EE I KNHED PW Dte.
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of Ventilation Air Conditioning System in lower basement at TERTIARY CARE CENCER CENTER TCC under college of Medicine Sagar Dutta Hospital Kamarhati Kolkata
2021_WBPWD_358370_1
WBPWD/EE/KNHED/NIQ-110/21-22
Open Tender
A/C ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹56,000
28 Jan 2022
29 Dec 2021
17 Jan 2022
31 Dec 2021
15 Jan 2022
31 Dec 2021
Amount
Supply, installation, testing and commissioning of following capacity FCUs complete with necessary valves, fittings, thermostat and three pin top and socket for power make - ZEECO/EDGE TECH 2.0 TR
MS PIPING Supply and installation of MS heavy class pipe with 25 mm thick closed cell class 'O' nitrile rubber insulation with all necessary clamps and support. 32mm dia
EXHAUST/FRESH AIR FANS Supply, Installation, Testing and Commissioning of Axial/ Centrifugal Fans for lower and upper basement floor with bird screen and TEFC squirrel cage induction motor.Motor shall be suitable for 415±10% volts, 50 cycles, 3 phase AC supply. 2000 CFM, 70 mm static (For F/Air)
2000 CFM, 70 mm static (For Exhaust Air)
DUCTING WORK Supply, Installation, Testing and Commissioning of site fabricated ducts with GI sheet complete with necessary duct supports 24 SWG
Supply and installation of 13mm Thick Aluminium foil Faced Class O fire rated Nitrile rubber Thermal insulation for Ducting
LOUVERS/GRILLES Supply, Installation, Testing and Commissioning of extruded aluminium powder coated exhaust air louver
Supply and installation of Aluminium Powder Coated Supply air Grille/ Diffuser with Collar Dampe
ELECTRICAL WORK Supply and installation of Electrical DOL 3.5 KW 3 phase Starter Panel with Push Button and indicator ( for 3 phase AXIAL/Centrifugal fan) (Make-L&T/ABB/Siemens)
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F of 16 Amp DP MCB, 10 KA Braking capacity in 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required with Supply & Fixing 240 V,20 A, 3 pin plug top with indicator (Brand approved by EIC) & necy. Connections of 5 mtr. of 2.5 sq mm 3 Core Flexable copper cable ( for Single phase FCU)
Supply and laying of 4C x 4 Sq mm armoured aluminium Cable power cable
Supply and installation of 8SWG GI Earthing Wire
Supply and installation of Electrical Plug Socket for incoming power Supply including 1.5 Sqmm Cu flexible cable (5 Rmt) 2.0 TR
PUMPING SYSTEM FOR DRAINAGE OF CONDENSATE WATER FOR AC SYSTEM
Supply, Installation, testing and commissioning of 1000 Ltr. HDPE Tank along with 2 nos. pumps (1w+1S) drain water monoblock pumps single phase 1 HP along with pump starter panel , level sensor for qutomatic opeartion of pumps , HDPE Tanks should be insulated with 32 mm thick class O nitrile Rubber necessary PVC pipes valves to be consider
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties) (Defect Libilities Period of 01(one) year from the date of completation of work.)
S.R. REFRIGERATION AND APPLIANCES
SOUMYA ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .