Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 67D EXECUTIVE PO IZZAT NAGAR SUNCITY VISTAR BAREILLY UTTAR PRADESH 243122 | BAREILLY | UTTAR PRADESH | 243122 | Admitted-Finance |
| 2 | Admitted-Finance 269 ATTOR NANGLA 2 FIROJPUR MOHANPUR SIHANI GATE GHAZIABAD GHAZIABAD UTTAR PRADESH 201206 | GHAZIABAD | UTTAR PRADESH | 201206 | Admitted-Finance |
| 3 | Admitted-Finance C 175 AWAS VIKAS COLONY SITAPUR SITAPUR SITAPUR UTTAR PRADESH 261001 | SITAPUR | UTTAR PRADESH | 261001 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical UWD | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
30 Jun 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC Shahjahanpur
Electy Trans Circle Shahjahanpur
Annual Patrolling and Maintenance work of 220KV and 132KV lines under ETSD-I Sitapur
2022_UPTCL_707182_1
12 ETC(S)/2022-23
Open Tender
Electrical Works
Fixed-rate
365 days
Sitapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹16,000
14 Jul 2022
10 Jun 2022
30 Jun 2022
10 Jun 2022
30 Jun 2022
10 Jun 2022
10 Jun 2022 - 29 Jun 2022
120 days
Amount
Quarterly tower to tower ground patrolling of following 220 & 132KV Transmission line alongwith ground work i.e. identification of missing tower parts, nuts & bolts, faulty disc insulator/Polymer insulator, damaged conductor tower earthing, tower accessories, tree and branches existing/infringing in the corridore and other dangerous aspects viz. Damage to E/W, Conductor, jumper, insulator, damage to foundation, coping, chimney etc. observed in line. The report must be submitted in Division in prescribed proforma after each patrolling. All labour T&P vehicle etc. is to be arranged by contractor at his own cost. (4 Times in a Year)
220KV Sitapur-Shahajahanpur Transmission line (94X4=376 Km.)
132KV Sitapur-Neri Line (40X4=160 Km.)
132KV Neri-Shahajahanpur Line (53X4=212 Km.)
132KV Sitapur-Ramnagar Sugar Mill Line (17X4=68 Km.)
LILO of 132KV Sitapur-Neri @ Mishrikh (26x4=104Km.)
Emergency patrolling of 132KV Lines on occurance of tripping/breakdown of line. Emergency patrolling includes checking of tower, conductor, earthwire, insulator, clamps, fittings etc. to locate the defects/fault/deficiency. Emergency patrolling is to be carried out with immediate effect after receiving intimation from concerned SDO/EE including submissiion of emergency patrolling report to Engineer/Incharge of the line. (2xRoute length)
Cleaning of 27/35 Meter corridore throughout the year by Lopping/Chopping of various species of trees branches and cutting of bamboo bushes falling under the corridore with all due care of safety and precaution to avoid any damage to near by building Crop & Power telephone lines passing near vicinity of the trees of 220 & 132KV Transmisson line along with throwing of cut branches at least 50 Meter away from the line corridor.
Fixing of tower members, nuts bolts etc. as directed by SDO/JE concerned, Punching of bolts by champhering, fabrication, cartage etc. including Opening/cutting of Nuts-bolts of remaining cut pieces of tower member theft by miscreants to be opened/cut safely with the help of Gas cutter/Hackshaw blade, including all required labour, T&P Vehicle etc. required for completion above work. (As per requirement)
Attending breakdown due to failure of Disc/Polymer Insulator and replacement of Tension string alongwith mobilization of skilled gang including carriage of material from store to site and site to store for complete of work.
Attending breakdown due to failure of Disc/Polymer Insulator and replacement of Suspension string alongwith mobilization of skilled gang including carriage of material from store to site and site to store for complete of work.
Cleaning of Porcelain Insulator (Only in Polluted Area) Ones in year (In Oct. to Nov.)
Dismantaling opening of earthwire of one span of size 7/10, 7/9 SWG including E/W accessories etc. towering earthwire between location with suspension clamps, copper bonds clipping etc. Rerolling of dismantled earthwire drum and shifting from to designated store.
Laying, tensioning, stringing, clamping, jointing etc of earthwire fitting of all E/W accessories, etc. including shifting earthwire from store to site.
Attending breakdown of 220KV Line conductor such as broken conductor cutting of stands or snapping of conductor following works are to be carried out:-
Dismantaling opening of ACSR Zebra Conductor of one span and acessories alongwith disc insulator strings, lowering down of conductor and accessories from tower location including cliping of conductor and rerolling of dismantling conductor including carriage to store. .
Laying, tension string clamping jointing etc as per requirement of ACSR Zebra Conductor of one span including hoisting of insulator strings armour rod vibration jumper etc and all associated work for job completion including carriage to store.
Attending breakdown of 132KV Line conductor such as broken conductor cutting of stands or snapping of conductor following works are to be carried out:-
Dismantaling opening of ACSR Panther Conductor of one span and acessories alongwith disc insulator strings, lowering down of conductor and accessories from tower location including cliping of conductor and rerolling of dismantling conductor including carriage to store. .
Laying, tension string clamping jointing etc as per requirement of ACSR Panther Conductor of one span including hoisting of insulator strings armour rod vibration jumper etc and all associated work for job completion including carriage to store.
Thermal Scanning of line by high resolution infra red camera minimum Resolution 240x320 using telephoto lences of 7-14 deg. (Min Distance 150 Meter) of all section tower jumpers including all midspan joints during on load conditions under ETD, Sitapur and providing coloured print of report in two sets (One in Year before summer)
Cheacking & Tightening of jumpers, replacement of deteriorated jumpers (One in a year after thermal Scanning.)
JBS ELECTRICALS
EMC Associates
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .