Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.7 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400708 | L1 | Accepted-AOC Being lowest bid | |
| 2 | L2₹94.4 L+₹9.7 L (11.5%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹1.2 Cr+₹39.2 L (46.2%)Rejected-Finance 00 BHADAR TIKARMAFI BAZAR SULTANPUR UTTAR PRADESH 227413 | AMETHI | UTTAR PRADESH | 227413 | L3 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL Vikas Kesarwani
HQ CWE AF Lohegaon
WORK SERVICES TO STRUCTURAL SAFETY OF 121 HF HANGAR AND ADDITIONAL ALTERNATION TO ANNEX BUILDING
2022_MES_526963_2
82621
Open Tender
Civil Works
Item Rate
270 days
GE AF Thane
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE AF Thane
₹1.6 L
Yes
29 Aug 2022
29 Jun 2022
3 Aug 2022
29 Jun 2022
27 Jul 2022
5 Jul 2022
Amount
M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members to the following complete all as per manufacturer instruction and directed by Engr-in- Charge:- (i) Cleaning existing surfaces of RCC members and making surfaces free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting etc. (ii) Further, cleaning using biocide to ensure that surface is free of algae and fungus and no trace of paint left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Roller / brush application of water based acrylic primer @ 10 Sqm/ ltr over dry and cleaned surface. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 2.2 Sqm per ltr. (vi) Apply second coat of Aliphatic Acrylic anti-carbonation (ACC) @ 2.2 sqm per ltr after 5-6 hours.
M & L for Removal of existing concrete including loose/weak concrete from the concrete structure ie. beams/columns/deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge including steel frame double scaffolding Complete all as specified and directed by Engr-in- Charge
Preparation of surfaces and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16-24 hrs and applying two coats of Epoxy phenolic anti corrosive protective paint over a coat of alkaline rust converting primer around bars old & new as per manufacturers instructions. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth including necessary scaffolding complete all as per manufacturer instructions and directed by Engr- in- Charge.
M&L 50mm thick ( average thickness) polymer modified single component alkaline resistant fibre reinforced, cementitious patch repair mortar on conrete structure. Applying the mortar around the reinforcement and finishing to bring it in line with existing concrete surface including necessary scaffolding with preparation of concrete surfaces by removing loose concrete dust, dirt etc. Cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application to parent concrete complete all as per manufacturer instructions and directed by the Engr-in- Charge. Cured mortar should exhibit compressive strength of 20 MPa after 1 day and atleast 45 MPa after 28 days, tensile strength atleast 2.5 MPa after 28 days and flexural strength atleast 7 MPa after 28 days.
M&L for treatement of cracks in core concrete as follows :- (i) Opening of crack by making a ' V' notch/groove of size 12mm x 12mm over the entire length of the crack as identified by the Engr-in-charge. (ii) cleaning ' v' notch/groove of all dust/debris/loose material (iii) Drilling hole of 16mm dia and about 40mm deep along the length of crack @ (300 mm c/c or thickness of structural member whichever is less) Note : In case length of crack is found less than 300 mm then min 2 holes shall be drilled. (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole drilled above and fixing the nipple with the help of fast setting epoxy putty. (v) seal the surface around the nipple and the area of crack between successive nipples polymer modified mortar to ensure (viii) Injecting " resin with very low viscosity monomer by mixing resin and hardener in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air & resin.
M&L for treatement of porous/honeycombed core concrete as follows :- (i) Marking the area in marker as directed by the Engr-in-charge. (ii) Drilling holes of 16mm dia in an orthogonal grid on exposed core of member @ 150 mm c/c both way, depth of the hole shall be about 60% of the element thickness. (iii) clean the drill hole using compressed air removing the dust/dirt. (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole with the annular space around the nipple sealed with epoxy putty. It shall be ensured that the injected grount does not leak. (v) Allow the nipple to cure for 24 hours. (vi) Injecting Resin with very low viscosity monomer by mixing resin and hardener in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air & resin. Note : pressure shall be in the range of 2-3 kg/sqm and shall be done in nipples one by one as per order recommended by manufacturer. Mixing of resin and hardenere shall be mixed in small quantities so as it is consumed with in 30 minutes. Before use mixer shall be stirred thoroughly.
M & L for 12mm dia steel shear connector in grid pattern in between old core and new concrete including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar complete all as specified and directed by Engr-in- Charge.
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low pemeable 'free flow ' non shrink ' self compacting micro concrete shall be grade M 40 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr-in- Charge. The rate shall include the cost of following: (i) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (ii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength.
M&L for Drilling & chemical anchoring of new rebars 8mm dia, 384 Nos and 80 to 100 mm long as under :- (i) Drilling in to the sound RCC members for anchoring of rebars depth 80mm to 100mm. (ii) Placing/anchoring 384 Nos 8mm dia bars at a required specing using epoxy resin anchoring mortar of approved brand. Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is included in this item)
M&L for Drilling & chemical anchoring of new rebars/stirrups as under :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 16 & 20 mm dia bar - drilling length 160 to 180 mm - 336 Nos at a required spacing Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
M&L for strengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed including steel frame height of single scaffolding Complete all as specified and directed by Engr-in- Charge
M&L for Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement Complete all as specified and directed by Engr-in- Charge. Note:- (Dismantling and reconstruction of of brickwork, if required, shall be paid separately).
M&L for fixing of Hessian cloth,plywood to cover the windows including Bamboo scaffolding etc complete all as specified and directed by the Engr-in-Charge.
M&L for rendering 20mm thick in two layers on external surfaces first layer 15mm thick in CM 1:6 on fair faces of brick/PCC block or concrete surfaces and second layer ( setting coat / finishing) 5mm thick in CM 1:4 with approved water proofing liquid compound finished even and smooth without using extra cement including racking out joints, hacking for key of concrete surface, finishing, curing, scaffolding etc complete all as specified and directed by Engr-in- Charge. (Note:- WPC shall be measured and paid seperately)
M&L for rendering 12 mm thick ready mix internal plaster in single coat at any positions of surface including racking out joints, hacking for key of concrete surface, finishing, curing, scaffolding etc complete all as specified and directed by Engr-in- Charge.
Material & labour for applying two coats of premium exterior acrylic emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre / 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre /10 Sqm over new surface complete all as specified and directed by Engr-in- CHarge.
M&L for applying 3mm thick wall care putty on walls including preparation of new or previously untreated surfaces complete all as specified and directed by Engr-in- Charge.
M&L for applying two coats of oil bound distemper over a coat of primer on walls including preparation of new or previously untreated surfaces complete all as specified and directed by Engr-in- Charge.
M&L Demolition of cement concrete of any description and in any position not otherwise specifically provided for, as in hangar floor etc complete all as specified and as directed by Engr-in- Charge.
M&L Removing demolished material/ debries to a distance exceeding 13.50 KM but not.exc 15 KM and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in- Charge.
M&L for cement concrete type B0, 1:2:4 using 12.50mm graded aggregate as in roof kerb or mud stop, rounded or charmfered edges , lintels upto 1.50m over 1.5m span cills, steps, seismic and other similar bands, plinth courses, parapet walls and railing upto 0.60m height, coping, kneelers,apex stones complete all as specified and directed by Engr-in-Charge.
M & L for providing, cement concrete type B0 1:2:4 (12.50 mm graded aggregate) mixed with water proofing compound @ 3% by weight of cement in roof kerbs or mud stops, rounded or camferedon edges all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in chajjas or similar works complete all as specified and directed by Engineer -in- Charge.
M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate for beams , cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed by Engineer -in- Charge.
M&L for form work to sides and soffits of floor or roof beams , beam haunchings including supports overhang etc also splays between floors and beams etc on rough finish surfaces complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate for columns, , pillars, piers, posts and sturts complete all as specified and directed by Engineer -in- Charge.
M&L for form work to sides of pillars, posts, columns, piers and stanchions in square, rectangular fair finished surface of concrete etc complete all as specified and directed by Engr-in-Charge.
M & L for MS TMT bars 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders or securing with clips etc complete all as specified and directed by Engineer in charge.
M & L for MS TMT bars 10mm dia and over as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer in charge.
Cutting holes into or throuhg brick wall built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 not exceeding 150 Sq CM complete all as specified and as directed by Engr-in- Charge.
Dismantling of wall and ceiling board ( fibre, pulp, insulation etc) as in ceiling and lining of any gauge or any thickness including cover fillets complete all as specified and directed by Engineer in charge.
S &F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per manufactur specification complete all as specified and as directed by Engr-in- Charge.
S & F solid PVC wall lining consisting of 5mm thick plain colour PVC sheet in ceiling inclusive of solvent cement and fixing on PVC frame as per manufactur specification complete all as specified and as directed by Engr-in- Charge.
S & F in repairs for aluminium anodised snap grid frame work for suspended false ceiling size 605 x 605mm with 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet in ceiling fixed with screws including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete as per manufacturer instructions complete all as specified and directed by Engineer in charge.
S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work to timber/rubber beading to Aluminium framework in Partition or Wall Panelling complete all as specified and as directed by Engr-in- Charge.
M&L Demolition of Stone slabs and tiles laid, bedded, pointed in ay mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer in charge.
M&L for 20 mm thick Granite (of any colour) tiles on floors machine cut, bedded and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed by Engr-in- Charge.
M&L for 20mm thick Granite (of any colour) tiles machine cut in skirting/dado set and including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 20 mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L Machine cut cudappah stone slab 20-25mm thick over 20mm thick cement screed in CM 1:4, base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer in charge.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed by Engr-in- Charge.
M&L for Vitrified Ceramic tiles double charge , dark shade 10 mm thick (square/ rectangular) polished, area of each tilest exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm screed bed or bedding layer for floor finishes in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for raking, cutting and waste on glazed tiles complete all as specified and directed by Engineer in charge.
M&L for screed bed or bedding layer of mortar 15mm thick in CM (1:6) for laying floor finishes complete all as specified and directed by Engineer in charge.
M&L for joint free coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm or 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed by Engr-in- Charge.
M&L for 10mm thick rendering in CM 1:6 on brick or concrete surface as backing coat complete all as specified and directed by Engr-in- Charge.
M&L Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for including tar felt etc and removing debris outside MD land complete all as specified and as directed by Engr-in- Charge.
M&L for water proofing treatment with APP based polymeric membrane over 15mm thick plaster on roof with the following courses of treatment :- (a) Complete removal of existing treatment, cleaning & washing the concrete /tiles surface by using wire brush including junction of parapet etc. (b) M&L 15mm thick cement plaster in CM 1:4 using water proofing liquid as per manufacturer instructions over neat cement slurry @ 3kg/Sqm on roof surface. Note: Water proofing liquid /compound will be measured & paid separately. (c) Applying bituminous primer (IS 3384) @ 0.160 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (d) M&L for APP based polymeric membrane minimum weighing 3 kg/Sqm and minimum 3mm thick reinforcement with polyster non woven fabric (wt of reinforcement not less than 150gms/sqm) laid in primed surfaced application including preparation and applying two coats of Heat resisting Aluminium paint over APP membrane complete all as specified and directed.
M&L for cement concrete (1:3:6) type C1 in foundation filling and mass concrete using 20mm graded stone agg for roof padding work as required on site etc complete all as specified and directed by Engr-in- Charge.
Supply only Liquid water proofing compound complete all as specified and as directed by Engr-in- Charge.
S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work to timber/rubber beading in ceiling flat or slopping complete all as specified and as directed by Engr-in- Charge.
S&F 18mm to 19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work to timber/rubber beading in ceiling flat or sloping complete all as specified and as directed by Engr-in- Charge.
M&L for 12 mm thick plywood (9 ply), grade BWP, type BB fixed with screws to timber frame work complete all as specified and as directed by Engr-in- Charge.
S&F in repairs, magnetic catch and connecting plate to shutters and frame complete all as specified and as directed by Engr-in- Charge.
M&L in repairs for 2nd class hardwood, plain fillets, square , rectangular or triangular in section, bull nosed, splayed, chamfered or rounded on one edge or face in sectional area exceeding 6 and not exceeding 25 sq.cm fixed with nails complete all as specified and as directed.
M & L for new surface preparation of wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr-in- Charge.
S&F 150 mm long aluminum anodised barrel tower bolts of extruded section of size complete all as specified and directed by Engineer in charge.
S&F stainless steel 100 mm long butt hinges, medium weight by welding to existing frame including taking down old hinges complete all as specified and directed by Engineer in charge.
S&F 300 mm long ordinary rat rail rod pattern spring (Helical spring) of mild steel, including roller and roller plate complete all as specified and as directed by Engineer in charge.
S&F aluminium anodised handles 150 mm long of extruded section for door fixed with stainless steel screws including taking down old handles complete all as specified and as directed by Engineer in charge.
S&F hasp and staple safety type of size 100mm of aluminium anodized including taking down old hasp and staple complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of size exc 1 sqm and n exc 2 sqm each and refixing in the same opening including necessary adjustment after laying of floor tiles complete all as specified and directed by Engr-in-charge.
M&L for 6 mm thick plywood , grade BWP, type BB fixed with screws to timber frame work complete all as specified and as directed
S&F in repairs, 20mm dia aluminium powder coated tubular curtain rod including taking down of old complete all as specified and as directed by Engr-in- Charge.
S&F aluminium powder coated, fancy type, decorative brackets, suitable for 20 mm dia curtain rod (minimum projection from wall 75 mm ) fixed to wall including drilling, rawl plug screws etc complete all as specified and as directed by Engr-in- Charge.
S&F in repairs Powder Coated aluminium frame (any colour) for partitions, doors, windows, ventilators with one or more rebates including joining cleat for fixing, fittings like hinges , handles, locks etc.(sealing of window/door frames with sillicon gel to avoid rain water entry) complete all as specified and as directed by Engr-in- Charge.
S & F Rubber gasket for aluminium frame for windows, Ventilators etc complete all as specified and as directed by Engr-in- Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden /metal frames or stone, concrete glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips complete all as specified and directed by Engineer in charge.
S&F in repairs 3mm thick sheet glass ordinary quality, pin head type and glazing with oil putty /or wooden beads in squares n exc 0.50 sq. m in each pane complete all as specified and directed by Engineer in charge.
S&F in repairs 3mm thick Figured glass, pin head type and glazing with oil putty /or wooden beads in squares n exc 0.50 sq. m in each pane complete all as specified and directed by Engineer in charge.
S&F 5.5mm thick sheet glass glazing with oil putty or wooden/ rubber beads in squares n. exc 0.50 sqm in each pane complete all as specified and directed by Engineer in charge.
S&F for welding in repairs Mild steel roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections), steel gates / windows / doors exc 2.5 cm but not exc 5.00 cm in length and thickness of metal to be welded exc 9 mm but not exc 20mm including distance pieces, cleats etc. Fe-410 W(Gde E-250) complete all as specified and directed by Engr-in- Charge.
S&F 40 mm dia, cupboard knob, fixed with nut, screw and washer, of mild steel bright finished complete all as specified and as directed by Engr-in- Charge.
S&F in repairs 15 mm bore pillar taps fancy type (long neck) cast copper alloy with capstan heads chromium plated screwed down high pressure with or without letter hot or cold with long screwed and shanks and fly nuts screwed for iron pipes complete all as specified and directed by Engineer in charge.
S&F for 15 mm bore stop valves chromium plated fancy type screwed down high pressure with crutch or batterfly handle screwed both ends for iron pipes or for union fixed in repair complete all as specified and as directed by Engr-in- Charge..
S&F in repairs 15 mm size stop valve with long shank (consealed type) cast copper alloy, chromioum plated fancy type, screwed down, high pressure with capston head, screwed both ends for iron pipe or for union all as specified and as directed by Engr-in- Charge.
S & F 20 mm size gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed by Engr-in- Charge.
S&F 15 mm size stop valve of PTMT any colour high pressure screwed for iron pipe, weight not less than 90 gms, including taking down old stop valve all as specified and as directed.
S&F in repairs 15 mm size bib taps cast copper alloy chromium plated fancy type screwed down, with capstan head screwed for iron pipe complete all as specified and as directed.
S&F in repairs 15mm dia GI steel water tubing medium grade ISI marked laid in trenches or fixed to walls and ceilings or laid in floors with and including all fittings such as bends, elbows,tees, short pieces etc complete all as specified and directed by Engr -in- Charge.
M & L for taking up or down carefully 20 mm bore steel tubing and connections complete all as specified and as directed by Engr -in- Charge.
M & L for Re-fixing of 20 mm bore galvanized iron tubing medium grade retrieved from item No 81.00 here-in-before, after cleaning of tube and including all fittings and fixtures fixed to walls / ceiling or laid to floors complete all as specified and as directed by Engr -in- Charge.
S&F 20mm dia GI steel water tubing medium grade ISI marked laid in trenches or fixed to walls and ceilings or laid in floors with and including all fittings such as bends, elbows,tees, short pieces etc complete all as specified and directed by Engr -in- Charge.
S&F LPDE waste pipes of 32mm bore pressure rating 6 Kgf/Sqcm length 1.20 mtr for wash hand basin, all as specified complete all as specified and directed by Engineer in charge.
S&F LPDE waste pipes of 40mm bore pressure rating 6 Kgf/Sqcm length 1.20 mtr for wash hand basin, complete all as specified and directed by Engineer in charge.
Supply and fix in repairs 32 mm size waste coupling of PTMT for wash hand basin / urinal / sink complete complete all as specified and directed by Engineer in charge.
Supply and fix in repairs 40 mm size waste coupling of PTMT for wash hand basin / urinal / sink complete complete all as specified and directed by Engineer in charge.
S&F health faucet with 15 mm bore dia chromium plated angle cock with stud complete all as specified and as directed by Engr-in- Charge.
S & F in repairs Teflon tape adhesive sealant length 10 m , width 1.5 cm complete all as specified and as directed by Engr-in- Charge.
S&F in repairs High density polythene pipe(HDPE), 15 mm bore of pipes of pressure rating 6 Kgf /Sq cm fixed complete to wall or laid in tranches or floors etc (15 mm bore) incl all fittings complete all as specified and directed by Engineer in charge.
S&F in repairs High density polythene pipe(HDPE), 20 mm bore of pipes of pressure rating 6 Kgf /Sq cm fixed complete to wall or laid in tranches or floors etc (20 mm bore) incl all fittings complete all as specified and directed by Engineer in charge.
M&L for Carefully Chiseling/ Chipping out all existing loose decayed plaster in affected patches of (Columns,Beams,Slabs and Pardi and walls) using Saw cutter machine, Plaster Breaking machine and/or Well sharpened Chisel & Hammers at proper angles carting away the debris outside of building premises etc complete all as specified and directed by the Engr-in- Charge. Note: • No Holes shall be made in the Wall to support the Scaffolds • No direct hammering shall be allowed while breaking of plaster. • No extra payment shall be made for extra thickness broken if encountered. • Hammers weighing more than 2 kg shall not be used • Prior to breaking of the plaster, Areas shall be demarcated and got approved by the Consultants.
M&L for 20/25 mm thk sand faced plaster to concrete members- brick work on external facades, etc using approved screened and pre washed river sand including base coat of 13-15mm thick in C.M. 1:4 and curing the same for not less than three days and keeping the surface of base coat rough to receive the sand face treatment 6 to 8 mm thick of C. M 1:3 finishing the surface by taking out grains and curing for 7- 10 days, providing and mixing polyproplyene fibres and approved waterproofing compound in required quantities in both the coats complete all as specified and directed by Engr-in- Charge. Rates are inclusive of making Pattas, Drip moulds, Corners etc as specified and directed. Sand shall be screened and washed on site (if necessary) for Silt Content less than 4 % and in confirmation to IS 383 Zone II Note: The rates shall be inclusive of erecting single/double bamboo scaffolding including fixing of Hessian clothing.
M&L for Chipping out all existing loose and decayed internal plaster and redoing the same with 15mm thk. Cement plaster in CM (1:4) finishing with ‘Instant Neeru’ of Elephant Brand or equivalent on the internal walls of the Bldg. (inside areas of staircase areas and over Internal Structural Members all as specified and directed.
M&L for Dismantling plain or corrugated steel sheeting , fibre, AC sheet, ( corrugated , semi corrugated etc) any gauge, thickness sheets including Nainital or similar pattern roof coverings in any position complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting (PPGL) 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws etc including steel double scaffolding height 5.12 mtr to 15 Mtr complete all as specified and directed by Engineer in charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting (PPGL) 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws etc including steel double scaffolding height 12 mtr to 15 Mtr complete all as specified and directed by Engineer in charge.
S&F in repairs 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed by Engr-in- Charge..
Taking down gutter (steel sheet) of any discription and in any position with necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
S&F 1 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley,eaves gutters half round with rounded edges, drip and straight flashings ( length and girth as fixed) with grade of zinc coating 275 ,complete all as specified and as directed by Engr-in- Charge.
Dismantling AC sheets as in roof covering is any position including necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
S&F for 6mm thick asbestos cement corrugated or semi-corrugated sheets in roofts fixed with `J' type hooks including necessary steel double scaffolding ( 12 m to 15 Mtr Height) complete all as specified and as directed by Engr-in- Charge..
Dismantling wrought iron or mild steel work of any description not otherwise provided for including necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge..
S & F mild steel Fe-410-W(Gde-E-250) quality-B, Joist, channel,angle,or tee sections, fixed independently,connecting plates,roof trusses , purlins etc, (cut to ordinary lengths i.e.within 20mm of the length indicated), intricate design including necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment,flat iron, Fe 410-W (Gde-E-250) quality-B,etc , intricate design , including necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
M & L for Mild steel screw bolts (machine made) 5 to 10mm dia of neck in mm with hexagonal or square heads at one end and screwed the others or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed by Engr-in- Charge.
M & L in repairs for Mild steel screw bolts (machine made) 11 to 15mm dia of neck in mm with hexagonal or square heads at one end and screwed the others or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long complete all as specified and as directed by Engr-in- Charge.
M & L in repairs for Mild steel screw bolts (machine made) 16 to 20mm dia of neck in mm with hexagonal or square heads at one end and screwed the others or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut,exc 10cm but n exc 15 cm long complete all as specified and as directed by Engr-in- Charge.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges; clamps; hold fasts; wall ties plain angle clets for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps ,plate washers and similar small articles conforming to Fe.290. Gde-E-165 including necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
M&L for Preparation of new steel surface of any description over 10 Cm in width or girth, not otherwise described applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer including necessary steel double scaffolding ( 12 mtr to 15 Mtr height) complete all as specified and directed by Engineer in charge.
M&L for Preparation of old steel surface of any description over 10 Cm in width or girth, not otherwise described applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer including necessary steel double scaffolding ( 12 mtr to 15 Mtr height) complete all as specified and directed by Engineer in charge.
M&L for Preparation of old steel surface of any description not exceeding 10 Cm in width or girth, not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including necessary steel double scaffolding ( 12 mtr to 15 Mtr height) complete all as specified and directed by Engineer in charge.
Taking down Nylon bird netting fixed with tinned tacks or GI wires including screwing and necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
S&F Nylon bird netting mesh Hole 32 mm size , length 250 feet, breadth 10 Ft and its breaking strength 18 Kg approx and melting point above 80 Degree including screwing and necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
M & L for Refixing of Nylon bird netting mesh Hole 32 mm size, length 250 feet, breadth 10 Ft and its breaking strength is 18 Kg approx and melting point above 80 Degree including scewing and necessary steel double scaffolding (12 m to 15 M Height) complete all as specified and as directed by Engr-in- Charge.
S & F in repairs PVC 160 mm bore rainwater drainage pipes , waste, soil ,(SWR) PVC SWR pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed by Engr-in- Charge.
S & F PVC (SWR) pipes 110mm dia in any length with rubber ring joints fixed to walls/trenches/floors etc complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) bend 160 mm dia with access door bends complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) bend 110 mm dia with access door bends complete all as specified and directed by Engineer in charge.
S & F PVC 160mm bore (SWR) coupler complete all as specified and directed by Engineer in charge.
S & F PVC 110mm bore (SWR) coupler complete all as specified and directed by Engineer in charge.
Demolition of brick work / stone built in cement / lime mortar including all quoins, arches, pillars etc and removing debris outside MD land complete all as specified and directed by Engr-in- Charge.
M&L for brick work with sub-class 'B' bricks, straight or curved on plain to any radius in full brick thick walls, 230mm thick built in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M & L for cutting out bricks, forming jambs ,toothing for and bondinng new into old work incl value of new materials entering old walls and jointing and pointing in cement mortar (1:4) complete all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster on brick or stone walls, etc including racking out joints hatching for key, scrubbing down with water etc complete all as specified and as directed by Engr-in- Charge.
M&L for 10mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces, drain walls & finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
M&L for applying two coats of oil bound distemper over a coat of primer,over 3 mm thick wall care putty on walls including preparation of new or previously untreated surfaces complete all specified and directed by Engr-in- Charge.
M&L for rendering in two layers on external surfaces first layer 10mm thick in CM 1:6 on stone masonry surfaces and second layer ( setting coat / finishing) 5mm thick in CM 1:4 with approved water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge. (Note:- WPC shall be measured and paid seperately)
M&L for complete removal of existing treatment on wall and applying two coats of oil bound distember over a coat of alkali resistane primer over 3mm thick wall care putty on walls complete all as specified and directed by Engr-in- Charge.
M&L for preparing for old plaster surfaces on walls and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 mg/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified and directed by Engr-in- Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in- Charge.
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces complete all as specified and directed by Engr-in- Charge.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces complete all as specified and directed by Engr-in- Charge.
Taking down UG Cable of any size/ capacity complete all as specified and directed by Engr-in- Charge.
Taking down ceiling fan /EXHAUST FAN of any size or make and refixing the same after repair work complete all as specified and directed by Engr-in- Charge.
Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm stranded for earth continuity wire, to be drawn in and including, PVC medium grade Conduit not less then 20 mm width with modular metal sunken switch with face plate for modular switch complete with brass screws with cup washers including all necessary wall cutting and making good disturbed surface complete all as specified and directed by Engr-in- Charge:- Note : (1) Making good to match with the adjoining surface shall be included in the unit rate. (2) Rate is inclusive of Cutting/chases of wall/floor/ceiling
One light point controlled by one, one way switch complete all as specified and directed by Engr-in- Charge.
One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed by Engr-in- Charge.
One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed by Engr-in- Charge.
One3 pin 5 amps socket out let point on independent board complete all as specified and directed by Engr-in- Charge.
One bell/buzzer point controlled by one bell push complete all as specified and directed by Engr-in- Charge.
All as per item above 138 but for one socket outlet 15 Amp on independent board with 4 Sq mm cable and 2.5 Sq mm earth wire. complete all as specified and directed by Engr-in- Charge.
All as per item above 138 but for one socket outlet 15 Amp on independent board with 2.5 Sq mm cable and 1.5 Sq mm earth wire. complete all as specified and directed by Engr-in- Charge.
S&F Modular switch 1 way 6 A, module complete all as specified and directed by Engr-in- Charge.
S&F Modular switch 1 way 16 A, module complete all as specified and directed by Engr-in- Charge.
S&F Modular bell push 6 A ,1 module complete all as specified and directed by Engr-in- Charge.
S&F Socket, 6A-2/3 pin combined 2 module complete all as specified and directed by Engr-in- Charge.
S&F Socket, 6A/16A-3/5 pin combined 2 module complete all as specified and directed by Engr-in- Charge.
S&F Metal flush box 1/2 module complete all as specified and directed by Engr-in- Charge.
S&F Metal flush box 3 module complete all as specified and directed by Engr-in- Charge.
S&F Metal flush box 4 module complete all as specified and directed by Engr-in- Charge.
S&F Metal flush box 6 module complete all as specified and directed by Engr-in- Charge.
S&F White cover plate with frame, 1 module complete all as specified and directed by Engr-in- Charge.
S&F White cover plate with frame, 2 module complete all as specified and directed by Engr-in- Charge.
S&F White cover plate with frame, 3 module complete all as specified and directed by Engr-in- Charge.
S&F White cover plate with frame, 4 module complete all as specified and directed by Engr-in- Charge.
S&F White cover plate with frame, 6 module complete all as specified and directed by Engr-in- Charge.
S&F White cover plate with frame, 8 module complete all as specified and directed by Engr-in- Charge.
S&F bell, AC, 230 volts, single pole complete all as specified and directed by Engr-in- Charge.
M&L for ceiling rose PVC / Polycarbonate insulated body two to three terminal complete all as specified and directed by Engr-in- Charge.
M&L Modular Fan step rerulator 120 W-2 module complete all as specified and directed by Engr-in- Charge.
S&F in repairs single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified and directed by Engr-in- Charge.
S&F LED fittings decorative 36/34 watt surface/ recess mounting type extruded metal / aluminium body, and electronic LED driver,connector block ect. with all accessories internal prewired & and including connecting up with twin core twisted with flexible copper conductor cable with suitable size with mounting clamp etc complete all as specified and directed by Engr-in- Charge.
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat srink envioromentel friendly Energy efficient ready to use pack , 20 Watt , 4 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc complete all as specified and directed by Engr-in- Charge.
M&L for sub main wiring with two single core 10 Sqmm FR PVC insulated and sheathed 1100 Volts grade, standed copper conductor ISI marked drawn into fixed in an including Casing -N-Caping/conduit with all fitting and accessories and one continuous run of 6.0 Sqmm copper conductor PVC insulated (green colour) as earth wire complete all as specified and directed. Note :- Two single core cables along with earth wire and Casing -N-Caping shall be measured as one unit length complete all as specified and directed by Engr-in- Charge.
M&L for sub main wiring with two single core 6 Sqmm FR PVC insulated and sheathed 1100 Volts grade, standed copper conductor ISI marked drawn into fixed in an including Casing -N-Caping/conduit with all fitting and accessories and one continuous run of 4.0 Sqmm copper conductor PVC insulated (green colour) as earth wire complete all as specified and directed. Note :- Two single core cables along with earth wire and Casing -N-Caping shall be measured as one unit length complete all as specified and directed by Engr-in- Charge.
Supply and fixing of DB vertical double door TPN 4 Way 415 volts complete all as specified and directed by Engr-in- Charge.
Supply and fixing of DB double door SPN 8 Way 240 Volts complete all as specified and directed by Engr-in- Charge.
Supply and fixing of MCB SPN 63 Amps, 10 KA, 240 Volts complete all as specified and directed by Engr-in- Charge.
Supply and fixing of MCB SP 10 to 32 Amps, 10KA ,240 Voltscomplete all as specified and directed by Engr-in- Charge.
Supply and fixing of MCCB TPN 100 Amps, 16 KA,415 Volts complete all as specified and directed by Engr-in- Charge.
Supply and fixing of exhaust fan 300 MM sweep, 230 volts, 50 hz, metallic grey colour with louvers including taking down unservviceable exhaust fan from existing place & deposited into AGE E/M (AF) Mumbai store yard and making good for disturbed surfaces complete all as specified and directed by Engr-in- Charge.
Supply and fix ceiling fan 1200 MM sweep, 230 volts, 50 hz, including taking down unservviceable ceiling fan from existing place & deposited into AGE E/M (AF) Mumbai store yard and making good for disturbed surfaces complete all as specified and directed by Engr-in- Charge.
Excavation in trenches in hard /dense soil n exc 1.5 m wide and n. exc 1.5mtr in depth for laying of cables poles stay, and getting out complete all as specified and directed by Engr-in- Charge.
Returning filling in incl spreading,watering and well ramming in layers n exc. 25 cm thick after the cable are laid complete all as specified and directed by Engr-in- Charge.
Removal of surplus soil to a distance n exc 50 m and depositing ehere directed at a level n exc 1.5m above the starting point complete all as specified and directed by Engr-in- Charge.
Supply and spreading clean dry sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed by Engr-in- Charge. (Only punned thickness shall be measured)
Supply and laying un reinforced precast concrete cable cover, class LV,type I flat size 250mm X 150mm X 40mmcomplete all as specified and directed by Engr-in- Charge.
Supply and laying galvanised pipe light grade of size 80mm dia for cable protection in trenches complete all as specified and directed by Engr-in- Charge.
Supply, laying and testing cable XLPE With Aluminum conductor multistanded 1100 volts grade in armoured, electric power cables (heavy duty) and including taking out unserviceable from trench /wall/floor/into pipe/ceiling and with suitable size of lugs nuts,bolts. and washers and including taking out unserviceable cable from existing place complete of size 50 sq mm 4 corecomplete all as specified and directed by Engr-in- Charge.
M&L for cutting into the existing road/hard standing surfaces to a depth of 60cm and 50cm wide and getting out for laying under ground cable including returning filling in, watering, well ramming in layers not exceeding 25cm in any type of soil and filling the top surface 15cm thick with PCC 1 : 1.5 : 3 type B1 using 20mm graded stone aggregate and finished even and fair without using extra cement including disposal of surplus soil complete of size 50 sq mm 4 corecomplete all as specified and directed by Engr-in- Charge.
Note :- (a) Complete work under BOQ to be carried out in Hangar/annexure bldg of height appox 15 meter. Rate quoted by the contractor shall deemed to be included all necessary arrangements for working at height. (b) Structual rehabilitation work considered in BOQ shall be carried out under strict supervision of a qualified MES enlisted structural Engineer as approved by GE (whose documents shall be obtiained and kept on record). Contractor shall have a MOU with MES enlisted structural Engineer to this effect which shall be approved by the GE before execution of the work. (c) On completion of structural repair non distructive tests (NDT) shall be undertaken by an expert agency on the structure under supervision of GE, Engineer-in-Charge & structural Engineer to ascertain the enhance strength of repaired area and accordingly the structural Engineer shall furnish a fitness certificate and gurantee of structural safety at least for ten years, which shall be kept on record. (d) Rate quoted by the contractor shall be inclusive of hiring charges of structural Enginer and conducting NDT tests.
KAJAL CONST.
M/S DEV ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .