| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC Reasonable lowest tenderer | |
| 2 | L2₹20.0 L+₹1.0 L (5.48%)Rejected-Finance 0 3 SHASTRI STREET FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L2 | Rejected-Finance Not Lowest tenderer | |
| 3 | L3₹20.6 L+₹1.6 L (8.49%)Rejected-Finance | L3 | Rejected-Finance Not Lowest tenderer | |
| 4 | L4₹20.9 L+₹2.0 L (10.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest tenderer |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
25 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (East ) Ferozepur Cantt
GE (East ) Ferozepur Cantt
PROVN OF 81MM MORTAR SIMULATOR ROOM AT 21 GRENADIERS AND CERTAIN MINOR WORKS OF E/M UNDER GE (EAST) FEROZEPUR CANTT
2022_MES_526476_1
8009/GE/E/FZR/22-23/E8
Open Tender
Civil Works
Item Rate
180 days
GE (East ) Ferozepur Cantt
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (East ) Ferozepur Cantt
₹37,000
Yes
15 Jul 2022
26 May 2022
28 Jun 2022
26 May 2022
25 Jun 2022
9 Jun 2022
Amount
B/R Works Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc for laying cables, pipes or for shafts wells cespits, manholes, pier holes etc n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
All as per Serl Item No 2 here in before but exe 1.5 m depth and not exe 3.0 m complete all as specified and directed
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in foundation, mass concrete filling in poles, sub base for floors etc complete all as specified and directed
M&L for Brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 complete all as specified and directed
All as per Serl Item No 05 herein before but built in cement mortar 1:4 complete all as specified and directed
M&L for formwork to sides of concrete foundations,footings,bases or column,raft and raft beams,sides and soffits (if any) of foundations and plinth beams and similar work,vertical or batter etc rough finished surface of concrete complete all as specified and directed.
M&L for formwork to sides of pillars,posts,struts,piers,columns and stanchions etc rough finished surfaces concrete complete all as specified and directed.
M & L for formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc rough finished surfaces of concrete complete all as specified and directed
M & L Formwork to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concretecomplete all as specified and directed
M & L Formwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide rough finished surfaces of concrete complete all as spd and directed.
M&L of TMT bars 10 mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia complete all as specified and directed
All as per item No 12 above but 6 to 8 mm dia complete all as specified and directed
All all as per item No 12 above but 5 mm dia and over upto and including 10 mm dia in stirrups spaces and binders complete all as specified and directed
M&L Reinforced cement concrete (M-25 Design mix) using 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies,deck slabs and in shelves and the like complete all as specified and directed.
M&L Reinforced cement concrete(M-25 Design mix) using 20mm graded stone aggregate as in foundations including rafts,footings,foundations beams ,bases of column etc complete all as specified and directed.
M&L Reinforced cement concrete (M-25 Design mix) using 20mm graded stone aggregate as in columns,pillers,piers,posts and structs etc complete all as specified and directed.
M&L Reinforced cement concrete (M-25 Design mix) using 20mm graded stone aggregate as in beams,cantilevers,bressummers,lintels over 1.5 m span complete all as specified and directed.
Returning filling in layers including leveling watering and well ramming in layers n.exc 25 cm thick in soft/ loose compelte all as specified and directed.
Removing surplus soil to a distance not exceeding 100 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as spd and directed.
Spreading and levelling not exceeding 25cm thick each layer including watering and well rammed complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in CM 1:6 on fair faces of brickwork/ concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brickwork or concrete surface finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces complete all as specified and directed
M&L for applying 3 coats of white washing on walls including preparation of surfaces complete all as specified and directed.
M&L for two coat of cement base paint over one coat of cement primer on walls including preparation of surfaces complete all as specified and directed.
M&L applying 3 coats of white washing on ceiling surfaces including preparation of surfaces complete all as specified and directed.
S&F Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one or more rebates incl lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint including hinges, hold fasts/lugs etc including making good jambs portion by providing plaster in CM 1:4 and finishes as per existing complete all as specified and directed.
S & F 35mm thick, 2nd class hard wood (Hollock), plain framed, panelled shutters, any number of panels, with lock rail and panel of 9 mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both face, size of rail & stile as per SI-1003 (Pt-I) kin seasoned and chemically pressure treated for anti termite treatment complete all as specified and directed
S&F Factory made box type steel window with side hung shutter including pintol hinges & 2 Nos 150 mm MS tower bolts on each shutter complete with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified including making good jambs portion by providing plaster in CM 1:4 and finishes as per existing complete all as specified and directed.
S&F Factory made box type steel window with side hung shutter including pintol hinges & 2 Nos 150 mm MS tower bolts on each shutter complete without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified , including making good jambs portion by providing plaster in CM 1:4 and finishes as per existing complete all as specified and directed.
M & L mild steel framed work of Fe 290 grade E-165 such as grills/guard bars with end of bars shouldered and /or riveted with steel/ventilator complete all as specified and directed.
S & F Factory made box type steel ventilaters fixed type complete with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed.
S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane complete all as specified and directed
S & F Galvanised mild steel wire cloath, 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed
S & F 250mm long MS Sliding door bolts plate type stove enameled black with bright bolt not less than 12mm dia with & including minimum of 6 bolts and nuts, 04 on bolt plate and 02 on staple plate complete all as specified and directed.
S & F Mild steel butt hinges, medium weight, cold rolled size 100 mm long complete all as specified and directed
S & F 200 mm long mild steel semi barrel tower bolts, open cover with sheet pressed barel, stove enamelled black with bright not complete all as specified and directed.
S & F 150 mm mild steel pressed handle oval type stove enameled black complete all as specified and directed.
S&F 300 mm Mild steel ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
M&L preparation of new steel surfaces of any description, over 10cm width or girth not otherwise described and applying two coats with synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M & L preparation of new steel surfaces of any description, over 10cm width or girth not otherwise described and applying two coats with synthetic enamel paint complete all as specified and directed
M & L preparation of new wooden or wood based surfaces of any description, over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint over a coat of pink primer including preparation of surfaces complete all as specified and directed
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base for floors etc complete all as specified and directed
M & L 50 mm thick PCC type B-1, 1:2:4 using 20 mm graded stone aggregate finished even and smooth without using extra cement complete all as specified and directed
M&L for brick hard core of gauge n.exc 63 mm deposited, spread and leveled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and directed
M & L 50mm thick for PCC 1:3:6 type C2 (with using 40mm graded stone aggregate) as in plinth protection/path, concrete surface finished even & smooth without using extra cement including construction joints complete all as specified and directed
M & L Rrendering 15 mm thick screed/cement plaster in CM (1:3) on RCC surface of roof/Brick walls using WPC as per manufacturer's instruction or not less than 3% by weight of cement which ever is more and finished fair and even the surface complete all as specified and directed ( Note :- WPC shall be measured separately)
Supply only integral water proofing compound complete all as specified and directed
M&L for laying APP based polymeric membrane 3mm thick with minimum weight not less than 3 kg/sqm, reinforced with non woven polyster fabric (wt not less than 160 gms/sqm) torching Joints/overlaps with a propane or a butane gas torch,laid with a minimum overlap of 150mm with thermo fusable finish laid/bonded over and incuding a coat of hot blown bitumen 85/[email protected]/sqm,over forced application bitumen primer @0.30 litres per sqm,including preparation of plastered surfaces of roof portion ,complete all as specified and as directed.
M & L Factory made machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60mm thickness , M-35 Grade with grey and no pigment over and inclding 25mm thick layer of fine sand and grouted with dry sand over and including 75mm thick brick hard core complete all as specified and directed
M&L for Continuous brick edging using full bricks of sub class "B" old size bricks with equal to width of Brick laid dry on end vertically including necessary earth work embeddingmbricks at required depth and tamping ground and removal of surplus soil to a distance n exe 50 meter complete all as specified and directed
E/M Works M&L for wiring with 1.5 Sqmm (nominal area), PVC insulated, FRLS multistranded, single core unsheathed, copper conductor calbes drwan through and including PVC condui with all accessories concealled in wall and fixed to ceilng etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, multi stranded, single core, copper cable green in colour as earth continuty wire connecting to common earth dolly including sunken boxes of suitable size fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/ fan/ bell point controlled by one, one way switch complete all as specified and directed
All as per item No. 53 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board, complete all as specified and directed.
All as per item No. 53 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on same board, complete all as specified and directed.
All as per item No. 53 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable complete all as specified and directed.
S&F Switch modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed.
S&F Switch modular type 16 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed.
S&F Socket outlet modular type 6A - 2 in 1,without shutter, 2 module, duly ISI marked, complete all as specified and directed.
S&F Socket outlet modular type 16A, 3 pin combined, 2 module, duly ISI marked, complete all as specified and directed.
S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed.
S & F fan regulator, electronic step modular type 120W capacity, of two module, single pole, duly ISI marked complete all as specified and directed
S&F Lamp angle holder (Plastic Ring), 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed.
S&F LED bulb of 9 watt, B22, 6500K complete all as specified and directed
S&F 20W, 6500 K, 4 feet LED Square tube light fitting, energy efficient fixed to wall/ ceiling etc complete all as specified and directed.
S&F LED sleeky bldg street light (Lens) fitting of 35 watts, 6000K, including GI bracket bend to shape made out of GI pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with MS clamps made of 25x3mm MS plate, duly painted with two coats of aluminium paint with nuts/ bolts/ washers and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 complete all as specified and directed.
S&F Ceiling fan 1200mm sweep, AC single phase 230 Volts 50Hz, including provision of flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan upto 1.5 mtr for giving connection and all hanging arrangement i.e. standard down rod, hanging clamp, with rubber real nuts bolts, spring washers and locking of splite pin, plastic canopy with screw compete without fan regulator and marking of MES nos with black synthetic enameled paint all as specified and directed.
S&F exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
S&F Sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB of 240V, 20 amps complete all as specified.
S&F Desert cooler electric driven single phase having nominal air flow cap of 4000 Cum/ hr, with working voltage 240V 50 hz, made of 20 guage sheet of ISI marked, size not less than 90x70x70 cm surface area from top and bottom, 68x54 cm from front grill size including Tullu pump with 4 nos piano type 5 Amp switch on front side inclduing one coat primer and two coats of synthetic enamel paint, inner tank coated with rust proof paint (steel body) with minimum volume of inner water tank is 80 Ltrs complete and thickness of tank should not less than 50 guage, fitted with copper winding electric motor complete all as specified and directed. Note:- Test certificate of electric motor from reputed brand i.e Crompton, Khaitan, Bajaj etc is mandatory required and submitted by contractor to concerned Engineer-in-Charge.
S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S. sheet, powder coated, partly embedded in wall, IP-43 protection, VTPN DB with 200 Amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof, suitable for incorporation of MCCBs/ MCBs, factory made, including thermal based release adjustable type 4 pole 63 Amps, 50 Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified.
M&L for Sub main wiring with two single core 2x6 sqmm PVC FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 6.0 sqmm drawn in and incuding PVC rigid conduit connected to main board complete all as specified and directed ( Note:- Two runs cable and one number earth wire and suitable PVC conduit shall measured together as unit length).
M&L for Sub main wiring with two single core 2x4 sqmm PVC FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 4.0 sqmm drawn in and incuding PVC rigid conduit connected to main board complete all as specified and directed ( Note:- Two runs cable and one number earth wire and suitable PVC conduit shall measured together as unit length).
S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, SPN DB with 200 Amps rated bus bar, 12 way, IP-43 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly partially immersed in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified.
S&F MCB SPN, 40A - 63Amps, 240 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SP, 6A-32 Amps, 240 volts, "B" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning complete all as specified and directed.
S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/ walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed.
Supply, laying and testing cable XPLE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 4 core complete all as specified. (Note:Excavation and earth work measured separately).
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified and directed. (Note :- 1 Excavation and earth work measured separately) 2Punned down thickness shall be measured.
S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified and directed. (Note:-Excavation and earth work measured separately).
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009)
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply & fixing PVC insulated flat twin core 4 Sqmm cable aluminium conductor flexible 1100 volts for connection street light fittings complete all as specified and directed.
S&F GI Bracket for street light fitting bend to shape made out of GI pipe light grade 32/40mm bore upto 1.2 mtr long etc complete with two sets of MS flat clamps of size 45 x 5 mm duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed.
Supplying , erecting and fixing Pre-stressed concrete poles 9 mtr long of cross section 102mmx172mm at top and 102mmx279mm at bottom Class 10 compluing with requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint in black and white strips each 30 cm wide each up to 1.5mtr high from coping over a coat of primer including numbering of poles complete all as specified
S & F pin type, porcelain, viterous, white brown or green insulator including mild steel spindle & nut, two galvanised iron washers, one galvanised iron nuts 100 mm height , 65 mm dia for 1100 volts complete all as specified.
M&L Cross arms bracings, supported clamps and back plates, fabricated from structual steel sections, drilling holes for bolts, in any shape or size as indicated or directed and including necessary welding bending cold or hot inclusive of nuts, bolts, washers and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed
M&L Cement concreted 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed
M&L Cement concreted 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed
Supply, installation,commissioning and testing of submersible pump set Multi stage (As per mfg design stage) electric driven 2900 RPM of capacity not less than 780 LPM at not less than 90 mtr head water lubricated suitable for 200/ 250mm bore and 150 mm dia discharge pipe coupled with squirrel cage induction electric motor 3 phase 415 volts of capacity not less than 30 HP having CI casing & Gun Metal impeller fitted with delivery pipe etc as reqd at site complete all as specified and directed Make of Pump and Motor :- Crompton 8W5L30D-W /Kirloskar or KSB.
S&F Flat Three Core PVC Insulated & PVA Sheathed Industrial Cable for Submersible Pump Sets ISI marked conformed to IS 694, of required length from panel to star delta starter and motor of Submersible pumping set installed complete all as specified and directed
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos, 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
M&L Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed
Supply, installation and testing of maintenance free, ready capsule, pipe-in-case, special chemical type earthing system for distribution network. The technical specification is designed keeping in view following advantages :- (i) In this type of earthing electrode, the electrode, the surrounding enhancing material bonding with electrode and the case are in pre-fabricated, ready to use form so that on-filed mal-practice in form of less digging of earth pit, less earth enhancement filling, improper watering at site, can be overcome. This makes the quality check very convenient. (ii) Due to pre-fabricated, ready to use methodology, no on-field wastage of earth enhancement material is done. (iii) This earthing system shall be the relevant standard specification unless otherwise specified, in line with the requirement of any of the latest applicable standard. The applicable amendments as and when imposed shall be appicable.
item 95 Contd... This maintenance free earthing system shall be based on ready capsule type, pipe-in-case technology concept in which, One Galvaniszed hollow pipe (Electrode) is kept inside the Galvanized Perforated cage. The space between the electrode and cage shall be filled with a specially developed earth enhancement material (EEM) made up of Conductive Cement, Graphite carbon powder, Sodium montmorillonite/ Sodium Bentonite, Hydrous aluminum silicate etc. to reduce earth resistivity. The system shall be almost maintenance free and require no periodic or scheduled maintenance for an expected period of 15 years. There shall be no requirement to add any other chemical or water at any time after initial installtion because of hygroscopic chracteristic of earth enhancement operations in the actual service conditions at site. (a) Earth Electrode 3000mm Long : The earth electrode is the main component of the earthing
Item 95 Contd.. system which is meant for collecting, releasing and discharging earth leakage and fault currents. The earth electrode should be ready capsule type made with Pipe-in-Cage (PiC) technology concept. It includes the hollow MS pipe, as a primary electrode shich should have IS marking as per IS:1161-1979. For effective life of the earthing system, the whole shall be provided a zinc coating up to 150 microns through hot dip process. The zinc used for galvanizing should follow Zn 98.0 Grade as per IS: 13229-1991 and process and measurement of hot dip galvanizing should be as per IS:2629. The outer cage of GI pipe shall be provided with maximum 3.5 mm dia holes and shall be hot dip galvanized with minimum 80 microns. (b) Primary Electrode : (i) Length (L) : 2900 mm (pipe) + 100 mm (terminal) = 3000 mm (Min), (ii) Outer Diameter : 48 mm (hollow) (Min), (iii) Thickness : 3.2 mm (Min), (iv) Weight of electrode : To be followed according to limit specifies in IS. (c) Perforated Cage : (i) 2890 mm x 150 mm for 3000 mm Electrode (Min), (ii) Circular Hole Size for cage- 3.5 mm dia or lesser, (iii) Thickenn of Net- 15 mm (Min) with hot dip galvanized.
Item 95 Contd.... (d) Terminal : Each Earth pipe must be provided with a connection terminal facility as shown in drawing by pressing of 100 mm at the top side of the pipe to form a strip having dimensions as mentioned/ specified shall be provided in the pressed portion of the top side of pipe. (e) Electrically Insulated Enameled Paint Coating : As shown in drawing No. GPRD-17, the electrically insulated enameled paint coating has to be applied on the 150 mm length of electrode immediate after the compressed portion of the electrode (terminals). Also, optionally PVC cap of appropriate die-electric strength can be provided to prevent the flow of current in the upper portion. The enameled paint coating should have minimum dielectric strength-20 Kv/mm and min. 4 coat should be applied to the surface of electrode. This is done in order to prevent the danger to the living being from step potential. (f) Zinc coating : The earth electrode consists of one mild steel pipe with provision of connections at top end as shown in the attached drawings No. GPRD-17. The entire electrode shall be hot dip galvanized with at least 150 microns over all
Item 95 Contd.. surfaces without leaving any point of the electrode un-galvanized and cage shall be hot dip galvanized with at least 80 microns in accordance with IS 4736: 1986.The process of hot-dip galvanized shall be followed as per IS: 2629. For uniform distribution of fault currents, an earth electrode must be cylindrical shape. (g) Short Time Current Rating : The earth electrode shall be capable to withstand minium 20 KA (rms) short time current for 1 sec. (h) Earth Conductivity Enhancement Material : It shall be placed between primary earth electrode and perforated cage to improve the conductivity of earth electrode & ground contact area. Earth enhancement material (Back fill compound) shall be according to IEC 62561-7, and superior conductive material that improves earthing effectivess especially in ares of poor conductivity such as rocky ground, sandy soil & areas of moisture variation with different strata. The expected composition of the compound is as under :- (i) Earth enhancement back filling compound composition with max permissible tolerance of +/- 10% in each content. (a) Conductive Cement- 15%,
Item 95 Contd.. (b) Graphite Carbon powder- 45%, (c) Sodium montmorillonite/ Sodium Bentonite Powder- 30%, (d) Hydrous aluminum silicate- 10%. Max permissible limit of Salt content is below 2%. The Sulphur content in the back-fill compound shall not be more than 2% in any case. All the component used in the mixture shall be having mesh size at least 200 mesh. (ii) The earth enhancement material/ backfill compound shall be highly conductive compound, maintenance free. The watering shall be required at the time of its installation ony. No re-charging with water, salts or any other chemical shall be required and it shall maintain almost constant earth resistance during its life cycle without manual watering. (iii) It must set firmly and should not dissolve or decompose or otherwise pollute the soil or the local watertable. (iv) It should have capacity to retain more than 10% moisture at 105 degree C. Test certificate for the same from CPRI/NABL approved govt supported laboratory shall be submitted. (v) Material shall be non-toxic, non-reactive, non-explosive & non-corrosive. It shall not cause burns, irritation to eye, skin etc.
Item 95 Contd... It shall not pollute the soil or local water table & shall meet environmental friendly requirements for landfill. (vi) It should have better hygroscopic properties to absorb moisture. It should absorb & release the moisture in the dry weather condition and help in maintaining the moisture around the earth electrode. Material shall be thermally stable between temperature ranges of -10 degree C to 60 degree C. Material shall not decompose or leach out with time. (vii) Material shall not decompose or leach out with time. The leach test shall be tested as per IEC 62561-7, Clause 5.3 at National Accreditation Board for Testing and Calibration Laboratories (NABL). (viii) Sulphur Determination test and Corrosion Test- As per IEC 62561-7, clause 5.3 & 5.5 respectively. (ix) It is preferable that the resistivity of the backfill compound shall not be higher than 0.20 Ohm, when it is tested with 4 electrode method using a soil box having cross section area of 4 cm x 3.2 cm= 12.8 Sqcm and keeping the electrodes at a distance of 12.8 cm in a soil box. The supplier shall produce the facility of soil box for testing.
Item 95 Contd.. (x) It should expand & swell considerably & remove entrapped air to create strong connection and bond between earth electrode & soil. (xi) It should diffuse in to the soil poress & create conductive roots enlarging conductive zone of the earthpit. (xii) It should be an alkaline in nature with pH value of >7 & <9Test certificate from NABL approved govt supported laboratory to be provided for the compound so designed.
Marwaha Builders
M/s G N Const. Co.
A N CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .