Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹17.1 L+₹9,422 (0.55%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
5 Oct 2021, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2021_MES_474040_1
86830/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEOLALI
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹40,000
Yes
2 Nov 2021
9 Sept 2021
7 Oct 2021
9 Sept 2021
5 Oct 2021
23 Sept 2021
10 Sept 2021 - 16 Sept 2021
Amount
M&L for complete servicing and repair of Split type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, re-fixing in the same position and testing complete all as specified and directed.
Supply only the following items required to incorporate in item No 1.00 above:-
Hermetic sealed compressor unit with new factory made sealed compressor unit suitable for R-22 refrigerant of existing model of make LG/Godrej/Hitachi/ Voltas/Carrier single phase electrically operated on 240 V suitable for Split AC 2.0 Ton capacity.
Hermetic sealed compressor unit with new factory made sealed compressor unit suitable for R-22 refrigerant, of existing model of LG/Godrej/Hitachi/ Voltas/Carrier single phase electrically operated on 240 V suitable for Split AC 1.5 Ton capacity.
Blower electric motor single phase 230 V complete for inner unit as per existing make and model of LG/Godrej/Hitachi/ Voltas/Carrier for 1.5/2.0 ton split AC
Fan electric motor single phase 230 V complete for outer unit as per existing model of LG/Godrej/Hitachi/ Voltas/Carrier for 1.5/2.0 ton split AC.
Startring/ Running capacitor of suitable capacity (50 mfd to 60 mfd+ 4 mfd dual ) dual type for 1.5/2.0 Ton split AC as per existing model of make LG/Godrej/Hitachi/ Voltas/Carrier
Overload protector suitable for split Ac of capacity for 1.5/2.0 ton of existing make and model of LG/Godrej/Hitachi/ Voltas/Carrier
Drain pipe for Split unit PVC 20mm
Fan blade metal/ plastic of suitable size for outer unit as per existing make and model for 1.5/2.0 ton split AC of LG/Godrej/Hitachi/ Voltas/Carrier
Condensor coil assembly for split type 1.5/2.0 ton AC as per existing model made of copper tubing ( for outer unit) of LG/Godrej/Hitachi/ Voltas/Carrier
Evaporating coil assembly for split type 1.5/2.0 ton AC as per existing model made of copper tubing ( for inner unit) LG/Godrej/Hitachi/ Voltas/Carrie
Blower for split air conditioner 1.5/2.0 ton as per existing make and model of LG/Godrej/Hitachi/ Voltas/Carrie
Remote control kit (PCB) complete for Split type AC of capacity 1.5/2.0 TON
Remote for Split type AC of capacity 1.5/2.0 TON
Bi metalic contact suitable for 1.5/2.0 Ton Split AC as per existing model of LG/Godrej/Hitachi/ Voltas/Carrie
M&L for complete servicing and repair of Window type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections etc re-fixing in the same position and testing complete all as specified and directed.
Supply only the following items required to incorporate in item No 3.00 above:-
Hermetic sealed compressor unit with new factory made sealed compressor unit suitable for F-22 refrigerant, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity of existing model of make LG/Godrej/Hitachi/ Voltas/Carrier
Hermetic sealed compressor unit with new factory made sealed compressor unit suitable for F-22 refrigerant, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity of existing model of LG/Godrej/Hitachi/ Voltas/Carrier
Capacitor of suitable capacity for Window AC 1.5/2.0 Ton capacity.( 36 to 60 MFD) single type
Auto cut thermostate of existing model suitable for window AC of 1.5/2 Ton of LG/Godrej/Hitachi/ Voltas/Carrier
Overload protector suitable for Window AC of capacity for 1.5/2.0 ton of existing model of LG/Godrej/Hitachi/ Voltas/Carrier
Grill plastic body for window AC of suitable size/shape /model as required at site for 1.5/2 Ton of LG/Godrej/ Hitachi/ Voltas/Carrier
Fan blade of metal/ plastic of suitable size for window type AC unit of make LG/Godrej/Hitachi/ Voltas/Carrier
Fan/blower electric motor metal body single phase 230 V complete for 1.5/2.0 ton AC as per existing model of LG/Godrej/Hitachi/ Voltas/Carrier
M&L for complete servicing and repair of Water Cooler of 40/80 & 60/120 Ltr capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, re-fixing in the same position and testing complete all as specified and directed.
Supply only the following items required to incorporate in item No 5.00 above:-
Hermetic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for refrigerant R 134a of existing model suitable for Water cooler 40/80 Ltrs of make Blue Star/ Voltas/Leonard/Usha
Hermetic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for refrigerant R 134a of existing model suitable for Water cooler 60/120 Ltrs of make Blue Star/ Voltas/Leonard/Usha
Fan/blower electric motor single phase 230 V complet for water cooler 40/80 or 60/120 Ltrs capacity water cooler of existing model of make Blue Star/ Voltas/Leonard/Usha
Running /starting capacitor of suitable capacity 4 MFD to 10 MFD Make- Epcos/ havells
Float valve of 15mm size plastic body for water cooler of make Blue Star/ Voltas/Leonard/Usha
Auto cut thermostat switch as per existing make and model for water cooler of capacity from 40/80 Ltrs to 60/120 Ltrs of make Blue Star/ Voltas/Leonard/Usha
Overload protector as per existing make and model for water cooler of capacity from 40/80 Ltrs to 60/120 Ltrs of make Blue Star/ Voltas/Leonard/Usha
Fan blade metal/ plastic body of suitable size of existing make and model for water cooler40/80 Ltrs to 60/120 Ltrs of make Blue Star/ Voltas/Leonard/Usha
Push cock/soft closing tap brass chromium plated of size 15 mm
M&L for complete servicing and repair of Refrigerator of capacity 165 to 350Ltrs, servicing and cleaning of all accessories, oiling/ greasing of fan motor (286/310 ltr double door only), checking of wiring connections, re-fixing in the same position and testing complete all as specified and directed.
Supply the following items required to incorporate in item No 7.00 above:-
Hermetic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for R 134a Refrigerant for 165 Ltrs capacity refrigerator as per existing model of make Samsung/Whirlpool/ Godrej/ Voltas
Hermetic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for R 134a Refrigerant for 286/310 Ltrs capacity refrigerator as per existing model of make Samsung/Whirlpool/ Godrej/ Voltas
Auto cut thermostat switch as per existing make and model for refrigerator of capacity 165 to 310 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Overload protector switch as per existing make and model for refrigerator of capacity 165 to 310 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Copper strainer filter as per existing make and model for refrigerator of capacity 165 to 310 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Magnetised door lock rubber strip 'D' type as per existing make and model for refrigerator of capacity 286/310 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Evaporator coil assembly of copper pipe as per existing make and model for refrigerator of capacity 165 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Evaporator coil assembly of copper pipe as per existing make and model for refrigerator of capacity 286/310 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Condensor coil assembly of copper pipe as per existing make and model for refrigerator of capacity 286/310 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Bi metalic contact as per existing make and model for refrigerator of capacity 165 to 310 Ltrs of make Samsung/Whirlpool/ Godrej/ Voltas
Supply and filling / charging refrigarating gas R-22 in Window/Split AC of capacity 1.5/2.0 ton.
Supply and filling / charging refrigarating gas R-290 in Window/Split AC of capacity 1.5/2.0 ton.
Supply and filling /charging refrigarating gas R 134A in refrigarator/ Water cooler of any capacity.
Supply and filling /charging refrigarating gas R 407C in package AC of any capacity.
Supply and fix Air Conditioner Copper Pipe of Size: 2"-3" suitable for 1.5/2.0 Ton split Air conditioner
Suppy and fix blower fan300mm/80 Watt /1350 RPM complete for walk in cooler of make blue star complete as per existing make and model ( Make high cool, Model No- YMF 4E-300S)
Suppy and fix refrigerant pressure guage bouden type 0 to 16 Kg/sqcm pressure range ( for F-22 Refrigerant)
Suppy and fix refrigerant pressure guage bouden type 0 to 25 Kg/sqcm pressure range ( for F-22 Refrigerant)
Supply and fixing PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 2.5 Sqmm
Supply and fixing PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 4.00 Sqmm
Supply and fix capillary copper tube for window , split, water cooler , refrigerator as per existing make and model/size
Taking down of split AC 1.5/2 T capacity from existing position for spl repair/ roof treatment of bldgs and refixing in same/another position incl both inner and outer units & connected accessories complete all as specified and directedat site.
S&F electronic type star delta timer 3-30 sec type ET-100/ ST-100 of make L&T (Note: ST 100 should be supplied with Mounting Kit, suitable for ET 100 replacement.)
M&L for carrying out leak test of split/window type air conditioner 1.5/2.0 ton capacity by filling in nitrogen gas to required pressure, rectifying the defect by soldering/brazing/ welding,repacing the connecting nut, flaring the copper tube etc complete all as directed at site.
M&L for Cleaning of AHU unit of 45 TR capacity plant OT & ICU, with cleaning Agent, cleaning of micro filters/hepa filters, cleaning complete unit inner and outer side complete all as directed
Dismantling the condensor flanges and cleaning the water tubes by suing cleaning agent & soft wire brush and solvant as recommended by the mfg and re-assembling the same by providing new gasket and all necessary connections etc complete all as directed.
Supply and charging refregerating gas F-22 in Centralised Air Conditioning plant of capacity 3x45 TR complete all as directed
S&F in repair V-belts of the size/ model B-70
S&F in repair V-belts of the size/ model B-97
S&F in repair V-belts of the size/ model C-103/C-104
S &F micro Air filter (5-10 Micron) of size 61cmx61cmx15cm of AHU (OT) of AC plant complete as per existing make/model incl taking down old u/s filters all as directed at site
S &F micro Air filter (5-10 Micron) of 45cmX45cmX15cm size for AHU made of stainless steel complete as per existing make/ model incl taking down old u/s filters all as directed at site
S & F Hepa filter of size 61cmx61cmx30cm (5 micron per filter ) as per existing make /model incl taking down old u/s filters all as directed at site
Dismantaling /opening the compressor and overhauling of 45 TR capacity Make: Accel Model SMC-4-100 of chilling plant, repair/replacement of the u/s parts complete all as specified and re assembling the same and testing for smooth fuctioning to the entrire sactisfaction of Engr-in-Charge.
Supply & fixing the following spare parts for item Sr No-32 ( Compressor Make -Accel, Model SMC-4-100)
Suction valve reed
Discharge valve reed
Piston ring set
CR bearing
Gasket set
SV Spring
DV Spring
Rocker arm spring
Rocker arm
Shaft seal assembly
Pistpn oil ring set
Piston
Connecting rod
Piston pin
CR bolt
Castle nut
Single frame for unloadin
Oil filter
Pressure switch
Oil pressure Control valve
Supply and filling/ toping up compressor oil N-68 complete all as specified and directed
Checking and testing for leakage of gas of the complete system by filling nitrogen gas at required pressure keeping 24 hrs under observation and rectifying the leakage completely for 45 TR capacity centralised AC plant all as directed and upto entire satisfaction of Engr-in-Charge. (compressor No 1 & 2)
Supply & fixing over load relay for star-delta starter 10-16 Amps type ML for contactor ML-1.5/2.0 of make L&T
Supply & fixing over load relay for star-delta starter 9-42 Amps type ML for contactor ML-1.5/2.0 of make L&T
Supply & fixing thermal over load relay for star-delta starter 66-110 Amps type MN 5 of make L&T Model Code- SS94137OOKO
Supply & fixing contactor ML-1.5 of make L&T with 2NO+ 2NC auxiliary contacts and coil voltage 230/240 Volt
Supply & fixing contactor ML-2.0 of make L&T with 2NO+ 2NC auxiliary contacts and coil voltage 230/240 Volt
Supply & fixing contactor ML-4 of make L&T with 2NO+ 2NC auxiliary contacts and coil voltage 440 Volt
Supply & fixing coil for ML- 4 contactor of coil voltage 415 volts
Supply & fixing contactor 25 Amps AC3 rating MNX-25 of coil voltage 4415 volts of make L&T
Supply & fixing front add on auxiliary contract 2NO+ 2NC
S&F MCCB 3 pole 125 Amps 30 KA of make L&T /SEIMENS/ LEGRAND
S&F MCB TPN 32 Amps 10 KA of make L&T /SEIMENS/ LEGRAND
S&F in repair HP/LP/OLP cut out switch as per existing make and model for 45 TR cetralised air conditioning plant complete all as specified and as directed.
S&F in repair magnetic coil as per existing make and model suitable for 45 TR capcity AC plant complete all as specified and directed
M&L painting to cooling tower inside and outside with one coat of primer and two coats of epoxy paint of approved colour including scapping out the old paint complete all as specified and as directed
M&L for painting to pipe line from cooling tower to AC Plant (Suction and delivery) with two coats of synthetic enamel paint of approved colour including preparation complete all as specified and as directed.
Dismantling and taking to the local workshop the motor of following capcity 3 phase 415 V 50 Hz by taking out the burnt out winding complet, and M&L for re-winding with super enamelled copper wire of appropriate guage and number of turns etc complete and heat warnishing and other spares as required such as DE and NDE bearings necessary machining work of shafts, testing and re-assembling, painting complete and testing for its proper functioning complete all as specified and as directed:- 60 HP Motor
All as per item No 51 Above but 10 HP Motor
All as per item No 51 Above but 7.5 HP Motor
All as per item No 51 Above but 5 HP Motor
Repair to remot cotrol kit (PCB) of split type AC of 1.5/2.0 TON by replacement of u/s components
S&F Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 20 Amps MCB SP complete as specified and directed Make : L&T /STANDARD / HPL / Legrand
Supply and replace of plug top 3 pin 15 amps ISI marked complete all as specified and directed
Repairs to the star- delta starting panel of 60 HP electric motor by replacing the old wiring and other unserviceable components. Note:-( 1) cost of wire is deemed to be included in rate quoted. (2) other components will be measured and paid under respective item of schedule as supply & fixing.
Repairs to the star- delta starting panel of 10 HP/7.5 HP/5.0 HP electric motor by replacing the old/unserviceable 1.5 sqmm copper wiring and other unserviceable components. Note:-( 1) cost of wire is deemed to be included in rate quoted. (2) other components will be measured and paid under respective item of schedule as supply & fixing
Supply and fixing indicating lamp red/green as per existing make/ model for starter panels of 10 HP motor.
Repair / sevicing to pakage type Air conditioner of 20 ton capacity by cleaning the whole unit , cleanging the filter, oiling/ greaseing the fan and blower motor, checking the condition of compressor, charging the R-22 GAS to required pressure, tighening the all loose connections and nut bolts etc complete all as directed at site. Note:- R-22 Gas will be measured and paid separately.
Repair / sevicing to pakage type Air conditioner of 3X5 ton capacity by cleaning the whole unit , cleanging the filter, oiling/ greaseing the fan and blower motor, checking the condition of compressor, charging the R-22 GAS to required pressure, tighening the all loose connections and nut bolts etc complete all as directed at site. Note:- R-22 Gas will be measured and paid separately.
Repair / sevicing to walk in cooler of make blue star by cleaning the whole unit , checking and seting the control panel torequired value, oiling/ greaseing the fan and blower motor, checking the condition of compressor, charging the R-22 GAS to required pressure, tighening the all loose connections and nut bolts etc complete all as directed at site. Note:- R-22 Gas will be measured and paid separately.
Repair/ servicing to chiller/ condensor pump of 10 HP of centralised AC plant at M H Devlali by dismantling the pump, cleaning internaly, cleaning the impeller, greasing the bearings, replacing the defective bearing if any, tightening the any loose nut bolt etc complete all as directed at site.
Repair/ servicing to cooling tower of centralised AC plant at M H Devlali by dismantling the fan and moter, cleaning internaly, cleaning &, greasing the bearings, replacing the defective bearing if any, tightening the any loose nut bolt, replacing the clampe of blae etc complete all as directed at site.
Supply & fixing cooling tower drive shaft of Aluminium suitable for 45TR AC Plant as per existing make/model
Supply & fixing Cooling Tower Sprinkler of Aluminum suitable for 45TR AC Plant as per existing make/model
Supply and fix Compressor 3.0 TR capacity as per existing model for walk in cooler of make Bluestar
Supply and fix Compressor 5.5 TR capacity scroll type as per existing make and model for package type AC of make Voltas
M&L for repair to control circuit of compressor of centralised AC plant of 45 TR capacity by replacement of control wiring, toggle swiches (6 Nos), connector block and indicating lamps 3 Nos, making all connections to safety devices like HP/LP/OLP cut out, pressure guages of suction 7 discharge line and testing on completion complete all as spesified and directed at site to the full satisfaction of Engr-in- Charge.
Supply and fix industrial thermometer Dial type
Supply and fix Industrial Thermometer mercury type
Supply and fix 100 mm size sluice valve PN 1.6 Hand Wheel Operated, Non-Rising Stainless Steel Stem, Bronze Body Seat Ring. Flange type.
Supply and fix 100 mm size non return valve Swing Type with Nitrile Rubber Flap, flanged end.
United Enterprises
Bidder Name
United Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .