete all as specified and directed by Engr in charge for following capacity:-
Up to 2 HP single /three Phase
3 HP 3 phase
5 HP 3 phase
7.5 HP 3 phase
10 HP 3 phase
12.5 HP 3 phase
15 HP 3 phase
M&L for servicing and repairing of Monoblock Centrifugal pump set by greasing, cleaning the shaft, replacing unsv gland packing, bush, water seal, bearing etc of existing size, replacement of unserviceable nut, bots & washers, gasket etc. as required at site 3 to 15 HP pump set complete all as specified and directed by Engr-in-Charge.
M&L for replacement of air filters of Package type AC plant of cap 5 to 11 TR as per existing size, model & filtration capacity complete all as specified and directed by Engr-in-charge.
M&L for servicing of pan type humidifier floor mounted/ installed at duct of capacity 6 /12 kW including cleaning of tank, checking of all inlet & outlet connection, checking and repair of all electrical control connections and making the pan type humidifier functional including replacement of heating elements of existing make & model, replacment of minor parts complete all as specified and directed by Engr-in-charge.
M&L for repair of existing unsv micro processor card through OEM service Center, Type MPD / μ-MVPD/M3PD 30-220 Amps, 230 V of control panel of chiller unit 15 to 100 TR including replacement of u/s parts like push button/ Key board, indicating light, display board, mother board etc. and testing, calibrating the functions with plant after repair etc complete all as specified and directed by Engr-in-charge.
M&L for repair of existing unsv VLRP controller of chiller unit 15 to 100 TR cap including replacement of u/s parts like push button/ Key board, indicating light, display board, mother board etc. and testing, calibrating the functions with plant after repair etc complete all as specified and directed by Engr-in-charge.
M&L for servicing, cleaning of Cooling tower of AC plant up to 200 TR Cap including cleaning the storage tank, removal of all sludge , servicing, greasing of cooling tower motor with hub assembly etc complete all as specified and directed by Engr-in-charge.
M&L for leak detection of central/package type Ac plant 6.5 TR to 50TR cap,water/Air cooled including vaccum the refrigrent gas by using vaccum pump, giving suitable nitrogen pressure as per site condition holding the nitrogen pressure, detection of leakage by soap foam test, cutting, brazing to leak condenser coil, refrigrent piping & testing after brazing work after holding pressure again vaccum the system etc complete all as specified & directed by Engr in charge. Note:- Refrigerant gas & oil shall be measured and paid separately
M&L for leak detection of central/package type Ac plant 75 TR to 100TR cap water/air cooled , including vaccum the refrigrent gas by using vaccum pump, giving suitable nitrogen pressure as per site condition holding the nitrogen pressure, detection of leakage by soap foam test, cutting, brazing to leak condenser coil, refrigrent piping & testing after brazing work after holding pressure again vaccum the system etc complete all as specified & directed by Engr in charge. Note: Refrigrant gas & Oil shall be measured & paid separatly.
M&L for replacement of Shaft seal assembly complete including leak testing and making compressor serviceable (Compressor as per existing installed model capacity 12 to 30 TR) complete all as specified and directed by Engr-in-charge. Note:- (i) Necessary topping up of refrigerant & oil shall be measured and paid in respective items
M&L for servicing of compressor by disconnecting /detaching from motor after pump down the system and taking out the parts after strip opening of compressor (15 TR) Cleaning the parts of compressor & segregation of serviceable/unserviceable parts, keeping serviceable parts aside for reuse and replacing the worn out parts (taken as supply only), turning, lathe work on crank shaft if required, Reassembling the complete compressor parts, including checking leak test by using nitrogen pressure test at suitable pressure, vacuum the compressor by using vacuum pump & filling oil and charging of gas R-22, testing and commissioning of complete system as per OEM complete all as specified and directed by Engr in charge. Note: (i) Work shall be carried out through OEM Mechanics or Mechanic having 10 Years experience of repair of the compressor. (ii) Unserviceable nut, bolts, washers, springs etc. found unserviceable will be replaced and deemed to be included in quoted rate. (iii) Major spare parts, compressor oil and Frozen gas shall be measured and paid separately.
Supply only the following items (for use in item No. 34 above as required) complete all as specified and directed by Engr-in-charge.
Connecting rod with bearing
Piston with pin and rings
Shaft seal assly
O' Ring set
Suction Strainer
Gasket set
Oil pump assembly
Aluminium Washer Set
Oil strainer
Solenoid valve
Crank Case Heater
Pressure sensor
M&L for servicing of compressor by disconnecting /detaching from motor after pump down the system and taking out the parts after strip opening of compressor ( SMC 4x65, 1x13 TR) Cleaning the parts of compressor & segregation of serviceable/unserviceable parts, keeping serviceable parts aside for reuse and replacing the worn out parts (taken as supply only), turning, lathe work on crank shaft if required, Reassembling the complete compressor parts, including checking leak test by using nitrogen pressure test at suitable pressure, vacuum the compressor by using vacuum pump & filling oil and charging of gas R-22, testing and commissioning of complete system as per OEM complete all as specified and directed by Engr in charge. Note: (i) Work shall be carried out through OEM Mechanics or Mechanic having 10 Years experience of repair of the compressor. (ii) Unserviceable nut, bolts, washers, springs etc. found unserviceable will be replaced and deemed to be included in quoted rate. (iii) Major spare parts, compressor oil and Frozen gas shall be measured and paid separately.
Supply only the following items for above item no-36 (13TR) complete all as specified and directed by Engr-in-charge.
Connecting rod with bearing
Piston with pin and ring
Suc/ Discharge valve assly
Shaft seal assly
O' ring set
Gasket set
Oil pump assembly
Suction strainer
Oil strainer
Solenoid valve
Crank case heater
Crank shaft
Cylinder Liner
M&L for replacement of fan propellor 36" (914.4mm) 28mm bore 3 HP Part No AC2004356028 of outdoor condenser unit of air cooled package AC plant (for AC Model No ACDS075DMN2x2 Voltas ) complete all as specified and directed by Engr-in-charge
M&L for replacement Air cooled condensor fan motor of cap 2.2KW,3 HP suitable for working on 3 phase 415V, 50 Hz Ac supply induction motor having IP 55, Ins Cl -F, 945 RPM, Frame 112MV for AC plant (for AC Model No ACDS075DMN2x2 Voltas ) complete all as specified and directed by Engr-in-charge.
M&L for replacement of blower motor of package unit (5.5/7.5/11 TR capacity) as per existing model & type by dismantling existing unsv blower motor complete all as specified and directed by Engr-in-charge.
M&L taking out unsv MPD and its control panel of package type AC plant (5.5/7.5/11 TR) air cooled for carry out repair through service center including replacement of unsv parts of MPD and refixing to its original place after carry out repair and testing the plant complete all as specified and directed by Engr-in-charge.
S&F in replacement of blower belt for package unit(5.5 to 11TR) as per existing type & model and type ISI marked complete all as specified and directed by Engr-in-charge
M&L for replacement of HP/LP cut out suitable for compressor (5 to 18 TR) of package/central type AC plant including cutting, brazing and leakage testing complete as required at site and testing after replacement complete all as specified and directed by Engr-in-charge
M&L for replacement of unsv scroll type compressor of package type ac plant of cap 5.5 TR capacity suitable for working on 380-415V, 3 phase, 50Hz, having lubricant oil-PVE, heater including cutting brazing to inlet out let refrigerant piping, , nitrogen pressure test for leakage testing, vacuum the system and charging suitable Refrigerant gas and testing after replacement , Make - Danfoss commercial compressors (for AC Model No -HLP072T4LC6, Tech No- XRH722BE01) complete all as specified and directed by Engr-in-charge. Note:- Refrigerant gas shall be measured and paid in respective item.
M&L for replacement of Unsv MPD of central AC plant, Model No- M3 PD, Type- µMPD, Range- 5-30A, Aux Supply-15VAC, Special- 5 Sec and testing after replacement complete all as specified and directed by Engr-in-charge.
M&L for replacement of Unsv MPD of central AC plant, Model No- VLRP single , Type Delux, Ramge 6/6/4 Aux supply 8V&12V, and testing after replacement complete all as specified and directed by Engr-in-charge.
M&L for replacement of Unsv μMVPD of central AC plant, Model No- EC, Type- MVPD, Range- 30-220 Amps, Aux Supply-230VAC, Special- 5 Sec curve MPD and testing after replacement complete all as specified and directed by Engr-in-charge.
M&L for replacement of crank case heater of scroll type compressor suitable for 5 to 18 TR capacity as per existing type capacity and model complete all as specified and directed by Engr-in-charge .
M&L for replacement of unsv fusible link for fire dampers, UL listed fusible link complete all as specified and directed by Engr-in-charge.
M&L for replacement of switch disconnector TPN having 415 volts, with fusible link complete all as specified and directed by Engineer - in- Charge of following capacity:-
315 Amp (Model No FN 315)
125 Amp (Model No FN 125 )
32 Amps (Model No FN 32 )
250 Amps (Model No FN 250 )
M&L for repairing of PCB control & monitoring card, replacment of temp sensor as per existing type & model of hot water generator and making hot water generator servicable ( Model No- VW140) complete all as specified and directed by Engr-in-charge.
M&L for refrigerant gas R-134a including charging in compressors as per OEM specification complete all as specified and directed by Engr-in-charge
M&L for servicing of compressor by disconnecting /detaching from motor after pump down the system and taking out the parts after strip opening of compressor ( capacity 6.5 TR.) Cleaning the parts of compressor & segregation of serviceable/unserviceable parts, keeping serviceable parts aside for reuse and replacing the worn out parts (taken as supply only), turning, lathe work on crank shaft if required, Reassembling the complete compressor parts, including checking leak test by using nitrogen pressure test at suitable pressure, vacuumed the compressor by using vacuum pump & filling oil and charging of gas R-22, testing and commissioning of complete system as per OEM complete all as specified and directed by Engr-in-charge. Note: (i) Work shall be carried out through OEM Mechanics or Mechanic having 10 Years experience of repair of the compressor. (ii) Unserviceable nut, bolts, washers, springs etc. found unserviceable will be replaced and deemed to be included in quoted rate. (iii) Major spare parts, compressor oil and Frozen gas shall be measured and paid separately.
Supply only the following spare parts suitable for compressor (Voltas Model: 06D18 (6.5 TR) complete all as specified and directed by Engr-in-charge.
Such/Discharge valve assembly complete
Piston set with piston rings and piston pin complete
Connecting rod with CR bush and bearing complete
Shaft seal assly complete
O' ring set complete
Gasket set
Oil pump assembly
Suction strainer filter
Oil strainer filter
Solenoid valve
Crank case heater
HP/LP cut-out switch
M&L for servicing of compressor by disconnecting /detaching from motor after pump down the system and taking out the parts after strip opening of compressor. Cleaning the parts of compressor & segregation of serviceable/unserviceable parts, keeping serviceable parts aside for reuse and replacing the worn out parts (taken as supply only), turning, lathe work on crank shaft if required, Reassembling the complete compressor parts, including checking leak test by using nitrogen pressure test at suitable pressure, vacuum the compressor by using vacuum pump & filling oil and charging of gas R-22, testing and commissioning of complete system as per OEM complete all as specified and directed by Engr-in-charge. Note: (i) Work shall be carried out through OEM Mechanics or Mechanic having 10 Years experience of repair of the compressor. (ii) Unserviceable nut, bolts, washers, springs etc. found unserviceable will be replaced and deemed to be included in the job work rate. (iii) Major spare parts, compressor oil and Frozen gas shall be measured and paid separately.
Supply only of followings items suitable for compressor complete all as specified and directed by Engr-in-charge:-
Cylinder liners with unloading ring with pin
Piston set with piston rings and piston pin
Connecting rod with CR bush and bearing
Suction/ Discharge valve assly
Shaft seal assly
'O' ring set.
Gasket set
Heater
SV and DV reed set
Oil pressure regulating valve
Oil filter assembly
Filter Bag
Aluminum washer set
Coil for solenoid valve
Solenoid valve
Cut Out LP HP
Loading unloading frame
Oil Pump
Coupling for oil pump
Crank Shaft
M&L for servicing of compressor by disconnecting /detaching from motor after pump down the system and taking out the parts after strip opening of compressor Cleaning the parts of compressor & segregation of serviceable/unserviceable parts, keeping serviceable parts aside for reuse and replacing the worn out parts (taken as supply only), turning, lathe work on crank shaft if required, Reassembling the complete compressor parts, including checking leak test by using nitrogen pressure test at suitable pressure, vacuum the compressor by using vacuum pump & filling oil and charging of gas R-22, testing and commissioning of complete system as per OEM complete all as specified and directed by Engr-in-charge. Note: (i) Work shall be carried out through OEM Mechanics or Mechanic having 10 Years experience of repair of the compressor. (ii) Unserviceable nut, bolts, washers, springs etc. will be replaced and deemed to be included in the job work rate. (iii) Major spare parts, compressor oil and Frozen gas shall be measured and paid separately.
Supply only the following parts (for Srl item No- 58 above) complete all as specified and directed by Engr-in-charge:-
Connecting rod with bearing
Piston with pin and ring
Suc/ Discharge valve assly
Shaft seal assly
O' ring set
Gasket set
Oil pump assembly
Suction strainer
Oil strainer
Solenoid valve
Crank case heater
Pressure sensor
M&L for servicing of compressor by disconnecting /detaching from motor after pump down the system and taking out the parts after strip opening of compressor Cleaning the parts of compressor & segregation of serviceable/unserviceable parts, keeping serviceable parts aside for reuse and replacing the worn out parts (taken as supply only), turning, lathe work on crank shaft if required, Reassembling the complete compressor parts, including checking leak test by using nitrogen pressure test at suitable pressure, vacuum the compressor by using vacuum pump & filling oil and charging of gas R-22, testing and commissioning of complete system as per OEM complete all as specified and directed by Engr-in-charge. Note: (i) Work shall be carried out through OEM Mechanics or Mechanic having 10 Years experience of repair of the compressor. (ii) Unserviceable nut, bolts, washers, springs etc. will be replaced and deemed to be included in quoted rate. (iii) Major spare parts, compressor oil and Frozen gas shall be measured and paid separately.
Supply only the following items (for Srl item No-60 above) complete all as specified and directed by Engr-in-charge.
Connecting rod with bearing
Piston with pin and ring
Suc/ Discharge valve assly
Shaft seal assly
O' ring set
Gasket set
Oil pump
Suction strainer
Oil strainer
Solenoid valve
Crank case heater
Pressure sensor
M&L for replacement of old unsv MCCB-160 amps current carrying capacity 25 KA ,AC 415 Volts four pole with adjustable magnetic/ thermal setting having Ics= 100% Icu complete all as specified and directed by Engr-in- Charge.
M&L for replacement of old unsv MCCB-125 amps current carrying capacity, 25 KA ,AC 415 Volts four pole (DH series) with adjustable magnetic/ thermal setting having Ics=100%Icu complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of dia 25mm complete all as specified and directed by Engr-in-charge
Supply and fixing GI pipe light grade with all connected accessories of sizes 100 mm complete all as specified and directed by Engr-in-charge.
M&L for duct thermal insulation class O nitrile rubber based thermal insulation 19 mm thick with treated woven glass fibre covering of 0.18mm thick, density of 200+20 GSM, Tensile strength 275+-25 Kg/mm for exposed to sun application (green colour) including fixing with adhesive which is specifically formulated for duct insulation which shall be free from benzene and joints shall be fixed with glass cloth foil based tape with self adhesive ability to ensure 100% leak proof, including taking out existing unsv insulation material, cleaning the duct surface complete all as specified by OEM complete all as specified and directed by Engr-in-charge.
M&L for taking out carefully damaged ducting including all accessories complete all as specified and directed by Engr in Charge.
Supply assembly and erection of GI sheet rectangular/square duct made out of L shaped hollow profile, duly factory boxed, incl all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 22 gauge all as specified and including with required scaffolding work to install the ducts at site complete all as specified and directed by Engineer in Charge. Note :-(i) for measurement only the final finished area in Sqmm shall be measured. (ii) Venes, splitters, MS frames for joints, flanges, access doors etc shall not be measured seprately These shall be treated as part of duct work. (iii) Only external angle Iron/C channel duct support shall be measured and paid separatly.
All as per item No-68 above but 20 gauge galvanized sheet steel complete all as specified and directed by Engr-in-charge
M&L for replacement of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 600x400x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacment of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 500x400x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge
M&L for replacement of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 500x500x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacment of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 600x500x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacement of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 600x600x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacement of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 600x300x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacement of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 610x305x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacement of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 610x610x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacement of unsv flanged type EU-4 grade Filters, having aluminum MOC casing, HDPE+NW+HDPE Mesh fileter media , filtration effiency 90% down to 10 Micron, size 610x545x50mm, Air flow 1000CFM , complete all as specified and directed by Engr-in-Charge.
M&L for replacement of butter fly valve including taking out existing unsv butter fly valve and making good to the disturbed surface matching to existing specification (i.e. insulation of chiller/condenser pipe line) complete all as specified and directed by Engr-in-charge for the following dia:-
80 mm dia
100 mm dia
125/150mm dia
M&L for taking out existing Unsv scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR 175A, Max Oper-35A, thermally protected system, LP side (PS 25 bar, TS max 63oC TS min-35oC, Vol 31.oI) HP side (PS 27.8 bar, TS max 68oC TS min-35oC, Vol 2.oI), having lubricant Mineral Oil 160P, heater etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified and directed by Engr-in-charge. (Model No. SZ18554RC) Note:- Refrigerant gas shall be measured and paid in respective item.
M&L for taking out existing Unsv scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR 270A, Max Oper-58A, thermally protected system, LP side (PS 20 bar, TS max 53oC TS min-35oC, Vol 32.8I) HP side (PS 29.6 bar, TS max 68.3oC TS min-35oC, Vol 2.oI), having lubricant POE320SZ, heater etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified and directed by Engr-in-charge. (Model No. SY300A4MBB). Note:- Refrigerant gas shall be measured and paid in respective item.
M & L for taking out existing insulation & replace with new insulation 24 kg/cu mt density & cover with glass wool of 50 mm thickness & 26 gauge Alumunium clading complete all as specified & directed by engineer in Charge.
M&L for taking out existing Mild steel pipe & Supply Installation Testing & commissioning of Mild Steel cooling water piping 80 mm dia and of Calss 'C', cut to required length, and installed with welded joints, including all necessay fitting such as elbows, tees, bends reducers flanged support and as specification , complete all as specified and directed by Engr-in- Charge.
M&L for taking out existing Mild steel pipe & Supply Installation Testing & commissioning of Mild Steel cooling water piping 100 mm dia and of Calss 'C', cut to required length, and installed with welded joints, including all necessay fitting such as elbows, tees, bends reducers flanged support and as specification , complete all as specified and directed by Engr-in- Charge.
M&L for taking out existing & Supply installation , testing & commissioning of of PN 1.6 , 3 way modulating valve 100 mm dia for AHU,s chilled water coil application complete with motor actuator, thermostat, voltage transformer, flanges, nuts-bolts, gaskets duy insulated with 50 mm thick TF Quality EPS & covered with 12 mm sand cement plaster including Copper Power & controle cable of suitabe size complete all as specified, required and directed by Engineer in Charge.
M&L for replacement of Unsv display controler for 11 TR of central AC plant, Model No 11 TR HM I (F-30A) (With PR) and testing after replacement complete all as specified and directed by Engr-in-charge
M&L for replacement of Unsv μMVPD of central AC plant, Model No- EC, Type- MVPD, Range- 4-44 Amps, Aux Supply-230VAC, Special- 5 Sec curve MPD and testing after replacement complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable gauge cocks for pressure gauge complete all as specified and directed by Engr-in-charge.
Chaulya Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .