Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹5.4 L+₹1.1 L (24.3%)Rejected-Finance 02 JAMEEWAR COMPLEX RING ROAD HANUMAN NAGAR GONDIA MAHARASHTRA 441614 | GONDIA | MAHARASHTRA | 441614 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L.3₹5.6 LRejected-Finance VILLAGE MATPUR POST OFFICE MANAURI ALLAHABAD 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L.3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹5.6 L+₹1.3 L (28.8%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹6.3 L+₹1.9 L (44.3%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
21 Mar 2020, 6:00 pmClosed
AGE (I) Manauri Allahabad
AGE (I) Manauri Allahabad-212212
REPAIR/ MAINTENANCE TO COMPOUND WALL, FENCING IN OFFICERS ENCLAVE AT 24ED AF STN MANAURI
2020_MES_327060_1
8748/E8
Open Tender
Civil Works
Item Rate
182 days
Manauri, Allahabad
As per tender documents
6 documents required · 6 mandatory
₹500
AGE (I) AF Manauri
₹18,000
Yes
27 May 2020
20 Feb 2020
23 Mar 2020
20 Feb 2020
21 Mar 2020
6 Mar 2020
Amount
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete as specified & directed by Engineer-in-Charge.
M&L for PCC1:3:6 type C-2 using 40mm graded stone aggregate , as in foundation,filling & mass concrete etc complete all as specified and directed by Engr-in-charge.
M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified and directed by Engr-in-charge.
S&F mild steel angle iron 50x50x6mm thick as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming Fe-290 Gde E-165 complete as specified & directed by Engineer-in-Charge.
M&L mild steel round bar 10 mm dia and over cut to length, bend to shape required, including cranking, bending, spirally for hooping for columns, hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified and directed by the Engineer-in-Charge
S & F mild steel round bar 6 to 8mm dia etc cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with complete all as specified and as directed.
M & L Mild steel screw bolts (diameter of neck 11 to 15mm) (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
M & L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
M & L applying two coats of synthetic enamel paint on new steel surfaces of any description n exc 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
S & F in repair chain link fencing MS galvanised, 3.14mm dia, 75x75mm mesh fixed to RCC post including securing or tying with GI MS wire, staples etc.complete all as specified and directed. Note :- Angle iron post, fillet and bolts for fixing chain link shall be measured and paid for separately under repective item of this schedule.
S&F rolled mild steel framed work as in doors or gates of angle or other section conforming to Fe-410-W (E-250) quality-B with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S & F 1.60mm thick mild steel plain, black sheet in chullah hood, covering to door shutters, ducts etc, cut to size, hole punched including fixing to M S Clamps with necessary bolts and nuts complete all as specified and directed.
S&F in repair galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainingbolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)etc complete all as specified and as directed.
M & L for preparation of new plastered surfaces on walls and applying two coats of cement base paint complete as specified & directed by Engineer-in-Charge.
Demolition of Brick works, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed
M & L brick work with sub class 'B' old size brick, designation 75, straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for brick work with subclass “B” [Except bricks] Old size bricks, straight or curved on plan exceeding 6 m mean radius built in cement sand mortar in 1:6 complete all as specified & directed. Note: Old Bricks shall be used obtained from serial Item No. 14 above.
M & L for rendering 15 mm thick on fair faces of brick walls or concrete surfaces in CM 1:4 finished even and smooth without using extra cementcomplete as specified & directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone surface of wall built in cement sand mortar including racking out joints, hacking for key, scrubbing down with water etc
Demolition of Cement Concrete [Un-reinforced] in ground floors & paving not exceeding 15 cm thickness [below or above ground level] complete all as specified & directed. .
Dismantling of stone slab & tiles of any desciption and any thickness in floors, laid, bedded and pointed in any mortar complete all as specifed and directed.
M&L for machine pressed precast concrete interlocking paver block with heavy duty designer pattern coloured any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade laid over 25mm thick sand cushioning including filling of joints with sand complete. Note :- (i) Quoted rate shall deem to be included cost of 25mm thick sand cushioned below paver and during compaction. (ii) Design and colour of paver block shall be as approved by AGE(I).
M & L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection complete all as specified & directed by Engineer-in-Charge.
M & L 75 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor or path, finished surface even & smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C-1, (using 20mm graded crushed stone aggregate) as in surface channels and drains all as specified. Note :- Forming channels shall be measured and paid for separately under respective item of this schedule.
M&L for extra for forming fair finished drain on channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc (Inner girth only to be measured for payment).
Add or deduct from Srl item No 26 above for each 25 mm girth or part there of over or under 30 cm. Note :- This item is only for adjustment of rates.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.
M/S R S Traders
m/s neeraj kumar shukla
M/S ANKIT ENTERPRISES
singrourenterprises
M/S Garg Sons
oasis contractor builder and supplier
HIMANSHU TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .