Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.3 L+₹2.8 L (8.78%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.7 L+₹10.2 L (31.6%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹42.8 L+₹10.4 L (32.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹43.5 L+₹11.1 L (34.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Mahesh Enterprises L4 | M/s. Kansal Construction Co. L6 | Laxmi traders L5 | J S CONSTRUCTION CO L1 | shakti construction L2 | SM CONSTRUCTION COMPANY L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge | 280 | Sqm | 10 ₹2,800 | 10 ₹2,800 | 100 ₹28,000 | 9 ₹2,520 | 50 ₹14,000 | 5 ₹1,400 Lowest |
| 2.00 | M&L for Vitrified Ceramic tiles light shade/dark shade /double charge/ ultracharged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge. | 200 | Sqm | 880 ₹1,76,000 | 800 ₹1,60,000 | 800 ₹1,60,000 | 935 ₹1,87,000 | 790 ₹1,58,000 Lowest | 950 ₹1,90,000 |
| 3.00 | M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thick as in levelling course ,finished surfaces even and rough to receive floor finish complete all as specified and directed by Engr-In-Charge. | 275 | Sqm | 180 ₹49,500 | 300 ₹82,500 | 200 ₹55,000 | 22 ₹6,050 Lowest | 120 ₹33,000 | 150 ₹41,250 |
| 4.00 | M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces complete all as specified and directed by Engr-In-Charge. | 5 | Sqm | 880 ₹4,400 | 800 ₹4,000 | 780 ₹3,900 | 800 ₹4,000 | 720 ₹3,600 Lowest | 950 ₹4,750 |
| 5.00 | M&L for vitrified ceramic tiles 9 to 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm th screed in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge. | 75 | Sqm | 880 ₹66,000 | 800 ₹60,000 | 780 ₹58,500 | 790 ₹59,250 | 690 ₹51,750 Lowest | 750 ₹56,250 |
| 6.00 | M&L for cement concrete1:2:4 type B-2 (using 40mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed by Engr-In-Charge. | 1 | Cum | 5,000 ₹5,000 | 4,000 ₹4,000 | 3,900 ₹3,900 | 4,500 ₹4,500 | 3,200 ₹3,200 | 2,600 ₹2,600 Lowest |
| 7.00 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe410 (Gde E-250 quality-A) complete all as specified and directed by Engr-In-Charge. | 500 | Kg | 90 ₹45,000 | 90 ₹45,000 | 80 ₹40,000 | 35 ₹17,500 Lowest | 90 ₹45,000 | 120 ₹60,000 |
| 8.00 | Dismantling plain corrugated steel sheeting any gauge thick ness including Nainital and similar pattern complete all as specified and directed. | 50 | Sqm | 10 ₹500 | 100 ₹5,000 | 100 ₹5,000 | 12 ₹600 | 10 ₹500 | 5 ₹250 Lowest |
| 9.00 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour (decided by EIC) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-In-Charge. | 200 | Sqm | 650 ₹1,30,000 | 600 ₹1,20,000 | 550 ₹1,10,000 | 300 ₹60,000 Lowest | 590 ₹1,18,000 | 550 ₹1,10,000 |
| 10.00 | M&L for two coats of synthetic enamel paint over one coat of red oxide, zinc chrome primer on steel surface including preparation of new surface of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed by Engr-In-Charge. | 50 | Sqm | 40 ₹2,000 | 60 ₹3,000 | 40 ₹2,000 | 45 ₹2,250 | 40 ₹2,000 | 30 ₹1,500 Lowest |
Tender Value
₹43.7 L
EMD Value
₹87,340
Closing Date
4 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
ADDN ALTN TO TRISHUL HALL OF HQ WAC BLDG AT SUBROTO PARK
2025_MES_712780_1
GE/SP/TOKEN-04/2025-26
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹87,340
Yes
21 Aug 2025
5 Jun 2025
7 Jul 2025
5 Jun 2025
4 Jul 2025
20 Jun 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M&L for Vitrified Ceramic tiles light shade/dark shade /double charge/ ultracharged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thick as in levelling course ,finished surfaces even and rough to receive floor finish complete all as specified and directed by Engr-In-Charge.
M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces complete all as specified and directed by Engr-In-Charge.
M&L for vitrified ceramic tiles 9 to 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm th screed in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge.
M&L for cement concrete1:2:4 type B-2 (using 40mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed by Engr-In-Charge.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe410 (Gde E-250 quality-A) complete all as specified and directed by Engr-In-Charge.
Dismantling plain corrugated steel sheeting any gauge thick ness including Nainital and similar pattern complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour (decided by EIC) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-In-Charge.
M&L for two coats of synthetic enamel paint over one coat of red oxide, zinc chrome primer on steel surface including preparation of new surface of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed by Engr-In-Charge.
M & L for complete removal of existing roof treatment (Mud puska, Cement Tiles, bricks or Old APP Roof treatment and vegetation from root) including bedding layer in cement mortar/Mud and disposed from MoD land complete all as specified and directed by Engineer-in-charge.
M&L PCC 1:2:4 type B1 (using 20mm graded aggregate stone aggregate) mixed with 3.00% liquid water proofing compound of weight of cement laid 25 mm thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gms polestar non-woven fabric with scratched tool before finishing roof surface. When the concrete surface is still green, 10 mm thick 1:4 cement plaster shall be laid, the roof surface shall be thoroughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface, one coat of approved bituminous primer having density in the range of 0.87 to 0.89 / kg at 25 degree and viscosity of 70 to 160 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied. APP membrane shall be laid on primed surface torch application method after allowing 24 hours of primer to dry. Laying of APP membrane shall be commenced at the lowest level and worked upto the crest. APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with butane torch complete all as specififed and directed. Note :- This treatment shall be done by the approved authorized applicator. Guarantee of treatment shall be for 10 years from the date of completion. (ii) Independent testing of membrane for the approval technical parameters specified here in after shall be carried out by the approved laboratories like National test house any other Govt approved laboratory having facilities for the testing of membrane.
M&L for 2 coat of water proof aluminium paint incl preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed by Engineer-in-charge
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. Raking out joints ,hacking for key and scrubbing down with water including removing debris out site MOD land complete all as specified and as directed by Engr-in-Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished surfaces even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces (Cement mortar 1:6) finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M&L for rendering 5mm thick cement mortar (1:3) as in ceiling, soffit of staircase, chhajjas facia etc including cement slurry etc complete all as specified and as directed by the Engineer-in-Charge.
M & L for complete removing existing treatment, old decorated surfaces of walls and ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. including cornices, pilasters etc. (Plastered or unplastered surfaces) and applying two coats of plastic emulsion paint (Coloured as directed by EIC), over 2mm thick wall care putty , complete all as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from external surfaces of walls by brushes and washing down and stopping of surface and levelling / edging the disturbed portion plane/edges using necessary filling compound of putty to obtain smooth/regular/even finish surface with using of sand paper etc and prepare surface , applying two coats of exterior weather proof (coat) paint on plastered/concrete surfaces of walls, paths , etc., over a coat of cement base paint primer complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 75 mm bore PVC (SWR) pipe single socketed any length with rubber ring joints laid in trenches or in floor complete all as specified and directed by Engr-In-Charge.
S&F 75mm bore pipe PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid,bedded and pointed in any mortar complete all as specified and directed by Engr-In-Charge.
M&L for 18-20mm thick granite slab (Z Black or as directed by EIC) on top of cooking platform, bar counter and similar work including cutting polishing rounding on edge etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding and polishing complete all as specified and directed by Engr-In-Charge.
M&L for 18-20mm thick Granite (Z Black or as directed by EIC) work (table rubbed and polished) for wall lining (veneering to wall with any height) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting polishing rounding on edge etc machine cut, bedded, jointed with grey cement slurry, pointed with white cement with admixture of pigment to match the shade of granite stone and holding with brass screw complete all as specified and directed by Engr-In-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engr-In-Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) thickness 1mm or 2mm thick sheet as directed by GE and rolling it over circular columns , rectangular columns etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the frame with necessary accessories & stainless steel dash fasteners, stainless steel bolts, Knob and chain etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engr In Charge.
Demolition of wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/ slabs/ blankets/board fixed in aluminum door or partition, any thickness, including cover fillets & framed work if necessary complete all as specified and directed by Engr-In-Charge.
M&L for WPC (Wood Polymer Composite) plank / Charcoal plank 3D profile as directed by EIC for wall panelling of fixed over PVC board base material, pasting as per manufacture direction to mild square tubular steel frame work made out of MS Hollow section of size 25mm x 15mm x 2mm spacing 01 meter on both side frame work shall be fixed in wall with the help rawl plug and required length of screws and MS work shall painted with one coat of Red oxide primer for wall panelling, complete all as specified and directed by Engr-In-Charge.
M&L for PVC profile for wall paneling of size 23cm wide, 8mm over all thickness and 01mm wall thickness fixed with screw to mild square tubular steel frame work mad e out of MS Hollow section of size 25mm x 15mm x 2mm spacing 01 meter on both side frame work shall be fixed in wall with the help rawl plug and required length of screws and MS work shall painted with one coat of red oxide primer for wall panelling,complete all as specified and directed by Engr-In-Charge.
S&F 5mm thick ACP wall cladding sheet in colour as directed by Engr-in-charge fixed on MS frame . The size of each MS frame panel not exc 1.5sqm. MS frame to be fixed on walls, chajja , ceilings and facade with Min 08 Nos GI fastener 5" long per 1.5 sqm, including all necessary repairing work as reqd, two coat of synthetic enamel paint over one coat of red oxide primer, including weather sealing sealent, masking tape, including cutting of V groves to fixing moulded ACP sheet self-tapping screw complete all as specified and directed by Engineer-in-Charge.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors,windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings complete all as specified and directed.
S & F Anodised powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed
S&F for 4.8 mm thick tinted sheet glass, fixed to aluminium frame work in panels in each pane, complete all as specified and directed.
M&L for 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber/aluminium frame work complete all as specified and directed.
S&F for 150 mm aluminium powder coated, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm long extruded aluminium alloy anodised powder coated handles fabricated type complete all as specified and as directed by the Engineer-in-Charge.
S&F Butt hinges of size 100mm length, extruded aluminium alloy, powder coated with hinges pin, medium grade complete all as specified and directed by Engr-In-Charge.
M & L for brick work with sub-class `B' bricks old size, straight or curved on plan exceeding 6 meter mean radius built in cement mortar 1:4 complete all as specified and directed.
S&F solar control film 50 micron thick reflective type with new themes as instructed by Engineer -in- Charge and sticked to glass panes as per instructions of manufacturers complete all as specified and directed by Engr-in-Charge.
S&F 12mm thick Toughned glass as in hinged doors, partitions, sliding doors, automatic doors and similar work of approved brand and manufactures, including cutting to shape, drilling holes required, including Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, complete all as specified and directed by Engr-in-Charge. Note:- Rate included all nessesry fitting and frame work for glass fitting, provision of top and bottom pivots, S/S handle, hinges, double action floor spring, stoppers etc. complete all as specified and directed by Engr-in-Charge.
M&L for multilayer POP false ceiling in steps (in layers) as per drawing and as directed by GE at site with horizontal and vertical GI frame work including GI wire mesh and fiber/mesh reinforcement as required including putty work for finishing smooth .painting with plastic emulsion paint in two coats over primer over finished pop surface with suitable arrangement for spot light /ceiling light as per drawing all as specified and driected by engr-in-charge.M&L for 10mm thick plaster of Paris ceiling (Gypsum anhydrous) to sunk or raised moulding to flat surface over metal frame work incl reinforced with G.I. wire mesh & Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre & Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. Note :- Unit quoted rates shall includes for taking down electrical fitting and refixing the same if required
S&F in repair for 10-15mm thick exterior PVC wall cladding (Jalli) sheet of medium denasity in colour white or as directed by Engr-in-charge with compterised numerical control (CNC cutting) as directed, fixed on MS frame. The size of each panel not exc 1.5sqm. MS frame to be fixed on walls, chajja and fasad with GI fastener 5" long per 1.5 sqm, including all necessary repairing work as reqd, two coat of synthetic enamel paint over one coat of red oxide primer, including weather sealing sealant, masking tape, including cutting of V groves to fixing molded PVC sheet with SS self-tapping screw complete all as specified and directed by Engineer-in-Charge. Note:- Work to be carried out up to four story bldg with MS scaffolding 2. MS frame should be fixed on wall after painting.
Taking down frame or Chowkhats (without taking off shutter from the frame ) of any description not exc. 1.50 Sqm and making surface good with CM 1:4 each complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each,incl removing complete and making good after fixing of new chowkat to match existing finish all as specified and directed by Engr-In-Charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 /65x125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibbers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed by Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners not paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F for Butt hinges of stainless steel 100mm size Heavy type complete all as specified and directed by Engr-in-Charge.
S&F for 150mm long stainless steel handles, fancy type, fabricated type. complete all as specified and directed.
S&F for 200 mm stainless steel, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for Brass Mortice lock, vertical type, size 100mm 4 levers vertical with fancy handle (as decided by EIC) complete all as specified and directed.
S&F in Door closer hydraulically regulated Aluminium (Die cast) body design No-3 universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed. Complete all as specified and directed by Engr-In-Charge.
S&F for door stopper of of brass body and tongue with hard drawn steel spring, (140mm size), complete all as specified and directed.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for Point wiring for one light point controlled by one SP switch using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade (FRLS),ISI-694 marked in and including heavy duty, PVC concealed conduit after cutting,chasing the wall etc and making good of disturbed surface, including all accessories etc, heavy duty ISI marked, including mild steel sunken boxes with earth dolly duly powder coated suitable for modulater plates of required size, covered with modular plates, suitable for modular switches, sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) (FRLS) single core cable as earth continuity conductor to common earth and connecting to earth dolly. (Note- Modular Switch and sockets will be measured and paid seperately).
All as per item No 58 here in before but for one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No 58 here in before but For one bell point controlled by one bell push switch
All as per item No 58 here in before but for one 3 pin socket out let, 6 Amps on same board
All as per item No 58 here in before but for one 3 pin socket out let, 6 Amps on Independent board
All as per item No 58 here in before but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including Single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire 2.5 sqmm FRLS (Only one 15 Amp point will be in one circuit)
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A -3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular switch 1 way 16A ,1 module suitable for 240 Volt AC complete all as specified and directed by Engr-in- Charge.
S & F Modular Socket, 16A -3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Electronic modular Fan Regulator rotary flush step type 120 watt, 2 module , 240 volt 50 Hz AC complete compatible with BLDC fans. Complete all as specified and directed
S & F Bell push Modular flush type 6 Amps suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ding dong bell AC 230 volt single pole complete all as specified and directed
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Taking down old unsv MCCB/MCB DB of any size. Complete all as specified and directed
Supply and fixing MCB distribution board with Bus bar 200A neutral link ,earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type concealed in wall complete all as specified and as directed by Engineer-in-Charge. Note :-(i) MCB shall be measured and paid seperately. (ii) cutting chasing and making good to existing surface also included in the unit quoted rate of item.
Supply and fixing load line vertical distribution board made out of CRCA sheet,double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP incomer MCCB of 160 Amps complete all as specified and as directed by Engineer-in-Charge. Note :-(i) MCB shall be measured and paid seperately. (ii) cutting chasing and making good to existing surface also included in the unit quoted rate of item.
Supply and fix of fixed adjustable type, 3 pole MCCB 125 Amps,Ics=100%Icu, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series complete all as specified and directed by engineer-in-charge.
S&F MCB SPN 32 Amps 10 KA, 240 volt 'C' Series complete all as specified and directed by engineer-in-charge.
S&F MCB TP 25 to 63 AMP 10 KA, 240 volt 50 HZ 'C' Series complete all as specified and directed by engineer-in-charge.
S&F 3 pin plug top 15 Amps complete all as specified and directed by engineer-in-charge.
Taking down of light fittings of any wattage complete all as specified and directed.
S&F surface mounted round shape 600 mm dia and 60mm thick, 50 watt 220 volts AC, as per existing fitting fixed in trishal hall , metal housing ,powder coated with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED light including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F surface mounted round shape 12 watt 220 volts AC, metal housing ,powder coated with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED light including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F focus light round shape LED 12 watt 220 volts AC with high efficiency PMMA diffuser suitable for roof ceiling/wall including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F warm white LED light fitting with high output diffuser 2 feet, 10 watt 220 V AC, 3500 K decorative type with driver holder and LED lamm including all connection upto ceiling rose complete all as specified and directed.
Taking down unserviceable submain wiring of alluminium two/three/four runs of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified and complete all as specified and directed by Engr-in-Charge.
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated and unsheathed FRLS cable multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated unsheathed FRLS cable 1100 volt grade,IS :694 marked,drawn through non metallic rigid PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) concealed in wall with all accessories such as bend ,elbows,tees etc. NOTE - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable(earth wire) and one run of PVC conduit will be measured as one unit for payment purpose.
All as per item No 86 here in before but but size of wire is 6 sqmm single core
All as per item No 86 here in before but five runs of 10.0 sq. mm single core
Taking down including disconnecting the electric connection of ceiling fan with dismantling blades,greasing and over hauling complete all as specified and directed by Engr-in-Charge.
Hanging / fixing only ceiling fan received from item No 89 above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose carry out painting complete all as specified and directed by Engr-in-Charge.
Dismantling including disconnecting the electric connection for split AC 1.5/ 2.0 TR indoor and outdoor unit and deposited in the store of AGE E/M complete all as specified and directed
M&L for Servicing,Installation,connecting of Split AC 1.5/2.0 TR received from item No 91 including gas charging if required and testing upto satisfaction of Engineer in charge Complete all as specified and directed. Note: Gas charging and minor parts replacement required at site also included in the unit quote rate of item.
S&F in replacement refrigerant line copper tube1/2" bore incl insulation of AC pipe complete all as specified and directed.
S&F in replacement refrigerant line copper tube 1/4" bore incl insulation of AC pipe complete all as specified and directed.
Supply & Fixing in replacement of PVC pipe of size 20 mm dia fixing on wall by using clamps and screwing including necessary tee, collar ,bend,socket etc complete all as specified and directed.
Supply & Fixing in replacement of flexible thredded pipe from indoor unit to main line size of 15/20 mm dia , fixing on wall by using clamps and screwing complete all as specified and directed.
M&L for Design, supply, install, testing and commissioning factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 600 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch gear, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 Hz, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: (a) ON Load change over switch 400 amp 4 pole -01No (b) Incoming MCCB 400 Amps 4 Pole, 36 kA, Ics=100%Icu- 1 No. (c) Outgoing MCCB 160 Amp 25 KA 3 pole ,Ics=100%Icu-02 Nos (d) Outgoing MCCB 125 Amp 25 KA 3 pole ,Ics=100%Icu-03 Nos (e) Outgoing MCCB 63 Amp 16 KA 3 pole ,Ics=100%Icu-01 No (f) Digital Multifunction Meter to measure V, A, F, PF, KWh including CT complete with all electrical connection - 01 No (g) LED type Phase indicator lamps (R, Y, B) with Control MCB 6 Amps SP- 1 Set Note : (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT and electrical connections complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 5000 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED.
M&L as in repair for Design, supply, install, testing and commissioning factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 600 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Multi Function meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: (a) Incoming MCCB 400 Amps 4 Pole, 36 kA, Ics=100%Icu- 1 No. (b) Outgoing MCCB 160 Amp 25 KA 3 pole ,Ics=100%Icu-02 Nos (c) Outgoing MCCB 125 Amp 25 KA 3 pole ,Ics=100%Icu-02 Nos (d) Outgoing MCCB 63 Amp 16 KA 3 pole ,Ics=100%Icu-01 Nos (e) Digital Multifunction Meter to measure V, A, F, PF, KWh including CT complete with all electrical connection - 01 No (g) LED type Phase indicator lamps (R, Y, B) with Control MCB 6 Amps SP- 1 Set Note : (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT and electrical connections complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 5000 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED.
Supply Laying and testing of cable XLPE insulated armoured heavy duty under ground 1100 volt grade with stranded aluminium conductor of 240 Sqmm 3.5 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and directed.
Supply Laying and testing of cable XLPE insulated armoured heavy duty under ground 1100 volt grade with stranded aluminium conductor of 185 Sqmm 3.5 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and directed.
Supply Laying and testing of cable XLPE insulated armoured heavy duty under ground 1100 volt grade with stranded aluminium conductor of 95 Sqmm 3.5 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for etc complete all as specified and as directed by Engr-in-Charge.
Returning, filling of soil in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and directed by engineer-in-charge.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by engineer-in-charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8 cm deep before laying the cable and 15 cm deep after laying the cable i.e total 23 cm) complete all as specified and directed by engineer-in-charge.
Supply and laying un-reinforced precast concrete cable cover Class LV ,Type I ,flat size 250mm x 150mm x40 mm laid in trenches as protection to cable complete all as specified and as directed by Engr-in-Charge.
Taking out old unserviceable LT under ground cable of any type/ size from trenches, pipes & poles complete all as specified and directed by engineer-in-charge..
Supply and fix White cover plate with frame,1 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,2 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Metal flush box 1 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Metal flush box 2 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 32A - 3/5 pin 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular MCB SP 20 Amps 10 KA, 240 volt 1 module all as specified and directed by Engineer-in-charge.
Supply installation commissioning testing of tripod earthing complete with copper bonded earthing electrode chemical earthing system outer electrode dia 25 mm and 3 mtr long tightly filled with crystalline conductor mixture 250 microns copper coated along with bag of back bill compound 50 kg buried directly in the ground (earth pit not less than 2.25 meter deep below ground level) connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts,nuts,check nuts and washers and connecting earthing test point ,including CI covers ,frame and PCC (1:3:6) type C-2 using 20 mm graded stone aggergate as in earthing pit with CI cover and framing including necessary earth work etc complete all as specified .Note- PCC chamber shall be constructed at least one meter away from the building shall be provided in slanting manner.Note- PCC cover pit shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 kg (sqm in liew of CI) complete all as specified and directed.
shakti construction (BID ID -3333095)
SM CONSTRUCTION COMPANY (BID ID -3339075)
Mahesh Enterprises (BID ID -3336896)
Laxmi traders (BID ID -3347279)
M/s. Kansal Construction Co. (BID ID -3347208)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .