Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAdmitted-Finance | ₹21.2 L | L1 | Admitted-Finance |
| 2 | L2₹23.5 LAdmitted-Finance | ₹23.5 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical B 008 VASANI COMPLEX BEHIND OLD PETROL PUMP NEAR BELVALI SUBWAY BADLAPUR EAST BADLAPUR 421503 | BADLAPUR | THANE | MAHARASHTRA | 421503 | - | - | Rejected-Technical All tender documents are not submitted |
| Sl No | Description | Qty | Unit | TAKSH ENTERPRISES L1 | MUJAWAR ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing & Commissioning of Equipment involving Atmospheric Control System & Maintainance Work for Class room at Dr. R. N. Cooper Hospital. | |||||
| 1.01 | Nominal Capacity 2.0 TR (6050 Kcal / Hr. ( 1 indoor unit of 2.0 TR & 1 outdoor unit of 2.0 TR ) | 4 | Nos | 59,919.81 ₹2.4 L | 66,351.88 ₹2.7 L |
| 1.02 | Providing & fixing of platform and M.S. Railing for Outdoor units of Split AC to facilitate smooth access to technician to safely carry out maintenance . | 4 | Job | 11,211.18 ₹44,844.72 | 12,414.64 ₹49,658.56 |
| 1.03 | Providing & fixing of M.S.Cage / encloser for 1.0 TR/ 1.5 TR, 2 TR window A.C. & 1.0 TR/ 1.5 TR/2.0 TR Split A.C Units.. | 4 | Nos | 9,716.42 ₹38,865.68 | 10,759.42 ₹43,037.68 |
| 1.04 | Providing & fixing of Refrigerant piping including electrical cabling & earthing as per specification. | 200 | Mtr | 1,557.6 ₹3.1 L | 1,724.8 ₹3.4 L |
| 1.05 | Providing & fixing of Drain piping as per specification. | 4 | Nos | 261.96 ₹1,047.84 | 290.08 ₹1,160.32 |
| 1.06 | Supply and fixing of M.S. stand & Bracket for fixing of indoor & outdoor of 2/3 TR Tower AC. | 4 | Nos | 9,342.95 ₹37,371.80 | 10,345.86 ₹41,383.44 |
| 1.07 | 1st category Cu armoured cables FRLSZ outer sheathed- 4C x 4 Sq.mm | 150 | Mtr | 247.8 ₹37,170 | 274.4 ₹41,160 |
| 1.08 | 1st category Cu armoured cables FRLSZ outer sheathed- 4C x 16 Sq.mm | 150 | Mtr | 920.4 ₹1.4 L | 1,019.2 ₹1.5 L |
| 1.09 | 32A 4P MCB | 4 | Nos | 1,935.5 ₹7,742 | 2,143.26 ₹8,573.04 |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
17 Mar 2026, 5:00 pmClosed
Dean Dr. R. N. Cooper Mun. Gen. Hospital
Dr. R. N. Cooper Mun. Gen. Hospital
Supply, Installation, Testing and Commissioning of Equipment involving Atmospheric Control System and Maintenance Work for Class room at Dr. R. N. Cooper Hospital.
2025_MCGM_1223783_1
HO/165/RNCH/DTD. 28.04.2025
Open Tender
Electrical Works
30 days
Dr. R. N. Cooper Mun. Gen. Hospital. Vile Parle W
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,567
₹29,000
23 May 2026
10 Mar 2026
18 Mar 2026
10 Mar 2026
17 Mar 2026
10 Mar 2026
Supply, Installation, Testing & Commissioning of Equipment involving Atmospheric Control System & Maintainance Work for Class room at Dr. R. N. Cooper Hospital.
Nominal Capacity 2.0 TR (6050 Kcal / Hr. ( 1 indoor unit of 2.0 TR & 1 outdoor unit of 2.0 TR )
Providing & fixing of platform and M.S. Railing for Outdoor units of Split AC to facilitate smooth access to technician to safely carry out maintenance .
Providing & fixing of M.S.Cage / encloser for 1.0 TR/ 1.5 TR, 2 TR window A.C. & 1.0 TR/ 1.5 TR/2.0 TR Split A.C Units..
Providing & fixing of Refrigerant piping including electrical cabling & earthing as per specification.
Providing & fixing of Drain piping as per specification.
Supply and fixing of M.S. stand & Bracket for fixing of indoor & outdoor of 2/3 TR Tower AC.
1st category Cu armoured cables FRLSZ outer sheathed- 4C x 4 Sq.mm
1st category Cu armoured cables FRLSZ outer sheathed- 4C x 16 Sq.mm
32A 4P MCB
15 / 5 A / 6 A Combined Power Plug Socket Point with Fuse and Indicating Lamp, One 15 Amp SP Switch
Removing/ Dismantling of old 1.0/ 1.5 TR/ 2.0 window/ split AC/ FCU/ Cassette unit.
Installation, testinng and commissioing of Split AC unit
Providing & fixing of platform and M.S. Railing for Outdoor units of Split AC to facilitate smooth access to technician to safely carry out maintenance .
Providing & fixing of M.S.Cage / encloser for 1.0 TR/ 1.5 TR, 2 TR window A.C. & 1.0 TR/ 1.5 TR/2.0 TR Split A.C Units..
Providing & fixing of Refrigerant piping including electrical cabling & earthing as per specification.
Providing & fixing of Drain piping as per specification.
Comprehensive service & maintenance charges of 1.5 TR capacity Split AC unit for a period of 12 months
Supply and fixing of M.S. stand & Bracket for fixing of indoor & outdoor of 2/3 TR Tower AC.
1st category Cu armoured cables FRLSZ outer sheathed- 4C x 4 Sq.mm
1st category Cu armoured cables FRLSZ outer sheathed- 4C x 16 Sq.mm
32A 4P MCB
15 / 5 A / 6 A Combined Power Plug Socket Point with Fuse and Indicating Lamp, One 15 Amp SP Switch
Reffiling of gas
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
SBD.pdf
Tender Documents • 3.91 MB
BOQ_2210563.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid