| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹36.4 L+₹3.0 L (8.96%)Rejected-AOC | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹36.4 L+₹3.1 L (9.18%)Rejected-AOC NEAR TCP DOMAIL WARD NO 2 UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹38.0 L+₹4.7 L (14.0%)Rejected-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L4 | Rejected-AOC Rejected due to not being L1 | |
| 5 | L5₹38.4 L+₹5.0 L (15.0%)Rejected-AOC | L5 | Rejected-AOC Rejected due to not being L1 |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
16 Feb 2023, 6:00 pmClosed
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 72 2022 23 SPECIAL REPAIR TO BUILDING NO NP 56 SUB AREA INCLUDING CERTAIN SANCTION JOBS AT DIFFERENT LOCATIONS OF AGE BRI AND AGE BRII OF GE (NORTH) UDHAMPUR
2023_MES_576275_1
GE/U(N)/72/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹95,000
Yes
30 Mar 2023
20 Jan 2023
18 Feb 2023
20 Jan 2023
16 Feb 2023
2 Feb 2023
Amount
M&L for surface excavation n.exc 30cm deep & averaging 15cm deep and getting out in any type soil complete all as specified and directed by Engr-in-Charge.
M&L for excavating over areas, n exc 1.5 m deep and getting out of any type of soil complete all as specified.
M&L for excavation in trenches n.exc 1.5m wide & n.exc 1.5m in depth getting out in any type soil complete all as per specified.
M&L for removing excavated material n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point complete all as per specified.
M&L for returning filling including spreading leveling watering and well ramming in layers exc. 25 cm all as specified complete all as per specified.
M&L for broken stone hardcore of gauge excedding 63mm and not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, wtered and rammed to a true surface, complete all as specified and as directed by Engr-in-charge
M&L for plain cement concrete 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation conconrete mass filling complete all as per specified.
M&L for providing plain cement concrete type B1 (1:2:4) 20 mm graded aggregate as in coping all as specified & directed by Engr-In-charge.
M&L for providing, pre cast cement concrete 1:2:4 type B-1 (20mm graded) as in kerb stones and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-charge.
M&L for demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and recast concrete articles all as specified.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) with old size bricks complete all as specified and directed by Engr-in-Charge.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engr-in-Charge
M&L for walling of random rubble stone masonary uncoursed well bonded, bedded and solidly hearted built in cement mortar 1 :6 complete all as specified & directed by Engr-in-Charge.
M&L for providing and fixing power coated aluminium (minimum thickness of power coating 50 micron) for shutters of doors,windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprane gasket required (fitting shall be paid for seprately) with extruded built up standard tubular section /appropriate Z section and other section of approved make confoRming to IS:733 and IS:1285 fixing with dash fastner of required dia and size, including necessary filling up the gaps at junctions i.e. top, bottom and sides with required EPDM rubber/neoprene gasket etc.Aluminiums section shall be smooth ,rust free,straight mitred and jointed mechanical wherever required including cleat angle, aluminium snack beedingfor glazing/panneling,CP brass / stainless steel screws all as complete as per architectural drawing and the direction of Engineer-in-charge.
S&F glazing with 5mm thick frosted/tinted sheet glass exc 0.50 Sqm in each panel fixed to aluminium section of doors, windows and fixed frame with suitable EPDM rubber packing and powder coated aluminium beading to frame complete all as specified.
M&L for demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
M&L for demollition of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed by Engr-in-Charge.
M&L for dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge
M&L for 50 mm thick plain cement concrete type C-1 1:3:6(Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed. Note : The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item complete all as specified and directed by Engr-in-Charge
S & F chequered reflective ceramic tiles 30cm by 30cm and 10-12 mm thick, with grey cement and pigments, set, jointed over 15 mm thick screed bed in CM 1:4, and pointed in neat cement slurry in floors complete all as specified and directed by Engr-in-Charge.
M&L for 50mm thick cement concrete 1:2:4 type B2 using 40 mm graded stone aggregate in sub base of floor complete all as specified and directed
M&L for 75 mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and as directed by Engr-in-charge
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the incl rubbing and polishing complete over and including screed bed 15 mm thick in CM (1:4) complete all as specified and directed.
Ditto all as per srl item no 24 above but on vertical surfaces as risers incl M&L 5 mm thick screed in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for marble strip cut to width n.exc 100mm wide fixed as border etc., complete all as specified and directed
M&L for non skid coloured glazed ceramic tiles area of each tile exc. .11 Sqm but n.exc. 18 Sqm 7mm to 8mm mm thick as in floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed of cement mortar(1:4) complete all as specified and directed by Engr-in-Charge.
M&L for non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed with spacer and laid with epoxy grout in neat cement slurry and pointed to match including 10 mm screed bed 1:4 cement mortar complete all as specified and directed by Engr-in-Charge.
M&L for glazed ceramic tiles 300x450x7 mm to 8mm thick in vertical surfaces such as skirting, dadao and risers to steps over 10 mm thick in CM(1:4) incl taking down from existing surfaces complete all as specified and directed.. complete all as specified and directed by Engr-in-Charge
M&L for coloured vitrifired ceramic tiles 10mm thick (square) polished , light shade, area of each tiles exc 0.18 Sqm but n.exc 0.38Sq.m (min. size 600mm x 600mm) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement incl 10mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for coloured vitrifired ceramic tiles 10mm thick (square) polished , light shade, area of each tiles exc 0.18 Sqm but n.exc 0.38Sq.m as in skirting, etc, set and jointed in neat cement slurry and pointed in white or coloured cement incl 10mm thick rendering in CM (1:4) complete all as specified and as directed.
M&L for machine pressed vibro mechnically floated interlocking cement paver block ISI marked any shape and size confoRming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with topping of cement mexed with improted pigment. Laid over & including 50mm thick sand cushioning including wel ramming, complete all as specified and as directed by Engr-in-charge shape shall be approved by Engr-in-charge.
M&L for taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick in cement mortor 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortor 1:6 other than fair faces of brick work or concrete surfaces complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified.
M&L for preparation of plastered surfaces of wall and applying two coats of cement base paint over one coat of cement primer new surfaces with alkali resistant primer paint all as specified.
M&L for two coat of cement base paint over a coat priming plastered and other surfaces with alkali resistant primer paint including preparation of old plastered of wall complete all as specified and directed by Engr-in-Charge.
M&L for preparation of surfaces plastered or unplastered new surfaces and applying two coats of oil bound distemper over a coat ofchalk whiting preparatory to distempering and including 1 mm wall care putty complete all as specified and directed by Engr-in-Charge
M&L for complete removal ofexisting treatment and preparation of surfaces plastered or unplastered old surfaces and applying two coats of oil bound distemper over a coat ofchalk whiting preparatory to distempering and including 1 mm wall care putty complete all as specified and directed by Engr-in-Charge
M&L for one coat of enamel paint on wooden surfaces over a coal of pinkprimer incl preparation of old Surfaces of any description, not otherwise descri-bed, over 10cm width or girth complete all as specified and directed by Engr-in-Charge.
M&L for dismantling ceiling boards,fibre pulb insulation etc or insulation boards/slabs/blankets,any thickness, including cover and MS Grid frame complete all as specified and directed by Engr-in-Charge
S&F in repairs MS powder coated snap grid frame work with 20 X 25 mm 'T' and 'L' section with grid size of 605 mm X 605 mm including with necessary 3.15 mm GI wire as suspenders etc. complete all as specified and directed by Engr-in-Charge.
S&F in repairs of false ceiling boards of t Fibre Cement Designer tile white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 1220mmx1220mm / 1195mmX595mm /1220mmX610mm/595 mm X 595 mm or any other suitable size as per existing grid frame work and any one of the design (occeanic , lake & hill, cascade or electra) in true horizontal level, suspended on existing inter locking metal grid including required cutting/making opening for services like fixed over existing grid inluding necessary scaffolding etc and refixed all exesting electric wiring and fixture all complete at all heights as per direction of Engr-in-charge.
S&f false ceiling with fiber cement designer tile lvory/white paintwd (high pressure steam cured)of 4mm thickness (as per IS-14862 )of size 595X595mm and any one of the design (occeanic,lake & hill cascade or electra) in true horizontal level,suspended on interlocking power coated certa black pattern metal grid of hot dipped galvanised steel section(galvanised @12gms both side inclusive ) consisting of main T runner with suitably spaced joint to get required length and 15X32 mm made of 0.30mm sheet spaced between main T@600mm C/C from a ridge of 600X600mm and wall angle of size 15X20mm made of 0.30mm thick sheet and laying false ceiling tile in the grid including required cuttig /making opening for service like diffuser grils light suspended from ciling using GI soffit cleats fixed to existing rafters purlin etc with dash fastener GI adjustable rod of 3mm dia with galvanised butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T-sections shall be centre black prepainted with poiyester paint and having a load bearing capicity of 12kg/Sqm and refixed all existing electric wiring anf fixture all complete all heights as directed.
M&L for preparation of old steel and iron surface of any description, not otherwise described, over 10 cm width or girth applying two coat of Aluminium paint and over coat of aluminium red oxide priming with any shade as approved all as directed and specified.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends any radius in 110 mm dia complete all as specified and directed by Engr-in-Charge.
M&L for 300 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified.
M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in sides of pipes,foundation, filling and mass concrete etc complete all as specified and directed.
S&F powder coated curtain rods with brackets fixed to wall with suitable screws and onion type end bracket all as per approved design /colour/pattern fixed complete all as specified and directed by Engr-in-Charge
S&F aluminium powder coated (match with door shutters) Hydraullic door closer suitable for aluminium glass door shutters of 851 to1000 mm in width and of weight between 61 to 80 kgs and fixed complete all as specified and directed by Engr-in-Charge.
M&L for taking down chowkat or frames with shutters (without taking off shutters from the frames) n.exc 1.5 Sqm each complete all as specified and directed by Engr-in-Charge.
M&L for taking down Chowkats or frames exc 1.5 Sqm but not exceeding 4 Sq.M each with shutters (Without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge.
M&L for factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engr-in-Charge.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain wood grain printed PVC sheet reinforced with M.S. Square tube, in opening as per specification and drawings complete all as specified and directed by Engr-in-Charge.
S&F mortice lock with two lever MS body (vertical type) 100mm length of latch with 3 set of keys fixed in door shutter with proper in position complete all as specified.
S & F Stainless steel mosquito proof wire cloth of stainless 0.36mm dia and 1.4mm aperture fixed with aluminium flat/channel and screws all as specified as directed by Engr-In-Charge.
M&L for dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engr-in-Charge.
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based profile tilesheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
M&L for filling roof sheet gap between wall and roof sheet with brick coba /PCC 1:3:6 using 20mm graded aggregate up to D/S building with all arrangement of scafolding including making good with plaster and two coat of existing finish work as all as specified and as directed.
M&L for re securing or easing and adjustment with taking down steel rolling shutter, fixed with self tapping screws as specified including top cover,anchoring rod , hasp and staples and one coat of primer,erected in position as indicated complete push or manual type complete all as specified and as directed by Engr-in-charge.
S&F ball bearing for rolling shutters complete all as specified and as directed by Engr-in-charge.
S&F in repair rotational moulded polyethlene water storage tanks (cylindrical vertical with closed top three layered white in colour) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank 1000 Ltr complete all as specified and directed by Engr-in-Charge.
M&L for ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed complete all as specified and directed by Engr-in-Charge.
M&L for taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm dia complete all as specified and directed by Engr-in-Charge.
M&L for taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20mm dia complete all as specified and directed by Engr-in-Charge.
S&F Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm bore all as specified.
S&F Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore all as specified.
M&L for taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody for reuse or takeing in schedule of credit and making good disturbed surfaces of walls, floors etc all as specified as directed.
M&L for dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for reuse or takeing in schedule of credit (Accessories or components to be provided free for replacement by department)
M&L for taking down unserviceable / serviciable MCB DB's/AC's box to deposit in store for keeping in safe custody for reuse or takeing in schedule of credit of any size/rating complete all as specified and directed by Engr-in-charge.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 Sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel teRminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 Sqmm and making good, disturb surface as it is, all as specified and directed for The following. Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green (a) One light Point controlled by one,one way switch.
(b) One fan/exhaust fan/Air ciculator /bell point controlled by one way switch.
(c) All as per item No 74 above but 3 Pin 5 Amp Socket on the same board, complete all as specified.
(d) All as per item No 74 above but 3 Pin 5 Amp Socket on independent board , complete all as specified and directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 Sqmm drawn through in and including PVC conduit size of not less than 25mm concecled in wall / surface including provn of pressed steel teRminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 2.5 Sqmm and for one 6 pin socket outlet two in one 16/6 amps on an indeendent board including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green and making good, disturb surface as it is complete all as specified and directed
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 4 Sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel teRminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 4 Sqmm for AC box including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green and making good, disturb surface as it is complete all as specified and directed by for the following. Note : Rates are deemed to be included for chases of conduit and sunking for single pole and neutral enclosure boxes cutting and making holes in wall/floor for passing in or through conduit from DB to existing location
M&L for socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body. complete all as specified and directed..
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body.complete all as specified and directed.
S&F sheet metal enclosure single pole and neutral two pin and earth plug and socket complete with one single pole MCB SP 20 Amps for geyser complete all as specified and as directed.
M&L for switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed..
M&L for switch piano flush button 15 amps 240 volts with polycarbonate body complete all as specified and directed..
S&F in replaceent of MCB DB sheet enclosure single pole and neutral 240V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic single door complete confiRming to IP 43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed
S&F MCB, single pole & neutral, 240 Volts 40 Amps,10KA B series complete all as specified and directed
S&F MCB, single pole, 240 Volts (05 to 32) Amps,10KA, B series complete all as specified and directed
Supply and fix LED light fitting 1x18 watt 220 V AC dacorative box type with driver holder, includin LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from cilling rose complete all as specified and as directed by Engr-in-Charge
S&F LED light fitting PLUTO NEO PANEL 2'x2' PLR 36 watt LED 857S environmental friendly , new generation , aesthetically designed ,ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for aRmstrong /grid /ceiling all as spesified and directed.
Supply and fix round shape 12 watt 220 volts AC recessed type with high efficency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete
M&L in replacement for wiring with two single core 6 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 6 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and directed by Engr-in-charge.
M&L in replacement for wiring with four single core 10 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 10 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and directed by Engr-in-charge.
M&L for taking down and fixing only ceiling fan/wall mounted fan after painting and Necessary repairs / servicing including replacement of hanging assambly , bush bearing , U/S capacitor, flexible copper cord three core PVC sheathed of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose, surface bakelite, size as per relevant IS, three teRminals complete all as specified and directed
M&L for earthing complete to pole with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI wire 4 mm Dia as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision 20 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed . NOTE: (i) The concrete pit shall be PCC 1:3:6 type C-140 mm thick pre cast cover slab of RCC(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cost iron cover shown in the electrical plate No.3 of MES SSR Part -1 (ii) item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe,bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length Galvised earth strip 25x4 mm.
S&F ceiling fan regulator stepped electronic type 300 watt rating, 230 volts with polycarbonate body. Required screw, nut, bolt or cable are included in quoted rate, complete all as directed.
Supply, install , testing & commissioning factor made LT contorl panel board of adequate size having working space required maintenance totally enclosed front opening type cubical, floor mounted and out door type made out of 2 mm thick MS sheet with base frame of angle iron of size 50x50x5mm thick provided with copper bus bar - 04 Nos with colour coated sleeves of capacity 1.5 times of incommer and internal wiring with PVC insulated copper conductor cable of adequate size for making connections to various eqpts/accessories incl powder caoted painting (Internal & Externally) complete over a coat of red oxide primer all as specified CPRI approved including PCC foundation complete with comprising of following acessories. (a) Fixing only existing electric meters single phase digital with complete with fixing arrengement of electric meters inside the LT panel -08 Nos properly isolated from panel body by means of providing asbestos sheet as base cable connections. (b) MCCB, 4 Pole, 200 Amps, 36 KA-01 No. (c) MCB SPN 63 Amp-08 Nos (d) RYB indicator (set of three) -01 set) and incl taking down old one complete (e) Inbuilt change over switch indoor type 160 Amp 4 pole, 415V-01 (f) Voltmeter 415 V 3 Phase - 01 No (g) Amp meter 3 Phase 200 to 250 Amp - 01 (h) Feequency Meter-01
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6Sqmm galvanised iron or steel wire complete all as specified and directed
S&F LED street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant compete with driver, lamp bracket with impact and corrosion resistant including theRmal management in multiple optic complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips aRmoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and confoRming to IS : 7098 of 1995 and of size 3.5 core X 25 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply and laying sand cushioning for cable protection in trenches all as specified and directed.
M&L for GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia complete all as specified and directed by Engr-in-Charge.
Supply and laying un-reinforced precast concrete LV cable cover class type I with 250 X 150 X 40 mm, complete all as specified and directed by Engr-in-Charge.
M&L for removing excavated material exc 250m but n.exc 500m depositing where directed at a level n.exc 1.5m above the starting point complete all as per specified.
M/S GURU DEV BUILDERS
TULSI RAINA AND SONS
KUMAR CONSTRUCTION CO
SAI RS ENTERPRICSES
RAMAN KUMAR
M/S JANDIAL ENTERPRISES
M/S IMTESH BHAT
DURGA CONSTRUCTION CO
SHIVAE CONSTRUCTION
devraj chalotra
RAJ MOHD
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .