GEMC-511687706770357
Awarded to INNOVIOUS HEALTHCARE PRIVATE LIMITED
₹1.5 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BREATH CO ANALYZER | CO20 | - | 1 NOS | ₹1.5 L | 149,990 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.5 LQualified Make: INNOVIOUS
Model: CO20 INNOVIOUS HEALTHCARE PRIVATE LIMITED REGUS INFINITY BUSINESS HUBS 4TH FLOOR HALWASIYA COURT HAZRATGANJ LUCKNOW UTTAR PRADESH 226001 | LUCKNOW | UTTAR PRADESH | 226001 | Make: INNOVIOUS
Model: CO20 | ₹1.5 L | L1 | Qualified |
| 2 | Disqualified Make: FiT
Model: FiT 333I ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: FiT
Model: FiT 333I | - | - | Disqualified |
| 3 | Disqualified Make: Keyun
Model: KEYUN & PANTHER 1 BREATH ANALYZER ANTRIKSH TECHNOSYS PVT LTD E 173 LGF KALKAJI NEW DELHI 110019 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: Keyun
Model: KEYUN & PANTHER 1 BREATH ANALYZER | - | - | Disqualified |
| 4 | Disqualified Make: FiT
Model: FiT 333I 00 MARWARI COLONY BAHADURPUR ROAD NO 13 B RAJENDRA NAGAR PATNA BIHAR 800016 | PATNA | BIHAR | 800016 | Make: FiT
Model: FiT 333I | - | - | Disqualified |
| 5 | Disqualified Make: Keyun
Model: Eagle 3 + 545 KA 3 104 PARA ROAD RAJAJIPURAM LUCKNOW UTTAR PRADESH 226017 LUCKNOW LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | Make: Keyun
Model: Eagle 3 + | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
1 Sept 2018, 9:00 pmClosed
breath alcohol analyzers Breath Alcohol Analyzers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific)
Semiconducter Alcohol Sensor Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 400 0 to 400
0 to 500
0 to 600 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 1 Any applicable numeric value Easily replaceable mouthpiece with yes * 1/5 Sputum Trap Sample Taking Duration 5 * Analytical Response Time (At '0' level of Alcohol) 5 * Analytical Response Time for positive result 15 * Recovery Time at (1/2) mg/ltr 50 * Warm up Time (after putting on) 15 * Time required for re- calibration 6 * Barometric Pressure Range (hpa or millibar) 1000 * Shelf Life of Fuel Cell 3 * RoHS Compliant true * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements true * PHYSICAL Weight 0.167 * Size ( mm x mm x mm ) 120x70x30 * BATTERY OF ANALYZER Power Source Rechargeable Battery * Chemistry of Rechargeable Battery Ni-MH * Battery Voltage 9 * Battery Backup Time (continuous duty) 40 * Number of Spare Rechargeable Batteries supplied with the instrument 0 * Low Battery indication yes * DISPLAY/INDICATOR STORAGE/INTERFACE Display Type LCD * Display Size 3 * Availability of audible beeper for over range
low battery etc yes * Record Entry Through Integrated/Touch Through Integrated/Touch 2/5 Screen Screen
Through Alphanumeric KeyBoard Minimum Record Fields Full Information as per the user's requirement such as Driver Name
Vehicle number
inspector name
test report with time
date
geolocation
instrument id
etc * Record Memory (Minimum) 4000 4000
10000
20000
30000
50000 Record Data Downloadable to PC yes * Data Interface USB * GPS false * If yes
Capable to display the geolocation of test inspection location NA * Camera false true
false If yes
Capable to capture the clear image of test target NA * PRINTER Printer Without With
Without Type of Printer NA Portable Dot Matrix Printer with Wireless Bluetooth Connectivity
Portable Inkjet Printer with Wireless Bluetooth Connectivity
Portable Laserjet Printer with Wireless Bluetooth Connectivity
Internal Thermal Printer
NA Print Resolution (dpi) 200 * Printer consists of Inbuilt Rechargeable Battery
Paper for offence printouts
Charger NA * Minimum number of printouts that can be taken with the paper available with the Printer 1000 * "Minimum number of printouts that can be 100 * 3/5 taken with single charge of the printer battery (Hint:- Minimum 60 prints
if 'With Printer' May indicate '0' if not applicable)" Bis Registration number for Printer under CRS of MeitY IS 616:2010 R-41000027 * WARRANTY Warranty 1 1
2
3
4
5 (or higher) STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement
The instrument is hand held
portable and easy to operate true * If Yes
the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface
meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature 0 * Maximum Operating Temperature 50 * Relative Humidity Non Condensing (%) 95 * ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest true * Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest true * Conformity to Cold test at - 5/-10/- 15/-20 degree C (as true * 4/5 applicable) for 4 hours as per IS: 9000 latest Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification true * Test Report Number and Date GB11/84488 DATED 10/12/2015 * Name of the Lab and Address SGS
202B WORLEY PARKWAY
U.K. * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Buddhilal Prasad 233001
CMO District Hospital Gorabazar Ghazipur 1 15
538595
GEM/2018/B/76380
GeM Contract
breath alcohol analyzers
GeM Contract
15 days
Uttar Pradesh; Ghazipur
PRODUCT
Awarded to INNOVIOUS HEALTHCARE PRIVATE LIMITED
₹1.5 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BREATH CO ANALYZER | CO20 | - | 1 NOS | ₹1.5 L | 149,990 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| breath alcohol analyzers Breath Alcohol Analyzers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) | - | - | - |
| Semiconducter Alcohol Sensor Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 400 0 to 400 | - | - | - |
| 0 to 500 | - | - | - |
| 0 to 600 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 1 Any applicable numeric value Easily replaceable mouthpiece with yes * 1/5 Sputum Trap Sample Taking Duration 5 * Analytical Response Time (At '0' level of Alcohol) 5 * Analytical Response Time for positive result 15 * Recovery Time at (1/2) mg/ltr 50 * Warm up Time (after putting on) 15 * Time required for re- calibration 6 * Barometric Pressure Range (hpa or millibar) 1000 * Shelf Life of Fuel Cell 3 * RoHS Compliant true * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements true * PHYSICAL Weight 0.167 * Size ( mm x mm x mm ) 120x70x30 * BATTERY OF ANALYZER Power Source Rechargeable Battery * Chemistry of Rechargeable Battery Ni-MH * Battery Voltage 9 * Battery Backup Time (continuous duty) 40 * Number of Spare Rechargeable Batteries supplied with the instrument 0 * Low Battery indication yes * DISPLAY/INDICATOR STORAGE/INTERFACE Display Type LCD * Display Size 3 * Availability of audible beeper for over range | - | - | - |
| low battery etc yes * Record Entry Through Integrated/Touch Through Integrated/Touch 2/5 Screen Screen | - | - | - |
| Through Alphanumeric KeyBoard Minimum Record Fields Full Information as per the user's requirement such as Driver Name | - | - | - |
| Vehicle number | - | - | - |
| inspector name | - | - | - |
| test report with time | - | - | - |
| date | - | - | - |
| geolocation | - | - | - |
| instrument id | - | - | - |
| etc * Record Memory (Minimum) 4000 4000 | - | - | - |
| 10000 | - | - | - |
| 20000 | - | - | - |
| 30000 | - | - | - |
| 50000 Record Data Downloadable to PC yes * Data Interface USB * GPS false * If yes | - | - | - |
| Capable to display the geolocation of test inspection location NA * Camera false true | - | - | - |
| false If yes | - | - | - |
| Capable to capture the clear image of test target NA * PRINTER Printer Without With | - | - | - |
| Without Type of Printer NA Portable Dot Matrix Printer with Wireless Bluetooth Connectivity | - | - | - |
| Portable Inkjet Printer with Wireless Bluetooth Connectivity | - | - | - |
| Portable Laserjet Printer with Wireless Bluetooth Connectivity | - | - | - |
| Internal Thermal Printer | - | - | - |
| NA Print Resolution (dpi) 200 * Printer consists of Inbuilt Rechargeable Battery | - | - | - |
| Paper for offence printouts | - | - | - |
| Charger NA * Minimum number of printouts that can be taken with the paper available with the Printer 1000 * "Minimum number of printouts that can be 100 * 3/5 taken with single charge of the printer battery (Hint:- Minimum 60 prints | - | - | - |
| if 'With Printer' May indicate '0' if not applicable)" Bis Registration number for Printer under CRS of MeitY IS 616:2010 R-41000027 * WARRANTY Warranty 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 (or higher) STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement | - | - | - |
| The instrument is hand held | - | - | - |
| portable and easy to operate true * If Yes | - | - | - |
| the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface | - | - | - |
| meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature 0 * Maximum Operating Temperature 50 * Relative Humidity Non Condensing (%) 95 * ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest true * Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest true * Conformity to Cold test at - 5/-10/- 15/-20 degree C (as true * 4/5 applicable) for 4 hours as per IS: 9000 latest Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification true * Test Report Number and Date GB11/84488 DATED 10/12/2015 * Name of the Lab and Address SGS | - | - | - |
| 202B WORLEY PARKWAY | - | - | - |
| U.K. * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Buddhilal Prasad 233001 | - | - | - |
| CMO District Hospital Gorabazar Ghazipur 1 15 | - | - | - |
Exempted
26 Oct 2018
29 Aug 2018
contract_GEMC-511687706770357.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_538595.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .