Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr | L1 | Accepted-AOC LOWEST TENDERER |
| 2 | L2₹2.5 Cr+₹4.7 L (1.92%)Rejected-Finance | ₹2.5 Cr+₹4.7 L (1.92%) | L2 | Rejected-Finance NOT LOWEST TENDERER |
| 3 | L3₹2.7 Cr+₹28.9 L (11.9%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹2.7 Cr+₹28.9 L (11.9%) | L3 | Rejected-Finance NOT LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹4.0 L
Closing Date
12 Oct 2020, 6:00 pmClosed
CE (AF) WAC PALAM, DELHI CANTT-10
HQ CE (AF) WAC PALAM, DELHI CANTT-10
UPGRADATION OF OTM L IN ACCOMMODATION FOR OFFICERS AND AIRMEN AND IMPROVEMENT OF ELECTRICAL INFRASTRUCTURE AT AF STN PALAM TENDER I
2020_MES_368807_1
CEWAC/PAL/T-16/2020-21
Open Tender
Civil Works
Item Rate
365 days
GE (AF) PALAM
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE (AF) PALAM
₹4.0 L
Yes
17 Dec 2020
18 Aug 2020
14 Oct 2020
18 Aug 2020
12 Oct 2020
29 Sept 2020
19 Aug 2020 - 31 Aug 2020
Amount
B & R WORKS
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for (as in fllor, apron, plinth and path) including removal of debrish out side of MoD land, complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises, complete all as specified and directed.
Taking down rainwater pipes (any size), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
Taking down cement plaster on brick or concrete wall surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Dismantling of PVC water tanks of capacity exc 250 & n exc 500 litres, complete all as specified.
Taking up or down GI tubing (wall, ceiling, floor etc) with all connections and fittings of 15mm bore, complete all as specified and as directed.
Taking up or down GI tubing (wall, ceiling, floor etc) with all connections and fittings of 20mm bore, complete all as specified and as directed.
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and removal of debris at a distance exc 250m but not exc 500m and depositing where directed, complete all as specified and as directed.
Dismantling of Brick tiles or terracing tiles single layer on roofs laid dry or with cement mortar, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area not exc. 1.5 Sqm, complete all as specified and direcetd.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc. 1.5 Sqm but n exc 4.0 sqm, complete all as specified and direcetd.
M&L for 25 mm thick cement concrete 1:2:4, type B-0, (12.5 mm graded stone aggregate) as in sub base/ levelling course of floors, complete all as specified and directed.
M&L for Joint free anti-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (400mmx400mm) as in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L for joint free glazed ceramic coloured printed tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm(300x200mm/400 x 400mm/450x350mm) on vertical surface as in skirting or dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L for Joint free non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
S&F 35 mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both faces, complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
S&F 35mm thick 2nd class hardwood factory made glazed and skelton shutters open rebated and prepare to receive glass, guage, etc. (without sash bars), edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass/guage etc size of member etc; size members of shutters as specified in SSR part I Section-8 clauses 8.24(a); supplied and fitted to chowkhat, complete all as specified and directed.
S&F fibre glass reinforced plastic (FRP) door frame, three lagged of cross section 90 mm x 45 mm having single rebatd of 32x15 mm to receive shutter of 30 mm thickness, moulded with fire retardant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled withsuitable wooden block in all over frame. The frame shall be covered with fibre glassfrom all sides including MS stay at the bottom to steady the frame complete, all as specified and directed.
S&F factory made solid FRP door shutter , 30 mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire retardant grade unsaturated polyester resin mouled to 3 mm thick FRP laminated for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places forfixing of fittings, cast monolithically with 5 mm thick FRP panels and confirming to IS 14856-2000, complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, wire staples or beading etc, complete all as specified.
S&F Stainless steel butt hinges, heavy weight, 100mm long (IS :12817 marked), complete as specified and directed.
S&F butt hinges, medium weight, cold rolled, mild steel 100mm long (ISI marked), complete as specified and directed.
S&F extruded aluminium alloy handle, fabricated type, anodised, 150mm long (ISI marked), complete as specified and directed.
S&F extruded aluminium alloy handle, fabricated type, anodised, 125mm long (ISI marked), complete as specified and directed.
S&F aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long (ISI marked), complete as specified and directed.
S&F aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long (ISI marked), complete as specified and directed.
S&F aluminium alloy, 300mm long anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or excluded sections and fixing bolts and sliding bolts of excluded sections or cast aluminum alloy and fixed, complete all as specified.
S&F Pressed steel frames of size 125mmx60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, PCC 1:2:4 type B-0, (12.5 mm graded stone aggregate) for filling of hollow portion, complete as specified and directed.
S&F in repair floor door stopper of size 140mm long aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and direcetd.
S&F galvanized iron water tubing, ‘medium grade’ 15mm bore, with all fittings such as bend, tee, union etc., fixed complete to walls and ceilings or laid in floors and including cutting chase, pinning in making good to facings where required pointing in cement mortar 1:3 for concealed water tubing, complete all as specified & directed.
S&F galvanized iron water tubing, ‘medium grade’ 20mm bore, with all fittings such as bend, tee, union etc., fixed complete to walls and ceilings or laid in floors, complete all as specified & directed.
Refixing old steel tubing of 15mm bore and connections in new or old position (Walls, ceiling, floors etc.) including cleaning of pipe and necessary fittings, complete all as specified and directed.
Refixing old steel tubing of 20mm bore and connections in new or old position (Walls, ceiling, floors etc.) including cleaning of pipe and necessary fittings, complete all as specified and directed.
S&F in repair wash hand basins vitreous china flat back 550 x400 mm size white, first quality, with and including chromium plated waste grating 32mm size, China and plug and porcelain stopper, brackets of Mild Steel angle iron (35mmx35mmx5mm) of suitable size including two coat of synthetic enamel paint over a coat of primer over angle iron brackets complete to walls including discharge pipe of 32 mm dia PVC of 1.0 m length and one chromium plated pillar tap fancy type fixed to wash hand basin, complete all specified and as directed.
S&F in repairs, PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC bend flush pipe, complete all as specified and directed.
S&F in repair single lever basin mixer with popup waste system , Hot and Cold Facilites and 450 mm long braidaed hoses chromium plated complete all as specified and directed. Model No- DRC-37005B of make Jaquar or equivalent in Marc/Kohler.
S&F in repair bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repairs 15 mm angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed. Make: CON-059KN of jaquar or equivalent in Marc/Kohler.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450 mm complete all as specified and directed. MAKE: Prayag/Polytuf/Pearl.
M&L for cutting holes in brick walls in cement mortar for inserting/removing holdfast and making good dismantled portion in cement mortar 1:3 or cement concerte 1:2:4 type B-1 as required in exc half brick but not exc one bricks, complete all as specified and directed.
Dismantling of cast iron or reinforced or AC or PVC pipes, jointed in cement mortar and taking out of trenches, if required, internal dia of pipe 75/80mm, complete all as specified and directed.
Dismantling of cast iron or reinforced or AC or PVC pipes, jointed in cement mortar and taking out of trenches, if required, internal dia of pipe 100/110mm, complete all as specified and directed.
S&F 75mm bore cast iron waste and vent pipe in any length with or without ears fixed to walls including suitable clamps after every one mtr of interval, complete all as specified and directed.
S&F 100mm bore cast iron waste and vent pipe in any length with or without ears fixed to walls including suitable clamps after every one mtr of interval, complete all as specified and directed.
S&F 75mm bore cast iron waste and vent pipe in any length with or without ears laid in trenches or in floor, complete all as specified and directed.
S&F in repairs, cast iron bends with oval access doors(any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 75mm, complete all as specified and directed.
S&F in repairs, cast iron bends with oval access doors(any radius) diminishing pieces or tapers (larger bore measured), bore of pipe 100mm, complete all as specified and directed.
S&F in repairs, Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, bore of pipe 100mm, complete all as specified and directed.
S&F in repairs, Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, bore of pipe 75mm, complete all as specified and directed.
S&F in repairs, Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, bore of pipe 100mm, complete all as specified and directed.
S&F in repairs, Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, bore of pipe 75mm, complete all as specified and directed.
S&F in repairs Cast iron floor/Nahani trap with CP grating including jointing to waste pipe with run lead, dia of outlet 100mm set in cement concrete type B1 (1:2:4), complete all as specified and directed.
S&F in repairs, cast iron cowl of 100mm bore, complete all as specified and directed.
S&F in repairs, salt glazed stone ware gulley traps 150x150mm size square mouthed type ‘P’ including CI cover 150 x 150 mm complete all as specified and directed.
S&F PVC (SWR) pipes, 110mm dia, single socketed, in any length with solvent cement joints, fixed to wall or laid in trenches or in floors including suitable clamps after every one mtr of interval, complete all as specified & directed.
S&F in repair PVC(SWR) bends any radius, 110 mm bore, complete all as specified & directed.
M&L for 10 mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling surface, complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on wall surface, complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and fair with WPC as per manufacturers instructions on wall surface, complete all as specified and directed. Note: WPC shall be measured and paid separately
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for prepration of new plastered or unplastered surfaces and applying two coats of white wash on ceiling, complete all as specified and directed.
M&L for prepration of new plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
M&L for preparation of old decorated surfaces plastered or unplastered on wall including cornices pilasters by brooming down or steel wire brushing, scraping down and applying one coat of distemper oil emulsion, complete all as specified and directed.
M&L for preparing plastered or unplastered new surfaces on ceilings including brooming down or steel wire brushing, scraping down and applying three coats of white wash complete all as specified.
M&L for preparation of old decorated surfaces plastered or unplastered on ceiling including cornices pilasters by brooming down or steel wire brushing, scraping down and applying one coat of white wash, complete all as specified and directed.
M&L for preparing plastered or unplastered new surfaces on wall including brooming down or steel wire brushing, scraping down and applying two coat of distemper oil emulsion over a one coat of alkalic resistance paint, complete all as specified and directed.
M&L for preparing plastered or unplastered new surfaces on wall including brooming down or steel wire brushing, scraping down and applying two coats of cement base paint of approved colour and shade, complete all as specified and directed.
M&L for preparation of old decorated surfaces plastered or unplastered on walls including cornices pilasters by brooming down or steel wire brushing, scraping down and applying one coats of cement base paint of approved colour and shade, complete all as specified and directed.
M&L for prepration of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
M&L for prepration of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
M&L for prepration of new steel surfaces of any description n exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.10 Sqm each with tar or coal tar black paint, complete all as specified & directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area exc 0.10 Sqm but n exc 0.50 Sqm each with tar or coal tar black paint, complete all as specified & directed.
M&L for 100mm thick cement concrete 1:4:8, type D2, using 40mm graded stone aggregate as in sub base, surface finished even & rough to receive floor finishes, complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6, type C1, using 20mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:20 and surface finished even and smooth without using extra cement including making joint at 3m interval and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed.
M&L for 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws as in cup boards, shelves and palmet boxes, fixed in repair, complete all as specified and directed.
S&F in repair MS powder coated 20 mm dia curtain rod including wooden polished brackets and wooden polished end knobs fixed with plugs & screws, complete all as specified and directed.
M&L for double charged vitrified coloured tiles light shade 10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc, set and jointed in neat cement slurry and pointed with colour cement, laid over and including 15mm thick bedding layer in cement mortar 1:6, complete all as specified & directed.
M&L for double charged vitrified coloured tiles light shade 10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm on vertical surface as in skirting or dado etc., set and jointed in neat cement slurry and pointed with colour cement, laid over and including 10mm thick bedding layer in cement mortar 1:4, complete all as specified & directed.
M&L for gunniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm tied to existing reinforcement with nails, adhesive plaster grade for concrete and providing gunniting pressure 2.00/2.5 kg/sqm with admixture 1 part of cement and 3.5 part of sand with average thickness 40 mm and making the surface even including 15mm thick plastering in CM 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement including necessary form work to be carried out, complete all as spcified. Note.- Wherever reinforcement required will be measured and paid seperatly
S&F in repairs, Plastic water closet seat match to EWC, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device, complete all as specified and directed.
S&F in repairs, health faucet with double lock, one meter long brass chromium plated steel flexible hose pipe and wall hook complete all as specified and directed.
S&F in repairs single lever wall mixer with popup waste system, hot and cold facilites and 450 mm long braidaed hoses chromium plated, complete all specified and direcetd. Model No- FUS-29273 UPR of make Jaquar or equivalent in Marc/Kohler.
S & F in repair CP towel rail with lower hanger Make-AHS-1581H of Jaquar or equivalent in Marc/Kohler, complete all as specified and directed.
S & F in repair CP towel ring of Make-ACN-1121BN of of Jaquar or equivalent in Marc/Kohler, complete all as specified and directed.
S & F in repair CP Soap dish of Make-AKP-35731P of Jaquar or equivalent in Marc/Kohler, complete all as specified and directed.
S & F in repair CP toilet paper holder of Make-AKP-35751P of Jaquar or equivalent in Marc/Kohler, complete all as specified and directed.
S & F in repair CP tumbler holder of Make-AKP-35741P of Jaquar or equivalent in Marc/Kohler, complete all as specified and directed.
S & F in repair corner glass shelf with bracket of Make-ACN-1173 of Jaquar or equivalent in Marc/Kohler, complete all as specified and directed.
S&F rotationally moulded polyethylene water storage tank white colour 3 layer as per IS12701 (cylindrical vertical with closed top) hoisted & fixed in position of capacity 500 ltrs including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed.
M&L for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:6, complete all as specified and directed.
S&F over head shower with arm of size as per cat part No (but not less than 100 mm), round heavy casted 450 mm long 90 degree bend suitable and wall flange for rain shower compete all as specified . Make : OHS 1995 & SHA-49483 of jaquar or equivalent in Marc/kohler.
Extra over cast iron pipe sand fittings if lead joint is provided in lieu of cement joint for 100mm dia pipe, complete all as specified and direcetd.
Extra over cast iron pipe sand fittings if lead joint is provided in lieu of cement joint for 75mm dia pipe, complete all as specified and direcetd.
S&F cast iron covers for GT of size 300x300mm and thickness not exc 6mm as approved, complete all as specified and direcetd.
M&L for 25 mm thick PCC 1:2:4 using 20 mm graded stone aggregate over 250 thick cement concrete type D2 (1:4:8) with 40mm graded stone aggregate as in filling of sunken floors over a layer of APP based modified pre fabricated five layer 3mm thick and weighing not less than 3.6 kg/sqm water proofing membrane over a layer of bitumen cutback (85/25) grade applied hot (1.5 Kg/sqm) over 10mm thick plaster in cm 1:3 with WPC @ 3% by wt. of cement complete all as specified & directed. Note: Only plan area of sunken portion is measured.
S&F of mild steel 300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel, complete as specified and directed.
M&L for Cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth., complete all as specified and directed.
M&L for mild steel work as in bands, straps, supports or stays for rain water, vantilating pipes including bolts, if required, bolt hooks (stay), heavy for large gates; hook and pintle hinges; large hasp and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles, conforming to Fe-290 (Gde E-165), complete all as specified and directed.
Taking down existing tretment from roof such as tarfelt, cement plaster of any discription and any thickness, brick tiles, mud puska including flashing junction of parapet up to 4th storey of building and cleaning existing roof top surface by brooming, wire brushing and removal of debrish out side of MoD land, complete all as specified and as directed.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first course of 10mm thick rendering in cement mortar 1:4 on concrete surface using WPC as per manufacurer's instruction finished even and smooth without using extra cement, second course ie. surface shall be thoroughly wire brush, cleaned , washed, dried up properly and apply evenly a bitumen primer conforming to IS 3488@ 0.40 litre per sqm and applying bonding material 85/25 bitumen 1.2 kg/sqm, 3rd course of roofing membrane APP modified Polymeric membrane 3.0 mm thick of 3.60 Kg/ sqm weight consisting of five layers prefabricated with centre core of 160gms/Sqm polyster non woven fabric mat sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film before and after laying membrane sealing all the over laps 75mm on length side and 100mm on width side of membranes by torching as per manufacturer’s instructions by authorised applicator only, At the junction of roof and parapet wall a grove of 20 x 20 mm shall be made at the height of 100 mm and membrane shall be inserted and saled/fused by flame, complete all as specified and directed. Note: (i) WPC will be measured and paid separately (ii) Independent testing of membrane from approved lab for technical parameter shall be carried out by the contractor and test report shall be submitted to GE before claiming payment. (iii) Laying of APP membrane shall be carried out through company authorized applicator”.
M&L for PCC M-15, nominal mix, type B-1(1:2:4), using 20mm graded crushed stone aggregate as in PCC padding on roof kerbs or mud stops, rounded or chamfered on edges etc., including necessary form work, complete as specified and directed.
M&L for cement concrete tiles, machine pressed, factory made of size 25cmx25cm, 22mm thick, with grey cement and no pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Removing building materials etc. (other than spoil) to a distance of exc 1 KM, beyond the lead included in the rates, including loading, unloading and stacking at the destination, complete all as specified and directed.
S&F in repairs gun metal gate valve of 20mm bore with iron wheel head screwed both ends for iron pipe and fixed, including taking out unserviceable gate valve, complete all as specified and directed. Make- Leader/Kartar/Zoloto
S&F in repairs stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165, complete all as specified and directed.
M&L for post constructional ATT (Anti-Termite Treatment) as per IS 6313 part-III amended upto date along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified & directed.
Supply only integral water proofing compound (ISI marked), complete all as specified and directed.
S & F in repair, sheet glass 4.8mm thick ordinary quality and glazing with oil putty or wooden beads in squares not exc. 0.5 Sqm in each pane, complete all as specified.
S & F in repair, sheet glass 4.8mm thick ordinary quality and glazing with oil putty or wooden beads in squares exc. 0.5 Sqm in each pane, complete all as specified.
M&L for applying 3 mm (Average) thickness, JK/Birla wall care putty over old/ new wall plastered surfaces, preparatory to distempering/getting even and smooth surface, complete all as specified and directed.
S & F in repair, Figured glass, pin headed type, 4mm thick and glazing with oil putty or wooden beads in squares not exc. 0.5 Sqm in each pane, complete all as specified.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified.
Dismantling Asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified.
S&F window/ventilator section of frame 72 x 55 mm fixed to wall or concrete surfaces with screwing 100 mm long made of galvanised steel powder coated and section of shutter 47 x 20 mm mullion section 72 x 50 mm (base steel as per 513 D quality galvanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauge and wire mesh tie the shutter double door shutter with total coated grill/guard bars made of square bars 10 mm dia a 150 mm c/c horizontal spacing fixed in MS flat frame(12 x 6) fixed to window fame with screw including 4 mm thick sheet glass, 0.36 mm stainless steel wire cloth with 1.40 mm aparture necesary fitting and all builders hardware such as handle tower bolts & stay etc type -4000 series ref drg No - CEAF/STD -191/2014 Sheet 1/2 & 2/2, compete all as specified and directed.
M&L for Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified.
S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ clading to wall fixed with self tapping screws, complete all as specified and directed.
S&F pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof and eves boards fixed with self tapping screws, complete all as specified and directed.
M&L for Anodised aluminium snap grid frame work for false ceiling, size of grid 605x605mm, complete all as specified & directed.
M&L 6 mm thick non asbestos fibre cement building board fixed to frame work with screw, complete all as specified and directed. Note: Frame work shall be paid separately.
Dismantling timber scantling over 40 Sqcm and over in section, in any position (unframed work), complete all as specified.
Dismantling structural steel work including rafter, purlins, doors, gates but excluding framed truss etc., complete all as specified.
M&L for Rolled mild steel work in main and cross beams, hip and jack rafters; purlins where connected to comman rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-410-W (Gde- E-250) quality-B, complete all as specified & directed.
M&L for Mild steel work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc., wind ties for roof including securing bolts etc. including all necessary drilling, bolting or riveting etc. and similar work, conforming to Fe-290 Gde E-165, complete all as specified and directed.
M&L for machine cut polished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, laid over and including 20mm thick screed bed in cement mortar 1:4, rubbing, grinding and polishing to achieve mirror finish, complete all as specified and directed.
M&L for PCC M-15, nominal mix, type B-0(1:2:4), using 12.5mm graded crushed stone aggregate for fixing hold fasts and clamps etc., including necessary form work, complete as specified and directed.
M&L for brick work with sub class "B" brick (old size), straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with sub class "B" brick (old size), straight or curved on plan exc 6 m mean radius and built in cement mortar 1:4, complete all as specified and directed.
M&L for brick work with sub class "B" brick (old size) straight or curved on plan any radius in half brick thick wall and built in cement mortar 1:4, complete all as specified and directed.
S&F in repair 25 mm bore Anodised aluminium alloy curtain rod with teak wood brackets, knob, stops, rollers etc, complete all as specified and directed.
Demolition of stone or brick masonry built in cement mortar including all quoins, arches etc.but excluding ashlar facing, dressed stone work etc, complete all as specified and directed.
M&L for TMT mild steel bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for as in roof slab of toilets and bathrooms (Reinforcement cut as required to facilitate demolition) including removal of debrish out side of MoD land, complete all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces, complete all as specified and directed.
M&L for cement concrete, 1:5:10, type E-2 using 40mm graded crushed stone aggregate as in foundations, filling, mass concrete and sub base, complete all as specified and directed.
S&F of stop valves, 15mm bore, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed.
S&F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe (Minimum weight 40gms), including fixing to steel pipe or union, complete all as specified and directed.
S&F in repairs, Vitreous Chinaware squatting pan, orissa pattern size 580mm x 440mm with integral foot rests, white, front or back inlet, including provision of cement concrete, making connections to trap and to flush pipe etc. and making good to floors, complete all as specified.
S&F in repairs, Vitreous China wash down water closet pan (pedestal pattern), white with cast iron ‘P’ or ‘S’ trap, fixing with screws of suitable size, plastic seat cover, white closed pattern with flat bottom and cover, making connections to trap and to flush pipe, fixing flushing cistern etc. and making good to floors, complete all as specified and directed.
S&F in repairs, cast iron ‘P’ or ‘S’ trap, bore of pipe 100mm, complete all as specified and directed.
S&F in repair towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depth in hard/dense of soil and getting out, complete all as specified and as directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified.
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in concrete bed to drain pipes 150mm bore including packing under and hunching against the side of pipe after they are laid and testing of pipe, complete all as specified and directed.
S&F Reinforced cement concrete pipes 150mm bore, class NP2, laid and jointed with collars, complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 150mm, complete all as specified and directed.
M&L for cement concrete, 1:3:6, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling, mass concrete and sub base, complete all as specified and directed.
M&L for TMT mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified.
M&L for Precast cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes/drain etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match, complete all as specified.
M&L for prepration of new plastered or unplastered surfaces of wall and applying two coats of exterior emulsion paint (apex or equivalent) white or tinted over a coat of primer of same make including scaffolding arrangment, trestles, ladder up to two/three storey etc, complete all as specified and directed.
Providing and fixing factory made uPVC white colour sliding window area exceeding 2 sqm each three track made of extruded profiles with wall thickness of 2.3mm (+ 0.2mm) window profile with hollow section with multi chamber frame (88mmx52mm), T profile sliding sash (42x67mm) sliding mesh sash(42x57mm) sliding inter lock (one vertical length in each shutters) (45.5x28mm) glazing bead(24x16mm) will be mitred cut and fusion welded at all corners including railing in holes for fixing of hard ware and drainage of water etc, making arrangement for fixing of hardware EPDM gasket 1.2 +0.2mm thick galvanised steel frame (30x18mm) 2Nos sliding sash (30x18mm) sliding mesh sash (26x10mm) profile to be inserted in required profile frame wil be fixed to the wall with 8x100mm long fastenhers. Hardware; Touch lock of zinc alloyed (white powder coated) steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and required accossieries. complete all as specified and directed Note : i) The unit rate quoted by the contractor excluded the cost of glass and includes all other connected accesories. ii) Net opening will be measured for payment purpose
Providing and fixing factory made uPVC white colour sliding window area not exceeding 2 sqm each three track made of extruded profiles with wall thickness of 2.3mm (+ 0.2mm) window profile with hollow section with multi chamber frame (88mmx52mm), T profile sliding sash (42x67mm) sliding mesh sash(42x57mm) sliding inter lock (one vertical length in each shutters) (45.5x28mm) glazing bead(24x16mm) will be mitred cut and fusion welded at all corners including railing in holes for fixing of hard ware and drainage of water etc, making arrangement for fixing of hardware EPDM gasket 1.2 +0.2mm thick galvanised steel frame (30x18mm) 2Nos sliding sash (30x18mm) sliding mesh sash (26x10mm) profile to be inserted in required profile frame wil be fixed to the wall with 8x100mm long fastenhers. Hardware; Touch lock of zinc alloyed (white powder coated) steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and required accossieries. complete all as specified and directed Note : i) The unit rate quoted by the contractor excluded the cost of glass and includes all other connected accesories. ii) Net opening will be measured for payment purpose
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and directed.
M&L for 14-16 mm thick machine cut Udaipur green marble (table rubbed and polished) stone slab as in floor, steps, jambs, pillars, window cill, cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble laid 15mm screed bed in cement mortar 1:4, complete all as specified & directed.
M&L for rounding to edges of kota stone slabs, marble slabs etc. on edge, such as in steps, cooking platform and other similar situations, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving exc 15cm thick above or below ground level including removal of debrish out side of MoD land, complete all as specified.
M&L for polished kota stone slab 14 -16 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab, laid over and including 10mm thick rendering in cement mortar 1:4, rubbing, grinding and polishing to achieve mirror finish, complete all as specified and directed.
S&F for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thick , M-35 grade including laid over 50mm thick sand cushioning, complete all as specified and directed.
S&F for factory made pre-cast cement concrete kerb stone of design mix M-35 grade size 900mm length, 300mm height, bottom width 125mm and top width 80mm, kerb stone shall be manufactured in joint less moulds on vibration compaction table and finished smooth as per required shape, size and pattern and setting in poistion in cement mortar 1:4, jointing and pointing with cemnet motar 1:2, complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement, complete all as specified and directed.
M&L for prepration of new or previously untreated plaster or concrete surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of primer, complete all as specified.
S&F in repair vitreous china urinal half stall type white or coloured with grating and union for discharge pipe etc, complete all as specified and directed.
S&F for low density polyethylene (LDPE) pipe of pressure rating 6kgf/Sqcm, 32mm dia, suitable for coupling 32mm & 40mm dia, complete all as specified and directed.
EXTERNAL WATER SUPPLY
Supply and laying and testing in replacement GI tubing medium grade ISI Marked with all fitting laid in trenches or floor /wall for bore of pipe of following sizes complete all as specified and directed. Make- Tata/Jinda/Prakash Surya
(a) 15 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(e) 80 mm bore
(f) 100 mm bore
S&F in replacement gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed, including taking out unserviceable gate valve of pipe of following sizes complete all as specified and directed by Engineer-in-Charge. Make- Leader/Kartar/Zoloto
(a) 15 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50mm bore
Supply and fixing CI special fittings of any size, any type ISI marked as required at site such as bends, Tees, short pieces, tapers, collers, junctions etc for spigot and socketed/flanged pipe upto 150mm bore, complete all as specified and directed by Engr-in-Charge.
S&F in repair 15mm bore Self closing taps of cast iron or malleable cast iron, galvanised, screwed for iron pipe and fixed, complete all as specified and directed.
M & L for augering of holes in true horizontal position under road (by trenchless method) by means of mechanical rig covering in route up to 1.5 mtr deep and not exceeding 30mtr long for passing the water pipe lines of up to 150mm bore complete all as specified and directed by Engineer-in-Charge.
INTERNAL WIRING
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, complete all as specified and directed.
Taking down unservesiable/Old DBs/AC Boxes etc complete all as specified and as directed.
Taking down unservesiable sub main wiring with conduits/battens etc complete all as specified and as directed.
M & L for Point wiring for the following with single core PVC insulated but unsheathed 1.5 Sqmm FRLS multistranded copper conductor cable (with proper colour code red, black & green) 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories concealed in wall including pressed steel boxes with 3 mm thick laminted bakelite sheet for mounting switches, sockets, fan regulators, etc and earth wire single core PVC insulated but unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLS cable as continuous earth wire connecting to common earth dolly complete in concealed wiring system all as specified and directed by Engr- in- Charge Note :- i) Cost for cutting, chasing and making good to existing surfaces shall deemed to be included in the quoted rate.
(a) One light point controlled by one switch one way
(b) One fan/exhaust fan point controlled by one switch.
(c) One socket outlet 5 Amp controlled by one switch on independent board
(d) One 3 pin 5 Amps socket out let point on the same board controlled by one switch complete
(e) One light point controlled by two 2 - ways switches
All as per Srl item No 4.40 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed.
M&L for modular point wiring for following with single core PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia ISI marked with all conduit fittings and accessories, concealed in wall and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm FRLS (Nominal area), complete all as specified. Note :- i) Modular metal flush boxes shall be measured and paid under respective item. ii) Cost for cutting, chasing and making good to existing surfaces shall deemed to be included in the quoted rate.
(a) One light point controlled by one switch one way
(b) One fan/exhaust fan point controlled by one switch.
(c) One socket outlet 5 Amp controlled by one switch on independent board
(d) One 3 pin 5Amps socket out let point on the same board controlled by one switch complete
(e) One bell point controled by one bell push 5 Amps
(f) One light point controlled by two 2 - ways switches with cables 1.5 sq. Mm
All as per Srl item No 4.60 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed.
All as per Srl item No 4.60 here-in-before but one power point 6 pin 15 Amps socket out let with 4.0 Sq mm stranded copper conductor cable PVC insulated including earth wire 4.0 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed.
S&F modular white cover plate with frame 2 module, complete all as specified and directed by Engineer-in-charge.
S&F modular white cover plate with frame 3 module, complete all as specified and directed by Engineer-in-charge.
S&F modular white cover plate with frame 4 module, complete all as specified and directed by Engineer-in-charge.
S&F modular white cover plate with frame 8 module, complete all as specified and directed by Engineer-in-charge.
S&F of modular metal flush boxes thickness as per OEM instructions 1 or 2 module, complete all as specified and directed by Engineer-in-charge.
S&F of modular metal flush boxes thickness as per OEM instructions 3 module, complete all as specified and directed by Engineer-in-charge.
S&F of modular metal flush boxes thickness as per OEM instructions 4 module, complete all as specified and directed by Engineer-in-charge.
S&F of modular metal flush boxes thickness as per OEM instructions 8 module, complete all as specified and directed by Engineer-in-charge.
S&F of modular switch 1 way 6 Amps one module complete all as specified and directed by Engr-in-Charge.
S&F of modular switch 2 way, 6 Amps one module complete all as specified and directed by Engr-in-Charge.
S&F of modular socket 6 Amps 2/3 Pin combined 02 module complete, all as specified and directed by Engr-in-Charge.
S&F of modular switch one way 16 Amps, one module complete, all as specified and as directed by Engr-in-Charge.
S&F of socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete all as specified and as directed by Engr-in-Charge.
S&F of ceiling rose, surface type, 65mm x 50mm, 3 terminal complete all as specified and as directed by Engr-in-Charge.
S&F in replacement electric bell, multi music type, 230 volt AC, single pole, complete, all as specified and as directed by Engr-in-Charge.
S&F of modular bell push 6 Amps one module complete all as specified and as directed by Engr-in-Charge.
S&F of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and as directed by Engr-in-Charge.
S&F of switch piano flush type 5 Amps, single pole one way complete, all as specified and directed by Engr-in-Charge.
S&F of switch piano flush type 5 Amps, single pole two way complete, all as specified and directed by Engr-in-Charge.
S&F of socket out let 2-in-1, 5 pin 5 Amps, flush type complete, all as specified and directed by Engr-in-Charge.
S&F of switch piano flush type single pole one way 15 Amps complete, all as specified and as directed by Engr-in-Charge.
S&F of socket outlet 2 in 1, 6 pin 5/15 Amps, flush type complete all as specified and as directed by Engr-in-Charge.
S&F in replacement Indoor decorative LED battens- integrated type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete all as specified and directed by Engr-in-Charge. Make - C&S cat part No LTTB4F20WLED/W or equivalent in Philips/Havells.
S&F in replacement Indoor decorative LED battens- integrated type 10 watt 2 feet white fixture with extruded aluminium body, suitable for LED tube 10 watt , bipin holder, connector block, LED rod 10 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete all as specified and directed by Engr-in-Charge. Make - C&S cat part No LTTB2F10WLED/W or equivalent in Philips/Havells.
S&F in replacement LED bulb 09 watt with B22 base in replacement of CFL 11/15 watt fixed in pendent holder /bulk head complete all as specified and directed. Make - C&S cat part No LTHPLEDLAMP 09W/B22 or equivalent in Philips/Havells.
S&F in replacement Decorative LED wall bracket light fitting made up of Polycarbonate suitable for B-22 base including one No 12 watt LED bulb, complete all as specified and directed. Make- Halonix cat part No. HLWB-01-B22 or equivalent in C&S/Philips/Polycab.
S&F in replacement of Indoor decorative LED surface down light 12 Watt complete with all accessories internally pre wired and including connecting up with twin core copper conductor cable complete all as spd and directed by Engr-in-Charge. Make: C&S cat part No LTCRSUR12HPLEDRND/W or equivalent in Philips/Havells/Polycab.
S&F in replacement of LED bldg security light 45 watt IP 66 with internally prewired incl electronic driver and connecting up with three core flexible copper condutor 1.5 sqmm cable complete all as specified and directed. Make C&S cat Pt No LTESS45WLED/LS or equivalent in Philips/Havells/Polycab.
S&F in replacement sheet metal enclosure for distribution board SPN (when MCBs to be used ) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail with IP 43 rating complete all as specified and as directed by Engr-in-Charge.
S&F in replacement sheet metal enclosure for distribution board SPN (when MCBs to be used ) 12 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail with IP 43 rating provn of incomer MCCB TP and outgoing MCBs SP/TP, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement vertical type load line distribution board, double door, 4 way , IP 43 IK09 AC, 3 phase, 415 volts, TPN bus bar 250 Amps rating and earth bar & din rail with IP 43 rating complete all as specified and as directed by Engr-in-Charge. Make : Legrand Cat Pt 5077 45 or equivalent in Havelles/L&T.
S&F of MCCB, 3 pole 100A, 16KA, 415Volts complete with connections all as specifiedd and directed by Engr-in-Charge.
S&F in replacement MCB SPN 32A ,10KA, 230 V 'C' series complete with connections all as specified and directed by Engr-in-Charge. Make : Legrand /Havelles/L&T.
S&F in replacement MCB SP 40A ,10KA, 230 V 'C' series complete with connections all as specified and directed by Engr-in-Charge. Make : Legrand /Havelles/L&T.
S&F in replacement MCB SP 6-32A ,10KA, 230 V 'C' series complete with connections all as specified and directed by Engr-in-Charge. Make : Legrand / Havelles/L&T.
S&F in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB single pole and neutral 20 Amps complete all as spd and directed by Engr-in-Charge .
S&F of 5 star ceiling fan 1200mm sweep, 230 volts (single phase) including provision of stepped type electronic fan regulator to match with the switch boards and flexible copper cord of size 1.5 sqmm of required length from ceiling rose to fan including connection & provn of MS fastner for hanging of ceiling fan complete all as specified and directed by Engr-in-Charge. Make: Havells Cat Part No ES-50 Premium or equivalent in Crompton/Bajaj
M&L for sub main wiring with undermentioned run of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 V grade IS-694 drawing into and including rigid non metallic PVC conduit, medium grade ISI marked ( not less than 25 mm) with all conduit fittings & fixing accessories for concealed in wall/ ceiling or surface incl the specified run of specified size earth continuity conductor of similar type of cable complete all as spd and directed by Engr-in- Charge. Note- The undermentioned runs of single core cable and specified earth continuity conductor and revelent conduit with fitting acessories will be measured as one run.
(a) 2 run of 6 sq mm and one run of 6 sq mm
(b) 2 run of 4 sq mm and one run of 4 sq mm
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge.
S&F in replacement exhaust fan with louvers metallic body, complete 300mm sweep 230 volts, single phase , AC supply complete with nuts, bolts and washers size of the bolts 06 inch long fastener 6mm dia embedded in the wall including provisioning of flexible cord copper of size 1.5 sqmm three core from ceiling rose to exhaust fan for giving connection and providing continous earthing connection complete all as specified and direted by Engr-in-Charge.
Taking down ceiling fans of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades and depositing to MES store yard complete all as specified and directed by Engr-in-Charge.
S&F of AC single phase tamper proof static energy meter of accuracy class 1.0, 240 V 50 Hz with Backlit LCD display of rating 10 - 60 A (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, tamper logging, optical communication port display in absence of power with transparent hinge type box, complete all as specified and directed by Engr-in-Charge.
S&F of Thermoplastic (Polycarbonate/Polystyrene) , IP65 as per IEC 60529 , corrosion proof, suitable for Meter box lid screws made of stainless steel V2A, internally embedded gasket for lid and enclosures, metric size knock outs for cable entry from top and bottom with transparent Hinged lid . DB should be able to adapt any make of MCB or din mountable equipement and tested as per as IEC 60439-3, fit for the new standard IEC 60 364-4-41, glow wire test IEC 695-2-11: 750C, flame retardant, self -extinguishing protection against mechanical load IK 08 (5 Joule) in accordance with IEC 62262 and enclosure dimension should be 217x253x115mm (LxBxH), complete all as specified and directed by Engr-in-Charge. Makes: Hensel cat No - KG 9003 IN or equivalent in Schneider/L&T.
M&L of GI pipe light grade 40 mm dia bracket not less than 1.5 Mtr long and bent to a shape for fixing of street lights incl 2 Nos MS clamps made out out of 25x6 mm MS flat incl 04 Nos fully threaded bolts and nuts fixing on wall etc complete all as spd and directed by Engr-in-Charge .
S&F of Electric storage type water heater (Geyser) of 25 litres capacity, 230 Volts single phase, BEE 5 star rated complete with all accessories like pressure release valve, nuts, bolts, washers etc and 02 Nos. of 450 mm long flexible stainless steel pipes for hot & cold water connections, complele all as specified and directed by Engr-in-Charge. Make: Havells Cat Part No GHWAMGTWH025 or equivalent in Crompton/Bajaj
Shiv Shankar Nirman Co.
M/S Chhavi Constructions Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .