| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | ₹36.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹39.3 LRejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹39.3 L | L2 | Rejected-AOC other than Lowest Bidder |
| Sl No | Description | Qty | Unit | M/s badrinath Traders L2 | naina devi constructions L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth and forming bottom surfaces to the required gradient and slope for laying of cable, pole etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. | 902 | Cum | 150 ₹1.4 L | 150 ₹1.4 L |
| 2.00 | Returning, filling, in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, all as specified. | 689 | Cum | 50 ₹34,450 | 4 ₹2,756 |
| 3.00 | Removing excavated surplus (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. | 163 | Cum | 50 ₹8,150 | 90 ₹14,670 |
| 4.00 | M&L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed by Engr-in-Charge | 10,600 | Each | 5 ₹53,000 | 5 ₹53,000 |
| 5.00 | Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured | 129 | Cum | 400 ₹51,600 | 700 ₹90,300 |
| 6.00 | Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 90 mm outer dia and 76 mm inner dia all as directed. | 84 | Rm | 150 ₹12,600 | 140 ₹11,760 |
| 7.00 | All as per item 06 above but of size 77 mm outer dia and 63 mm inner dia all as directed. | 90 | Rm | 120 ₹10,800 | 140 ₹12,600 |
| 8.00 | All as per item 06 above but of size 63 mm outer dia and 50 mm inner dia all as directed. | 90 | Rm | 100 ₹9,000 | 90 ₹8,100 |
| 9.00 | Supply, laying ,jointing and testing LT XLPE insulated cable screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of cross-sectional area 6 Sqmm, 4 core making all incoming and out going connections through the lugs/thimbles after taking out of old unservicable under ground cable from trenches/road/alongwalls/ pipe/ poles complete all as specified and directed . Note :- Excavation & earth work shall be measured & paid separately under respective item of this schedule | 100 | Rm | 100 ₹10,000 | 120 ₹12,000 |
| 10.00 | All as per item 09 above but size 10 sq mm 4 core | 400 | Rm | 150 ₹60,000 | 138 ₹55,200 |
Tender Value
₹40.1 L
EMD Value
₹80,256
Closing Date
25 Sept 2025, 6:00 pmClosed
GE CHANDIGARH
GE CHANDIGARH, N Area, Pin-160003
REPAIR AND MAINTENANCE OF ELECTRICAL SUPPLY LT PANELS, MCCB, CABLES AND CONNECTED WORKS AND REPAIR/ MAINTENANCE OF GI PIPE LINE, ALL KIND OF MOTORS INCLUDING ALL ACCESSORIES HELD AT MIL STN NAHAN UNDER GE CHANDIGARH.
2025_MES_728501_1
GE/CHD/T-60/2025-26
Open Tender
Electrical and Maintenance Works
270 days
Nahan Under GE Chandigarh
Class D category a(ii) and b(i) for contractor enlisted in MES
8 documents required · 8 mandatory
₹500
GE CHANDIGARH
₹80,256
Yes
16 Dec 2025
30 Aug 2025
27 Sept 2025
30 Aug 2025
25 Sept 2025
13 Sept 2025
30 Aug 2025 - 7 Sept 2025
Amount
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth and forming bottom surfaces to the required gradient and slope for laying of cable, pole etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling, in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, all as specified.
Removing excavated surplus (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
M&L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed by Engr-in-Charge
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 90 mm outer dia and 76 mm inner dia all as directed.
All as per item 06 above but of size 77 mm outer dia and 63 mm inner dia all as directed.
All as per item 06 above but of size 63 mm outer dia and 50 mm inner dia all as directed.
Supply, laying ,jointing and testing LT XLPE insulated cable screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of cross-sectional area 6 Sqmm, 4 core making all incoming and out going connections through the lugs/thimbles after taking out of old unservicable under ground cable from trenches/road/alongwalls/ pipe/ poles complete all as specified and directed . Note :- Excavation & earth work shall be measured & paid separately under respective item of this schedule
All as per item 09 above but size 10 sq mm 4 core
All as per item 09 above but size 16 sq mm 4 core
All as per item 09 above but size 25 sq mm 4 core
All as per item 09 above but size 35 sq mm 4 core
All as per item 09 above but size 185 sq mm 4 core
Supply and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminiumconductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 4 core complete all as directed.
All as per item No 15 above but 16 sqmm 4 core omplete all as directed
All as per item No 15 above but 4 sqmm 4 core omplete all as directed
M&L for Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers and earth lead protected by 15mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete earthing, specified in SSR part-II.
Supply & fixing in replacement of Busbar chamber comprising 6 way of 3 Aluminum strips 200 Amp & one copper strip of capacity 200 Amps and minimum length 460mm long enclosed in sheet metal enclosure including all the fixing arrangements, making all incoming and out going connections through the lugs/thimbles all as specified and directed.
Material and Labour for Aluminium thimbles/lugs for connections of size 50 Sqmm under ground heavy duty cable all as specified and directed.
All as per item No.20 above but of size 70 Sqmm
All as per item No.20 above but of size 95 Sqmm
All as per item No.20 above but of size 120 Sqmm
Supply and fixing in replacement of Steel tubular swaged poles type 410 SP-22 (8.5. meter long) complete with cast iron base plate, finial taper plug, bolts, nuts & screws etc including making the holes on the pole (bottom and top) suitable size for drawing of wire 6 sqmm 3 core round flexible for connection of security light fitting from junction box to light fittings including of one primer coat, one under coat and one finishing coat of silver paint including dismantling existing PCC pole complete all as specified and directed.
Meterial and labour for cement concrete in foundations for pole coping or any other work type B0 1:2:4 with 12.5mm graded crushed stone aggregate all as directed.
Meterial and labour for cement concrete in foundations for pole or any other work type C2 1:3:6 with 40 mm graded crushed stone aggregate all as directed.
Meterial and labour for cement concrete in foundations for pole or any other work type D2 1:4:8 with 40 mm graded crushed stone aggregate all as directed.
Supply and fixing of Junction box made out of thermo plastic material of size 240x130x110 mm with provision of single phase cable connector incomming and out going with MCB SP 6-32 amps for security light fitting/PTL IP 54 protection totally enclosed weather proof with cable entry along with GI clamps nut bolts & washer fixed on pole including dismantling/taking out old unserviceale one all as directed.
Supply and fix in replacement of security light fitting bracket made up of 25/32 mm dia medium grade pipe of length 0.9 mtr with bending in shape by hot or cold method with 2 nos 50x4 mm MS flate clamps with nut bolts and washer etc all as directed.
M&L for preparation & Painting existing panel surfaces with two coats of synthetic enamel paint over a coat of red oxide primers for surfaces exc 10 cm width or grith complete all as specified and directed.
Repair and replacement of Existing broken doors, injes , voltmeter, ampiermeter with CT , insullator, thimmer of existing size, Aluminium/Copper lead, switches, locks , therminal , Bus bar etc complete all as specified and directed.
S & F of LED street light fitting 60 Watt,230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection pf 0.90, luminious efficiency lm 110/watts, 5700k complete including taking down old unsv fittings of any size / watt complete all as specified and directed.
Supply and Filling Transformer Oil A high-grade insulating oil used in transformers for cooling and insulation complete all as specified and directed
Supply and fixing of End termination kit for 1.1 Kv grade of exixting size UG cable at site with 3.5 Core complete along withjointing material all as sepecified and as directed .
Supply , Installing ,testing and commissioning, weather,vermin proof LT Feeder pillar box of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement and angle iron legs made out of 50mmx50mmx 6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with and constitute the following -
Taking up or down old unserviceable corroded existing 25 mm bore steel water tubing & connections including all fittings and fixtures, laid in trenches or fixed along the walls or in any position, complete all as specified and as directed .
All as per item No 37 above but 40 mm bore.
All as per item No 37 above but 50 mm bore.
All as per item No 37 above but 80 mm bore.
Supply, laying, connecting & testing of 25 mm bore steel water tubing galvanized medium grade, with all fittings & fixtures (ISI marked) Such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, and unions etc) and fixing complete with clips wall hooks, wooden plugs or laid in trenches or fixed along walls or in any position complete all as specified and as directed .
All as per item No 41 above but 40 mm bore.
All as per item No 41 above but 50 mm bore.
All as per item No 41 above but 80 mm bore.
S&F gun metal gate or globe valves heavy duty yoke type, full way openig with iron wheel head screwed with both end of GI tubing 50 mm bore ISI marked including taking down of unserviceable gate or globe valve all as specified and directed.
All as per item No 45 above but 40 mm bore.
All as per item No 45 above but 25 mm bore.
All as per item No 45 above but 20 mm bore.
All as per item No 45 above but 15 mm bore.
S&F of HDPE Hose pipe 4 inch canvas hoses with inside rubber /PVC lining suitable for water delevirey including coupling male & female for both side and jointing coupling also and all as specified and directed.
General servicing of DG set of capacity 125 KVA (make: Kirloskar) from authorized dealer including cleaning of machines, fuel tank etc checking of oil levels, filters, fan belts, hose pipe, proper adjustment of tappet, checking of governor assembly, radiator complete all as per manufacturers recommendations including replacement of Fuel filter, Engine oil filters, etc complete as per direction of Engr-in-Charge. Note :- Engine oil & Coolant wii be measured and paid separately under subsequent items
All as per item No 51 above but 15 KVA (make: Kirloskar)
All as per item No 51 above but 20 KVA (make: Kirloskar)
Repairs to DG set engine of capacity 125KVA of any make, 6 cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction and testing of efficiency of engine on completion complete all as directed. (worn out / unserviceable parts shall be measured and paid seperately) Note : Repairs to be done from Authorized Dealer
Piston assy as per existing model complete all as directed
Ring set as per existing model complete all as directed.
Cylinder liner as per existing model complete all as directed
Set of liner 'O' ring as per existing model complete all as directed
Gasket set kit as per existing model complete all as directed
Coupling as per existing model complete all as directed
Gasket (Main Seal) as per existing model complete all as directed
Diesel Pipe Set as per existing model complete all as directed
Hose Pipe as per existing model complete all as directed
Hose Clamp as per existing model complete all as directed
Cylinder head gasket as per existing model complete all as directed
Cylinder head 'O' Ring as per existing model complete all as directed
Valve set as per existing model complete all as directed
Valve seal as per existing model complete all as directed
Valve guide as per existing model complete all as directed
Connecting rod bearing as per existing model complete all as directed
Connecting rod bush as per existing model complete all as directed
Fan Belt as per existing model & size complete all as directed
Repairs to DG set engine of capacity 15 / 20 KVA of any make, 4 cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction and testing of efficiency of engine on completion complete all as directed. (worn out / unserviceable parts shall be measured and paid seperately) Note : Repairs to be done from Authorized Dealer
Piston assy as per existing model complete all as directed
Ring set as per existing model complete all as directed.
Cylinder liner as per existing model complete all as directed
Set of liner 'O' ring as per existing model complete all as directed
Gasket set kit as per existing model complete all as directed
Coupling as per existing model complete all as directed
Gasket (Main Seal) as per existing model complete all as directed
Diesel Pipe Set as per existing model complete all as directed
Hose Pipe as per existing model complete all as directed
Hose Clamp as per existing model complete all as directed
Cylinder head gasket as per existing model complete all as directed
Cylinder head 'O' Ring as per existing model complete all as directed
Valve set as per existing model complete all as directed
Valve seal as per existing model complete all as directed
Valve guide as per existing model complete all as directed
Connecting rod bearing as per existing model complete all as directed
Connecting rod bush as per existing model complete all as directed
Fan Belt as per existing model & size complete all as directed
Taking out Fuel injection pump from DG set, transportation to authorized service centre for overhauling and re-caliberation and re-fixing to DG set complete all as specified and directed of capacity DG Set 125 KVA. Make - Kirloskar complete all as directed:- Note: (a) unserviceable / defective parts shall be measured and paid seperately (b) Repairs to be done from Authorized Dealer
Injector as per existing model complete all as directed
Injector Nozzle as per existing model complete all as directed
Delivery valve as per existing model complete all as directed
FIP Element as per existing model complete all as directed
Gevernor as per existing model complete all as directed
Taking out Fuel injection pump from DG set, transportation to authorized service centre for overhauling and re-caliberation and re-fixing to DG set complete all as specified and directed of capacity DG Set 15 & 20 KVA. Make - Kirloskar complete all as directed:- Note: (a) unserviceable / defective parts shall be measured and paid seperately (b) Repairs to be done from Authorized Dealer
Injector as per existing model complete all as directed
Injector Nozzle as per existing model complete all as directed
Delivery valve as per existing model complete all as directed
FIP Element as per existing model complete all as directed
Gevernor as per existing model complete all as directed
Replacement of defective / unserviceable automatic voltage regulator (AVR) suitable for 15 to 20 KVA DG Set complete all as directed. Make - Kirloskar/CG/Mahindra & Mahindra
Replacement of defective / unserviceable Alternator / Dynamo 12 volt 15 to 20 KVA DG Set, as per existing model complete all as directed
Cleaning of radiator with the help of descaling agent/solution including repairs to the broken tubes and replacement of wornout rubber hoses for 15 to 63 KVA DG Set complete all as directed
Replacement of defective / unserviceable Air Filter for 125KVA capacity DG set of any make complete all as specified and directed
All as per item No 107 above but for 15/20KVA capacity DG set of any and model
Replacement of defective / unserviceable Engine Oil 20 W 40 or equivalent grade suitable for DG set at various locations. Make: Castrol/ Servo/HP
Supply and filling concentrated coolant for radiator in 5 litre capacity container complete all as directed.
S&F the battery of 12 V 180 AH suitable for DG set complete all as directed. Make : Exide/ Amaron/Amco/Sukam
Replacement of defective / unserviceable battery lead of copper conductor 35 sqmm, 3 mtr length, single core fitted with lead terminal on one side and other side with brass or lead terminal as per requirement and connection as directed
supply and fix electrical battery charger 24 volt 10 Amp complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32x6mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 5 all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe ,medium grade 40mm and GI watering pipe 20mm ,medium grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed.
Dismantling opening and overhauling of pump set multi stage capacity 10000 GPH at Stage -I, head 600/1200 feet from site to workshop including repair/replacement of parts listed below reassembling the pump commissioning and testing after repairs including necessary welding work, gasket, packing, nuts bolts and washers atc complete all as pecified and directed:-
(a) Shaft weld & machinerry (b) New Empeller- 11 Nos (c) New Difuser - 6 Nos (d) New CI Cashing Necking - 11 Nos (e) New CI Con Bush - 10 NOs (f) Section body reapair (g) Keys - 14 Nos (h) New Sleev - 2 Nos (i) Adjusted pices - 4 Nos (k) Big size rubber ring - 11 Nos (m) Sleeve rubber ring _ 2 Nos (n) Boll bearing No 308 - 1 Nos (p) Boll bearing 7308 _ 2 Nos (q) Boll bearing adjusted piece - 4 Nos (r) Jain dowery with greasing (s)Jain dowery stud- 4 Nos (t) Jain pecking , Neck bush GM - 06 Nos, Impeller GM - 05 Nos , Neck ring GM - 04 Nos , Diffuser CI - 03 Nos, Shaft Key - 06 Nos , Shaft Sleeve - 02 Nos Balancing Disk SS - 02 Nos, balancing bush,bearing and packing glands as per existing size including disconnecting and removing from existing foundation of pumping set 100 HP,3 phase,50 Hz incl mortar at stage-I and refixing at existing foundation incl testing complete after repair. Note:The cost of loading, unloading including transportation for carrying of this item from site to workshop and back shall to be included in the unit rate of this item.
Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 2,70,786.00 shall be deducted from the total amount arrived.
Total of Schedule 'A' Rs.
M/s badrinath Traders (BID ID -3426843)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid