Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | Admitted-Finance |
| 2 | Admitted-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | Admitted-Finance |
| 3 | Admitted-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
20 Sept 2022, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIS MAINT TO PUMP SETS LT PANELS PUMP SETS STAIRCASE CABLE AND CONNECTED ACCESSORIES AT NOFRA AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_547181_1
8264/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D Category a(ii) b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹99,800
Yes
27 Sept 2022
24 Aug 2022
21 Sept 2022
24 Aug 2022
20 Sept 2022
7 Sept 2022
24 Aug 2022 - 13 Sept 2022
Amount
Supply ,install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 600A capacity copper bus bar (4 Nos) All MCCB shall be connected with 600 Amp of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc with suitable Cable alley for provn of cable entries at bottom with cable glands including the following :- (a) MCCB 4 pole, 415V,400Amps 50 KA - 01 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100% Make :L&T/ABB/Siemens/legrand (b) MCCB 3 pole,415V,250mps 50 KA - 03 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% Make L&T/ABB/Siemens/legrand (c) Automatic star/Delta starters panel with all accessories mounting suitable for 75 HP-03 Nos. Make :L&T/ABB (d) Phase indicating lamps(RYB)-04 set (e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set. Make: Dip/AE/IMP (f) Suitable CTs for main and for 03 starter panels.
Supply ,install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc with suitable Cable alley for provn of cable entries at bottom with cable glands including the following :- (a) MCCB 4 pole, 415V,630Amps 50 KA - 01 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100% Make :L&T/ABB/Siemens/legrand (b) MCCB 4 pole,415V,630Amps 50 KA - 01No (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% Make L&T/ABB/Siemens/legrand (c) MCCB 4 pole,415V,100Amps 16 KA - 02Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% Make L&T/ABB/Siemens/legrand (d) MCB 4 pole , 63 Amps, 10 KA, 'C' Series -03 Nos (e) Phase indicating lamps(RYB)-04 set (f) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-01 set. Make: Dip/AE/IMP
Supply ,install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :- (a) MCCB 4 pole, 415V,630Amps 50 KA - 02 Nos (incoming) thermo magnetic adjustable release type,ICS=ICU=100% Make :L&T/ABB/Siemens/legrand (b) On load change over switch 630 Amps, 4 pole, 415 volts-01 No. Make L&T/ABB/Havells/Standard (c) MCCB 4 pole, 415V,400Amps 50 KA - 03 Nos (Out going) thermo magnetic adjustable release type,ICS=ICU=100% Make :L&T/ABB/Siemens/legrand (d) Phase indicating lamps(RYB)-04 set (e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-01 set. Make: Dip/AE/IMP
Supply ,install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 300A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :- (a) MCCB 4 pole, 415V,160Amps 36 KA - 01 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100% Make :L&T/ABB/Siemens/legrand (b) MCCB 3 pole,415V,63 Amps, 36 KA - 03 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% Make L&T/ABB/Siemens/legrand (c) Automatic star/Delta starters panel with all accessories mounting suitable for 20 HP-03 Nos.Make :L&T/ABB (d) Phase indicating lamps(RYB)-04 set (e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set. Make: Dip/AE/IMP (f) Suitable CTs for main and for 03 starter panels.
Taking down old unserviceable panel boards of any capacity and disconnecting cable connections from incoming and out going and making good to the disturbed surfaces all as specified and directed.
Supply and fixing in repair LED street light luminaire 60 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDsand secondary lenses with IP-66 protection, Efficeincy : 110LM/W, 10 KV SPD included complete including making connections with copper wire 1.0 sqmm complete all as specified and directed. Make :- Crompton product No. LSTP-60-CDL-M or equivalent in Havells/Philips
Supply and fixing three phase off load change over switch with handle made out of sheet metal enclosure of capacity 400 Amps, 4 pole, side handle, 415 Volts, 50 Hz complete fixing on wall with grouting of base frame and suitable nut bolts all as specified and directed Make :- Havells/L&T/Siemens
Supply and fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 core in trench/wall with suitable saddles or under ground as required at site complete including lugs complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in soft/hard soil in any type, complete all as specified and as directed .
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Returning & filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm as in soil complete all as specified & directed .
Supply and fixing in repair HDPE Pipe of size 150 mm bore, PN 10 including jointing with collars/bends complete all as specified and directed.
M&L for replacement of Earthing completely using Copper Bonded Rod of diameter more than 15mm and length of 10 feet below ground level .The material shall be low carbon high tensile copper bonded rods with 99.9 % of copper on the surface. pit shall be filled with highly conductive and eco friendly ground enhancing compound as per IEC 62561- 7 shall be not less than 30Kg per pit & PCC 1:3:6 Earth Pit chamber of size 310mm×300×170mm(W×L×H) with Cast iron cover complete all as specified and directed
S&F in repair Earth continuity conductor or main earthing lead of size 25× 4mm GI fixed to wall using insulated earth strip at every 2 feet ditsance earthing strip should be fixed from 6th to ground floor and necessary termination with nuts and bolts complete all as specified and directed
Demolition of Exisiting concrete supporting block of pumps and motor exceeding 15cm of thickness above and below ground level all specfied and directed by Engineer-in-charge
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of Base frame with MS bolts placed in concrete and hardstanding finishing even and fair without using extra cement all as specified. Note: Location of bolts and size of bolts should macth the previous one
M& L for Disconnecting centrifugal pump from motor, suction and delivery pipe line of any Make, model and taking down packing for removing and insertion of new shaft sleeves or remove Bearing using bearing puller gear and fix new bearings and greasing all parts, coupling pump to motor and check for proper shaft alignments such that no vibration produce during opertion of following capacity pumps, complete all as specfied and as directed by Engineer-in-charge.
Pump coupled with 75 HP motor (Bearing Size 6309-ZZ & 3309)
Pump coupled with 60 HP motor (Bearing Size 6308 ZZ & 3308)
Pump coupled with 50/40 HP motor (Bearing Size 6307 ZZ & 3307)
Pump coupled with 30/20 HP motor (Bearing Size 6306 ZZ & 3306)
M& L for Disconnecting motor from pump of any Make, model and remove Bearing using bearing puller gear and fix new bearings at DE /NDE including necessary greasing ,check for proper shaft alignments such that no vibratiobn produce during opertion of following capacity Motors.
Pump coupled with 75 HP motor (Bearing size 6313-ZZ & 6312ZZ
Pump coupled with 60 HP motor (Bearing size 6312 ZZ & 6311ZZ
Pump coupled with 30/40 HP motor (Bearing size 6311 ZZ & 6308ZZ
Pump coupled with 15 HP motor (Bearing size 6307 ZZ & 6309ZZ
Pump coupled with 20 HP motor (Bearing size 6309 ZZ & 6308ZZ
S&F in repair AC-3 type contactor with control voltage of 230V AC with integrated auxillary or Add on block contacts with 1 or 2 NO and NC including connection of control wiring to contactor and testing of starter after repairing .
Contactor rating of 115A Make L &T/Havells/ABB
Contactor rating of 75A Make L &T/Havells/ABB
Contactor rating of 65A Make L &T/Havells/ABB
Contactor rating of 40A Make L &T/Havells/ABB
Contactor rating of 32A Make L &T/Havells/ABB
Contactor rating of 22A Make L &T/Havells/ABB
Contactor rating of 18A Make L &T/Havells/ABB
S&F in repair Thermal over load relay with adjustable setting with integrated auxillary or Add on block contacts with 1 or 2 NO and NC including connection of control wiring to OLR and testing of starter after repairing .
OLR of capacity I Min of 45 to I max 65A Make Siemens/ABB/Schneider
OLR of capacity I Min of 34 to I max 50A Make Siemens/ABB/Schneider
OLR of capacity I Min of 20 to I max 32A Make Siemens/ABB/Schneider
OLR of capacity I Min of 12 to I max 18A Make Siemens/ABB/Schneider
OLR of capacity I Min of 08 to I max 12A Make Siemens/ABB/Schneider
S&F self lubricated asbestoes non metallic and non graphite gland packing white colour of sizes 8 to 12 mm complete all as specified and directed Make : Champion or techno and commercial equivalent
M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 75 HP motor
M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 60 HP motor
M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 40 HP motor
M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 15/20 HP motor
M&L for Disconnecting motor power cables of various sizes from electrical motor of different capacities and decoupling from the pump sets,removing and taking down carefully and transporting to authorised workshop ,Dismantaling stator and rotor carefully and rewinding stator assembly with supper enamelled copper winding wire of suitable gauge matching to existing gauge and cleaning of slots ,core with carbon tetra chloride solution and apply two coats of insulation varnish and keep stator assembly in heating chamber to improve insulation strength ,reassemble motor completey and transporation to site ,coupling pump to motor and check for proper shaft alignments such that no vibratiobn produce during opertioncoupling to pump with exact allinment ,connect power cables to motor and testing of following capacity motor
S&F in repair and replacemnt of MCCB of following capacity including disconnecting the cable, replacement of burntout lugs, spreaders of suitable size including nuts and bolts and fixing to existing panel including necessary alternation to existing busbar and panel all as specfied and directed by Enginner-in-charge :- Make of MCCB :- Havells/L&T/Siemens/ABB
MCCB of 630A ,Breaking capacity 50KA,4P with adjustable thermal magnetic setting Ics=Icu=100%
MCCB of 400A ,Breaking capacity 50KA,4P with adjustable thermal magnetic setting Ics=Icu=100%
MCCB of 320/350A ,Breaking capacity 50KA,4P with adjustable thermal magnetic setting Ics=Icu=100%
MCCB of 250 A ,Breaking capacity 36KA,4P with adjustable thermal magnetic setting Ics=Icu=100%
MCCB of 200 A ,Breaking capacity 36KA,4P with adjustable thermal magnetic setting Ics=Icu=100%
MCCB of 125 A,Breaking capacity 16KA,3P fixed type
MCCB of 100 Amp, Breaking capacity 16 KA , 3P fixed type
MCCB of 250 A ,Breaking capacity 36KA,3P with adjustable thermal magnetic setting Ics=Icu=100%
MCCB of 200A,Breaking capacity 36KA,3P with adjustable thermal magnetic setting Ics=Icu=100%
S&F in repair and replacemnt of burnout aluminium spreaders incoming or outgoing of following size including nuts and bolts all as specfied and directed by Engineer-in-charge
S & F in repair pressure gauge 150mm dia range 0-10Kg /Sqcm. Note: quoted rated should including for providing of adopter /Ferrule/check nut etc required for fixing pressure guage and necessary alterations including necessary welding to MS or CI pipe for taping if required.
Supply and laying in replacement of copper unamoured power cable of size 25sqmm from motor starter panel to motor in HDPE pipe in ground
Supply and laying in replacement of copper unamoured power cable of size 35sqmm from motor starter panel to motor in HDPE pipe in ground
Supply and laying in replacement of copper unamoured power cable of size 50 sqmm from motor starter panel to motor in HDPE pipe in ground
Material and labour for bacteriological and chemical analysis of water sample at govt approved lab (Iso 9001:2008)including collecting sample from pumphouse using labed owned sample jar and testing every month all directed and specfied by Enginner-in-charge
Supply and Lay in repair LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 Core x 10 Sqmm complete all as specified and directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is including in the quoted rate and no extra payment will be made for it. 2. The excavation, earth work, sand cushioning and brick protection etc will be measured and paid separately under respective items.
S & F in repair looping box of size 130mm x 130mmx77mm weather proof IP66/67 including connector blocks four way having suitable size bolt to connect upto 6sqmm x 2 core cable two Nos with the help of suitable gland, thimble nuts, washers supports by flat aluminium clamps not less than 25 mm x 3mm with suitable size nuts, bolts and washers inside and outside looping box including fixing with electric pole and taking out old one of any type complete as directed. Make : Hansel , Cat ref : KF3535G. or equivalent make as approved by Engr-in-charge.
Scrapping of paint complete pump and motor, base frame and accessories complete including making new synthetic enamel paint of two coats over a coat of red oxide primer of motor of capacity 15 HP to 75 HP complete all as specified and directed.
Supply and fixing in repair fabrication of Iron frames size and thickness as per existing on site including nut bolts, washers , two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing in repair rubber vibration pads heavy duty for base frame as per sample suitable for the following size of pumpsets :-
Cutting cast iron pipes/DI pipes and reducing to required length before laying in position for insertion of new tees, branches, for the following sizes :-
150 mm bore
200 mm bore
300 mm bore
Supply and fixing DI/CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete any type of fittings up to 150 mm bore
Supply and fixing DI/CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete any type of fittings 200 mm to 300 mm bore.
Supply and laying in replacement of spigot and socket ductile iron water tubing having cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329:2000, including rubber joint of suitable size, class K-9 laid on wall/roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed.
150 mm bore
200mm bore
300mm bore
Darpan Construction
Shree Ayyappa Engineering
BOB ENTERPRISES
Shetty Construction Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .