| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | ₹40.1 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹40.1 LSame as L1Rejected-AOC | ₹40.1 LSame as L1 | L2 | Rejected-AOC Not L1 Bidder |
| 3 | L3₹42.4 L+₹2.3 L (5.63%)Rejected-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹42.4 L+₹2.3 L (5.63%) | L3 | Rejected-AOC Not L1 Bidder |
| 4 | L4₹43.0 L+₹2.8 L (7.03%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹43.0 L+₹2.8 L (7.03%) | L4 | Rejected-AOC Not L1 Bidder |
| 5 | L5₹44.5 L+₹4.4 L (10.9%)Rejected-AOC | ₹44.5 L+₹4.4 L (10.9%) | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹43.7 L
EMD Value
₹87,360
Closing Date
1 Oct 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT10
GE U WATER SUPPLY DELHI CANTT10
SPL REPAIRS TO WATER SUPPLY PIPE LINE IN DEFENCE OFFICER ENCLAVE DHAULA KUAN PART I DK I OF AGE U WATER SUPPLY NO II UNDER GE U WATER SUPPLY DELHI CANTT10
2024_MES_669929_1
GE/WS/Token-09 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT10
₹87,360
Yes
5 Dec 2024
2 Sept 2024
3 Oct 2024
2 Sept 2024
1 Oct 2024
17 Sept 2024
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 metre depth and getting out in any type of soil for taking out/laying pipes complete all as specified and as directed
Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed
Removal of excavated material (soils) from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point as directed by Engr-in-Charge.
M&L for boring holes under road pavement by bocky manually/mechanically in any type of soil upto 200 mm bore below GL upto required depth complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable DI/CI pipe, joints, bends, elbow, tees, rubber joints of size upto 200mm dia complete all as specified and directed by Engr-in-Charge. (Note:- (i) Excavation and earth work will be measured and paid seperately under respective items. (ii) Old U/s material CI/DI pipe & with fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ. Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates. Note3:- DI pipe whole quantity of tender shall be procured by contractor in one time and submit PV's MTC & e-way for whole quantity of DI pipe alongwith 1st RAR for payment material laying at site. Note4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly. Note5:- Rubber fibre (Tyton) Joints shall be deemed included in quoted unit rate. Note6:- Layout plan for laying of DI pipe shall be given by EIC in writing.
100 mm dia
150 mm dia
200 mm dia
M&L DI fittings/specials in replacement such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 9523 complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s material DI fittings obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Upto 200 mm bore
M&L run lead joint including jointing material for cast iron spigot & socketed pipe using lead bar & spun yarn of best quality of following size/bore :-
100 mm bore
150 mm bore
200 mm bore
Taking down old unserviceable MS pipe, joints, bends, elbow, tees, rubber joints, elbow upto 150 mm dia complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s material MS Pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supplying , laying , jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, 4mm thick, 150mm bore dia laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections to centrifugal pump set for suction, pump to header and connected to out going water main CI/DI pipe line complete all as directed by Engineer-in-charge. (Note:- MS Flanges shall be measured and paid separately.)
Supplying and fixing MS flanges of 150 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed by Engr-in-Charge.
Supply, fixing, jointing & testing of cast iron sluice valves class PN-1.6, conforming to IS:14846 flanged ends drilled having stainless steel spindle with cast iron operation wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified and directed. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material sluice valve obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (EACH) shall be taken into account and attach with RAR/F Bill)
100 mm bore
150 mm bore
Supply and Fixing in replacement of CI Foot valve rating PN 0.2 flanged ends, swing type opration with rubber sheet of size 150mm bore dia as per IS-4038 including taking out unserviceable complete all as specified and directed by Engineer-in-Charge. Note (i) :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items. (ii) Old unserviceable foot valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unserviceable water meter complete all as specified and directed at site by the Engr-in-Charge. (Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old unserviceable water meter shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm bore
150 mm bore
Supply & fixing Gun metal gate valve with iron wheel head screwed both iron iron pipe ISI Marked as per IS 778 of following sizes including taking out unserviceable gate valve complete all as specified and directed :- (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of gun metal gate valve in weight (KG) shall be taken into account and attach with RAR/F Bill)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
M&L water pressure gauge (0-5 Kg/cm square) 100mm dial size including boring, threading, welding in CI/DI/GI of any sizes and connected with suitable size of U type MS/CP pipe with ON OFF cock complete all as specified and directed.
M&L PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site all as specified and as directed at site by the Engr-in-Charge. (Note:- Old U/s material brick/brick bats obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (CUM) shall be taken into account and attach with RAR/F Bill)
M&L rendering 10 mm thick with cement mortar (1:6) on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and directed by Engr-in-Charge.
Taking down old unsv GI pipe including joints, bends, elbow, tees, rubber joints of size upto 50 mm dia complete all as specified and directed by Engr-in-Charge.
M&L GI tubing 'medium grade' with all accessories including bends, elbow, Tee, socket, union, nipple etc laid over wall / floor / trenches including taking up or down old unserviceable GI tubing complete all as specified and directed. (Note:- Old U/s GI tubing & fittings obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F fabrication, welding and fixing of MS frames made out of MS angle/ flat of any size as required at site for repair/replacement of Sump manhole cover, cesspit (Haudi) cover, Stair case steps and all other iron works including covering top with MS Sheet of suitable size and welding with the frame complete all as specified and directed. (Note:- Old U/s MS frame obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply, installation and testing flanged ends strainer/dirt box of 150 mm bore sizes PN-10 with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out old unserviceable strainer/ dirt box complete all as directed at site by the Engr-in-Charge. (Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material strainer / dirt box obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Labour for Cutting RCC/PCC/Road/Brick Wall in the Position for Insertion of new pipe of Size upto 200 mm Bore Including making good surface as Before Complete all as Specified and Directed by Engr-in-Charge. (Note: Old unserviceable material retrieved from above subject CA will be taken on ledger Charge).
B.R. Enterprises (BID ID -3101069)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3098454)
P S TRADERS (BID ID -3106550)
ENVIRO TECH SERVICES (BID ID -3109931)
Microsys Automation India (BID ID -3121496)
Ridhi engineers and builders (BID ID -3111865)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .