Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical Not Admitted |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
30 Aug 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
O/O SE Jorhat Circle (I), Jorhat
LIS from River Doyang in Bendit Pathar at Sarupani under SOPD-G for the Year 2021-22 (3 Points).
2022_ID_26589_1
JC (I)/Tech/E-Tender/2021-22/24
Open Tender
Civil Works – Lift Irrigation Schemes
Item Rate
180 days
Golaghat
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
Yes
₹1.2 L
Yes
26 Sept 2022
8 Aug 2022
30 Aug 2022
9 Aug 2022
30 Aug 2022
24 Aug 2022
Amount
Final Survey
Carrying out block contour survey of the commanded area covering stream, dong, channel, road etc. and the whole area considering square block system and spot system and spot levels are to be within 30 M x 30 M for preparation of contour including clearing light jungles, chaining, pegging holding staff, umbrella and compass lining etc. where required, complete as directed.
Supplying sal wooden peg of different sizes including pointing one end etc. complete as directed. Size = 5.0 cm x 5.0 cm x 60 cm
Supplying sal wooden hammer of of size 15 cm x 10 cm with 45 cm long & 5 cm wooden handle etc. complete as directed.
Controll Cabin
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing
CC work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone aggregate of size 13 mm to 38 mm including curing, bailing out water with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered).
Footing for Steps, Column Footing, Column
Slab & Steps
Beam Lintel Beams etc
RCC work in slab, abutment cap and above abutment, pier cap, pedestals, dirt wall etc. in proportion 1:1½:3 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including necessary curing, dewatering etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately)
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying, complete as directed
125 mm thick 1st class brick nogged wall in cement mortar in prop 1:4 including racking out joints curing etc. complete as directed.
12 mm cement plastering including clearing surface and curing complete as directed. In cement mortar 1:4.
65 mm thick traced flooring with cement concrete in proportion 1:2:4 with broken stone aggregate of size 6 mm to 20 mm over one 1st class brick flat soling including sand packing of the voids in between the bricks, watering, ramming properly where necessary etc. complete and 12 mm thick cement plastering. Finishing on top trowelling, altering, curing, complete as directed. (Brick soling to be paid seperately).
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (b) Using other ISI marked approved circular hollow section
Providing galvanized C.I. sheet roofing including supplying fitting and fixing necessary galved, screws / iron "J" hooks bolts and nuts and washers etc. complete as directed including cost of roof truss (measurement on net roof area) 0.63 mm thickness (24 B.W.G).
Providing 0.63 mm thick glaved ridging including suplying and fixing with necessary glaved. Screw washer etc. (23 cm lappin
Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint
Distempering two coats including painting two coats to batten with approved paint complete as directed.
Providing barge board of size 200mmx20mm with 1st class local Hollock/Bonsum Timber including fitting and fixing with necessary wood screws etc complete.
Drawal of HT Line for 11/0.43, 25 KVA Pole mounted Sub-Station including complete commissioning of the scheme
Surveying and finalising the suitable tapping point in existing nearby 11 kV line in consultation with APDCL and Departmental Officers, marking the alignment of the line considering Right of Way, Feasibility etc. as required and as directed For first 500Mtrs.
Jungle cutting including cutting of branches of trees and reclining Bamboos along the alignment of the overhead line providing clearance 1.5M either side and above the line as directed. Clearance must be ensured at the time of charging the line
Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ⅕th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed. (I) Refilling with Hard Soil 7.5 Metres
Supplying and erection of MS Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with Clamps, Nuts & Bolts duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed 75 mm X 40 mm X 6 mm X 2200 mm
Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed
Supplying and Erection of 11 kV HT Stay Set comprising of 19mm dia × 1.8 m Stay Rod, Anchor Plate, Bow, Thimble etc. including supply and erection of 7/10 SWG G I Stay Wire and 11kV Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m) to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm) and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed
Supply and erection of G I Stay Wire 7/10 SWG along with 11 kV Guy insulator, binding to existing 11kV Stay Set and the GI Pole Clamp, tightening to required extent as directed.
Supplying and Erection of Hardware Fittings (3u bolt) on existing MS / GI Channel Cross Arm with GI Nuts and Bolts for mounting 11 kV Disc Insulator 45 kN as directed
Supplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed
Supply and Erection of 11 kV Grade Aero Bunched Cable with 3(three) Power core, Stranded compacted, Circular Aluminium Conductor screened with black extruded semi conducting compound natural colour XLPE insulated core screened with black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC and one Bare messenger wire shall be stranded non-compacted circular aluminium alloy conductor. the cable should conform to IS:8130-1984, IS:398(Part-IV) 1994, IS:7098(Part-II) 2011 & IS:5831-1984 with up to date amendments. The job includes necessary Cable Joint, End Terminations, Anchor Clamp, Supension Clamps, Eye Hooks etc as directed by department. iii) 3 x 95 sqmm(P) + 1 x 70 sqmm (M)
Supplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. 400 Amps
Supplying and Erection of 3-φ 11 kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymeric insulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. (150 amp)
Supplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed 9 kV, 10 kA with Polymer body
Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed
Supply including Erection of 4 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latest amendments) with all standard accessories erected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc,, securing it on existing Channel firmly with necessary clamps, nuts & bolts . as required, and making necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra ) Capacity : 25 kVA, 11 kV/0.433 kV (4 Star Dyn)
(A) Cost including Supply of Transformer
B) Cost only for Erection (Transformer procured separately)
Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. 6 SWG G.I. Wire
Supply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed
Supplying including erection of powder coated LT Feeder Panel for 25 kVA DTR (800mm × 1000mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 63 A 415 V FP MCCB, making necessary connection through copper cable complete as directed.
Supply including Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 35 Sq mm × 3 core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of tren ch of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5cm + 7.5cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed
Danger plate suitable for 11KV line conforming to IS:2552/1963 of size 200mmX200mm
Providing Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed.
Testing and commissioning of the Substation alongwith obtaining necessary approval for charging from competent authority including payment of Inspection Fee, Arranging for Test Report etc. as required and as directed for following kVA Capacity
Liasoning with APDCL, Forest Department, Electrical Inspectorate etc. right from start till commissioning of the HT Line/ sub-station, preparation of all necessary documents like Agreement and Affidavit reqd. for power connection, obtaining No Objection Certificate from Forest Department where necessary to complete all arrangement for charging the installation as reqd. and as directed.
Testing and commissioning of the 11KV Line including making necessary inspection fee and obtaining charging approval from competent authority making requisite payment of Inspection Fee to the APDCL/ Electrical Inspectorate, arranging for Test Report etc. as reqd and as directed. upto 1 kM
Erection & Commissioning LT Whole Current Electronic Energy Meter including making necessary payment to APDCL for Meter Cabinet, Meter Security etc as reqd and as directed.
Load Security to be paid to APDCL (Approx.)
LT Controll Pannel
Supplying, fitting, fixing of LT Power Capacitor, 415V, AC, 3 Ph (single unit) of 6KVAR rating and making connection with Bus-bar in the existing panel. The capacitor is to be placed in existing platform.
Supplying, fabrication and erection of Iron Angle Stand for erection of LT Power Capacitor made of MS Angle of size 30 mmX 30mm X5 mm with 4 Nos of legs 400mm high and cross pieces having Bakelite Sheet horizontal platform as directed Size of Frame: 300mm
Supplying including fitting, fixing and connection of TPN Main Switch (SDFU- Switch Disconnector Fuse Unit) with HRC fuses, 415V AC, Open Execution, Panel Mounting type of following rating in already fabricated Control Panel Board housing , along with lugs, connecting cable and all other necessary materials as directed, 100 Amps
Supplying including fitting, fixing and connection of three pole 415V, AC 50 Hz Motor Protection Circuit Breaker (MPCB) with adjustable thermal and magnetic setting with rotary handle of following current/HP ratings in already fabricated LT Control Panel Board housing along with lugs, connection cable and all other necessary materials for connection as directed.
Automatic Star Delta Starter: Supply including fitting, fixing & connection of Automatic Star-Delta Starter in sheet steel housing for 3-ph, 415 V AC squirrel cage motor of following current rating including fitting, fixing of angle iron frame/clamps and all other necessary materials for connections as directed, 20 HP
Laying of PVC/XLPE insulated Armoured LT Power Cable 1.1KV grade with Aluminium conductor in open trench/ in air including fitting with necessary necessary clamps etc. in wall/pole /other support as reqd. and as directed. Size of Cable: 25 Sq.mm X3 Core for Starter Connection:
a)Cost of Cable
b)Laying & Connection
EARTHING Supplying and erection of Pipe Earth Station including supply of all materials with GI Pipe of following size perforated all over the body with 12mm dia hole at standard spacing with necessary reducing socket , locking arrangement with hinge cover plate, funnel, GI nuts& bolts etc with necessary enclosure on the top including excavation and refilling as directed.
40mm dia X2.5 Mtr long GI Pipe along with salt and charcoal
Supplying, laying and making connection of 6 SWG Copper Earth Wire making earth connection to Control Panel Board, Motors & Starters etc as directed.
SAFETY MATERIALS AS REQUIRED
Chequered Sheet (1.18M X 0.9M X 10mm)
Porcelain cut-out, 200 Amps.
Fuse wire 100 A
Rubber Hand Gloves for 11 KV Line work
Hand held digital Insulation Tester with LCD display with voltage ranges 50 V/100 V/ 250 V/500 V/ 1000 V and insulation
Manual Crimping tool with Dies 10 mm² to 95 mm²
11 KV Hook Stick with Fibre body 6 mtr long and of approved quality
Transportation of Safety materials from HQ to Site
Supply, Fittings & installation of Miscelleneous Materials as Required
Panel mounting front operated TPN switch 100 Amps
Aluminium lugs of best quality
a) 25 sq mm
b) 35 sq mm
emery paper
a) Rough
b) smooth
Waste cotton
Transformer oil
Guy insulator
11KV Pin Insulator
MS nuts & Bolts (Assorted size)
MS washer (Assorted size)
Soldering Flux
GI Wire 6 SWG
Stay wire 7/10 SWG
PVC Adhessive tape (steel grip) 20 mtr length
CT coil 100/5
Aluminium binding wire
Procurement of pump sets & Installation, Testing & Commissioning,priming system
Centrifugal pump set with 60/70 LPS minimum discharge at 10.35 Mtrs Head working efficiently at head range (7.62-13.71) Mtrs coupled with 20Hp induction Motor, Pump, Motpr, Starter should be of repited brand and as per IS specification.
Electric motor driven vacuum pump set, water ring type mounted on common base frame and coupled by means of flexible coupling capable of handling minimum 14 litre of free air per second (0.084 cubic metre per minute) and to produce minimum vacuum of 600 mm of mercury (approx.) coupled with 3 HP, 440/ 400 V, 3 ph, 50 cycle induction motor. The pump should have specific suction & delivery provided with vacuum gauge complete. Vacuum Pump set & Starter should be of reputed brand and as per IS Specification
Installation of Centrifugal Pump set (Horizontal Split casing type, size: 150 mm(suction) x 125 mm dia. (delivery) of 60 LPS minimum discharge at 13.00 Mt head coupled with 3 ph, 415 V, 50 Hz, 1450 RPM squirrel cage induction motor of 20 HP complete set. The job includes necessary transportation of pump set to the site and installation of C.C. block foundation in proper position with accurate alignment by means of foundation nuts and bolts complete with all works.
Fitting, fixing and laying of G.I. Pipes with Accessories: Laying, fitting, fixing and connection of suction pipe line for each pump set with 150mm dia. G.I. pipes of different length, fabricated G.I. pipes with different length, fabricated bends, tapper including foot valve for suction side. Reflex valve, sluice valve for delivery side of each pump set with 125mm dia. G.I. pipes with different length, bends, fabricated G.I. pipes with different length as per drawing. The joints should be with the best quality pipe joining sets of required size comprises of 60mm thick black moulded rubber gasket, necessary nuts, bolts and washer. Every joint should be leak proof and should be completed in all respect from foot valve to the pump flange for suction side and fr4om delivery flange is the water flow through at proper F.S.L for the delivery side. The pipes lines with accessories must be proper painting
Providing, fitting , fixing and erection of pipe supports for each pipeline at on interval of 3.00 Mtr. (approx) made of M.S. channel (ISMC 75) 1.50 Mtr. height with angle bracing erected on CC block of size 0.45mX0.30mX0.60m below ground.
Installation of Electric driven Vacuum pump set water type mounted on common base frame and coupled with flexible coupling capable of handling minimum 2.20 Lt of air/sec and to reduce minimum vacuum of 600 mm of Hg pressure with 5 to3 HP, 440V,3ph,50Hz induction motor set with starter (Amp range-7.5A) mounted on common base frame on suited C.C. base foundation bolts of required size. Also installation and connection of wall mounting type sub panel board ( readymade sheet enclosure with make)suitable for the motor of vacuum with necessary frame and clamps and fitted with the components, 1) MCB (3 ph,415 V,50 Hz,25 KVA, 16 Amp) 2) Voltmeter (0-500 V) 4) Electro switch for Voltmeter 3) Ammeter (0-25 Amp) 5) Induction lamp (R-Y-B) The job should be included connection of the components with the motor through the starter with best quality PVC insulation sheeted copper conduction cable of appropriate gauge.
Supply and compressing of graphite greased gland packing of reputed quality as required quantity around the rotating shaft of the pump set against the gland pressure plate to form a water tight seal and adjusting with the help of gland nut in order to accommodate continuous operation .
Laying and connection of cables such as Feeder cable, priming motor cable, lighting cable etc. ii) 25 sqmm x 3 ½ core
P.V.C. distribution system
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil
Supplying fitting fixing of P.V.C. pipe (IS 12818, 4kg/cm2 ) , joining pipes with relevant cement ,levelling , testing leakages etc. complete as directed .(Cost of earth work foundation trenches will be paid separately)
A)160mm dia
B)110mm dia
Supplying, fitting ,fixing , P.V.C. unequal Tee (Prince- brand)joining with pipes with solvent cement, testing leakages etc. complete as directed. Size: 160mm x 160mm x 110 mm .
Supplying, fitting ,fixing , P.V.C. Reducer (Prince- brand) joining with pipes with solvent cement, testing leakages etc. complete as directed. A) Size: 160mm x 110mm
Supplying, fitting, fixing, joining of PVC end cap fitting with solvent cement as per specification including local carriage, testing leakage etc. complete as directed. Size : 110mm
supply, laying & installation of delivery pipes & accessories including Surge Tank
Supply, fitting-fixing of Surge Tank of size 900 mm dia x 1250 mm long made of 4 mm MS plate with Raiser assembly of size 75 mm dia x 6.0 M long and S-bend of size 200 mm x 1600 mmL made of 4 mm MS plate including painting the above with one coat of synthetic enamel primer followed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified CC foundation by nuts & bolts of suitable size as per drawing & specification as directed.
SUPPLY, INSTALLATION, TRANSPORTATION/CARRIAGE & PAINTING OF DELIVERY PIPE & ACCESSORIES :
Fabricated GI bend , 100 mm x 900
Fabricated GI pipe, 100 mm dia x 3.00 M long
Fabricated GI pipe , 100 mm dia x 1.20 M long
CIDF Sluice valve, 100 mm dia
CIDF Reflex valve, 100 mm dia
MS nut & bolt (assorted size)
MS washer, assorted size
Rubber Gasket, 100mm dia
Black putty
GI Flange, 100 mm dia
Supporting Pillar
Earth work in excavation of foundation of canal structures in all types of soil as per design and drawing dressing the foundation, shoring, etc. removing the surplus spoils by head load to a safe distance from the working place and depositing required spoils in uniform layers dressing, watering, breaking clods to not more than 10mm cube with compaction complete as directed at site (including bailing out stagnant water where necessary). a. All type of soil except soil mixed with gravel and boulders For normal lead of 30m and lift of 1.50m
Soiling in foundation floor at all levels including filling interstices,ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately).
Centering and shuttering including propping etc. where necessary and removal of forms after completion of C.C. and R.C.C. works as directed complete (measurement to be taken on the face area timbered)
Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed.
12 mm thick cement plastering including clearing surface and curing complete as directed in prop. 1:4
Spout Chamber ( 15 Nos.)
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)
12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4
Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.
Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed. 110 mm / 90 deg
Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately). 110mm dia [ For outlet]
Bank protection work
Earthwork in trimming of side slope of river bank of the of the designed section in all types of soil and utilizing the same in filling up the river bank to the designed level etc. Complete as directed. (All types of soil except mixed with gravel and boulder)
Collection of hard broken stone of size 13 mm to 38 mm from blasted boulder free from dust and dirt and foreign materials including stacking at quarry site, complete as directed.
Collection of one man size 25 cm to 30 cm hard river boulder including stacking in measurable stacks of not more than 1.00 M height at quarry site and making payment of forest royalty etc, complete as directed.
Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed A) For Normal Road upto 25.00 KM
Labour charge for spreading hard river gravel/broken stone of size 13mm to 38mm to the required thickness including ramming, dressing the seat before laying the materials as directed with lead up to 30m & lift upto 1.5m complete as directed.
Labour charge for pitching with one man size boulder including dressing and ramming the seat to proper size and slope, pitching etc. with local carriage of boulders from a distance of 60 M with lift upto 3 M, complete as directed.
Construction of 1.00 M x 1.00 M rectangular boulder sausage including supplying of materials with 25 cm to 30 cm size boulders collecting from a lead of 25 KM encased in 15 cm mesh of 8G hexagonal wire netting and filling the voids between the boulders with stone not exceeding 18 cm in size tied with 8G galvanized tying wire at 30 cm apart, laid in position as directed including necessary local carriage of materials, paying necessary forest royalty including providing 1 (one) no. of jati bamboo horizontal runner along the top of the sausage with vertical bhaluka bamboo post 1.20 M apart driven at least 0.60 M below ground and tying with sausage etc, all complete as directed.. With river boulder
Boundary Wall
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. (a) In ordinary soil
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).
(C) Shuttering (Column)
Shuttering (Beams) with out props
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete (a) In proportion 1:4.
12 mm cement plastering including clearing surface and curing complete as directed. In proportion 1:4
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts).
Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed.
Appoach Road & PWD Road Crossing
Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed.
Collection of sand gravel (40% sand and 60% gravel of size 25 mm to 60 mm) free from dust and dirt including stacking in measurable stacks at quarry site and making payment of forest royalty etc. as directed complete.
Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed.
For 1st KM of quarry road
Normal Road upto 25 KM for 20 KM
Labour charges for spreading hard river shingles / sand gravels to required thickness over approach subway etc. including ramming, dressing the seat before laying the materials lead upto 30.00 M and lift 1.50 M. Complete as directed.
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing
CC work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone aggregate of size 13 mm to 38 mm including curing, bailing out water with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method ii) For Grading II Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. 2) Grading -III (A) By Manual Means
Interlocking concrete block pavement Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage. a) Including Edge block/ Edge restraints
Sign Board
Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed. (As per approved rate of SE)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .