Garrison Engineer Abohar
Garrison Engineer Abohar Mil Stn Pin 152116
SPECIAL REPAIR TO PERIMETER SECURITY LTS, UG CABLES AND CONNECTED ITEMS AT FAZILKA MILITARY STATION
2026_MES_792181_1
TOKEN NO GE ABH-32 OF 26-27
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Fazilka Mil Stn
As per NIT
7 documents required · 7 mandatory
₹500
GE Abohar
₹42,000
Yes
3 Oct 2026
3 Oct 2026
26 Oct 2026
3 Oct 2026
23 Oct 2026
17 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing cable junction box of Size 250mm x 200mm x100mm or any other higher size (Suitable for Pole mounting) complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :-
(a) The junction box shall be rated for degree of IP 65 (ingress protection) in accordance with IEC 60529.
(b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded.
(c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60695-22, IEC 60670-2 to 5 and grey color according to RAL-9011/ 7035.
(d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree.
(e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard.
(f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Suitable size of mild steel Clamps and screws/nut bolt shall be used for fixing of Junction box.. | 122 | Each | - | - |
| 2 | Supply & fixing LED of 70 Watt IP 66 Street lights fittings aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary and IP66 protection. 10 KV SPD included Efficacy ≥110/120 LPW complete all as specified and directed by Engineer-in-Charge | 180 | Each | - | - |
| 3 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge. | 601.43 | Cum | - | - |
| 4 | Excavation in trenches in any type of soil exceeding 1.5 mtr deep and not exceeding 3.0 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC/Steel tubular poles/stays and struts etc getting out including trimming sides and forming bottom surface all as specified and directed at site. | 1.21 | Cum | - | - |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge | 590.36 | Cum | - | - |
| 6 | Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge. | 11.07 | Cum | - | - |
| 7 | S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connection for street light complete all as specified and directed | 1,500 | RM | - | - |
| 8 | Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified and directed by Engr - in charge.
(a) DWC Pipe dia 77/63 | 2,376 | RM | - | - |
| 9 | M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for more than100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor with 100mm GI pipe complete all as specified and directed. | 30 | RM | - | - |
| 10 | Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. | 7 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
ca_T-32.pdf
Tender Documents • 1.39 MB
BOQ_888225.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .