Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹50.0 LAdmitted-Finance | +4.95% | ₹50.0 L | L1 | Admitted-Finance |
| 2 | L2₹52.5 L+₹2.5 L (5.03%)Admitted-Finance H NO 351 F NEAR SHANTADURGA TEMPLE SHANTINAGAR AQUEM BAIXO NAVELIM GOA 403707 | NAVELIM | SOUTH GOA | GOA | 403707 | +10.23% | ₹52.5 L+₹2.5 L (5.03%) | L2 | Admitted-Finance |
Tender Value
₹47.7 L
EMD Value
₹95,307
Closing Date
14 Jan 2026, 5:00 pmClosed
Executive Engineer
Div III Curti Ponda
Work of shifting of 110KV MRF/SWR Double Circuit line Tower near Amigos Hotel at Curti, Ponda, Goa in view of National Highway NH748 Expansion work on request of PWD, Sub-Div-I, Works Division, Ponda.
2025_ED_26997_1
Tender-05/25-26
Open Tender
Electrical Works
Percentage
180 days
Near Amigos Hotel Curti Ponda
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹95,307
Yes
25 Mar 2026
31 Dec 2025
16 Jan 2026
31 Dec 2025
14 Jan 2026
1 Jan 2026
Cost of Supply
Supply,installation , testing & commissioning of Double suspension Hardware fitting with clamps, & complete accessories , conforming to IS ammended upto date, suitable for ACSR coyote conductor
110 KV Suspension composit silicon rubber insulators B and S 16mm, 90KN, 3440CD.
Supply of double circuit utility pole suitable for 110KV double circuit lines. Price offered are for all structural components of the pole, Anchor bolts, Anchor plate and Template. Pole type SUSPENSION POLE " P (0 to 2d)" +6m as per ANNEXURE- 2
Earthing complete with 40mm GI Pipe, 2.5mt long along with bantonite complete with brick masonary(Supply)
Cost of Erection
Supply,installation , testing & commissioning of Double Suspension Hardware fitting with clamps, & complete accessories , conforming to IS ammended upto date, suitable for ACSR coyote conductor
110 KV Suspension composit silicon rubber insulators B and S 16mm, 90KN, 3440CD.
Erection of double circuit utility pole suitable for 110 kV double circuit lines. Prices offered are for all structural components of the pole, Anchor Bolts, Anchor Plate and Template. Pole Type SUSPENSION POLE P (0 to 2d) plus 6m as per ANNEXURE- 2
Erection of ACSR Coyote conductor ( i.e removing & restringing at cutpoint side if required)
Earthing complete with 40mm GI Pipe, 2.5mt long along with bantonite complete with brick masonry(Erection)
Cost of Dismantling
Dismantling of existing 110KV Lattice Tower on 110KV MRF/SWR D/C line [TLN-05] near Amigos Hotel at Curti, Ponda, Goa
Dismantling of existing suspension hardware of existing suspension tower art TLN-05
Removing of old 110KV Disc Insulators with metal parts including transportation at 220KV SS Ponda.
Cost of Civil Works
Foundation for double circuit utility pole suitable for 110 KV double circuit lines including excavation,rubble packing, P.C.C., Centering and shuttering, Steel reinforcement, R.C.C. for Footing and pedestal, template setting and providing required foundation bolt and nuts etc complete in all aspects including bailing out of water wherever required. Pole type SUSPENSION POLE P (0 to 2 d) plus 6m. as per ANNEXURE-1
Drilling 150mm dia bore holes at variuos locations in soil/rock using approved method as detailed in technical specification and direction of owner performing standard penetration test at 3mt interval and at a change strata , transportattion of all collected samples to laboratory and back filling of holes on completion of same complete in all respect as per specification and direction of owner including a depth below natural level ground up to 15mts or refusal of depth whichever is earlier.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.88 MB
BOQ_27444.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .