REPAIR MAINT HT LINE VCB RMU TRANSFORMER AND ALLIED WORK AT 2003 STN, AF STN GURGAON NTS GURGAON UNDER GE (AF) GURGAON
2026_MES_793720_1
CWE/GGN/GT-32/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE AF Gurgaon
As per NIT
8 documents required · 8 mandatory
₹1,000
GE AF Gurgaon
₹1.3 L
Yes
13 Oct 2026
13 Oct 2026
13 Nov 2026
13 Oct 2026
11 Nov 2026
4 Nov 2026
13 Oct 2026 - 2 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Repair/servicing of Transformer of capacity Upto 1000 KVA by cleaning all the carbon deposit from the HT/LT bushing inlcuding opening and reassembling for detecting of leakage of transformer oil if any and making it leak proof, checking of conservator including replacement of defective parts as supply only all as specified and directed | 18 | Each Job | - | - |
| 2 | Supply only new bushing LT side including brass set stems conical bush/gasket for indoor/outdoor transformer of capacity upto 1000 KVA complete all as specified and directed.
Note:- the rates quoted is deemed to be included the cost of necessary labour charges for drain out transformer oil, opening of top cover by unscrewing nut, bolts washers etc in item 1 above. | 11 | Each | - | - |
| 3 | Supply only new bushing HT side including brass set stems conical bush/gasket for indoor/outdoor transformer of capacity upto 1000 KVA complete all as specified and directed.
Note:- the rates quoted is deemed to be included the cost of necessary labour charges for drain out transformer oil, opening of top cover by unscrewing nut, bolts washers etc in item 1 above. | 11 | Each | - | - |
| 4 | Supply only new procelain transformer bushing HT 11 KV including brass set stems conical bush/gasket for indoor/outdoor transformer upto 1000 KVA complete all as specified and directed. Note:- the rates quoted is deemed to be included the cost of necessary labour charges for drain out transformer oil, opening of top cover by unscrewing nut, bolts washers etc in item 1 above. | 10 | Set of 3 | - | - |
| 5 | M&L for rewinding of HT/LT coils with copper wire DPC/super enameled high quality matching with existing gauge and impedance including all type of insulating material( paper/Cloth) in each layer or winding complete all as specified and directed.
Note:(i) The rate quoted against the item is inclusive of cost of all type of insulating material and heating/varnishing etc and transportation from site to workshop and back to site.
(ii) Item will be ececuted after pre- board of officers conveyed by GE in presence of competent testing authority. | 480 | KG | - | - |
| 6 | M&L for lamination and ovening in proper manner at workshop carefully for taking out servicable/unservicable HT/LT coils from the limbs complete all as specified and as directed. Note:(i) The rate quoted against the item is inclusive of cost of all type of insulating material and heating/varnishing etc and transportation from site to workshop and back to site.
(ii) Item will be ececuted after pre- board of officers conveyed by GE in presence of competent testing authority. | 8 | Each Job | - | - |
| 7 | M&L for re-arranging the top lamination cover coils in proper manner including fixing of top channel soldering in between coils as necessary and brazing or star delta connection with tap changer complete all as specified and directed.
Note:(i) The rate quoted against the item is inclusive of cost of all type of insulating material and heating/varnishing etc and transportation from site to workshop and back to site.
(ii) Item will be ececuted after pre- board of officers conveyed by GE in presence of competent testing authority. | 8 | Each Job | - | - |
| 8 | M&L for Dehydration including filtration and cleaning of Transformer oil by centrifugal dehydrating machine till to achieve Di-electric strength 50/60 KV at 2.5 mm gap incl testing of sample before and after dehydration and filtration all as specified and directed
NOTE:- (i)Contractor has to arrange the dehydration machine and testing kit without any extra cost to the dept. Test report to be submitted after completion of job.
(ii) Any damage occured to Transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Engr-in-charge at his own expenses. | 24,250 | Ltr | - | - |
| 9 | Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity confirming to IS-335 (latest) having dielectric strength not less than 60 KV with 2.5 mm gap complete all as specified and as directed .
NOTE:- (i) Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site
(ii) Transformer oil shall be brought at site in sealed compressor from the original manufacturer and shall be opened in front of engr-in-Charge. container shall be deposited by the contractor to the deptt, which will be returned after completion of contract. | 1,580 | Ltr | - | - |
| 10Supply and fix silica gel breather assembly complete with breather unit and silica gel including connecting with proper rubberised gasket and necessary fittings GI fittings for fixing/assembling for transformer complete by removing the unserviceable silica gel breather assembly all as specified and directed by Engr-in-chrage. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
BOQ_890151.xls
BOQ • 1.73 MB
TD.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .