Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹50.7 L+₹10.1 L (24.9%)Admitted-Finance SITE OFFICE PTPS PANIPAT | PANIPAT | PANIPAT | HARYANA | L2 | Admitted-Finance | |
| 3 | Rejected-Technical 7 SUNDER NAGAR PTPS COLONY GATE NO 03 PANIPAT | PANIPAT | HARYANA | - | Rejected-Technical Documents not submitted in support of PQR despite given reasonable opportunities. | |
| 4 | Rejected-Technical H O 113 JHARLI METRO MARKET DISTT JHAJJAR HARYANA | JHARLI | JHAJJAR | HARYANA | - | Rejected-Technical Firm is not having experience as per PQR of e-NIT. |
| Sl No | Description | Qty | Unit | APEX PROJECTS L2 | Satyam Engineering L1 |
|---|---|---|---|---|---|
| 1.00Part-A: Lump-sum rates for Overhauling of Fans and its associated Ducting during forthcoming overhauling of Unit # 2 of 2x600 MW, RGTPP, Khedar, Hisar. | |||||
| 1.01 | A1: Total lump-sum rate for Main Scope of Work for Overhauling of Fans and its associated Ducting during forthcoming overhauling of Unit # 2 of 2x600 MW, RGTPP, Khedar, Hisar. (as per scope of work). | 1 | Job | 36,00,000 ₹36,00,000 | 35,85,780 ₹35,85,780 Lowest |
| 2.00Part-B Rates FOR THE PURPOSE OF VARIATION IN THE QUANTITY OF WORK FOR OVERHAULING OF FANs AND DUCTING OF 600 MW BOILER UNIT-II AT RGTPP KHEDAR HISAR. | |||||
| 2.01 | Servicing of seal air blower | 1 | No. | 2,500 ₹2,500 | 500 ₹500 Lowest |
| 2.02 | Repairing of duct by patch work of size above 1'X1' | 10 | MT | 15,000 ₹1,50,000 | 6,500 ₹65,000 Lowest |
| 2.03 | Repairing of duct by running meter welding | 50 | Meter | 300 ₹15,000 | 100 ₹5,000 Lowest |
| 2.04 | Repairing of duct by patch work of size upto 1'X1' | 15 | No. | 900 ₹13,500 | 200 ₹3,000 Lowest |
| 2.05 | Replacement of fabric expansion joint (ir-respective of width) (scope of work will be as per Annexure-I) | 300 | Meter | 2,500 ₹7,50,000 | 300 ₹90,000 Lowest |
| 2.06 | Replacement of metallic expansion joint (ir-respective of width) (scope of work will be as per Annexure-V) | 3 | No. | 15,000 ₹45,000 | 5,000 ₹15,000 Lowest |
| 2.07 | Complete Servicing of gates / dampers (scope of work will be as per Annexure-VI) | 4 | No. | 850 ₹3,400 | 500 ₹2,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹70,700
Closing Date
15 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
RAKESH HARSH
CE RGTPP Khedar Hisar
Overhauling of Fans and associated ducting during forthcoming overhauling of 600MW Unit-II RGTPP HPGCL Khedar Hisar
2025_HBC_483225_1
2025DE053485 AD6A 4824 891E 58F4878636D5712PGC
Open Tender
Power/Energy Projects/Products
Works
55 days
KHEDAR
As per attached tender document
2 documents required · 2 mandatory
₹1,180
₹70,700
Yes
14 Aug 2026
13 Nov 2025
18 Dec 2025
13 Nov 2025
15 Dec 2025
13 Nov 2025
A1: Total lump-sum rate for Main Scope of Work for Overhauling of Fans and its associated Ducting during forthcoming overhauling of Unit # 2 of 2x600 MW, RGTPP, Khedar, Hisar. (as per scope of work).
Part-B Rates FOR THE PURPOSE OF VARIATION IN THE QUANTITY OF WORK FOR OVERHAULING OF FANs AND DUCTING OF 600 MW BOILER UNIT-II AT RGTPP KHEDAR HISAR.
Servicing of seal air blower
Repairing of duct by patch work of size above 1'X1'
Repairing of duct by running meter welding
Repairing of duct by patch work of size upto 1'X1'
Replacement of fabric expansion joint (ir-respective of width) (scope of work will be as per Annexure-I)
Replacement of metallic expansion joint (ir-respective of width) (scope of work will be as per Annexure-V)
Complete Servicing of gates / dampers (scope of work will be as per Annexure-VI)
Laying of cooling water lines/ lube oil line upto 75 NB dia
Replacement of DE/NDE bearing of motor of ID/ PA Fans
Replacement of blades of ID Fan
Replacement of blades of FD Fan
Replacement of blades of PA Fan
Replacement of complete rotor assembly along with impeller of ID/FD/PA Fan including removal & re-fixing of the blades. (scope of work will be as per Annexure-III)
Servicing/overhauling & bearing replacement of complete bearing assembly along with impeller of ID/FD/PA Fan. (scope of work will be as per Annexure-IV)
Painting of hand railing, gate, beam, structure duct etc.
Note: Paint is in the scope of HPGCL
Replacement of bearings of Seal Air Fan
Replacement of impeller of Seal Air Fan
Man hour rate (including T&P, gas, consumables etc.) : Skilled labour/ welder
Man hour rate (including T&P, gas, consumables etc.) : Semi-Skilled labour
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.77 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_561226.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .