| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Found lowest bidder | |
| 2 | L2₹27.5 L+₹3.9 L (16.5%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹40.6 L+₹17.0 L (71.8%)Rejected-Finance ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹42.6 L+₹19.0 L (80.6%)Rejected-Finance | L4 | Rejected-Finance 4th lowest |
| Sl No | Description | Qty | Unit | K S Enterprises L1 | AIRCOM L4 | CHOUDHARY ELECTRICAL L3 | SIYA ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Checking and attending electrical complaints for continuous electric supply like No light/short circuit / non working fittings/fixtures and replacement of unserviceable parts such as switches, sockests, fan regulator, MCBs, holders, power unit, call bell, LED driver , fan condensor any type replacement of modular plate / cover / switches including carrying out the minor repair like fixing screws tightening of loose wires any type renewal of small pieces of electtic wire upto 1.00 mtr length and maintenance work complete on all working days all as directed by Engr-in-charge, For MD Accn under AOR of AGE E/M (North) Meerut Cantt. | 4,000 | Per Complaint | 25 ₹1,00,000 | 30 ₹1,20,000 | 100 ₹4,00,000 | 21 ₹84,000 Lowest |
| 2.00 | All as described Srl item No 01 here-in-before but for OTM Accn | 1,500 | Per Complaint | 25 ₹37,500 | 30 ₹45,000 | 100 ₹1,50,000 | 21 ₹31,500 Lowest |
| 3.00 | Checking and attending electrical ceiling fan/exhaust fan complaints including replacement of UNSV ceiling fan condensor,regulator etc including for taking down & re-fixing back after repairs of any capacity complete on all working days all as directed by Engr-in-charge, For MD Accn under AOR AGE E/M No - I (North) Meerut Cantt. | 1,000 | Per Complaint | 25 ₹25,000 | 50 ₹50,000 | 120 ₹1,20,000 | 21 ₹21,000 Lowest |
| 4.00 | All as described Srl item No 03 here-in-before but for OTM Accn | 800 | Per Complaint | 25 ₹20,000 | 50 ₹40,000 | 100 ₹80,000 | 21 ₹16,800 Lowest |
| 5.00 | Attending to Geyser complaints at site including checking and rectification of any electric fault.water leakage and making good in all respects including minor repairs, replacement of unserviceable switch, socket, plug top, burnt copper wire connection wherever required complete all as specified and directed y Engineer-in-charge For MD/OTM Accn under AOR of AGE E/M - I (North)Meerut Cantt. Note for Ser item No 1,2, 3, 4 & 5 :-
(a) Flxtures/fittings shall be paid under item No. 06 to 39 as supply only.
(b) Contractors are advised to visit the sites before quoting their rates,
(c) Materials for repair works as directed by engineer -in-charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor
(d) Any nature of electrical complaint the wholesole rectification responsibility lies with the contractor.
(e) Contractor shall be penalised @ Rs 200/- per complaint per day, if he fails to attend the complaint within 12 hours.
(f) All ser numbered complaint docket will be provided by contractor and cost of docket included in these items of BOO.
(g) All T&P, safety gears & transportation shall be provided by contractor
(h) Rep of the contrractor shall receive complaints in morning 09.00 Hrs and give feedback on daily basis to concern JE E/M
(j) Payment to contractor released after submission of these compaints duly rectified. (k) The contractor shall employ 01 X Electrician for MD Accn complaints & 01 X Electrician for OTM Accn complaints. their rate quoted shall be deemed to be included for this aspect. | 200 | Per Complaint | 25 ₹5,000 | 50 ₹10,000 | 150 ₹30,000 | 21 ₹4,200 Lowest |
| 6.00 | Supply only Modular Switch, 1 module, 6A, AC, 240V, one way as per existing make and model complete all as specified and directed. | 600 | Each | 24 ₹14,400 | 70 ₹42,000 | 35 ₹21,000 | 21 ₹12,600 Lowest |
| 7.00 | Supply only Modular Switch, 1 module, 6A, AC, 240V, two way as per existing make and model complete all as specified and directed. | 100 | Each | 40 ₹4,000 | 90 ₹9,000 | 25 ₹2,500 Lowest | 31 ₹3,100 |
| 8.00 | Supply only Modular Socket, 2 module, 6A, 3 pin combined, AC, 240V, as per existing make and model complete all as specified and directed. | 250 | Each | 62 ₹15,500 | 85 ₹21,250 | 35 ₹8,750 Lowest | 41 ₹10,250 |
| 9.00 | Supply only Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, as per existing make and model complete all as specified and directed. | 150 | Each | 75 ₹11,250 | 110 ₹16,500 | 55 ₹8,250 Lowest | 75.11 ₹11,266.5 |
| 10.00 | Supply only Modular Switch, 1 module, 16A, AC, 240V, one way as per existing make and model complete all as specified and directed. | 150 | Each | 75 ₹11,250 | 110 ₹16,500 | 65 ₹9,750 Lowest | 65.11 ₹9,766.5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
2 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Meerut Cantt
GE (North) Meerut Cantt
DAILY MAINT AND RESOLVING OF COMPLAINTS OF E/M RECEIVED ON ARMAAN WEB PORTAL/COMPLAINT CELL MEERUT UNDER AGE E/M NO 1 OF GE (NORTH) MEERUT CANTT
2025_MES_704510_2
8553/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Meerut
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (North) Meerut Cantt
₹90,000
Yes
8 Aug 2025
13 Jun 2025
9 Jul 2025
13 Jun 2025
2 Jul 2025
19 Jun 2025
Amount
Checking and attending electrical complaints for continuous electric supply like No light/short circuit / non working fittings/fixtures and replacement of unserviceable parts such as switches, sockests, fan regulator, MCBs, holders, power unit, call bell, LED driver , fan condensor any type replacement of modular plate / cover / switches including carrying out the minor repair like fixing screws tightening of loose wires any type renewal of small pieces of electtic wire upto 1.00 mtr length and maintenance work complete on all working days all as directed by Engr-in-charge, For MD Accn under AOR of AGE E/M (North) Meerut Cantt.
All as described Srl item No 01 here-in-before but for OTM Accn
Checking and attending electrical ceiling fan/exhaust fan complaints including replacement of UNSV ceiling fan condensor,regulator etc including for taking down & re-fixing back after repairs of any capacity complete on all working days all as directed by Engr-in-charge, For MD Accn under AOR AGE E/M No - I (North) Meerut Cantt.
All as described Srl item No 03 here-in-before but for OTM Accn
Attending to Geyser complaints at site including checking and rectification of any electric fault.water leakage and making good in all respects including minor repairs, replacement of unserviceable switch, socket, plug top, burnt copper wire connection wherever required complete all as specified and directed y Engineer-in-charge For MD/OTM Accn under AOR of AGE E/M - I (North)Meerut Cantt. Note for Ser item No 1,2, 3, 4 & 5 :- (a) Flxtures/fittings shall be paid under item No. 06 to 39 as supply only. (b) Contractors are advised to visit the sites before quoting their rates, (c) Materials for repair works as directed by engineer -in-charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor (d) Any nature of electrical complaint the wholesole rectification responsibility lies with the contractor. (e) Contractor shall be penalised @ Rs 200/- per complaint per day, if he fails to attend the complaint within 12 hours. (f) All ser numbered complaint docket will be provided by contractor and cost of docket included in these items of BOO. (g) All T&P, safety gears & transportation shall be provided by contractor (h) Rep of the contrractor shall receive complaints in morning 09.00 Hrs and give feedback on daily basis to concern JE E/M (j) Payment to contractor released after submission of these compaints duly rectified. (k) The contractor shall employ 01 X Electrician for MD Accn complaints & 01 X Electrician for OTM Accn complaints. their rate quoted shall be deemed to be included for this aspect.
Supply only Modular Switch, 1 module, 6A, AC, 240V, one way as per existing make and model complete all as specified and directed.
Supply only Modular Switch, 1 module, 6A, AC, 240V, two way as per existing make and model complete all as specified and directed.
Supply only Modular Socket, 2 module, 6A, 3 pin combined, AC, 240V, as per existing make and model complete all as specified and directed.
Supply only Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, as per existing make and model complete all as specified and directed.
Supply only Modular Switch, 1 module, 16A, AC, 240V, one way as per existing make and model complete all as specified and directed.
Supply only Modular 5 Step Fan Regulator, 1/2 module, 100W, AC, 240V, as per existing make and model complete all as specified and directed.
Supply only modular outer plate with frame 1/2 module suitable for modular switch & board as per existing make and model complete all as specified and directed.
All as described Srl item No 12 here-in-before but 3 module
All as described Srl item No 12 here-in-before but 4 module
All as described Srl item No 12 here-in-before but 6 module
All as described Srl item No 12 here-in-before but 8 module
All as described Srl item No 12 here-in-before but 12 module
All as described Srl item No 12 here-in-before but 18 module Note for Ser item No. 06 to 18: As per existing make and model i.e. (Simon, Indo Asian, Havells, Anchor , Cona, Great white etc)
Supply only switch piano flush type, 5A, AC, 240V, one way ISI Marked complete all as specified and directed.
Supply only socket flush type, 5A, AC, 240V ISI Marked complete all as specified and directed.
Supply only switch piano flush type,15A, AC, 240V, two way ISI Marked complete all as specified and directed.
Supply only Bell Push, Flush type, 5A, AC, 240V, ISI Marked complete all as specified and directed.
Supply only socket outlet flush type, 15A, 6pin, AC, 240V ISI Marked complete all as specified and directed.
Supply only Step Fan Regulator, switch/socket type, 100W, AC, 240V, ISI Marked complete all as specified and directed..
Supply only lamp holder, angular/ straight ,PVC / Polycarbonate type with batten back plate ISI marked complete all as specified and directed.
Supply only modular Power Unit 32 A, 3/5pin, AC, 240V ISI Marked incl PVC Box complete all as specified and directed.
Supply only Ceiling rose surface Bakelite 3 terminals, AC, 240V, ISI Marked complete all as specified and directed.
Supply only Call Bell, AC, 240V, SP, ISI Marked complete all as specified and directed.
Supply only LED Driver suitable for any make or model LED street light fitting 25 to 60 Watts, 240V complete all as specified and directed.
All as described Srl item No 29 here-in-before but suitable for 2'x2' ceiling light 36/45 watts
All as described Srl item No 29 here-in-before but suitable for 12/18 Watts down lighter
Supply only 15 watt LED bulb 2 pin B22 base,100 Lumems per watt,PF≥0.9, 180° wide beam angle voltage surge protection 4kV ,6500K cool white,operating voltage 100-240V complete all specified and directed.
All as described Srl item No 32 here-in-before but 20 Watts.
All as described Srl item No 32 here-in-before but 12 Watts warm white
All as described Srl item No 32 here-in-before but 9 Watts
Supply only insulation tape roll 20 mm wide 15 Mtr long ISI mared all as directed.complete all as specified and directed.
Supply only fan Condenser 2.5 mfd 240 Volts ISI marked complete all as specified and directed Make- Havells, Tibcon, EPCOS
All as described Srl item No 37 here-in-before but 3.15 mfd Make- Havells, Tibcon, EPCOS
All as described Srl item No 37 here-in-before but 4 mfd Make- Havells, Tibcon, EPCOS
S & F in repairs anodised rust proof, GI box ,flush type of 1/2 module/3''x3'' sizes suitable for modular switches and sockets or for piano switch/ sockets etc fixed in wall including taking down existing u/s flush box making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floors / ceiling etc complete all as specified & as directed :-
All as described Srl item No 40 here-in-before but 3 module/3''x4''
All as described Srl item No 40 here-in-before but 4 module/5''x3''
All as described Srl item No 40 here-in-before but 6 module/8''x4''
All as described Srl item No 40 here-in-before but 8 module/5''x5''
All as described Srl item No 40 here-in-before but 12 module/8''x6''
All as described Srl item No 40 here-in-before but 18 module/8''x8''
S & F in repairs 3mm thick mica sheet slotted for mounting piano switch scokets any type including screw ,wahers etc of 3''x3'' size complete all as specified & as directed :-
All as described Srl item No 47 here-in-before but 3''x4''
All as described Srl item No 47 here-in-before but 5''x3''
All as described Srl item No 47 here-in-before but 8''x4''
All as described Srl item No 47 here-in-before but 5''x5''
All as described Srl item No 47 here-in-before but 8''x6''
All as described Srl item No 47 here-in-before but 8''x8''
S & F in repairs 36W LED recessed mounted 2'X2' panel light having CRCA sheet housing, PC diffuser, luminous efficacy of 100 lumen/W, CRI > 80, PF ≥ 0.9, CCT 6500K/3000K, independent isolated SMPS based constant current electronic LED driver with THD < 20%,built-in surge voltage protection min 2.5kV and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, IP 20 protection, input voltage range 140- 270V , input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed
S & F in repairs 20 W surface / wall mounted, 4 feet LED tube light luminous efficacy of ≥100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, including electrical connection with 3 core flexible Cu conductor cable from ceiling rose to the fixture complete all as specified and directed
S & F in repairs Wall mounting focus light with polycarbonate diffuser prewired incl 14/15 Watts LED lamp complete all as specified and directed.
S & F Wall mounting fancy / round light fitting with polycarbonate diffuser prewired incl 9 Watts LED lamp complete all as specified and directed.
S & F in repairs 12/15W LED bulkhead light outdoor IP 65 fitting with polycarbonate diffuser 1 complete all as specified and directed.
S & F in repairs fancy mirror light with polycarbonate diffuser prewired incl 14/15 Watts LED lamp complete all as specified and directed.
S & F decorative wall light fixture made up of polycarbonate suitable for retrofit LED 4 to 9 watts lamp including all accessories for fixing of fitting on wll all as specified and directed
S & F in repairs pressure die-cast alluminium housing 18 Watt LED flush / surface/reccesd mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed..
S & F in repairs pressure die-cast alluminium housing 12 Watt LED flush / surface/reccesd mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed..
S & F 10 W surface / wall mounted, 2 feet LED tube luminous efficacy of ≥100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K including electrical connection with 3 core flexible Cu conductor cable from ceiling rose to the fixture complete all as specified and directed
S & F in repairs 25 Watt pewired pressure die cast housing LED bldg security light luminaire IP 66 ingress protection ,Efficacy 100lm/watt ,built-in surge protection,electronic driver incl suitable OD GI pipe bracket, mounting clamps with nuts, bolts and washers, electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete all as specified and directed
All as described Srl item No 64 here-in-before but 35/45 Watts.
S & F 50 Watt pewired pressure die cast LED flood light luminaire IP 66 Efficacy 100lm/watt incl suitable OD GI bracket, two nos mounting clamps with nuts, bolts and washers complete all as specified and directed.
S & F sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 ,IK08 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as directed .
All as described Srl item No 67 here-in-before but 06 way
All as described Srl item No 67 here-in-before but 08 way
All as described Srl item No 67 here-in-before but 10 way
All as described Srl item No 67 here-in-before but 12 way
S & F sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 08 protection including provision for four pole isolator/MCB as incomer with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as specified and directed.
S & F VTPN DB double door, (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB suitable up to 250 Amps, 25 KA of frame 2 as incomer and 12 Nos MCB'S inside of DB, with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing one taking down the old distribution board of any type complete all as specified and directed
S & F in repairs MCB SP 6 to 32 A, AC, 240V, 10KA, ISI Marked complete all as specified and directed.
S & F in repairs Isolator DP, 40A, AC, 240V, ISI/CE Marked conforming to IEC 60947-3,biconnect terminals complete all as specified and directed.
All as described Srl item No 75 here-in-before but 63A
S & F in repairs Isolator 4P, 63A, AC, 415V, ISI/CE Marked complete all as specified and directed.
All as described Srl item No 77 here-in-before but 100A
All as described Srl item No 77 here-in-before but 125A
S & F in repairs 1 module SPN metallic enclosure with a two pin and earth plug and socket with one MCB SP 20 Amps complete all as specified and directed.
S&F in repairs 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16KA with Ics=100%Icu, adjustable overload setting as per existing make and model complete all as specified and directed.
All as described Srl item No 81 here-in-before but 100Amps 16KA
All as described Srl item No 81 here-in-before but 125Amps 16KA
All as described Srl item No 81 here-in-before but 160Amps 16KA
All as described Srl item No 81 here-in-before but 200Amps 16KA
All as described Srl item No 81 here-in-before but 250Amps 16KA
S & F in repairs PVC casing and caping of size 20 to 32 mm ISI maked all as directed.
S & F in repairs1100V grade PVC sheathed flexible two core cable with multistranded copper conductor of size 1.5Sqmm, ISI Marked complete all as specified and directed
S&F in repairs copper cable 1.5 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed
S&F in repairs copper cable 2.5 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed
S&F in repairs copper cable 4 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed
S&F in repairs copper cable 6 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed.
S&F in repairs 1100 volts grade heavy duty PVC sheathed stranded Aluminium conductor twin core cable flat or circular of size 10 Sqmm complete all as specified and directed
M & L for rewinding including taking down and refixing the fans of any make, any model, from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc, replacement of body screws,bearing,bush and other accessories as required etc and testing, commissioning on full load for 4 hrs continuous running all as directed for Ceiling Fan 1200mm Sweep of any make or model complete all as specified and directed
S&F in repairs BLDC ceiling fan 1200mm sweep BEE 5 star energy rated with remote minimum service value≥6,copper winded motor with electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete incl taking down old u/s one and depositing to MES Store yard all as specified and directed
S&F in repairs PVC exhaust fan, 200mm sweep with lovers, AC, 230V incl taking down old u/s one complete all as specified and directed
S&F in repairs PVC exhaust fan, 250mm sweep with lovers, AC, 230V incl taking down old u/s one complete all as specified and directed
All as described Srl item No 97 here-in-before but metal body sweep 300mm.
All as described Srl item No 97 here-in-before but metal body sweep 450mm.
All as described Srl item No 97 here-in-before but Wall fan PVC type body 450mm sweep.
SIYA ASSOCIATES (BID ID -3344494)
CHOUDHARY ELECTRICAL (BID ID -3336941)
AIRCOM (BID ID -3343160)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .