Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 LAccepted-AOC | 1 | Accepted-AOC LOWEST |
Tender Value
₹6.7 L
EMD Value
₹14,000
Closing Date
12 Mar 2020, 5:00 pmClosed
E.E. Ch.Dadri
PWD B and R Ch.Dadri
Special repair of PHC Nakipur in Bhiwani Distt.. (Reinvite)
2020_HRY_120962_1
Special repair of PHC Nakipur in Bhiwani Distt.. (
Open Tender
Civil Works - Buildings
Works
90 days
Charkhi Dadri
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Public Work (B and R) Department
₹14,000
Yes
25 Jul 2020
29 Feb 2020
13 Mar 2020
29 Feb 2020
12 Mar 2020
29 Feb 2020
Amount
Earthwork in excavation in foundations, trenches of under ground structures, sullaged drains etc and other similar works in ordinary soil including dressing of bottom and sides, to correct levels and templates, cutting of trees and bushes, dewatering of rain water, diversion of traffic, fixing and maintenance of caution boards, and night singals, crossing over trenches for access to houses, watching , stacking of excavated soil, clear from the edge of excavation, and subsequent filling, where required around masonary, in 15cm layers, with compaction and disposal of surplus soil as directed within a lead of 30 meters for depth upto 2 meters below natural ground level (for public Health works only) (HSR 6.7)
Removing door and windows (wood and steel) with chowkats by making recesses in walls when the wallis not to be dismantled (HSR 8.18)
Dismantling cement conglomerate / terrazzo-floors 25 mm to 50 mm thick including concrete base (HSR 8.25)
Scrapping (c) Cement plaster (HSR 8.32 c)
Cement concrete 1:8:16 with stone aggregate 40 mm Nominal sie in foundation and plinth. (HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20mm nominal size in foundation and plinth (HSR 10.41)
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.82 + 10.95 (a)]
Providing and laying 80 mm thick ISI marked internlocing paver paver blocks conforming to IS 15658:2006 /IRC:SP:63-2004 of all Shapes and colours in design mix cement M-40 over a bed of 30 mm thick fine sand complete in all respect. (HSR 10.159).
First class brick work laid in cement sand mortar 1:4 in foundation plinth. (HSR 11.4)
Terracing consisting of tiles 22.86 cm X 11.43 Cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc., (HSR 13.13)
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.89]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 100 mm dia PVC pipe 6 kg. pressure.
Providing and fixing PVC Bend ISI Mark. (Note:- Reputed make PVC Bend such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.90].100mmdia
Providing and fixing vitrified tiles of size 600x600mm of approved make in flooring laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJA-RIA, SOMANI, ORIENT, JOHNSONS & RAK (HSR 14.89)
Providing and fixing vitrified tiles of size 600x600mm of approved make in skirting/ dado laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJA-RIA, SOMANI, ORIENT, JOHNSONS & RAK (HSR 14.90)
12 mm Thick Cement Plaster 1:4 on the rough side of single or half brick wall. (HSR 15.5).
Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1)
Providing and Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2)
Providing and Applying Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3).
Painting two coats with plastic emulsion paint on walls on new work to give an even shade. (HSR 16.30)
Providing and Applying Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81). Through Rate
Factory manufactured wire gauze door and window shutters of commercial hard wood such as Hollock, Champ, Chikrassy & Chaplash only. (non-coniferous timber other teak conforming to I.S. specification No. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc., complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position. (Styles and rails of windows shutter shall be 75 mm wide. (ii) 35 mm thick. [HSR 17.92 (ii) - Note 1 under 17.18]
Factory manufactured Solid Flush Door Shutter, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Note:- reputed make such as Duro, Green, Kitply will be used as approved by Engineer-in-charge). HSR 17.93 (a) - Note 1 under 17.18]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (iv) 25 mm thick.
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including Straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths /storeys/ basements etc. (Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement). (HSR 18.22).
Pressed steel sheet frames (chowkhats) consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete. (a) door and window frame Size of 89 mm x 59 mm with 40 mm wide signel rebate. (HSR 18.34, a)
(c) door and window frame size 127 mm X 50 mm with 40 mm wide double rebate. (HSR 18.34 c)
Providing & fixing in position best indian make Indian type Orissa or orya water closet suite complete with 100mm H.C.I. 'P' trap and allother necessary fittings.Size 630 mm white (HSR 30.2 b i)
Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- white (ii) Size 480 mm x 400 mm with one no. tap. [HSR 30.41(ii)].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body
bib cock
Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (i) Stop cock male and female [HSR 30.76 (a) (ii)].
ii) Concealed stop cock with flange.
Providing and laying 100mm thick GSB
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .