Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 19 1A BOSE PUKAR ROAD KASBA GROUND FLOOR KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.5 L+₹1.1 L (5.63%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to not enlisted in category a(i) | |
| 4 | Rejected-Technical HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | - | Rejected-Technical Due to not enlisted in category a(i) | |
| 5 | Rejected-Technical 2A 40 1 DHARMATALA ROAD KASBA KOLKATA WEST BENGAL 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | - | Rejected-Technical Due to not enlisted in category a(i) |
Tender Value
₹20.4 L
EMD Value
₹40,760
Closing Date
29 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE (AF) LEH
HQ CWE (AF) LEH
WORK SERVICES FOR INSTALLATION OF QTY-1 OXYGEN GENERATION PLANT AT AIR FORCE STATION LEH (PHASE-II)
2023_MES_620445_3
81174/E8
Open Tender
Miscellaneous Works
Works
180 days
LEH
As per tender documnets
7 documents required · 7 mandatory
₹500
GE (AF) LEH
₹40,760
Yes
14 Mar 2024
1 Jan 2024
31 Jan 2024
1 Jan 2024
29 Jan 2024
16 Jan 2024
Amount
75 mm thick, cement concrete type C-2, 1:3:6 using 40 mm graded stone aggregate, finished even & fair, as in sub base of floors , etc.complete all as specified.
40 mm thick, cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate, finished even & smooth, as in floors, complete all as specified.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in foundation filling, mass concrete etc., complete all as specified.
Providing & fixing false ceiling with semi perforated 8 to 12 mm thick micro tegular edged GRG false ceiling tiles at all height with GRG (Glass fiber reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987. Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm inculding both sides) comprising of maint runners of size 15x32mm of length 3000mm, cross-T of size 15 x 32 mm length 1200mm and secondary intermediate cross-T of size 15 x 32mm of length 600 to form grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasterners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85 x 25x 2mm. Galvanised iron perimeter wall angle of size 24x 24x 0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plaastic rawl plugs at 450 mm center to centrer and 40mm long dry wall wood screws including dismantling of wall and ceiling board (fibre, pulb, insulations ,etc) or insulation board / slabs/blankets, any thickness including cover. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Anodised aluminium frame for doors, windows, ventilators, fixed glazing with one or more rebates including joining cleat for fixing, fixed to opening with suitable size steel screws and rawl plugs etc., (aluminium section not less than 2 mm) complete all as specified.
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, suitable size of handles 2 Nos in each door, hinges 03 nos ,anodised aluminum snap beading screws etc. complete all as specified
Plain Sheet glass 4.8 mm thick, ordinary quality and glazing with rubber packing to sliding window in squares exceeding 0.5 Sq. mm in each pane, complete all as specified.
Pre-laminated particle board 9 mm thick, interior grade, pre-laminated both sides, ISI marked (IS:12823) fixed with screwto aluminium frame, etc., complete all as specified.
50 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc.,complete all as specified and directed by Engr-in-charge.
One coat of synthetic enamel paint over old painted steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5 cm but not exceeding 30 cm long, dia of neck 11 to 15 mm, complete all as specified.
S&F Fire Alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & modules upto 200 detector including the following technical specifications and all specified and directed Engr-in-Charge. (a) Primary power supply : 220v +/- 10% AC, 50Hz(b) Standby power supply : 24 V DC (2 Nos of 12V, 7 SMF batteries )(c) Battery charging voltage ; 27.5 +/- 1V(d) Battery caharging current : 500 mA (max)(e) Pragrammable relay contact : 3 Sets.(f) Relay Contact Rating : 2 Amps 30 V DC(g) Operating temp :- 100C to +550C(h) Humidity : 0 to 95% RH(j) Internal wiring complete two core (k)1000 event history log(l) Built in battery Charger(m) Contamination level alart for maintenance (n) Detection sensitivity adjustments (from panel)(o) Alarm verification feature (p) upto 127 devices per loop. MAKE:HONEYWELL/EDWARDS/NOTIFIRE/SYSTEM SENSER
S&F smoke and heat multisensor detectors complying with and type certified to EN-54 Addressable type Photoelectric / optical with base with self built indigence as per IS : 11360 including the following technical specifications and all as specified and directed Engr-in-Charge. (a) Oprating voltage : Between 15-30 volts DC peak(b) Max Stand by current : less than 1mA (c) Alarm LED current : Max 1mA(d) Oprating temp :- -100 c to +550C(e) humidity : 0 to 95% RH(f) Wiring : 2 core(g) LED to provide 360 visual supervision(h) Blinking LED for visual supervision(j) Built-In test from panel Electronic Addressing(k) Identification of contaminated detector (l) high Immunity to False Alarm (m) Aitomatic device mapping (n) Alarm flag by fixed temperature or rate of rise temperature for fast Alarm reporting(o) Remote test feature (from the panel)(p) multi level sensitivity and remote sensitivity alteration (from panel)(q)Detects and activates Alarm on temp rise , rate of rise of temp and on smoke level through IR scattering. MAKE:HONEYWELL/EDWARDS/NOTIFIRE/SYSTEM SENSER
S&F Addressable manual call point resttable type including the following technical specifications and all specified and directed Engr-in-Charge. (a) Oprating voltage : Between 15-30 volts DC peak(b) Max Stand by current : less than 1mA(c) Alarm LED current : max 1 mA(d) Operating Temp :- 100 C to +550 C(e) humidity : 0 to 95% RH(f) Wiring : 2 core(g) Protective transparent flip cover to prevent accidental activation(h) Electonic Addressing (j) Blinking LED for visual supervision(k) No frangible glass(l) Stable Communication with noise immunity(m) Automatic device Mapping. (n) Alarm flag for fast alarm reporting. MAKE:HONEYWELL/EDWARDS/NOTIFIRE/SYSTEM SENSER
S&F Fire Alarm Sounders/ Sirens electronic type horizontal single stage continous normal operation for at least 50minuts with sound level 65 DB to 120DB measured at 1.5 mete with sound output variation of + 5DB for 1000 meter Range including the following technical specifications and all specified and directed Engr-in-Charge. (a) Operating voltage : between 15-30 volts DC peak (b) Max Stand by current : less than 1mA(c) Active average current : Less than 50mA(d) Sound level : More than 50 mA (e) Operating tem :- 100c to +550c(f) Humidity : 0 to 95% RH (g) Wiring : 2 core (h) An integral beacon within the sounder utilizing high intensity LED technology(j) Capable to accept & act on various instruction from the control panel, like alert, evacuate , security , emergency , Shift-bell etc with various types of flash. The acoustic efficiency and sound distribution should generate a wide angle good audibility in all directions.(k) Electronic Addressing (l) remote test feature (from panel)(m) Strobe be high intensity LED technology
S&F Remote response indicators including the following technical specifications and all specified and directed Engr-in-Charge.(a) Operating voltage : between 15-30 volts DC peak (b) Active average current : Less than 20 mA(c) Operating tem :- 100c to +550c(d) Humidity : 0 to 95% RH(e) Wiring : 2 core (f) Capable of high response (g) Real time response MAKE:HONEYWELL/EDWARDS/NOTIFIRE/SYSTEM SENSER
Supply, laying & testing PVC insulated, PVC sheathed FRLS cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all specified and directed Engr-in-Charge. (Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
Supply,installation,testing and commissioning of hot and cold AC , hi wall split unit indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better in door air quality with minimum 5 star and EER 3.2 of capacity 2 ton ,410 Gas complete including suitable size of outdoor unit stand all as specified and directed by Engr-in-charge. MAKE:VOLTAS/BLUESTAR/DAIKIN/HITACHI
Automatic voltage stablizer copper wound, with low and high cut off relay and time delay relay complete with indicator switches voltmeter ,MCB of suitable rating,single phase ,50 c/s AC supply naturally air cooled indoor type,wall mounted and designed for input voltage range 170 to 250 volt and output voltage 230 volt tolerence limit 10% of capacity 05 KVA including making electrical connections ,complete all as specified and directed by Engr-in-charge.MAKE:V-Guard / Microtek/Blueline
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface ,complete all as specified and as directed by Engr-in-charge. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Exhaust Fan ,steel body,AC single phase,230 V of size 300 mm sweep with blades,frame and louvers complete including making hole in existing wall,grouting the exhaust fan bolt including PCC 1:2:4 and making good the surface ,complete all as specefied and directed by Engr-in-charge.
Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A, complete all as specefied and directed by Engr-in-charge.
Fabrication and installation perforated GI cable tray of size 150 mm wide and 1.6 mm thick,including horizontal and vertical bends,reducers,tees,cross members and other accessories as required and duly suspended from the ceiling with MS suspenders including painted etc, complete all as specefied and directed by Engr-in-charge.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 150 sqmm 3.5 core including necessary cable lugs, glands, insulation tape complete all as directed and specified.
FR PVC insulated and PVC sheathed round flexible,heavy duty electric power cable with stranded copper conductor , 1100 Volt grade, cross sectional area 35 sqmm 4 core including necessary cable lugs, glands, insulation tape complete all as directed and specified.
FR PVC insulated and PVC sheathed round flexible,heavy duty electric power cable with stranded copper conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape complete all as directed and specified.
FR PVC insulated and PVC sheathed round flexible,heavy duty electric power cable with stranded copper conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape complete all as directed and specified.
Earthing complete with copper plate elecrode of size 60cm×60cm ×3.15mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth 20×3mm copper strip by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of copper strip wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces. excavation in a soil, returning filling and removal of surplus soil to a distance of 50 metre as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009) .
Earthing with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with tope edge of the plate not less than 1.5mtr below normal ground level, connected to galvanized earth strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides earth work GI pipe light grade 40mm bore for protection of GI strip from earth electrod to earth dolly supplying and laying charcoal dust common salt PCC 1:2:4 type B-1 chamber and RCC copver 40mm thick (1:2:4) type B-1 using 20mm graded stone aggtregate reinforcedwith 8mm die TMT bars @ 100mm C/C both ways with MS handle 12mm dia PGI funnel and wire mesh 20mm dia GI pipe light grade for watering all as shown in electrical plate No 3 and connected to earthing test point including testing complete all as specified and directed.
Point wiring for one light/Fan/bell point controlled by one switch one way in & including PVC conduit or casing and capping as per site requirement using FRLS PVC unsheathed multistrand copper conductor cable 1.5 sqmm single core for one light/fan point/bell point controlled by one switch including 3 mm thick plastic laminated sheet cover over PVC / wooden Box for earth continuity insulated PVC unsheathed(green colour) 1.5 sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engr-in-charge. Note : (a) wiring shall be done by using proper colour coding.
Socket outlet 2-in-1 3 pin 5 Amps flush type 230 volts complete all as specified.
Ceiling rose 3 terminal size 50x65mm surface type 230 volts complete all as specified.
national engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .