Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.8 L+₹2.4 L (11.4%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹26.8 L+₹5.4 L (25.2%)Rejected-Finance E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Other then lowest | |
| 4 | L4₹29.3 L+₹7.9 L (36.8%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance Other then lowest | |
| 5 | L5₹34.2 L+₹12.8 L (60.0%)Rejected-Finance 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L5 | Rejected-Finance Other then lowest |
Tender Value
₹40.5 L
EMD Value
₹41,000
Closing Date
8 Jul 2021, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF UNSV INTERNAL ELECTRIC FITTINGS AND VARIOUS TYPE OF CEILING FANS GEYSERS AND MISC INTERNAL E M SERVICES ITEMS INTERNAL ELECTRIFICATION WORK INCL REPLACEMENT OF UNSV VARIOUS LIGHT FITTINGS AND FIXTURES SUBMAIN WIRING MCBs DBs AN
2021_MES_450566_1
GE/NORTH-10/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹41,000
Yes
26 Jul 2021
11 Jun 2021
10 Jul 2021
11 Jun 2021
8 Jul 2021
25 Jun 2021
Amount
Taking down ceiling fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire,down rods, canopies,minor spares,painting and re-winding all as specified and directed. (Note : Rubber Bush, Gun Metal Bush, bearing,capacitor, twin core twisted copper flexible wire, down rods, canopies, winding and paintng are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding from the stater of the ceiling fan any sweep with matching gauge and turns of super enamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Painting of ceiling fan with set of blades of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete all as specified and as directed.
Taking down Exhaust/Ventilation fan of any sweep by unscrewing nut/bolts from its position (high rise bldgs up to 8 storey height) and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire,louvers,shutters,painting,minor spares and re-winding all as specified and directed. (Note : Rubber Bush, Gun Metal Bush, bearing,capacitor, twin core twisted copper flexible wire, Louvers,shutters, winding and paintng are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding of the Exhaust fan up to 300 mm dia with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
All as per above item but 380/450mm Sweep.
All as per above item but ventilation fan up to 200mm Sweep.
Painting of exhaust fan of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete all as specified and as directed.
Taking down pedestal/wall mounted fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,if any spares,flexible connection wire and re-winding all as specified and directed. (Note : Bush, bearing,capacitor, twin core twisted copper flexible wire and winding are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding from the stater of the pedestal/wall mounted fan any sweep with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Supply only for ball bearing number of 6201 to 6204 as required. (Make : SKF/NBC).
Supply only ceiling fan gun metal bush bearing as required
Supply only for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan .
Supply only for PVC holder for condenser housing.
Supply only for twin twisted copper flexible wire size of up to 0.5 sqmm.
Supply only capacitor 0.8/1 Mfd, 240 Volts.(Make/Model- as per sample)
Supply only capacitor 2.5 Mfd, 240 Volts.(Make- Tibcon/Havells/Epico)
All as per above but 3.15 Mfd.
All as per above but 4.0 Mfd.
Supply only PVC canopy for ceiling fan.
Supply only down rod for ceiling fan 1' length, down rod colour match with exist fan to any height complete all as directed.
All as per above but 2' length.
M&L for 50x6mm thickness MS strip with nut,bolt and washers suitable for fixing of ceiling fan and all as specified and directed.
M&L in repair for GI tubing 40 mm bore (medium grade) for fixing of ceiling fans and make good the disturbed wall surface and all as specified and directed.
M&L for ceiling fan blade suitable for 1200mm sweep for complete.
All as per above but 1400 mm sweep.
S&F in replacement louvers with shutter metallic body suitable for single phase 240 Volts AC heavy duty exhaust fan upto 450 mm sweep with necessary fixing accessories after taking down existing all as specified and directed. NOTE: Louver Shutter are to be replaced up to high rise bldgs 8 storey including all necessary T&P and fixing accessories etc.
S&F in replacement louvers with shutter plastic body suitable for single phase 240 Volts ventilation fan 200 mm sweep with necessary fixing accessories after taking down existing all as specified and directed. NOTE: Louver Shutter are to be replaced up to high rise bldgs upto 8 storey, including all necessary T&P and fixing accessories etc.
M&L for exhaust fan blade (metal body) suitable for 300/380/450mm sweep for exhaust fan complete all as directed. (Make as per sample)
M&L for ventilation fan blade (PVC type) suitable for 200mm sweep complete all as directed. (Make as per sample)
M&L for wall/stand fan blade (PVC type) suitable for 300mm sweep complete all as directed. (Make as per sample)
Supply and fixing in repair of 300mm dia, 900 RPM, exhast fan witlh louvers including frame, blades complete and UNSV Ex fan deposit in E/M store yard. . Make: Khaitan/ Crompton Greaves /Havells
Supply and fixing in repair of 300mm dia, 900 RPM, wall mounting fan oscalating type complete and UNSV fan deposit in E/M store yard. . Make: Khaitan/ Crompton Greaves /Havells
Supply and fixing in repair of 200mm dia, 900 RPM, fresh air fan woth plastic louvers incl frame complete and UNSV fan deposit in E/M store yard. . Make: Bajaj/ Crompton Greaves /Havells
Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and replacing the defective parts. descaling with acid washing and reassembling after cleaning and replacing defective parts and re-installing the same in original position with fastner nut and bolts and making necessary electric and water supply connection and testing complete all as specified and directed. (Note: Spare items shall be measured and paid seperately as supply only under relevant items)
Supply only geyser inner water tank 25 Ltrs capacity steel body with nut and bolts as per sample ,duly tested complete all as specified and directed.(Make- as per sample)
Supply only of Heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete all as specified and directed.Make : as per sample
All as per above item but capacity 2 KW.
Supply only thermostat suitable for 25 ltrs capacity geysers as per sample.
Supply only Heavy duty hot water connection, SS rope threaded type with brass unions, neoprene washers at both ends, 45cm long 15mm bore complete.
Supply only cold water connection, PVC connection with brass unions,neoprene washers at both ends, 45cm long 15mm bore complete.
Supply only soft copper pipe chromium plated with unions, neoprene washers at both ends for the inlet and outlet of gesyers, 45cm long 15mm bore complete.
Supply only replacement of safety valve/Pressure release valve for geysers of any type/capacity.
Supply only indicator lamp Red/Green suitable for geyser geysers of any type/capacity.(Make as per sample)
Supply only geyser base plate/apparatus assembly of any capacity any model all as specified and directed complete. Make as per sample.
Supply only geyser top and bottom cover any capacity any model all as specified and directed complete. Make as per sample.
S&F in replacement of glass wool heat resistance thermal type/heavy duty puf insulation glass wool of exist type (8 kgs) for 25 ltrs capacity geysers complete.
S&F in replacement of outer cover MS sheet/ABS body of geysers 25 Ltrs capacity complete all as specified and directed.
M&L soldering/brazing inner geyser tanks 25 liters capacity with brass solder and refixing after testing the leakage complete incl replacement of rubber packaging ring heat resistance type all as specified directed complete.
Material & Labour for spray painting 25 Ltrs capacity with two coats of white synthetic enamel paint (1st quality approved brand ) after preparation of surface all as specified and directed complete.
M&L in repair for Delux stepped type electronic fan regulator flush type, ISI marked on the existing phenolic laminated sheet etc all as specified and directed.
M&L in repair for modular fan regulator, step type,ISI marked complete all as directed.
S & F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps.
S & F in repair industrial type two pin and earth plug top 20 Amps complete.
S&F in repairs for MCB SP, 240 Volts, AC, 16 amps, breaking capacity 10 KA, 'C' curve complete
M&L in replacement of Plug top, 3 pin, 05 amps, 230 volt.
M&L in replacement of Plug top, 3 pin, 15 amps, 230 volt.
S&F surface mounted LED panel type 36W,230V complete with driver full window glarefree opal diffuser LED panel of size 2ftx2ft with CRCA powder coated white housing, CDL/Warm type illumination complete with all accessories required for connection and making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) drawing through existing conduit pipe including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete for the following :-
(a) One light point controlled by one switch
(b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 5 Amps controlled by one switch on same board
(d) One socket outlet 5 amps controlled by one switch on independent board
(e) One bell point controlled by one bell push switch
All as per above item but wiring with 2.5sqmm copper wire and 1.5sqmm earth wire for socket out let 16 Amps on independent board
All as per above item but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories,GI metal flush box of 1.60 mm thick suitable for modular/conventional type switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- (Note: Rates deemed to be included for GI metal flush box, laminated sheet top cover,modular cover inner and outer, blanking plates etc complete).
(a) One light point controlled by one switch
(b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 5 Amps controlled by one switch on same board
(d) One socket outlet 5 amps controlled by one switch on independent board
(e) One bell point controlled by one bell push switch
All as per above item but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
All as per above item but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
M&L for point wiring surface type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC conduit/caping casing of 20mm dia or higher, medium grade complete with all PVC conduit accessories,GI metal flush box of 1.60mm thick suitable for modular/conventional type switches/sockets/ fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the following :- (Note: Rates deemed to be included for surfacemounting plastic boxes,laminated sheet top cover,modular cover inner and outer, blanking plates etc complete).
(a) One light point controlled by one switch
(b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 5 Amps controlled by one switch on same board
(d) One socket outlet 5 amps controlled by one switch on independent board
(e) One bell point controlled by one bell push switch
All as per above item No 9 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
All as per above item but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
S&F in replacement of concealed metal box 06/08 modules having high durability,corrosion resistant,earthing terminal with repalcement of 3 mm thick plastic laminated hylam sheet top cover with brass screws , cup wahser and cutting of grooves for switchs,sockets and regulator etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed.(Note: Switch,sockets,regulators to be measured and paid separately)
All as per above item description but 03/04 modules complete.
All as per above item description but 01/02 modules complete.
S&F in replacement of concealed metal GI box 12/16 modules having high durability,corrosion resistant,earthing terminal with repalcement of modular type inner and outer plate covers with screws, incl all cutting/chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed.(Note: Modular switch,sockets,regulators to be measured and paid separately)
All as per above item description but 06/08 modules complete.
All as per above item description but 03/04 modules complete.
All as per above item description but 01/02 modules complete.
S&F Switch piano flush type 5/6 Amps single pole one way 230 Volts complete
S&F Switch piano flush type 15/16 A single pole one way 230 Volts complete
S&F Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt complete
S&F Socket Outlet 2 in 1, 3/6 pin 5 and 15 Amp flush type 230 Volts complete
S/F Bell push, flush type 5 Amps 230 Volts complete
S&F electronic fan step regulator flush type 120 watt, 230 Volt complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F lamp holder, 230 volt AC, PVC / Polycarbonate type of angular shape with back plate suitable for batten fittings complete
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete.
S&F modular switch 6 Amps, one way, one module 240 volts complete
S&F modular socket, 3 pin 6 Amps,240 volts, 2 module complete
S&F modular switch 16 A, 1 module,240 volts complete
S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts complete
S&F modular Bell push 6 Amps, one module 240 volts complete
S&F modular fan regulator, step type, 120 W, humfree, AC, 230 volts, 2 module complete
Supply and fixing Modular type 25 Amps capacity starter type 2 module type for AC plug unit complete.
S&F in replacement of glass cover for sketch type wall fittings complete all as specified and directed.(Make as per sample)
M&L in repair for two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area 1100 V,stranded copper conductor, multistranded, and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete
All as per above item herein before but with 6 sqmm two runs and 4 sqmm one run as earth wire
All as per above item herein before but with 10 sqmm two runs and 6 sqmm one run as earth wire
All as per above item herein before but with 4 sqmm four runs and 2.5 sqmm one run as earth wire
S&F MCB DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, 4 way IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following :-
All as per above but 8 way
All as per above but 12 way
S&F of factory made distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable complete
S&F of factory made distribution box 8 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable complete
S&F of loadline distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCCB 63/100 Amps as incomer and MCB SP as out going complete
S&F of loadline distribution box 8 way, AC, TP & neutral metal enclosure, glazed double dooor, 415V AC, IP-43, concealed type with IP-43 protection complete with suitable bus bar, neutral link, earth link suitable for MCCB 125/160 Amps as incomer and MCB SP as out going all as directed.
S&F in repairs for MCB TPN, 240 Volts, AC, 63 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete
S&F in repairs for MCB TPN, 240 Volts, AC, 40 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete
S&F in repairs for MCB, DP/SPN, 240 Volts, AC, 63 Amps of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete of following rating :-
All as per above item but 40 Amps
All as per above item but 16 to 32 Amps
S&F in repairs for MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete
S&F in repairs for MCCB 2 Pole, 240 volt, AC, fixed type,32 Amps, 16 kA, suitable for load line DB/LT PB connection complete of following rating :-
S&F in repairs for MCCB 4 Pole, 415 volt, AC,63 amps,fixed type,suitable for load line DB/LT PB connection complete of following rating :-
All as per above item but 100 amps, 25 kA
All as per above item but 125 amps, 25kA
All as per above item but 200 amps, 25kA
S&F in repairs for MCB 32 amps DP with 30 mA, 10 KA, RCBO,IP 20, Dual on position DIN clip type complete all as specified.
S&F in repairs for MCB 40 amps FP with 30 mA, 10 KA, RCBO,IP 20, Dual on position DIN clip type complete all as specified.
S&F in repars for blank plates for MCB space in any type of DBs complete
Supplying and laying in replacement or fixing or passing through pipe, 1100 volts grade PVC insulated aluminium stranded conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circuler for the following size of cables :-
(a) 6 Sqmm
(b) 10 Sqmm
S&F in repair of 3mm thick plastic laminated sheet cover with brass screws , cup wahser and cutting of grooves for switchs,scoket and regulator etc complete for following sizes.
S&F in repairs of rigid non metalic 25mm dia PVC conduit with all ftgs(tees,bends,elbows,reducers, bell mouth,saddles,pipe hooks) complete.
S&F in repairs of GI flexible conduits 25mm dia with check nut and clamps and accessories complete.
S & F LED Batten type fitting for surface/wall mounted 18 W,230V,6500K integrated electronic driver completely pre wired, LED 4 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
S & F LED Batten type fitting for surface/wall mounted 20 W,230V,6500K integrated electronic driver completely pre wired, LED 4 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
S & F LED Batten type fitting for surface/wall mounted 9W,230V,6500K integrated electronic driver completely pre wired, LED 2 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
M&L for the remove the existing 36/40W (T-8 type) tube rod and fixing the Energy efficient LED tube rod 20 W, 230V, Polycorbonate tube light, single/double side connection and necessary internally pre-wired with suitable size copper flexible wire and remove the UNSV choke and starter and including connecting up with suitable size copper flexible wire ,screws,gutties etc. complete all as specified and directed.
S&F surface mounted LED panel type 36W,230V complete with driver full window glarefree opal diffuser LED panel of size 2ftx2ft with CRCA powder coated white housing, CDL/warm type illumination complete with all accessories required for connection and making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
S&F recessed type LED panel type 36W,230V complete with driver full window glarefree opal diffuser LED panel of size 2ftx2ft, suitable for exist false ceiling with CRCA powder coated white housing CDL/Warm type illumination complete with all accessories required for connection and making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
S&F indoor decorative wall light fixture suitable for 10 W LED lamp,230V for soft light ambiance, made up of polycarbonate, spiral B22 base lamp holder used,globe shape, incl LED lamp 10W(warm/CDL type) and remove the UNSV fittings and all as specified and directed.
S&F lighting fixture wall mounted LED bulk head luminaire 10W,230V, made of die cast aluminium with opal diffuser IP 65, complete with mounting Brackets & accessories as required with connections and remove the UNSV fittings and all as specified and directed.
M&L for the remove the existing 28 W (T 5 type) tube rod and fixing the Energy efficient LED tube rod 18 W, 230V, sleek type,Polycorbonate diffuser housing,Double side connection, with LED driver out side type, incl and necessary internally pre-wired with suitable size copper flexible wire and remove the UNSV choke, and starter and including connecting up with suitable size copper flexible wire, holders, screws,gutties etc.,complete all as specified and directed.
Supply and fixing Indoor recessed/surface type mounted LED luminaires round/square type light weight plastic body downlight fitting 15 Watt, CDL/Warm type with all accessories 3 core copper wire for connection, making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
Supply and fixing Indoor recessed/surface type mounted LED luminaires round/square type light weight plastic body downlight fitting 5 Watt, CDL/Warm type with all accessories 3 core copper wire for connection, making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
S&F bldg security light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 65 protection and 25 Watt with suitabe size GI pipe bracket,clamps incl taking down old unserviceable one all specified and directed.
S&F security light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 65 protection and 45 Watt with suitabe size GI pipe bracket,clamps incl taking down old unserviceable one all specified and directed.
S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W incl fixing arrangements complete all as specified and directed.
S&F, testing and commissioning of common area lighting panel for high rise buildings, with contactor, analog time switch, MCB rating 40 A suitable for 3 Phase 415 Volts and having over and under voltage protecction relay to protect the contactor coil, with panel locking facility, wall mounted type incl necessary cable lugs, necessary copper wirinng to connect exist TPN DB with remove UNSV DB/panel complete all as specified and directed.
S&F in reapirs of garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution with tapping from nearest electrical point incl provn of copper wire, PVC conduit,necessary brick/PCC work finishing with fair cement for base fitting all as specified and directed. (Make :Crompton LBLSN 10 CDL or equivallant in Philips/Wipro)
M&L for making hole for fixing of exhaust/ventilation fan size 150 mm to 380mm with necessary civil work, alteration in exist ventilation window of iron/aluminium frame as per site requirement complete make good the wall/ventilation window match with exist complete all as specified and directed.
S&F for LED Based Outdoor Weatherproof Aviation Obstruction Lighting Luminaire 6W connections, necessary welding, clamping,mounting with 32mm dia GI pipe, 1.2 mtr height,1.5 sqmm copper wire with 20mm PVC conduit fixing on work portions upto nine storeys height bldg incl taking down UNSV complete all as specified and directed.
S&F of decorative polycarbonate gate/post top lights made up of high grade unbreakable polycarnbonate material suitable upto 20W LED lamp (B22), mounting and exist pipe with necessary fixing arrangements,fitting size in width 150/200mm, height 182/227mm incl taking dwn unsv complete all as specified and directed.
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
M&L for taking down carefully window type,Split type, Caseete type AC of capacity 1.5 Ton/2 Ton of any type/make from window/wall in various locations, removing front grills, air filters and cleaning, removing dust, washing and servicing with chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position with writing letters mentioning the MES Ser No complete all as specified and directed. (Note: Rates deemed to be included for deep cleaning/jet cleaning with pressure pump and arrest the water leakage from indoor units complete)
M&L for taking down carefully and shifting of any other location (i.e.AOR) any type of AC units complete unit of capacity 1.5 Ton/2 Ton incl making of required size core cutting hole complete all as specified and directed.
S&F in replacement of starting capacitor 80 to 100 MFD, 240 volt including making connection incl taking down UNSV complete all as directed. Make Havells/Usha/Tibcon/Epcos
S&F in replacement of running capacitor 30 to 60 MFD, 240 volt including making connection incl taking down UNSV complete all as specified and directed . Make Havells/Usha/Tibcon/Epcos
S&F in replacement of relays suitable for air conditioner of any type1.5/2 Ton incl taking down UNSV complete all as directed . Makes as per sample
S&F in repairs for overload protection coil 230 Volts for any type AC 1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed.
S&F in replacement of thermostate switch of temperature range of 18C°to 30 C° ISI marked suitable for window/split air conditioner of any make/type of capacity 1.5 Ton/2 Ton all as directed.
M&L for fan blower motor copper wound of window type air conditoner 1.5/2 Ton capacity with same rating 220/230 volts incl taking down UNSV complete. Makes as per sample
S&F for swinging/Oscillation motor with louvers(horizontal and vertical) as per existing make for any type AC 1.5 ton/2.0 ton capacity including taking out old unserviceable swinging motor ISI marked complete all as specified and directed.
S&F for fan blade for any type AC of any capacity including taking down old unserviceable fan blade all as specified and directed by Engr-in-charge.
M&L for charging/top up of refrigerant R-22 / R-410A or any other as per maufacturer recommended refrigerant gas in 1.5/2 Ton window/split Air conditioner up to required pressure including detecting leakage and rectify the leakage with proper brazing and testing on full load complete all as directed.
S&F for replacement of PVC air filter for any type AC of 1.5 ton/2.0 ton capacity including taking out old unserviceable air filter ISI marked complete all as specified and directed.
S&F in repairs suitable capacity/model condensing coil unit copper for any type AC 1.5 Ton/2 Ton capacities, ISI marked, incl taking down UNSV complete all as specified and directed by Engr-in-Charge.
S&F for replacement of capillary tube and stainer for any type AC of 1.5 ton/2.0 ton capacity incl taking down UNSV complete
M&L for replacement of copper tubing 1/4" / 3/8" / 1/2" / 5/8" dia with existing gauge for suction/discharge line of split type air conditioner of 1.5 Ton/2Ton capacity including high quality puf insulation complete all as specified.
M&L for replacement of high quality puf insulation of suitabel size of around the copper tubings complete all as specified.
S&F in repairs for PVC cable tray casing caping type (nor less than to 150 x 50 mm) including bends and other accessories as required to accommodate AC units copper tubings from indoor to out door units complete all as specified and directed.
M&L for replacement of hermatically sealed reciprocating/rotary type (as per existing) compressor unit complete for split/Window AC 1.5/2Ton with charging of refrigerant incl taking down UNSV complete (Make as per sample)
S&F in repairs for Printed Circuit Board for control unit for any type and any model of Ac 1.5 ton /2.0 ton capacity as per existing and same make ISI marked complete all as specified and directed.
S&F in replacement of front grill of window type air condition 1.5/2 Ton any make/type with LCD/LED display panel, incl taking down UNSV complete all as directed.
S&F in replacement of LCD / LED display unit for split type AC 1.5 / 2.0 ton capacity, incl taking down UNSV complete all as specified and directed.
Taking out complete unserviceable wiring for AC outdoor/indoor any type 1.0 ton/1.5 ton/2.0 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete.
S&F in repairs for 15/20 mm bore PVC flexible conduit with necessary clamping
S&F in repairs for split AC indoor unit mounting plate suitable for 1.5/2 ton capacity complete.
S&F in repairs for liquid/gas shut-off /receiver valve suitable for any type of AC s complete.
S&F in repairs for split AC out door unit mounting bracket (set of 2) suitable for 1.5/2 ton capacity complete.
S&F in repairs 6mm thick plywood sheet (ISI marked) waterproof fixed in window including cutting as desired size for fixing and covering of open space for window AC complete all as specified and directed.
M&L For Sub main wiring with 6 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn using with caping casing including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge. ( Note :-1. Extra length of cables/ wire required for connection to MCBs/DB's shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly.
S & F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps.
S & F in repair industrial type two pin and earth plug top 20 Amps complete.
M&L for removing the unserviceable Voltage Stabilizer from position ,open the outer covers , remove the burnt out winding from the transformer , rewind with super enameled copper winding wire ,insulate properly , setting / testing of buck / boost relay , replacement of U/S electronic parts , assemble back & fixing in its original position including testing for proper functioning for capacity of up to 4 KVA 1 ph , 230 V , 50 HZ complete all as specified and directed.
S&F in repairs for Volt meter single phase up to 250 Volt range
S&F in repairs for Ammeter single phase upto 40 Amps range.
S&F in repairs for over load protection relay
S&F in repairs for PCB for capacity 1 KV to 4 KV
S&F in repairs for Switch Knob for up and down
M&L for replacement of central type AC plant cooling tower FRP bottle type, capacity 7.5TR, No of cells-01, Water flow rate 100 LPM,Evaporation loss 1.7% Max, Drift loss 0.02% Max, Height approx 2000MM, Diameter approx 800MM, Pumping Head approx 180MM, Wet operating weight upto 210 KGs, fan 450mm sweep with blades (Blade and Hub material - MOC with aluminium), motor up to 2 HP, RPM 960,Frame work with MS HDG, FRP body thickness 3-4mm, distribution system sprinklers including civil works reqd at site for fixing of the cooling tower comeplete all as specified and directed.(Note: Minor spares rates deemed to be included for fixing of same)
Taking down carefully compressor unit of capacity 7.5 TR from the plant by disconnection the electric connection and rewinding of copper winding replacing piston, ring set, reed valve, gasketset, including refilling of compressor oil and after repair re-instalation the same in its original position and making necessary electric connection and testing on completion.
Repair to the AC plants central AC 7.5 TR capacity refrigerant system by cleaning and flushing the AC pipings, cooling coil, strainers, filters & liquid line etc , AHU filters by air pressure by pump and making the copmplte sytem leak proof by welding work (gas/electric welding as required by renewing gasket, 'O' ring, taflon tape etc.., as required at site, carrying out the complete pressure and vaccume test by Nitrogen Gas.
M&L for descaling the entire water circulation system including condenser but excluding mono block pump set for existing AC plants capacity 7.5 TR capacity by circulating descaling solution of standard valve with the help of descaling pump cleaning the condenser tubing with brush attached with rod including renewal of worn out gasket nuts and bolts etc
S&F in repairs for strip heaters of capacity 3 KW
S&F in repairs for humidity control device.
Supply and charging of refigerant gas R-22 to 7.5 TR capacity AC plant including testing/checking for leakage after charging.
S&F in repairs of water pressure guage 0-7 kg/Cm2.
S&F in repairs of thermostate type MP-5R suitable of 7.5 TR Central AC plant
S&F in repairs of micro processor unit suitable of 7.5 TR Central AC plant, having temp sensor, over loading sensor, under voltage sensor
S&F of expansion valve of capacity 7.5 TR for compressor cooliong system including taking out u/s expansion valve complete with testing/checking of leakage etc.
S&F in repairs for LP valve of capacity 7.5 TR by carefully openeing the unserviceable valve from the plant and testing of new valve for leakage etc.
S&F in repairs for HP vlave of capacity 7.5 TR by carefully opening the unserviceable valve from the plant and testing of new valve for leakage etc.
S&F in repairs for liquid line filter dryer.
S&F in repairs of (DOL) starter contactor kit 3 phase, 415 V suitable for 3 HP motor
M&L for dismantaling and rewinding of electric motor of capacity 3 HP, 3 phase 415 volts with super enamelled coper wire and varnishing complete, replacement of ball bearings, after refixing to its original position and testing complete
S&F in repairs AC grill 450x450mm aluminium type powder coated type proper fixing in existing position complete
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised iron wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as directed.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs.96648
Shiv Enterprises
PRASAD ELECTRICALS
M/s Adhikari construction co.
V M CONSTRUCTION
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .