| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr Quoted ₹3.6 Cr | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹3.6 Cr+₹1.8 L (0.49%)Rejected-Finance | ₹3.6 Cr+₹1.8 L (0.49%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹4.0 Cr+₹33.4 L (9.22%)Rejected-Finance | ₹4.0 Cr+₹33.4 L (9.22%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹4.3 Cr+₹68.5 L (18.9%)Rejected-Finance | ₹4.3 Cr+₹68.5 L (18.9%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹4.5 Cr+₹83.7 L (23.1%)Rejected-Finance 11 A KUTCHERY ROAD BALUGANJ AGRA 282001 UP | AGRA | UTTAR PRADESH | 282001 | ₹4.5 Cr+₹83.7 L (23.1%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹4 Cr
EMD Value
₹4.8 L
Closing Date
9 Mar 2022, 6:00 pmClosed
HQ Chief Engineer Lucknow Zone
Chief Engineer Lucknow Zone 17 Cariappa Road Lucknow-226002
ADDITION/ALTERATION CUM SPECIAL REPAIR OF OTM ACCN AT AGRA
2022_MES_499622_1
CELZ/AGR/T-35 OF 2021-22
Open Tender
Civil Works
Item Rate
670 days
HQ Chief Engineer Lucknow Zone
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE (West) Agra
₹4.8 L
Yes
24 May 2022
5 Jan 2022
11 Mar 2022
5 Jan 2022
9 Mar 2022
26 Feb 2022
Amount
B/R WORKS Dismantling cement( corrugated ,semicorrugated ) sheets in roof covering including L type or J type hooks or cranked bolts etc complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet for ridges 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L,1 mm thick plain galvanised mild steel sheeting in ridges ,hips,valley guttres, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 gr/ Sqm complete all as specified and directed.
Dismantling wall and ceiling boards( fibre pulp, insulation etc.) or insulation board /slabs/blanket any thickness including cover fillets complete all as specified and directed.
S & F Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to center complete all as specified and directed.
M&L for 4 mm thick non asbestos fibre cement building designer boards fixed in ceiling or laid/inserted to timber/GI/aluminium frame complete all as specified and directed.
S&F solid PVC Wall lining consisting of 5mm thick plain but single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.
Taking down wooden roof truss exc 4 m but n.exc 8 m rafters or trussed beams span complete all as specified and directed.
M&L MS roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam ,tee,angle,channel or flat section ) including distnace pieces cleats etc confirming to Fe290 grade E-165 complete all as specified and directed.
Dismantling timber frame work scantlings 40 Sq. cm and over in section and in any position complete all as specified & directed.
S&F MS rolled section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc confirming to Fe 410 W grade E-250 quality-A complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillar etc complete all as specified and directed.
M&L brick work with fly ash bricks ( old Size) in cement mortar (1:6) straight or curved on plan exceeding 6.00 mtr mean radius complete all as specified and directed.
Demolition Cement concrete (unreinforced) of any description and any position not otherwise specifically provided complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in bed block and coping and benching embedding of hold fast etc complete all as specified and directed.
Demolition Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 50 mm thick (1:3:6) type C-1 using 20 mm graded stone aggregate , plinth protection finished even & smooth without extra cement complete all as specified and directed.
M&L100 mm thick PCC 1:2:4 type B2 using 40 mm graded stone aggregates as in floor complete all as specified and directed.
M&L forming construction joint 30 mm deep 10 mm wide saw cut filled with sealing compound grade A complete all as specified and directed.
M&L forming dummy joint 20 mm deep 10 mm wide saw cut filled with sealing compound grade A complete all as specified and directed.
M&L PCC 1:2:4 type B-0 using 12.5mm stone aggregate in fillets junction of roof and parapet wall caving slightly chamfered or rounded complete all as specified and directed.
Taking down cement plaster on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on any faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on any faces of brick work in cement mortar 1:4 finished even and smooth without using extra cement. with liquid water proofing compound complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L two coats of oil emulsion distemper on wall newly surfaces by applying 2 mm thick J K White putty including preparation of surfaces complete all as specified and directed.
M&L two coats of oil emulsion distemper on old wall surfaces by applying 1 mm thick birla putty including preparation of surfaces and removal of eixting treatment complete all as specified and directed.
M&L for three coats of white wash on new plastered surface on walls including prepration of surfaces complete all as specified and directed.
M&L for one coat of white wash on old plastered surface on walls ,ceiling including prepration of surfaces complete all as specified and directed.
Preparing newly plastered surfaces and applying two coats of cement base paint over a coat of priming with alkali resistant paint complete all as specified and directed.
Preparing old decorated surfaces and applying one coats of cement base paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior paint silicon based over a coat of water based suitable primer as a base coat as per manufacturer's instructions complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
S & F steel windows with side hung shutters with using Box type steel window without glazing bars including projected box type hinges, steel handle, steel peg stay etc dovetailed or welded complete all as specified and directed.
S & F steel windows with side hung shutters using Box type steel window with glazing bars including projected box type hinge, steel handle, steel peg stay etc dovetailed or welded complete all as specified and directed.
S & F steel windows for industrial buildings fixed type with glazing bar complete all as specified and directed.
S & F steel ventilators with top hung shutter & glazing bars hinges, steel peg stay complete all as specified and directed.
S&F framed work such as guard bars, grills etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) exc 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed.
Taking down shutter exc 1.0 Sqm and not exc 2.00 Sqm each complete all as specified and directed.
M&L for 35 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass or gauge etc divided into squares with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, provided with stiles and rails as specified in SSR Part-I Section-8 clause 8.20 (a) fixed to chowkats complete all as specified and directed.
M&L for 40 mm thick Flush shutter, solid core contruction, with block board core and plywood face panels commercial type on both side fitted to chowkats complete all as specified and directed.
S&F Soild PVC door frame of size 50 mm x 47 mm made out of 5 mm plain coloured PVC sheet, reinforced with MS square tube complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter 28 to 30 mm thick(stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specifications & drawings shown in section 8 of SSR Part II complete all as directed.
M&L Pressed steel frames 125 mm x 60 mm x 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike plate,etc complete including PCC (1:3:6) type C-0 (using 12.5 mm graded stone aggregate) as in filling hollow portion of frame complete all as specified and directed.
M&L Pressed steel frames 105 x 60 x 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike plate,etc complete including PCC (1:3:6) type C-0 (using 12.5 mm graded stone aggregate) as in filling hollow portion of frame complete all as specified and directed.
S & F galvanized mild steel wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
M&L for 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for 3 mm thick sheet glass figured glass,pin head type and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 (using 20 mm graded stone aggregate) for embedding of hold fast etc including disturbed surface of existing position complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface over 10 cm width or girth including preparation of new or previously untreated steel surfaces complete all as specified and directed.
Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
S&F mild steel work as in bands , straps ,holdfast , hooks for hanging fans , and similar works confirming to Fe 290 , gde E-165 complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, and fixed (Size of hinges in 100 mm) complete all as specified and directed.
S&F 200 mm long Aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long aluminium handles, cast type, anodized and fixed complete all as specified and directed.
S & F mild steel sliding door bolt 300 mm long stove enamelled black with bright bolt not less than 16 mm dia with and including and minimum of 6 bolts and nuts four on bolt plate and two on staple plate and fixed etc complete all as specified and directed.
S&F in repairs Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wooden beads complete all as specified and directed.
S&F Powder coated aluminium frame for doors, windows ventilators with one or more rebate including jointing cleats, screws, for fixing etc complete all as specified and directed.
S&F Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed.
S&F Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed.
S&F Powder coated aluminium grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc, aluminium section 15 micron thick anodizing complete all as specified and directed.
S&F 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination , fixed with screws to timber/ aluminium frame work and sealing edges of board with PVC beading by chemical adhesive complete all as specified and directed.
S&F 4.8 mm thick sheet glass ordinary quality and glazing not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F 4.8 mm thick sheet glass ordinary quality and glazing exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F mortice lock, vertical type of size 100 mm with mild steel body 4 lever complete all as specified and directed.
S&F precast cement concrete louvers and jallies 25 mm thick (measured solid ) type Bo (1:2:4) 12.5 mm graded stone aggregate set in cement mortar 1:4 including all moulding but including frame complete all as specified and directed.
Roughening of surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for 20-25 mm thick machine cut kota stone slab flooring over 20mm thick cement screed bed in cement mortar 1:6 , laid and jointed with grey cement slurry mixed with pigment to match the shade of stone slab including cutting, grinding, rubbing and polishing complete all as specified and directed.
All as per Item No. 74 above but in skirting over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic colour tiles joint free 7 to 8 mm thick (Square /rectangle) area of each tile excedding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
All as per item No-77 above but on verticle surfaces such as skirting/dado over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for vitrified dark shade ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for vitrified dark shade ceramic tiles on vertical surface 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tile 300 mm x 200 mm x 7 mm thick jointed and pointed with white or coloured cement over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Taking up or down 20 mm bore dia steel tubing and connections, including removal to store/ site complete all as specified and directed.
Taking up or down 15 mm bore dia steel tubing and connections, including removal to store/ site complete all as specified and directed.
S&F 15mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F tubes `medium grade' galvanised with all fittings and fixed complete to wall 20 mm bore complete all as specified and directed.
M&L in repair gun metal ,globe or gate valve 20 mm with iron wheel head ,screwed both ends for iron pipe complete all as specified and directed.
S & F in repair CP Bib taps fancy type cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed (15 mm bore dia of pipe ) complete all as specified and directed.
S & F in repair CP Stop valves fancy type ( angle valve) cast copper alloy screwed down high pressure with crutch or but terfly handle screwed both ends for iron pipe or for unions and fixed ( 15mm bore dia of pipe ) complete all as specified and directed.
S & F in repair 15mm bore dia Pillar taps fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs brass CP mixer ( wash basin /wall )15 mm bore for mixing hot & cold water screwed down for iron pipe or any type of pipe and fixed in position and making good disturbed portion complete all as specified and directed.
S & F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe complete all as specified and directed.
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F in repair shelf PTMT fixed with and incl CP brass screw and wooden / plastic cleats ( minimum weight 300 gm) complete all as specified and directed.
S&F in repairs Vitreous China wash hand basin white flat back size 550 mm x 400 mm including brackets , waste pipe,complete all as specified and directed.
S&F in repairs Rotational moulded polyethylene water storage tanks with cover & 20mm ball valves high pressure of PTMT with epooxy coated aluminium rod & high density plastic ball (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I (Capacity in litres 500) complete all as specified and directed.
S&F in repair kitchen sinks with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white (excl fixing bolt flushing cistern and flush pipe ) fixed in repairs complete with seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F in repairs vitreous China Orrissa pan with integral foot rest size 580 mm x 440 mm white with ‘P’ or ‘S’ trap front or back inlet and foot rests any pattern fixed in repair all as spfd including concrete bedding complete all as specified and directed.
S&F in repairs low level flushing cistern of capacity 10 litre ISI marked complete with inlet ball valve , and handle including bracket of Commander/Hindware/ complete all as specified and directed.
S&F in repair 125 mm PTMT Grating with waste hole minimum weight 40 gm complete all as specified and directed.
S&F in repair Stainless steel toilet paper holder recessed type complete all as specified and as directed
S & F in repair Chromium plated brass hand ablution health faucet with and including 1.50 mtr long flexible tube fancy type with necessary brass nuts & rubber washers, cover with chromium plated spring complete all as specified and directed.
S&F in repair soap dish, brass, chromium plated,size 100 mm X 60 mm, fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
S&F in repair chromium plated tubular towel rail 20 mm dia D type 60 cm long between flanges complete all as specified and directed.
M&L for taking down/dismantling of existing roof treatment of any description such as PCC Padding/ Coba treatment/ mud phuska/Lime conc terracing including screed bed ,brick tiles etc. Hessian base felt/tar felt etc. (any type and thickness) complete all as specified and directed.
M&LCutting out cracks to 'V' section in existing roof or terraces cleaning out, wetting grooves and suppling and filling cement mortar in cement mortar (1:3) complete all as specified and directed.
M&L providing PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in bed plates coping, padding without extra cement smooth finish complete all as specified and directed.
Material and labour for applying 10 mm thick plaster in cement mortar 1:4 including water proofing compound @ 3% by weight of cement complete all as specified and directed.
Material and labour for water proofing treatment of roof slab as specified here- in- after complete and directed . ( Note- Each stage shall be passed by AGE & Approved by GE) (a) Applying a priming coat with bitumen primer @0.5 Kg/Sqm including cleaning surfaces. (b) Applying a hot blown bitumen grade 85/25 @ 1.25 Kg/sqm (c) Laying polymeric water proofing membrane APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed. (d) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and sand in confirming to Zone II in dry condition will be dusted over the bitumen @1.00 Kg/Sqm.
M&L Cutting groves in brick wall 75 mm wide and 65 mm deep and shaping horizontal face 'v' groove with cement mortar (1:3) complete all as specified and directed.
Material and labour PCC 1:2:4 type B-0 using 12.5 mm stone aggregate in fillets junction of roof and parapet wall caving slightly chamfered or rounded including water proofing compound @3% by weight of cement complete all as specified and directed.
M&L for 40mm thick brick tiles laid on cement mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement including over 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M& L washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1: 4 ( 1 cement : 4 coarse sand ) furrowing the under layer with scratching tool applying cement slurry on the under layer @ 3 Kg of cement per square metre top layer 15 mm cement plaster 1:1 1/ 2 : 2 (01 cement 11/2 corse sand : 2 stone chipping 10 mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings (payment for providing grooves shall be made separately) complete all as specified and directed.
Forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens nailed to the under layer including removal of wooden battens repair to the edgs of panels and finishing the groove complete all as specified and directed.
Dismantling structural steel work including doors ,gate but excluding framed truss etc complete all as specified and directed.
S&F1.25 mm thick of laths rolling shutters gear operated type with chain wheel and hand chain including top cover anchoring rod hasp and staple and one shop coat of primer erected in position complete all as specified and directed.
S&F safety lever lock mild steel with 4 levers for rolling shutters complete all as specified and directed .
M&L in repair machine pressed coloured chequered tiles 25 cm x 25 cm x 25 mm thick set, jointed & pointed in grey cement with pigment including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed .
S&F in repair 110 mm bore PVC (SWR) Soil waste, rain water pipe and vent pipes single socketed in any length with rubber ring joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed .
S&F in repair 110 mm bore PVC (SWR) bends of any radius with access door including making good disturbe portion to match the existing complete all as specified and directed .
S & F in repair 110 mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed .
S & F in repair 75 mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed .
S & F in repair PVC (SWR) Bend any radious of 75 mm dia complete all as specified and directed .
S & F in repair PVC (SWR) Junction (Single 'T' ) equal or un equal of 75 mm dia complete all as specified and directed.
M & L in repair PVC (SWR) Gully traps125/110 mm setting and jointing with solvent cement complete all as specified and directed .
S & Fin repair PVC (SWR) Vent Cowl 110 mm dia complete all as specified and directed
M&L for granite stone 12 to 15 mm thick glazed (table rubbed and polished) fixed as in platform and the like set in cement mortar 1:4 and pointed with white cement (1:2) using marble dust with admixture of pigment to match the shade of slab and exposed edges rounded with & including screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed
M&L for applying one coat of epoxy resin (Fair Bond EP) on old concrete surfaces of ceiling and beam chhajja stair case etc @ 0.30 Kg/Sqm including 25 mm thick (average thickness) of cement and sand (fine grit) ratio 1:3 mixed with chloride free spray concrete average plastisizer (spray rate) as per manufacture instruction with guiniting machine pressure capacity not less than 5 Kg per Sqcm and finished the surfaces even and smooth complete all as specified and directed.
M & L rendering cement plaster 10 mm thick in cement mortar 1:4 on concrete surfaces as in ceiling and finished the surface fair and even without using extra cement complete all as specified and directed.
M & L for three coats of white wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
DRAIN WORK Excavation in trenches in soft/loose soil not exceeding 1.5m depth and n.exc 1.5m width for foundation etc or for shafts ,wells, cesspit , manholes ,pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth getting out complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for surface channels, bed of drains incl forms/moulds etc. complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius in cement mortar (1:4) all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching etc complete all as specified and directed.
M&L for PCC 1:2:4 type B 0 using 12.5 mm graded stone aggregate as in coping etc complete all as specified and directed.
Removing excavated material (soil) to a distance n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for 15 mm thick cement plaster in cement mortar (1:4) on fair faces of brick work or concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L providing precast cover slab RCC 1:2:4 (20 mm graded stone aggregate) type B-1 for manhole/ drain/chamber cover set in cement mortar 1:6 complete all as specified and as directed .
M&L mild steel TMT bar 10 mm dia and over cut to length bend to shape spirally for hooking for column and hooking ends and binding with mild steel wire not less than 0.9mm dia complete all as specified and directed.
E/M WORKS Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
M&L for point wiring concealed type with 1.50 sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and Including rigid PVC conduit medium class concealed on wall and with stove enameled steel heavy class conduit on RCC roof ceiling or structural steel or wooden truse surface type fixed with sadlles screwes as per Engineering practices of suitable size but not less than 20 mm dia with its accessories, sunken type pressed steel terminal box made of 1.2 mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-142 here in before but for one socket outlet 5/6 Amps on independent bd controlled by one switch complete all as specified & directed.
All as per item No-142 here in before but for one socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed.
All as per item No-142 here in before but for one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way switch on independent board but below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-142 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 142 to 146 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (iv) Minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed.
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed.
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed.
M&L for point wiring concealed type with 1.50 sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and Including rigid PVC conduit medium class concealed on wall and with stove enameled steel heavy class conduit on RCC roof ceiling or structural steel or wooden truse surface type fixed with sadlles screwes as per Engineering practices of suitable size but not less than 20 mm dia with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-151 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the same board with other switches complete all as specified & directed.
All as per item No-151 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-151 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the Ind board with other switches complete all as specified & directed.
All as per item No-151 here in before but point wiring for one six pin socket outlet 15 & 5 amps (independent) controlled by one modular switch using PVC FRLS cable of size 2.5 sqmm complete all as specified & directed. NOTE-For item no 151 to 155 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (iv)Minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fixing modular metal GI flush box 1/2 module as per site requirement suitable for 20mm dia conduit with and fixed on walls in CM 1:4 and making good the disturbed surfaces of walls as per existing complete all as specified and directed.
All as per item No-156 here in before but modular metal flush box of 3 module
All as per item No-156 here in before but modular metal flush box of 4 module complete all as specified and directed.
All as per item No-156 here in before but modular metal flush box of 5 module
All as per item No-156 here in before but modular metal flush box of 6 module complete all as specified and directed.
All as per item No-156 here in before but modular metal flush box of 12 module complete all as specified and directed.
All as per item No-156 here in before but modular metal flush box of 18 module
Supply and fix modular white cover plate with frame 1 module for mounting modular switches,sockets and regulators etc. complete all as specified and directed. .
All as per item No-163 here in before but modular white cover plate with frame 2 module complete all as specified and directed.
All as per item No-163 here in before but modular white cover plate with frame 3 module complete all as specified and directed.
All as per item No-163 here in before but modular white cover plate with frame 4/5 module complete all as specified and directed.
All as per item No-163 here in before but modular white cover plate with frame 6 module
All as per item No-163 here in before but modular white cover plate with frame 2x 6 module
All as per item No-163 here in before but modular white cover plate with frame 3x 6 module
Supply and fix switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
Supply and fix bell push modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
Supply and fix socket outlet, 6 Amps, modular type, 2 module 230 volts complete all as specified and directed.
Supply and fix switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed. Make: Anchor Cat No.21066 or equivalent as approved by GE.
Supply and fix socket outlet, 6/16 Amps, modular type, 2 module 230 volts complete all as specified and directed.
Supply & fix rotory stepped type electronic fan regulator modular type,Single module 120 watt 230 Volts complete all as specified & directed.
S&F for ceiling rose surface bakelite 50 x 25 mm size 3 terminals complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed.
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed.
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed.
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed.
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed.
S&F in replacement LED Batten surface/wall mounted with specially designed powder coated aluminium housing,high optically efficient polycarbonate diffuser,in built electronic driver duly wired up to terminal block,power consumption<22W,luminaire lumen >2000 lm,system efficiency of >120 lumens/W,LED make Nichia/Cree/Everlite/Eclison/Osram/lumiled,with LED binning as per ANSI Bin C78.377A,photo biological safety report as per IEC 624718& electrical insulation class 1 Ingress protection IP 20,clor rendering index CRI> 80 ,temp range 0 to 450 C ,driver efficiency >85% Power factor >0.9 THD <20% as per IEC 61000-3-2 ,color temp -6500K,Surge protection 2.5 KV,50000 burning hrs (min) as per L7O criteria,two stages isolated constant current operated driver with range 150-270 V AC and safety extra low voltage safe level< 60 V DC as per IEC standard with LM70 & LM 80 certification complete all as specified and directed.
S&F for 2 ft x 2 ft recess mounted full panel LED luminaire with white powder coted housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired upto terminal block, power consumption< 35 W, luminaire lumen > 3500lm and system efficiency > 120lm/w, CRI> 80, LED Make :- Nichia/Cree/Osram/Lumined with LED binning as per ANSI Bin C78.377A, Photo biological safety report as per IEC624718 & electrical insulation class 1 , colour temp- 5700k, Ingress protection IP20, Driver efficiency > 85% , 50000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor > 0.95 THD <10%, surge protectionin CM-3KV, two stage isolated constant current operated driver with range 150-270V AC and safety extraa low voltage safe level < 60V DC as per IEC standard, with LM79 & LM80 certification complete all as specified and directed.
S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresneldiffuser with silicon gaskets for IP-65 protection, power consumption < 35 W and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, CRI > 70, ambient temprature range 0-450c, THD<10%, colour tempreature 5700K, surge protectionin cm 3.5KV 50000burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low volatge safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall complete all as specified and directed.
S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 15 Watt LED warm white in colour with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 complete complete all as specified and directed.
S & F in replacement LED light fitting 1x9 W/1X10 W bulkhead luminaires including LED light driver holderconnecting up with three core flexible copper conductor cable, power consumption < 10 W and system efficiency > 100lm /W, of suitable size complete all as specified & directed.
Supply and fixing in replacement round shape 12/15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
Supply and fixing midbay LED light fittings of capacity 65 Watts, powder coated aluminum heat sink for efficent heat dissipation and high purity anodized refelector with electro chemically anodised matt finish inside, the effective glass optics for maximum illumination radious of aluminium reflector not less than 240 mm dia of outer peripherals. Driver and accessories prewired power consumption less then 65 W, with luminaire lumen >8000 lm, colour temprature not less than 6600k, ingress protection IP-65 with luminous efficancy of 130 lm/Watts including PVC insulated three core 0.75 sqmm copper cable and includinding suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed.
Supply & fix NEW GENERATION POST TOP energy saving envirmental friendly long life 35 watt LED luminaire light fitting, IP 65 protection with reflector cover electronic driver, connector block etc with internally prewired fixed to brcket on gate with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified and directed.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with four runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC conduit medium grade of suitable size but not less than 25mm dia with its accessories, concealed type, including two run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes :- Finished sub main wiring with four runs of 10.0 sqmm cable & two run of 10.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified and directed .
Supply and fix MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 200 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete as per IEC 61439-3 without MCB but with enclosue blank plate complete all as specified and directed .
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 200 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed .
Supply and fix MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB complete all as specified and directed.
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed.
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed.
Supply and fixing in replacement miniature circuit breaker (MCB) TPN 40 Amp, 4 poles, 415V 10KA 'B' curve current carrying capacity in the DB IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning., complete all as specified & directed.
Supply and fixing in replacement miniature circuit breaker (MCB) TPN 25 Amp, 4 poles, 415V 10KA 'B' curve current carrying capacity in the DB IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning., complete all as specified & directed.
Supply and fixing in replacement MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply & fix in replacement MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for light circuit)
Supply & fix in replacement MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for equipment & power circuit)
M & L earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm size, buried directly in ground (earth pit not less than 2.25 Metre deep below normal ground level) with top edge of the plate not less than 1.5 Metre below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Metre above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 metre away from starting point, all as per electrical plate no:3 of SSR part-1 complete all as specified and directed.
Supply & fix Exhaust Chimney 90 cm width (3-5 burner stove for wall mounted chimneys) with suction capacity of 1500 m3/hr, auto clean, stainless steel baffle filters, remote control, energy efficient LED Lamps, island mounted, metal blower connected with ducting system, 220 W capacity connected to stainless steel duct pipe of approx length 5 RM fix on wall (For kitchen size more than 200 sqft and heavy frying/grilling) | Filter Surface Area: 38 x 30 cmsq. Control Type: Touch and Gesture | Max noise(dB): 58 | Lamp - LED 2 x1.5 watt, for smooth functioning complete all as specified and directed.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed.
S&F iron metal body heavy duty exhaust fan 300 mm sweep, double ball bearing, copper wound, with louvers, 230 volts, 50 Hz, including connecting from ceiling rose to fan connector complete all as specified and directed.
S&F cast aluminium housing body heavy duty exhaust fan 450 mm sweep, double ball bearing, copper wound with louvers, 230 volts, 50 Hz, including connecting from ceiling rose to fan connector complete all as specified and directed.
Supply and fix electric water heater, of capacity 25 Litres vertical storage type, outer body of the heater is made with tough ABS material with special inner tank coating that prevents corrosion and rusting and results in a long tank life energy-efficient and Heating Element upto 2 KW (copper tube)-Spiral Type Multiple safety systems for protection against dry heating, overheating and overpressure, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece (hot & cold of length uoto 450 mm long with to be fixed on wall with fastener mild steel 100 mm long x 10 mm dia with expension type split pin and bolts complete for hanging of geyser all as specified and directed
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and writing of MES/identification No. of fans and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as specified and directed.
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and directed.
Supply & Laying,testing ,cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 50 Sqmm 3.5 core compele all as specified and directed.
Supply & Laying,testing ,cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 25 Sqmm 4 core compele all as specified and directed.
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and directed .
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed .
Removal of excavated material n.exc 50 metre away and depositing where directed at a level n.exc 1.5 metre above from starting point complete all as specified and directed .
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and directed.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as specified and directed.
Supply and fixing GI Pipe 40 mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and directed.
Supply and fixing GI Pipe 50mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and directed .
B/R WORKS Taking down cement plaster in any cement mortar on stone wall including deep (minimum 15 mm from brick surface) racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L applying two coats of water proofing coating with authorized applicators on brick or concrete surfaces complete all as specified and directed (Make of water proofing coating Smart care damp block 2K of Asian paints or Equivalent) complete all as specified and directed.
M&L for rendering (internal plaster) 10 mm thick cement and coarse sand 1:4 with guiniting machine pressure capacity not less than 5 Kg per Sqcm on fair face of brickwork or concrete surfaces upto window cill complete all as specified and directed.
M&L for rendering (external plaster)10 mm thick cement and coarse sand 1:3 with guiniting machine pressure capacity not less than 5 Kg per Sqcm on surface other than fair face of brick work or concrete surfaces upto window cill complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 with water proofing compound @2%by weight of cement or as per manufacturer's instructions on fair face of brickwork or concrete surfaces.Note:- WPC shall be measured & paid separately under respective items complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
M&L for rubbing and mirror polishing of existing kota stone flooring and skirting complete all as specified and directed.
S&F welded steel wire fabric weight not exc 4 Kg per Sqm as in extra reinforcement to RCC members including all cutting, bending and binding complete all as specified and directed .
M&L 5 cm thick sand stone slabs in sun-shades chajjas,shelves ,cills,landings,coverstones,templatesetcn.exc 2 m in length,punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4 complete all as specified and directed.
S&F joist,channel,angle or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20 mm of the length indicated ) Fe-410-w(Gde-E-250) quality -B complete all as specified and directed.
Dismantling boarding, any description, fix in any position with nails complete all as specified and directed.
S&F in repairs ,PVC kitchen frame of section 18x75 mm made out of 18 mm thick PVC ply sheet of pleasing colours, print and prelam finishes one side as approved and frame shall be fixed with & including plastic fasteners and 50 mm long steel screws inside by using drilling complete all as specified and directed.
S&F in repairs ,PVC kitchen shutters made out of 18 mm thick PVC ply sheet of pleasing colours, print and prelam finishes one side as approved and kitchen shutters shall be fixed to the PVC kitchen frame & including auto hinges ,steel screws and modular handles complete all as specified and directed.
S&F in repairs drapery rod 25 mm dia ,high strength stainless steel ‘304’ grade curtain rod with decorative stainless steel ornamental attachment (side knob) at both ends and one set of ornamental decorative stainless steel clamps (bracket) and matching curtain rings minimum 8 Nos in one running meter complete all as specified and directed.
S&F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and directed.
M&L preparation of old treated surfaces of any description, over 10cm in width or girth and applying finish coat with synthetic varnish complete all as specified and directed.
M&L 100 mm thick plain cement concrete 1:2:4 type B1(using 20 mm graded stone aggregates) as in flooring finished even and fair complete all as specified and directed.
M&L 20 mm thick wear proof topping (incorporating an approved metallic floor hardener), laid on green concrete floors and pavings, and finished even and smooth (except metallic hardener) complete all as specified and directed.
Supply only Mettalic floor hardener complete all as specified and directed.
S&F 4.0 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
E/M WORKS M&L for point wiring concealed / surface type with 1.50 sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and Including rigid PVC conduit medium grade of size not less then 20 mm bore with its accessories, concealed point wiring shall be carried out in wall portion and with stove enameled steel conduit heavy grade of size not less than 20 mm bore with its accessories for the point wiring portion on steel trusses, surface type fixed with seddles/ clamps, screws etc in the 10 mtrs height’s hanger trusses, pressed steel/ anodised steel termination box of suitable size made out of 1.2 mm thick M S sheet duly printed with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches, sockets, fan regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long with aluminium base plate to be fixed on hut type roof on wooden/ PVC block of suitable size 25 mm thick fixed with screws and nails on hut type roof of blgd complete all as directed at site.
M&L for Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground shell be fixed on heavy duty PVC/ porcelain insulators with help of screws plug and gutty etc complete all as specified and directed.
M&L for Galvanised iron strip 25 x 4 mm buried in ground with 40 mm GI light grade protection pipe fixed on wall with screws, plug & gutties and PVC/ porcelain insulators for upper/down conductor all as directed at site. Note:- Item shell be excuted if required at site beyond 7.5 M main earthing lead complete all as specified and directed.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised iron strip of size 32x6mm as earth lead by means , including 40 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no-3 of SSR part-1 complete all as specified and directed.
M&L for test point terminal block made of gun metal or phosphouus bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal screws complete all as specified and directed.
Supply and fix PVC body fresh air circulator of size 200 mm sweep, with PVC louvers, operated at 230 Volts 50 Hz, 1350 to 1400 RPM with 3 core flexible copper conductor cable cord of size 0.75 Sqmm from fan to ceiling rose complete all as specified and directed.
JEE JEE BUILDERS
M/S J J ENTERPRISES
TEAM ACC INFRABUILD PRIVATE LIMITED
R.C. Magla and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .