Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.5 LAccepted-AOC | 1 | Accepted-AOC Accepted | |
| 2 | 2₹12.0 L+₹42,276.60 (3.64%)Rejected-AOC | 2 | Rejected-AOC Rejected | |
| 3 | 3₹12.1 L+₹49,065.60 (4.23%)Rejected-AOC | 3 | Rejected-AOC Rejected | |
| 4 | 4₹12.1 L+₹54,363.10 (4.69%)Rejected-AOC | 4 | Rejected-AOC Rejected | |
| 5 | 5₹1.3 L−₹10.3 L (88.7%)Rejected-AOC | 5 | Rejected-AOC Rejected |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
7 Nov 2019, 6:00 pmClosed
Garrison Engineer Basoli
Garrison Engineer Basoli Pin-184152
SPECIAL REPAIR TO BLDG NO T-19 AND T-22 AND PROVN OF CERTAIN REVENUE AND MINOR WORK OF E/M NATURE AT BASOLI UNDER GE BASOLI
2019_MES_290243_1
GE/BAS-44/2019-20
Open Tender
Civil Works
Item Rate
90 days
GE Basoli
As Per Tender documents
8 documents required · 8 mandatory
₹500
GE Basoli
₹22,000
Garrison Engineer Basoli
20 Feb 2020
17 Oct 2019
9 Nov 2019
17 Oct 2019
7 Nov 2019
31 Oct 2019
24 Oct 2019
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and directed...
M&L PCC 1:3:6 type C-2 ( Using 40mm graded crushed stone aggregate ) in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and directed .
Supply and fix for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding/Eaves board to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws . complete all as specified and directed.
Providing, cement concrete Type C-1 1:3:6 (20 mm graded aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, as directing complete all as specified and directed .
Rendering 15mm thick on brick work or concrete surfaces as in wall in cement mortar 1:4 finished surface even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft / loose soil. complete all as specified and directed.
Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L Glazed ceramic tiles in vertical surface 350x250x7mm/450x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including Screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying tiles complete all as specified and directed.
M&L for providing 75mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Material and labour for Steel window factory made double shutter and tubular moulded frame of 16 gauge suitable for double shutter as per drg No CEPZ/TD/245/01 sheet 1/1 and CEPZ/TD/246/01 sheet 1/2 (double for mosquito proof one glazed with glazing bars and one gauged without glazing bars ) with side hung shutters including projecting type hinges non friction with 3mm thick 100mm long handle and two Nos tower bolts 100mm long welded on 3.0mm thick MS plate to each window shutter and including hold fast and painting with one shop coat of zinc chrome primer complete all as specified and directed.
M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 125 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for providing cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) for filling in the pressed steel door frame/hold fast complete all as specified and directed..
Taking down chowkats or frames with shutters (w/o taking off shutters from the frame) exc. 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed .
M&L for factory made, 2nd class hard wood rail and style 35 mm thick, plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered partical board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply and fix medium density PVC board 20 to 22mm thick prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber/angle iron frame work etc complete all as specified and directed..
Supply and fixing for 35 mm thick Factory made 2nd class hard wood door Glazed and skeleton open rebated and prepared to receive glass, gauze, etc.divided in square with out sash bars The sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed..
S&FGalvanised MS wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm, complete all as specified and directed..
S&F Extruded aluminium alloy handles fabricated type anodised and fixed, 150 mm size complete, all as specified and directed.
S&F MS 300mm ordinary rat tail rod pattern springs including roller and roller plate. complete all as specified and directed..
Supply and fix for Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt,complete all as specified and directed.
Supply and fix for Aluminium alloy, anodised, sliding door bolt 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed,complete all as specified and directed.
M&L for preparation of wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preperation of old surface of wall and applying one coat of dry distemper , complete all as specified and directed.
M&L for preperation of new plastered surface of wall and applying two coat of dry distempercomplete all as specified and directed.
M&L for preperation of old surface of wall and applying one coat of cement base paint complete all as specified and directed.
M&L for preperation of new plastered surface of wall and applying two coat of cement base paint over a coat of primer, complete all as specified and directed.
Supply and fix 15 mm dia bore Bib taps , cast copper alloy, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed complete all as specified. complete all as specified and directed.
Supply and fix for 15mm dia bore Stop valve/cock, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed
Supply and fix for steel water tubing galvanised, 15mm bore, medium grade with all fittings and fixed to walls, including cutting chases in walls etc complete all as specified and directed.
Supply and fix for steel water tubing galvenised, 25 mm bore, medium grade with all fittings and fixed to walls, including cutting chases in walls etccomplete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe of 20mm bore complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm.complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified and directed.
Taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed
S&F 10 mm thick PVC insulation panel with EPS stuck to 1 mm plain PVC sheet suitably placed in false ceiling grid made of aluminium/GI/MS as per specification and drawing complete with 6 mm dia GI hanging chanel including necessary fixtures,drilling, fasteners etc complete all as specified and directed by Engr - in - Charge.
S&F Harrison curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc all as specified and directed
M&L Roof trusses (framed), trussed, purlins, crane gantries, rail and heavy brackets framing (Beams, tee, angle, channel or flat section) including distance pieces incl a shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication all as specified and directed
M&L Mild steel bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed the both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 10cm and n.exc 15cm long dia of neck exc 11mm to 15mmall as specified and directed
M&L Mild steel bolts (purpose made) with hexagonal or square head at one end and screwed the other or screwed the both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 30cm long dia of neck exc 12mm to 20mm all as specified and directed
M&L for Mild steel as in framed work such as in grills, gratings etc. with ends of bar shouldered and/ or rivetted or forged into spikes, framed iron doors, ladders, framed balusters, walk ways, railings, frame work of water tank and similer work confirming to Fe-290, Gde- E-165 complete all as specified and directed
Dismantling of asbestos cement (corrugated, semi-corrugated, etc.) sheet in roof covering all as specified and directed
Dismantiling wall and ceiling board (fibre, pulp, imnsulation etc) or insulation boards/slabs/blankets any thickness including cover fillets all as specified and directed
Dismantling timber scantling in fillets, rails, posts rafters purlins under 40Sqcm in section all as specified and directed
Dismantling wrough iron or mild steel work of any descrfiption not otherwise provided for all as specified and directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Material and labour for Point wiring with 1.5 Sqmm (nominal area)copper conductor FRLS cable (Multi stranded) PVC insulated and unsheathed in and including concealed PVC rigid non metallic conduit (ISI marked) with sunk cast iron/pressed steel terminal boxes of suitable size with 3mm thick plastic laminated sheet for light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed with colour code earth wire connected to common earth dolly complete all as specified. Note : (a) Unit rate include for cutting chases for conduit and sinking for boxes and making good to wall, floors etc. The metal flush box and cover plate shall be measured & paid under relevant items of BOQ'
All as per item No 161 but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per item No 161 but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Material and labour for Point wiring with 2.5 Sqmm copper conductor FRLS cable (Multi stranded ) PVC insulated and unsheathed cable conductor in and including concealed PVC rigid non metalic concealed conduit (ISI marked) of suitable size with sunk cast iron/pressed steel terminal boxes of suitable size with 3mm thick plastic laminated sheet for one 3 pin socket outlet 15 amps on independent board incl continuous 1.5 sqmm copper conductor FRLS (multistranded) PVC insulated and unsheathed cable earth wire connected to common earth dolly complete all as specified. Note : Unit rate for cutting chases for conduit and sinking of boxes and making good to wall,floor ceiling complete all as specified and directed by Engineer in charge. The metal flush box and cover plate shall be measured & paid under relevant items of BOQ'
Supply and fix for Switch piano, flush type single pole, one way 5 Amp, complete all as specified and directed.
Supply and fix for Switch piano, flush type single pole, one way 15 Amp, complete all as specified and directed.
Supply and fix for Socket outlet 2 in 1, 5 pin, 5A complete all as specified and directed.
Supply and fix for Socket outlet 2 in 1, 6 pin, 5A and 15 Amp multipurpose complete all as specified and directed.
Supply and fix for switch socket combination multipurpose 2 in 1 , 3 pin 5 and 15 Amp flush type universal complete all as specified and directed.
Supply and fix for switch socket combination multipurpose 2 in 1 , 3 pin 5 Amp flush type universal complete all as specified and directed.
Supply and fix ceiling rose surface bakelite, two to three terminal isolated body fixed on PVC round block complete all as per specified and directed.
M&L for Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings complete all as per specified and directed.
Supply and fix for stepped type electronic fan regulator flush type with 5 steps speed control complete all as specified and directed.
Supply and fix in replacement LED tube light fitting 1 x 16 watt, 230v including tube rod with polycarbonate diffuser , of 4 feet ,complete with all accessories and pre-wired incl all necessary electric connection with three core copper cable 23/0.0076 complete all as specified and directed.
Supply and fix for sheet metal powder enclosure powder coated versatile double door SPN 12 way distribution board for MCB provisions fitted with copper bus bar rated, neutral link , earth bar and din rail suitable for use on 240/215Volt, 50Hz complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage cap 80 Ltrs and nominal cooling capacity 40 Ltrs complete all as specified and directed. Make : Blue star/Voltas/ Shri Ram
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated. Make : Voltas/Hitachi/ O-General.
Supply installation, testing and commissioning of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % having display to input and output voltage of cap 3 KVA complete all as specified and directed.
Supply installation, testing and commissioning of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % having display to input and output voltage of cap 4 KVA complete all as specified and directed.
Material and labour for sub main wiring with two run of single core FRLS PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 2.50 Sqmm drawing into and including medium grade PVC non metallic rigid conduit of 20 mm dia and making electric connections including one run FRLS PVC insulated single core copper conductor cable 2.50 Sqmm as a earth continuity conductor(green colour), including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 2.50 sqmm single core FRLS PVC insulated copper conductor cable one run of 2.50 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
Material and labour for sub main wiring with two run of single core FRLS PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.00 Sqmm drawing into and including medium grade PVC non metallic rigid conduit of 20 mm dia and making electric connections including one run FRLS PVC insulated single core copper conductor cable 4.00 Sqmm as a earth continuity conductor(green colour), including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4.00 sqmm single core FRLS PVC insulated copper conductor cable one run of 4.00 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
Material and labour for sub main wiring with two run of single core FRLS PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 6.00 Sqmm drawing into and including medium grade PVC non metallic rigid conduit of 20 mm dia and making electric connections including one run FRLS PVC insulated single core copper conductor cable 6.00 Sqmm as a earth continuity conductor(green colour), including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 6.00 sqmm single core FRLS PVC insulated copper conductor cable one run of 6.00 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
Supply and fix in repair for MCB SP 5 to 32 Amps with 10 KA breaking capacity complete all as per specified and directed.
Supply and fix in repair for MCB SPN 63 amps with 10KA breaking capacity complete all as per specified and directed.
Supply and fix MCB DB SPN 02 way suitable for 230volt AC complete all as per specified and directed.
Supply and fix MCB SPN 25 amps with 10KA breaking capacity complete all as per specified and directed.
Supply and fix exhaust fan 300 mm sweep with louver complete including making all arrangement for holes in brick / stone massonery wall of any thickness grouting of nuts / bolts in wall complete all as specified and directed
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,25 Sq mm X 2.0 core cross section area including takingout existing cable complete all as specified and directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,16 Sq mm X 2.0 core cross section area including takingout existing cable complete all as specified and directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,10 Sq mm X 2.0 core cross section area including takingout existing cable complete all as specified and directed.
Material and labour for Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed.
Material and labour for sand cushioning to under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable as specified in SSR 1991 of part -I complete all as specified and directed.
Supply and fix in repair for GI light grade tube of size 40 mm dia for laid in trenches/ wall/ceiling/floor for protection of cable/earthing strip complete all as specificifide and directed.
S&F double corrugated high densiy polyhelene pipes having outer dia 63/50mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fiings as required at site including taking down the old unserviceable complete all as specified and directed. Make: Gamson India/Dustron/Rex Polyextrusion Ltd/SRIF/SKF.
S&F structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, complete all as specified and directed.
Supply, Installation, commissioning and testing of High Intensity type LED based flood light of 120 watts rating , enclosed in high grade aluminium pressure die-cast housing with heat resistant toughened flat glass suitably gasketed, Ingress protection IP- 65, Nominal voltage 90 V - 270 V, 50 HZ, AC heat management compliance with and including high power LEDs luminous eficiency not less than 100 lumen/Watt. Lumens , inbuilt micro controller power supply, easily adjustable for different mounting pipes, separate electronic driver cabin fully compliance to IS- 10322, dust and water proof cabinet, Effeciency of driver electronic not less than 85 % , power factor of complete fitting not less than 0.90, Lamp life not less than 50000 operating hours, Minimum view angle of the LED not less than 120 degree , colour Rendering index(CRI) not less than 80,CCT 5500K-6500K, Ratio of minimum and average illumination shall be minimum 0.3, Working Temperature-30 degree C to 60 degree C, Working Humidity 10% to 90% RH and connecting upto street light feeder/junction box cat part No PCGLFT1 01 120 57 of Polycab or equivalent make of philips,Bajaj, wipro and crompton, complete all as specified and directed.
Material and labour for Steel Tubular swaged pole complete with cast iron base plate , finial taper , bolts , nuts and screws etc as specified for type 410-SP-55-(11 mtr long) including painting with two coats of aluminium paint over one coat of aluminium red oxide primer,duly drilled hole 6nos at top portion of pole for fixing D clamp insulators and including all accessories complete all as specified and directed.
Supply and fix bus bar chamber box of size 300 mm X 200 mm X 150 mm deep fabricated out from mild steel sheet 2.00 mm thick, having locking arrangement and 2 nos aluminium bus bar strip of size 25 x 3 mm , mounted on insulators, one no MCB SP 20 Amps , 02 nos clamps made of mild steel flat of size 25 x 3 mm duly painted with two coat of aluminium paint over a coat of priming with aluminium red oxide and fixed with nuts and bolts of appropriate size to fix the box on pole complete all as specified and directed.
Supply and fix bus bar chamber box of size 200 mm X 150 mm X 150 mm deep fabricated out from mild steel sheet 2.00 mm thick, having locking arrangement and 2 nos aluminium bus bar strip of size 25 x 3 mm , mounted on insulators, one no MCB SPN 20 Amps , 02 nos clamps made of mild steel flat of size 32 x 6 mm duly painted with two coat of aluminium paint over a coat of priming with aluminium red oxide and fixed with nuts and bolts of appropriate size to fix the box on pole complete all as specified and directed.
Supply and fix service wire of size 6sqmm x 3 core with copper multistrand conductor 240 volt AC complete all as specificifide and directed.
Material and labour for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe with funnel with wire mesh at top, 15 mm bore light grade earth lead protection pipe upto main board with RCC cover suitable handle and angle iron frame for pit top and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. (Note: The rate quoted include the cost of earthing wire and protection upto 7.5 metre length.)
Supply and fix water heater storage type, (geyser) electric, 5 star bee rating with stainless steel inner tank single phase 230 vols, 50 HZ capacity 25 Ltrs including cutting/chasing of hole for fixing and making surface good as per existing complete as specified and directed.
Standard engineers
G.M. ENGINEERING SERVICES
AGGARWAL ASSOCIATES
Ashoka Engineers
M/S ONKAR SINGH PATHANIA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .