Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹47.9 L+₹44,298 (0.93%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹49.5 L+₹2.0 L (4.15%)Admitted-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L3 | Admitted-Finance | |
| 4 | L4₹50.2 L+₹2.7 L (5.78%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹53.6 L+₹6.1 L (12.9%)Admitted-Finance 203 NIVAAN LAXMI SOCIETY PLOT NO 169 SECTOR 19 KHARGAHAR NAVI MUMBAI 410210 | RAIGAD | MAHARASHTRA | 410210 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | pk Enterprises L3 | DARSHAN CONSTRUCTION Co. L4 | cooltech engineering services L7 | somnath engineering corporation L1 | BRITE INDUSTRIES L2 | Shree Ayyappa Engineering L6 | BALAJI TRADERS L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down defective /unserviceable Air Curtain (4 feet) of existing Make and capacity 1 to 1.5 m/sec air velocity at floor level, transporting to company authorized outlet , collecting company repaired Air curtain of same make and transporting back to site , re-fixing at original position complete including testing and commissioning the machine onto the mounting plate and ensure the safety than fix it tighten with screw complete all as specified and directed by Engr-in-Charge. | 6 | Each Job | 3,025 ₹18,150 | 3,325 ₹19,950 | 5,000 ₹30,000 | 13,000 ₹78,000 | 2,000 ₹12,000 Lowest | 3,500 ₹21,000 | 3,100 ₹18,600 |
| 2.00 | Repair/Replacement of unserviceable blower motor, damaged blower, impillers unbalanced blower wheel of air curtain of capacity capacity 1 to 1.5 m/sec air velocity at floor level and remove, clean or replace air intake screen & filters of air curtain, obstruction in discharge path (i.e door headers, automatic door openers etc), check electrical connection, replace the fuse and servicing and overhauling complete unit specified and directed by engr in charge. Make - Beacon, Akash or equivallent | 6 | Each Job | 3,230 ₹19,380 | 2,825 ₹16,950 | 5,000 ₹30,000 | 13,000 ₹78,000 | 2,000 ₹12,000 Lowest | 3,500 ₹21,000 | 3,190 ₹19,140 |
| 3.00 | Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, out let air velocity not less than 610 m/min and noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for 61 to 120 TR capacity AC plants. | 2 | Each | 20,556 ₹41,112 | 17,500 ₹35,000 | 21,000 ₹42,000 | 13,000 ₹26,000 Lowest | 18,500 ₹37,000 | 20,000 ₹40,000 | 22,780 ₹45,560 |
| 4.00 | Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, out let air velocity not less than 610 m/min with noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for upto 60 TR capacity AC plants. | 4 | Each | 15,225 ₹60,900 | 18,700 ₹74,800 | 22,000 ₹88,000 | 13,000 ₹52,000 Lowest | 15,000 ₹60,000 | 20,000 ₹80,000 | 16,145 ₹64,580 |
| 5.00 | Material and labour for taking out all old unserviceable PVC fills from cooling tower of capacity upto 100 TR and supply and fix in replacement of eliminator of cooling tower upto 100 TR complete all as specified and directed. | 450 | Each | 474 ₹2,13,300 | 352 ₹1,58,400 | 500 ₹2,25,000 | 275 ₹1,23,750 Lowest | 400 ₹1,80,000 | 430 ₹1,93,500 | 475 ₹2,13,750 |
| 6.00Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities sush as silt, dust particles mud/ sand inside the dume and around the fins,cleaning of base tray & grills, pot stainer, main shaft etc and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including testing commissioning after reassembling complete including painting all as directed by Engr-in-charge | ||||||||||
| 7.00 | Cooling tower of capacity upto 35 TR | 12 | Each Job | 2,952 ₹35,424 | 3,112 ₹37,344 | 3,000 ₹36,000 | 1,350 ₹16,200 Lowest | 3,000 ₹36,000 | 3,200 ₹38,400 | 3,155 ₹37,860 |
| 8.00 | Cooling tower of capacity 66 TR to 250 TR | 2 | Each Job | 4,812 ₹9,624 | 3,812 ₹7,624 | 4,000 ₹8,000 | 1,800 ₹3,600 Lowest | 5,000 ₹10,000 | 4,200 ₹8,400 | 4,750 ₹9,500 |
| 9.00 | Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 61 TR and above Capacity AC plant. | 1 | Each | 15,460 ₹15,460 | 17,803 ₹17,803 | 15,000 ₹15,000 | 12,500 ₹12,500 Lowest | 15,300 ₹15,300 | 18,000 ₹18,000 | 16,100 ₹16,100 |
| 10.00 | Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of upto 60 TR capacity AC plants. | 4 | Each | 14,555 ₹58,220 | 15,503 ₹62,012 | 15,000 ₹60,000 | 12,500 ₹50,000 Lowest | 15,300 ₹61,200 | 18,000 ₹72,000 | 16,450 ₹65,800 |
Tender Value
₹53 L
EMD Value
₹1.1 L
Closing Date
29 Jun 2026, 6:00 pmClosed
CWE Karanja
CWE KARANJA NAVAL STATION KARANJA
REPAIR REPLACEMENT AND IMPROVEMENT TO DEFECTIVE PARTS OVERHAULING OF COMPRESSOR HOT COLD WATER PIPE LINE INSULATIONS AHU FILTERS HEATERS DE-SCALING OF CONDENSER CHILLER AND THEIR DEFECTIVE ACCESSORIES CERTAIN ESSENTIAL SPARES AND OTHER
2026_MES_769160_1
84538-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Station Karanja
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE NW Karanja
₹1.1 L
14 Jul 2026
2 Jun 2026
2 Jul 2026
2 Jun 2026
29 Jun 2026
22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down defective /unserviceable Air Curtain (4 feet) of existing Make and capacity 1 to 1.5 m/sec air velocity at floor level, transporting to company authorized outlet , collecting company repaired Air curtain of same make and transporting back to site , re-fixing at original position complete including testing and commissioning the machine onto the mounting plate and ensure the safety than fix it tighten with screw complete all as specified and directed by Engr-in-Charge. | 6 | Each Job | - | - |
| 2 | Repair/Replacement of unserviceable blower motor, damaged blower, impillers unbalanced blower wheel of air curtain of capacity capacity 1 to 1.5 m/sec air velocity at floor level and remove, clean or replace air intake screen & filters of air curtain, obstruction in discharge path (i.e door headers, automatic door openers etc), check electrical connection, replace the fuse and servicing and overhauling complete unit specified and directed by engr in charge. Make - Beacon, Akash or equivallent | 6 | Each Job | - | - |
| 3 | Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, out let air velocity not less than 610 m/min and noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for 61 to 120 TR capacity AC plants. | 2 | Each | - | - |
| 4 | Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, out let air velocity not less than 610 m/min with noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for upto 60 TR capacity AC plants. | 4 | Each | - | - |
| 5 | Material and labour for taking out all old unserviceable PVC fills from cooling tower of capacity upto 100 TR and supply and fix in replacement of eliminator of cooling tower upto 100 TR complete all as specified and directed. | 450 | Each | - | - |
| 6 | Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities sush as silt, dust particles mud/ sand inside the dume and around the fins,cleaning of base tray & grills, pot stainer, main shaft etc and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including testing commissioning after reassembling complete including painting all as directed by Engr-in-charge | - | - | - | - |
| 7 | Cooling tower of capacity upto 35 TR | 12 | Each Job | - | - |
| 8 | Cooling tower of capacity 66 TR to 250 TR | 2 | Each Job | - | - |
| 9 | Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of 61 TR and above Capacity AC plant. | 1 | Each | - | - |
| 10 | Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of upto 60 TR capacity AC plants. | 4 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
SOC.pdf
Additional Documents • 0.28 MB
Tenerdocument.pdf
Tender Documents • 0.80 MB
BOQ_861380.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .