Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance HARIDWAR | HARIDWAR | UTTARAKHAND | 247656 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹73.4 L
EMD Value
₹1.5 L
Closing Date
21 May 2025, 4:00 pmClosed
Executive Engineer TLMD-II JKPTCL Gladni
Office of Executive Engineer TLMD-II JKPTCL Gladni Jammu
Capital Maintenance of 1x50 MVA EMCO Power Transformer which includes complete overhauling replacement of oil at 150MVA 132/66KV Grid Station Kathua
2025_PDD_275650_1
TLMD-II/J/01 of 2025-26 dated 12.04.2025
Open Tender
Electrical Works
Turn-key
120 days
Kathua
As per NIT and SBD
3 documents required · 3 mandatory
₹5,900
Executive Engineer TLMD-II JKPTCL Gladni
₹1.5 L
20 Jun 2025
12 Apr 2025
23 May 2025
12 Apr 2025
21 May 2025
13 Apr 2025
Amount
MATERIAL AND LABOUR CHARGES REQUIRED FOR INTERNAL INSPECTION AND OVERHAULING OF 50MVA,132/66 KV EMCO MAKE TRANSFORMER
Supply of spares for overhauling, 01 No 50MVA, 132/66KV EMCO Power Transformer
Winding Temperature Indicator and Oil temperature Indicator
Marshalling Koisk Box ground mounted
Breather for transformers
Cooling fan
External paint and primer
Internal oil resistant paint
Gasket set and washers
O ring and cord (Nitrile + cork) 8 mm & 10 mm
OLTC spares and gasket set
Set of valves gate and plate type
Cables/ Cabling, Cable gland, Marking ferrule, Lugs etc details
2 core, 2.5sq mm, 1100 V, PVC Insulated, PVC Sheathed, FRLS,Galvanised Steel Wire/strip Armoured strended copper conductor Control cable complete.
5 core, 2.5sq mm, 1100 V, PVC Insulated, PVC Sheathed, FRLS,Galvanised Steel Wire/strip Armoured strended copper conductor Control cable complete.
8 core, 2.5sq mm, 1100 V, PVC Insulated, PVC Sheathed, FRLS,Galvanised Steel Wire/strip Armoured strended copper conductor Control cable complete.
12 core, 2.5sq mm, 1100 V, PVC Insulated, PVC Sheathed, FRLS,Galvanised Steel Wire/strip Armoured strended copper conductor Control cable complete.
16 core, 2.5sq mm, 1100 V, PVC Insulated, PVC Sheathed, FRLS,Galvanised Steel Wire/strip Armoured strended copper conductor Control cable complete.
Lugs,Ferrules, cable glads etc.
Consumable (Creep paper, Nomes paper, Parmali studs & nuts)
Fabrication items blanking plates, supports and flanges
PRV Relay
Transformer Oil as per IS
Labour Cost for the repair and overhauling of 50 MVA 132/66 KV ,EMCO Power Transformer
Transformer and instrument health assessment inspection after draining of complete oil from Transformer and testing
Dismantling of transformer Accessories such as Bushings, bushing turrets, Pipe lines, Inspection covers, Radiators, OLTC chamber covers, Radiator plugs for replacement of the gasket with new one and Transformer overhauling.
Erection of all Transformer Accessories as Bushings, bushing turrets, Pipe lines, Inspection covers, OLTC chamber covers, Radiator plugs after replacement of worn out gaskets with new one and dry-out cycle,Refiling of Fresh Transfomer Oil supllied above after due filteration process.
HOC and Pre-commissioning testing including DGA, BDV of oil, PPM, capacitance & tan delta of oil, Bushings and Windings, ratio test, Winding resistance test, insulation resistance of winding and core-frame-tank etc. Complete work including any miscellaneous works that may be necessary for completion of the job which includes Cabling from the Transformer CR Panel to MK Box of Transformer and ferruling etc. Further storage and Transportation of used old transformer oil from GSS Kathua to Divisional Store Gladni JKPTCL Jammu in standard barrels.
R.S ASSOCIATES (BID ID -2359609)
SHREE ABIRAMI ENGGINEERING WORKS PRIVATE LIMITED (BID ID -2364213)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .