Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
12 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ KRISHNA PATIL
GE (P) NORTH PORT BLAIR
REPAIR/MAINT OF SEWAGE LINE, CLEANING OF SEPTIC TANK, MANHOLE AND WATER TK, TILING AND CERTAIN MISCELLANEOUS WORKS AT ICGS HUT BAY
2020_MES_323470_4
8990 - REPAIR/REPLACEMENT OF SEWAGE WKS HUT BAY
Open Tender
Civil Works
Item Rate
270 days
HUT BAY LITTLE ANDAMAN
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (P) NORTH PORT BLAIR
₹36,000
Yes
15 Feb 2021
22 Jan 2021
15 Feb 2021
22 Jan 2021
12 Feb 2021
28 Jan 2021
22 Jan 2021 - 28 Jan 2021
60 days
Amount
SCHEDULE 'A' : PART -I (B/R Portion) :- Cleaning and removing all scales and dirt from tanks and from mouths of circulating pipes incl use of bleaching powder for the same, capacity of tank exc 250 and n.exc 500 ltr complete all as spd and directed
Cleaning and removing all scales and dirt from tanks and from mouths of circulating pipes incl use of bleaching powder for the same, capacity of tank exc 500 and n.exc 1000 ltr complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m depth for foundation etc and n.exc 10 Sqm on plan and getting out in Soft/Loose soil
Returning filling in soil including spreading, leveling, watering & well ramming in layers n.exc 25 cm
M & L for PCC bed of (1:3:6) type C2 (using 40mm graded aggregates) to drain pipes including packing under and haunching against the side of pipe, 100 mm dia bore complete all as specified and directed by Engr-in-Charge
Removing excavated materials n.exc 50mm and depositing where directed at a level n.exc 1.5m above the starting point in soil.
Dismantling of cast iron/ PVC pipes jointed in cement mortor and taking out of trenches, 150 mm nominal bore of pipe
M & L for providing cast iron soil, waste and vent sand cast pipes in any length, with or without ears with cement joints laid in trenches or in floors, pipes of bore 100 mm dia, incl necessary fixtures like bends, branch pieces etc as required.
Cutting into existing manholes for removing existing branch drain making good to walling and rendering cutting out branch channel and making good benching for 100 mm dia bore of pipe
Demolition and breaking up AC/PVC /Salt glazed ware drain pipe n.exc 100 mm dia bore pipe set in cement mortar and make good to surface, all as specified.
M & L for excavation in post hole (or similar holes) each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer not exc 25 cm watering and removing surplus soil to a distance not exc 50 m and making surface all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) pipes, single socketed, 110 mm dia bore of pipe. Laid in floors or trenches as in waste, sewage pipes, complete all as specified and as directed by Engr-in-Charge
S & F in repairs, HDPE pipes, with pressure rating 6kg/cm2, laid in trenches as in waste pipes incl dismantling existing damaged pipes and making food to surface 50 mm dia bore of pipe.
Taking out carefully precast RCC slabs of septic tanks, taking out the sludge/debris in water in closed container and depositing in an earthen pit of sufficient size and any type of soil with the defence land where directed to a distance exc 250 m and n.exc 500 m, returning filling in earth into excavated pit after every disposal of scum/sludge, cleaning the inspection pit, sludge chamber inlet and inspection pipe and outlet pipe, cleaning MS rungs and applying one coat of linseed oil complete for septic tank capacity 25 users to 100 users each, all as specified including cleaning the septic tanks with fresh water and bleaching powder and refixing the removed cover slabincl necessary cambering to edges as required in CM (1:4) and necessary touch-up with cement base paint all as directed by Engr-in-Charge.
M & L providing precast cement concrete 1:2:4, Type B-1(20 mm graded aggregate) as in cover slabs (for manholes etc) and similar articles with plain faces set in cement mortar 1:4. All as specified and directed by Engr-in-Charge.
Taking out carefully the covers slabs of manholes of any size, depth and removing the sludges to a distance exc 250 m and n.exc 500 m incl cleaning the inside with fresh water and bleaching powder and placing the cover slabs back incl necessary cambering to edges as required in CM (1:4) and necessary touch up with cement base paing all as directed by Engr-in-Charge.
Demolition of bamboo framing any type in walls incl attached whole bamboos or bamboo trellis work all as specified
Cleaning with fresh water and bleaching powder, the blockages in sewer line of 100 mm dia pipes, in between manholes and passing rubber ball/sponge ball/similar means through the line to ensure cleaning of all blockage complete all as specified.
M & L for Figured glass, 4mm thick, pin head type and glazing with oil putty in squares n.exc 0.5 Sqm in each pane incl hacking out old broken glass pane from windows frames
M & L Welding in repairs exc 2.5cm but n.exc 5 cm in length all as specified and directed.
S & F in repairs, Mild steel barrel tower bolts, 100 mm, stove enamelled black, with bright bolt, complete all as specified and directed.
S & F in repairs, mild steel peg stays exc 175 mm & n.exc 250 mm weided to steel windows, fixed with necessary bolting, complete all as specified and directed.
Taking down chowkhat or frame with shutters (without taking of shutter from frame) exc 1.5 sqm and n.exc 4.00 sqm each complete all as specified.
Taking down shutters exc 1.0 sqm and n.exc 2.0 sqm each complete all as specified.
S & F in repair aluminium anodised, barrel tower bolt of extruded section, 150 mm long, fixed in repair all as specified.
S & F in repair extruded aluminium alloy handles, fabricated type, anodised 150 m size fixed in repairs.
S & F in rapri aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cost or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy, 300 mm length fixed in repairs
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing the debris of the premises complete all as specified and directed.
S & F Mild steel work such as F.I horizontal and vertical incl securing bolt in post and strut as in fencing incl cutting top to shape, drilling hole, notching for wire etc and similar work conforming to Fe-290 Gde E-165 all as specified and as directed by Engr-in-Charge
M & L for coloured chequered concrete tiles, 30 cm x 30 cm x 25mm thick, set jointed and pointed in neat cement sturry with grey cement and pigment, pattern as directed by Engr-in-Charge on floors.
S & F in repairs, 15mm dia fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle screwed down for iron pipe
S & F in repairs, 15mm dia fancy type chromium plated pillar taps, cast copper alloy with crutch or butterfly handle screwed down for iron pipe
S & F in repairs, Brass CP mixer tap for mixing hot & cold water screwed down for iron pipe, 15 mm dia bore complete all as specified and directed.
S & F in repairs, Chromium plated shower roses with or without swivel joints, 15 mm dia bore, including fixing to steel pipe or union, complete all as specified and directed.
S & F in repairs, curtain rails 20 mm dia, chromium plated with necessary decorative fixing brackets as approved etc all as spoecified and directed by Engr in-Charge.
M & L precast reinforceed cement concrete type B-1, 1:2::4 (20 mm graded aggregatge) for cattle post, fencing post, straining or terminal posts, struts etc for fencing, average sectional area n.exc 100 Sq cm all as specified and as directed by Engr-in-Charge.
S & F Mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required including cranking bending spirally for hooping for cvloumns, hooking ends and binding with and including mild steel wire (annealed) not less tha 0.9 mm dia or securing with clips complete all as specified.
Demolition of stone slabs in cover of man hole, etc of any thickness jointed in any mortar complete all as specified and directed by Engr-in-Charge
S & F in repairs, 10 Ltr PVC valveless, syphonic action type flushing system, low level, white, with inlet , ball valve, float and handle including brackets complete all as specified and as directed by Engr-in-Charge.
S & F in repairs, 15 mm dia GI tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floor including taking down existing old steel tubing.
S & F Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed for 15 mm bore of pipe.
Demolition of cement concrete in any description and in any position not otherwise provided for etc all as specifised.
M & L Cement concrete in foundations, filling and mass concrete, Type D2, 1:4:8 (using 40 mm graded aggregate) complete all as specified and directed.
M & L for preparation of old painted wall surfaces and applying one coat of distemper oil emulsion.
M & L for preparation of old painted ceiling surfaces and applying one coat of distemper oil emulsion
S & F Mild steel bars 5mm dia and over upto andincluding 10 mm dia in stirrups, spacers and binders cut to length, bent to shape required, complete all as specified.
Supply only PVC coated GI chain link mesh of size 50 x 50 mm, 3.6 mm dia GI wire with 1 mm thick PVC coating incl taking down the existing chain link fencing complete all as specified.
Fixing only chain link fencing etc complete all as specified and directed.
M & L for PCC 1 : 2 : 4 type B-1 (using 20 mm graded aggregate) as in bed block for hold fast etc, complete all as specified and directed by Engr-in-Charge.
M & L for preparation of old painted surfaces and applying one coat of cement base paint.
M & L for preparation of old painted surfaces of steel /iron surfaces by cleaning down surfaces exc 10 mm width or girth & applying one coat of synthetic enamel paint all as specified.
M & L for preparation of old painted surfaces of wood and applying one coat of Synthetic enamel paint to surfaces of any description, not otherwise described over 10 cm width or girth all as specified and directed.
Demolition of block masonry build in cement mortar complete all as specified and directed.
M& L precast cement concrete solid block, Type C1 1:3:6 (using 20 mm graded aggregate) block masonry with solid block, exc 10 cm in width and setting in CM (1:6) complete all as specified and directed
M & L Precast cement concrete Type 1:3:6 using (20 mm graded aggregate) for hollow block, 10 cm thick, set in cement mortar (1:4) complete all as specified and directed.
Rendering 15 mm thick cement plaster (1:4) on other than fair faces of brick work or concrete surfaces/external surfaces and finishing the surfaces fair and even.
S & F mild steel for hold fasts and similar small articles conforming to Fe-290 Gde-E-165 all as specified.
M & L for preparing new surface of steel/iron surface of any description n.exc 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of primer (red oxide zinc chrome)
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing the debris of the premises complete all as specified and directed.
M & L for screed bed or bedding layer of mortat 15 mm thick in cement mortat 1 : 4 for laying floor finishes complete all as specified.
M & L for non skid ceramic coloured tiles, 7 to 8 mm thick (Square/rectangular) area of tile exc 0.06 sqm and n.exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloureed cement to match over a screed bed or bedding layer 15 mm thick in CM (1:6) all as specified.
M & L for Glazed ceramic pattern tiles, coloured 350 x 250 x 7mm thick, as in vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match, incl border tiles, design/pattern as directed by Engr-in-Charge, backing plaster 10 mm thick in CM ( 1 : 4) finished rough, complete all as specified.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exc 15 cm thickness below or above ground level) complete all as specified.
M & L for PCC (1:4:8) Type D-2 using 40 mm graded aggregates as in sub base to floor 100 mm thick.
M & L for cement concrete 1 :2 : 4 (Type B-1, 100 mm thick, using 20 mm graded crushed stone aggregate as in floor and finished even and smooth without using extra cement complete all as specified
M & L for forming expansion joints, 12 mm wide filled with performed bituminous filler and top 30 mm primed and sealed with sealing compound grade - A for entire thickness of 125 mm for the slab.
M & L for forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound
S & F door closer hydroulically regulated designation No-3 universal type alm extruded section body.
S & Fsinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantiliver brackets and connecting union to pipe, overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified.
M & L non absestos fibre cement building boards 4mm thick, fixed or laid/ inserted to anodised Aluminium frame works / snap grids as in false ceiling all as specified. Hangers 6 mm dia GI (upto 1200 mm in length) adjusting levels fixed to roof slabs by ceiling cleats made of GI flat 40 x 3 mm size 60 mm long complete incl dismantling of old flase ceiling boards along with grid.
S & F in repairs, Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, incl securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured).
S & F in repairs Punched Tape concertina Coil of 610 mm openable/ streachable to 6M round type, 51 spiral core wire, made out of 2.5 mm high tensile strength wire galvanised of tensile strength 1500 mpa as specified in IS 4454 incl necessary wire or fixing coil on security / compound wall with Y shaped M/S angle complete all as specified.
Cleaning and removing all scales and dirt from UG sump and from mouths of circulating pipes incl use of bleaching powder for the same, capacity of UG Sump 30000 litre capacity complete all as specified and directed.
S & F Flush shutters of thickness 30 mm, solid core construction with block board core and plywood face panels, both face is covered with decorative faces veneer with lipping / frame to match.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS Tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Pannelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site as per specifications.
S & FI Solid PVC Door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling & Fixing in opening as per specification & drawing.
S & F Butt hinges 100 mm medium weight, cold rolled mild steel
SCHEDULE 'A' : PART -II Internal Electric supply:- Taking down carefully copper/aluminum existing point wiring (light/fan/socket or power points) complete incl fixctures and fittings such as switches, ceiling roses, pendants, regulators sockets light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc. .
Taking down of old MCB DB of any size
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core multistanded copper conductor cable 1.5 swmm drawn in and including casing - caping and accessories , fixed on wall / ceiling etc with necessary fixing accessies and earth continuity conductor cable of 1.5 sqmm size connected to common earth and earth dolly including 2mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with cadmium plated machine screws all as specified for the following :- (a) One light / fan / bell point controlled by one switch
(b) One 5A 2 Pin/3pin socket out let multipurpose on the same board with other switches
(c) One 5A 2 Pin/3pin switch socket out let multipurpose on indeptendent Board.
(b) One 5A 2 Pin/3pin socket out let multipurpose on the same board with other switches
(c) One 5A 2 Pin/3pin switch socket out let multipurpose on indeptendent Board.
All as per item No 2.03 above but wiring complete with 2.5 sqmm for 3 pin 15 A socket multipurpose on independent board.
S & F in repairs witch piano single pole flush type 5A, 240 V one way
S & F in repairs Bell push flush type 5 amp, 250 Volts
S & F in repairs switch socket combination 2 in 1, 5 Amps multipurpose flush type.
S & F in repairs switch socket combination 2 in 1, 3 Pin, 5 & 15 Amps flush type universla
Supply and fix in repairs ceiling rose surface bakelite three terminal 240 V.
S & F in repairs electronic regulator step type 2 module type 240 V suitable for ceiling fan
Supply and fix in repairs bell ding dong AC 230 V single pole
Supply and fix in repairs Retro LED tube rod 20 Watts, 230 Volts with high efficency PMMA diffuser, the rod shall conform to Cat No LTT8-20 of Crompton or equivalent from Philips/Bajaj
S & F in Repairs decorative box type batten prewired for Ewreo LWS light tube 20 Watts, 230 Volts incl fixing mounting block 2 Nos, 1.5 sqmm 3 core PVC insulated copper conductor cable. The fitting shall conform to Cat No IGP131LT8-16 of Crompton or equivalent from Philip/ Bajaj
S & F in Repairs Retro LED tube rod 08 Watts, 230 volts with high efficency PMMA diffuser, the rod shall conform to Cat No LTT8-8 of Crompton or equivalent from Philips/ Bajaj
S & F in repairs decorative box type batten prewired for Retro LED light tube 8 watts , 230 Volts incl fixing mounting blocks 2 Nos, 1.5 sqmm 3 core PVC insulated copper conductor cable. The fitting shall conform to Cat No DMLNILT8-8 of Crompton or equivalent from Philips/ Bajaj
S & LED mirror light fitting 07 watts , including drivers & LED with high output PMMA diffuser for glare free light. The fitting shall conform to Cat No LCL-07-CDL of Cromption or equivalent from Philips / Bajaj
S & F in repair MCB DB Double Door SPN 8 way 240 volts, Make Legrand/ABB/Schnider
S & F in repair MCB DB Double Door SPN 12 way 240 volts, Make Legrand/ABB/Schnider
S & F repair single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as soecified and as directed.
S & F in repair MCB SP, 240 Volt, 6 to 32 Amps, 10 KA, C Curve
S & F in repair MCB SP, 240 Volt, 40 Amps, 10 KA, C Curve
S & F in repair MCB SP, 240 Volt, 63 Amps, 10 KA, C Curve
M & L for sub main wiring with two single core 4.0 sqmm PVC insulate FR multistranded flexible copper conductor cable 660 / 1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dully all as specified and as directed Note : Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
Supply & Lying of 25 mm dia CPVC pipes SDR 11 & including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, including taking down of unserviceable pipe complete all as specified.
Supply & Lying of 50 mm dia CPVC pipes SDR 11 & including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, including taking down of unserviceable pipe complete all as specified.
S & F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for 50 mm dia iron/ CPVC pipe and fixed including all fittings and accessories.
S & F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for 25 mm dia iron / CPVC pipe and fixed including all fittings and accessories.
S& F in repairs gun metal globe valves of 50 mm dia, screqed down, high pressure, with iron wheel head handle, screwed both ends for iron pipe including unions and fixed including providing union as required.
S& F in repairs gun metal globe valves of 25 mm dia, screqed down, high pressure, with iron wheel head handle, screwed both ends for iron pipe including unions and fixed including providing union as required.
Cleaning of underground sump of capacity 30000 ltrs by pumping out water from U/G sump by pump set as directed at site and taking out the remaining water at bottom by buckets manually as required, cleaning internal surfaces of the sump with wire brush, removing scale and dirt. Taking out soil, sand and mud settled at the bottom and finally cleaning with bleaching powder and making date of cleaning on outside all as directed by Engr-in-Charge
P NAIDU
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .